Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow resistance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Relating flow resistance to equivalent roughness

Describing flow resistance using the physical properties of an underlying surface is a recalcitrant problem in overland flow models. If discharge measurements are available, an equivalent roughness (e.g., Manning’s n) can be calibrated to represent the effects of surface properties within the domain with a single numerical value. Alternatively, the flow resistance can be estimated from discharge and velocity measured at a point, typically a runoff plot outlet. However, such experimental estimates are often inconsistent with the equivalent roughness determined from calibration to discharge, even if both derive from the same dataset. For example, if Manning’s equation is used to parameterize flow resistance, the Manning’s n obtained by calibrating a model to discharge differs from the value of n calculated from measured flow and velocity at the hillslope outlet. Here, this discrepancy is resolved by deriving a correction factor relating experimentally-determined flow resistance to the equivalent roughness. The derived correction factor is tested for four commonly-used resistance formulations using 129 rainfall simulator experiments. The correction factor is necessary to reproduce measured velocities, and yields minor improvements in discharge prediction. Plain Language Summary: Accurate runoff prediction is needed for land and water management in dryland regions, where sporadic and limited rainfall necessitate efficient water use and drought mitigation strategies. The skill of runoff models is known to be hindered by out ability to estimate flow resistance, which is the quantity that describes how energy is lost from flowing water to the underlying surface. Typically, models represent flow resistance with an equivalent roughness, e.g., Manning’s n, that is adjusted until the model can reproduce available discharge observations at watershed scale. However, the flow resistance measured in plot-scale experiments (1–10 m) often exceeds equivalent roughness coefficients by a factor of 10. This means that the direct use of plot-scale experimental data to parameterize runoff models could cause errors in discharge and runoff velocity predictions. Here, we resolve these differences by deriving an analytic correction factor that relates flow resistance to the equivalent roughness required for models to reproduce experimental velocity and discharge data. This correction factor is tested using rainfall simulator data from 129 experiments performed in the US Southwest covering a wide range of precipitation intensities, soil textures and vegetation types. Use of the correction factor substantially improves model prediction of flow velocity, which is needed for reproducing the timing of flood events and the estimation of erosion.

54 ENVIRONMENTAL SCIENCES↗

Flow resistance of phloem sieve plates revisited using an experimental model

Sieve plate resistance has been identified as the key to understanding the efficiency of phloem transport of carbohydrates in trees. These plates with small holes connecting sieve tubes are responsible for the largest resistance to flow in the phloem. Their structure determines how fast sugars can be transported through the phloem with certain pressure differences and what the limits for phloem transport in different plants are. Because experiments with the phloem are very challenging, our understanding of sieve plate resistance is mostly based on anatomical studies and hydrodynamic modeling of flow through sieve plates. These models calculate the resistance of the entire sieve tube–sieve plate system using the Hagen–Poiseuille flow resistance for the sieve cell lumen and a combination of the Hagen–Poiseuille resistance and Sampson flