Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Can cool loop flows explain 'transition region' redshifts?

Observations of solar active regions reveal extensive areas of redshifted emission lines in the extreme ultraviolet, indicative of down flowing plasma. Redshifts are seen also in the magnetic network of the quiet sun and in magnetically active stars. The inferred velocities are large and appear to represent steady flows. Redshifts are not observed at higher coronal temperatures. It is shown here that steady flow in 'cool' loops driven by the buoyancy force set up by a small heating asymmetry between the two legs of the loop, offers a possible theoretical explanation of the observed features.

Mcclymont, Alexander N.↗

Test Bed for Investigating Anomalous Pump Behavior in a Single Phase Mechanically Pumped Flow Loop and Lessons Learned

NASA’s Europa Clipper mission is tasked with investigating the habitability of this icy moon of Jupiter and determining if it is capable of supporting life. The suite of powerful instruments necessary for this mission, combined with the harsh environment, require an elaborate single phase, mechanically pumped flow loop (MPFL) to redistribute waste heat around the spacecraft, thus minimizing energy requirements and avoiding the need for constant heating of the propulsion tanks. At the heart of this MPFL is a pump which will circulate fluid for the entirety of the 12-year mission; however, during initial qualification testing, anomalous behavior raised serious concerns regarding the pump and system design. Due to the critical nature of the pump, a major investigation was launched to evaluate the pump, system design, and the testing methodology employed to investigate this anomaly. This investigation resulted in a highly detailed analysis of the test loop, revised procedures, and the isolation/removal of variables impacting the quality of the observed pump behavior. The resulting test loop permitted comprehensive monitoring of the pump in the MPFL, including: flow rate, inlet and outlet static pressures, temperature, power consumption, and pump speed. Additionally, the investigation of the anomaly revealed several key lessons learned and helped institute a new set of best practices for future MPFL tests.

Miers, Collier↗

Observational signatures of loop flows driven by asymmetric heating

The observational consequences of highly asymmetric heating in small transition-region loops is studied using time-dependent numerical simulations. It is found that the plasma at C IV-emitting temperatures appears to be redshifted to an observer looking down on the loop. It is shown that the observation of a blueshifted emission line in the upper transition region of the sun or other late-type stars may not be evidence for the initial acceleration of the solar wind, but rather part of a closed circulation system.

Mariska, John T.↗

Experimental Results of Performance Tests on a Four-Port Wave Rotor

A series of tests has been performed on a four-port wave rotor suitable for use as a topping stage on a gas turbine engine, to measure the overall pressure ratio obtainable as a function of temperature ratio, inlet mass flow, loop flow ratio, and rotor speed. The wave rotor employed an open high pressure loop that is the high pressure inlet flow was not the air exhausted from the high pressure outlet, but was obtained from a separate heated source, although the mass flow rates of the two flows were balanced. This permitted the choice of a range of loop-flow ratios (i.e., ratio of high pressure flow to low pressure flow), as well as the possibility of examining the effect of mass flow imbalance. Imbalance could occur as a result of leakage or deliberate bleeding for cooling air. Measurements of the pressure drop in the high pressure loop were also obtained. A pressure ratio of 1.17 was obtained at a temperature ratio of 2.0, with an inlet mass flow of 0.6 lb/s. Earlier tests had given a pressure ratio of less than 1.12. The improvement was due to improved sealing between the high pressure and low pressure loops, and a modification to the movable end-wall which is provided to allow for rotor expansion.

Wilson, John↗

Evaluating Three Active Thermal Architectures for Exploration Missions

Mass and cost are typically the two biggest challenges facing space craft designers. Active thermal control systems for crewed space-craft are typically among the more massive and costly systems on the vehicle. A study was completed evaluating three different thermal control system architectures to evaluate overall performance, mass and cost for a typical exploration mission profile. The architectures that were evaluated were 1 - a two-loop system using an internal liquid loop interfacing with an external liquid loop and flow loop with flow through radiators; 2 - a-single loop architecture with flow through radiators utilizing a regenerative heat exchanger and heater; and 3 - a single-loop architecture with heat pipe radiators. Environmental conditions, calculated for a given lunar exploration mission, and mission heat load profiles, generated based on previous Orion time lines, were evalauated through the phases of the on orbit mission. Performance for each of the architectures was evaluated along with the resultant mass of each system. Recommendations include adding a thermal topping system to lunar missions due to the extreme hot environments encountered in near-lunar approaches.

Cross, Cynthia D.↗

Closed Loop Active Flow Separation Detection and Control in a Multistage Compressor

Active closed loop flow control was successfully demonstrated on a full annulus of stator vanes in a low speed axial compressor. Two independent methods of detecting separated flow conditions on the vane suction surface were developed. The first technique detects changes in static pressure along the vane suction surface, while the second method monitors variation in the potential field of the downstream rotor. Both methods may feasibly be used in future engines employing embedded flow control technology. In response to the detection of separated conditions, injection along the suction surface of each vane was used. Injected mass flow on the suction surface of stator vanes is known to reduce separation and the resulting limitation on static pressure rise due to lowered diffusion in the vane passage. A control algorithm was developed which provided a proportional response of the injected mass flow to the degree of separation, thereby minimizing the performance penalty on the compressor system.

Bright, Michelle M.↗

Mass flow in loop type coronal transients

Coronal transients having characteristics of a well-defined loop structure are examined, particularly with respect to temporal changes in the density and mass per unit length along the loop over periods of several days after the initial eruption. Measurements of mass distributions as a function of time are presented for eight transients, and one particular transient with a fairly simple configuration is investigated in more detail. Theoretical calculations are combined with the masses and densities derived from the observations to obtain estimates of the material flow in the transients; this flow is modeled on the assumption that magnetic forces drive and confine the loop. The flow field is found to be diverging everywhere, indicating that the density decreases in time. It is inferred that the transient legs are approximately in hydrostatic equilibrium and that most of the mass of the transient is lost from the sun during the initial phase.

Anzer, U.↗

Development of Flow Boiling and Condensation Experiment on the International Space Station- Normal and Low Gravity Flow Boiling Experiment Development and Test Results

Flow boiling and condensation have been identified as two key mechanisms for heat transport that are vital for achieving weight and volume reduction as well as performance enhancement in future space systems. Since inertia driven flows are demanding on power usage, lower flows are desirable. However, in microgravity, lower flows are dominated by forces other than inertia (like the capillary force). It is of paramount interest to investigate limits of low flows beyond which the flow is inertial enough to be gravity independent. One of the objectives of the Flow Boiling and Condensation Flight Experiment sets to investigate these limits for flow boiling and condensation. A two-phase flow loop consisting of a Flow Boiling Module and two Condensation Modules has been developed to experimentally study flow boiling condensation heat transfer in the reduced gravity environment provided by the reduced gravity platform. This effort supports the development of a flow boiling and condensation facility for the International Space Station (ISS). The closed loop test facility is designed to deliver the test fluid, FC-72 to the inlet of any one of the test modules at specified thermodynamic and flow conditions. The zero-g-aircraft tests will provide subcooled and saturated flow boiling critical heat flux and flow condensation heat transfer data over wide range of flow velocities. Additionally, these tests will verify the performance of all gravity sensitive components, such as evaporator, condenser and accumulator associated with the two-phase flow loop. We will present in this paper the breadboard development and testing results which consist of detailed performance evaluation of the heater and condenser combination in reduced and normal gravity. We will also present the design of the reduced gravity aircraft rack and the results of the ground flow boiling heat transfer testing performed with the Flow Boiling Module that is designed to investigate flow boiling heat transfer and Critical Heat Flux (CHF) phenomena.

microgravity↗

Bubble Formation and Detachment in Liquid Flow Under Normal and Reduced Gravity

Two-phase flows are present in a wide variety of applications for spacecraft thermal control systems design. Bubble formation and detachment is an integral part of the two-phase flow science. The authors objective is to experimentally investigate the effects of liquid cross velocity, gas velocity, and nozzle diameter on the bubble diameter at detachment under reduced and normal gravity and under relatively low gas flow rates. Results from ground (1 g) and reduced gravity experiments will be presented in this paper. For the 1 g experiment, a flow loop was designed and built to accommodate a range of liquid and gas flow rates. The reduced gravity experiment was conducted on the NASA DC-9 reduced gravity platform using the two-phase flow loop qualified for operation on the low-gravity platform. Flow visualization is accomplished using a high speed 500 frames/s camera. The results suggest that the existence of buoyancy force contributes to the faster detachment of bubbles. Buoyancy helps the detachment process which results in smaller bubbles being formed. In reduced gravity, although drag force is present, the virtual non-existence of buoyant force results in larger bubbles and longer times for detachment. Theoretical predictions are also presented in this paper and seem to agree with the experimental results.

Nahra, Henry K.↗

Particle Loading Tests on HEPA Flat Sheet Media at Sub-Ambient Pressures Using a Lunar Dust Simulant

When humans return to the moon under the NASA Artemis program, their activities on the lunar surface will inevitably lead to the intrusion of some level of lunar dust into the lander cabin. Therein the crew would be exposed to the potential hazards of lunar dust and the possibility of subsequent transfer into orbiting segments after docking. The spacecraft’s cabin filtration system will need to be effective at removing the airborne lunar dust to properly purify the breathable cabin air and minimize the spreading of the dust throughout the vehicle and orbital segments through the mission duration. The fine nature of the lunar dust will require high efficiency filtration, such as HEPA. A series of tests were performed in a specially designed recirculating sealed flow loop, for testing filter media and filter elements at the NASA Glenn Research Center. The flow loop was used to assess the performance and capacity of flat sheet filter media at representative cabin pressures using JSC-1AF lunar dust simulant and at high rates of particle loading. The pressure drop across the filter media was measured as a function of accumulated particle mass load at ambient pressure and at two sub-ambient pressures, 0.0703MPa and 0.0565MPa, and at a media velocity that was scaled relative to its pleated configuration. The challenge particle flows were generated by a custom designed particle generator that introduces dispersed particles of the lunar simulant at high concentrations. An optical particle counting instrument provided filter efficiency measurements within the sealed environment. The pressure drop was found to increase linearly with the amount of dust load on the media, for all test conditions, while the starting pressure drop was found to be lower at the lowest sub-ambient pressure case. High filter efficiency was maintained after high particle loads on the media.

Sub-ambient↗

Particle Loading Tests on HEPA Flat Sheet Media at Sub-Ambient Pressures Using a Lunar Dust Simulant

When humans return to the moon under the NASA Artemis program, their activities on the lunar surface will inevitably lead to the intrusion of some level of lunar dust into the lander cabin. Therein the crew would be exposed to the potential hazards of lunar dust and the possibility of subsequent transfer into orbiting segments after docking. The spacecraft’s cabin filtration system will need to be effective at removing the airborne lunar dust to properly purify the breathable cabin air and minimize the spreading of the dust throughout the vehicle and orbital segments through the mission duration. The fine nature of the lunar dust will require high efficiency filtration, such as HEPA. A series of tests were performed in a specially designed recirculating sealed flow loop, for testing filter media and filter elements at the NASA Glenn Research Center. The flow loop was used to assess the performance and capacity of flat sheet filter media at representative cabin pressures using JSC-1AF lunar he filter media was measured as a function of accumulated particle mdust simulant and at high rates of particle loading. The pressure drop across tass load at ambient pressure and at two sub-ambient pressures, 0.0703MPa and 0.0565MPa, and at a media velocity that was scaled relative to its pleated configuration. The challenge particle flows were generated by a custom designed particle generator that introduces dispersed particles of the lunar simulant at high concentrations. An optical particle counting instrument provided filter efficiency measurements within the sealed environment. The pressure drop was found to increase linearly with the amount of dust load on the media, for all test conditions, while the starting pressure drop was found to be lower at the lowest sub-ambient pressure case. High filter efficiency was maintained after high particle loads on the media

Sub-ambient↗

Current Activities in the Advanced Exploration Systems ISRU Project

Media Filter MOXIE support: completed flow performance tests and initial dust loading tests of the MOXIE HEPA filter in the Mars Flow Loop Designed and fabricated prototype full-scale scroll filter for testing of renewable filter performance Mars Flow Loop upgrades: installed more sensitive instrumentation, improved imaging, and increased run duration capability Electrostatic Precipitator (ESP) Plasma-physics based model predicts particle charge and trajectory Characterizing dust environment from fluidized-bed injection dust environment using laser sheet visualization and Fine Particle Analyzer Sabatier Design Study Defined the Sabatier design space, including reactor type, thermal management, gas recycling/separation Modeled Sabatier systems with one or two reactors with different types of thermal management Adding thermal management schemes and recycling and gas separation to model Catalyst Screening Performing compression testing on new and used catalyst pellets Performing vibration testing on different catalyst pellet types under different load conditions Preparing to test catalysts for performance and degradation

In-Situ Resource Utilization↗

Self-contained heat rejection module for future spacecraft

This paper discusses development of a Self-Contained Heat Rejection Module (SHRM) which can be used on a wide variety of future spacecraft launched by the space shuttle orbiter. The SHRM contains radiators which are deployed by a scissor-mechanism and the flow equipment including pumps, accumulator, by-pass valves, and controllers necessary to reject heat from those radiators. Heat transfer between SHRM and the parent vehicle is effected by a contact heat exchanger. This device provides heat transfer between two separate flow loops through a mechanical connection. This approach reduces the time required to attach the SHRM to the payload, and increases the reliability of the SHRM flow loop since breaking into the fluid system in the field is not required. The SHRM concept also includes a refrigeration system to increase heat rejection capacity in adverse environments, or to provide for a lower return temperature, down to -23 C.

Fleming, M. L.↗

Active Closed-Loop Stator Vane Flow Control Demonstrated in a Low-Speed Multistage Compressor

Closed-loop flow control was successfully demonstrated on the surface of stator vanes in NASA Glenn Research Center's Low-Speed Axial Compressor (LSAC) facility. This facility provides a flow field that accurately duplicates the aerodynamics of modern highly loaded compressors. Closed-loop active flow control uses sensors and actuators embedded within engine components to dynamically alter the internal flow path during off-nominal operation in order to optimize engine performance and maintain stable operation.

Bright, Michelle M.↗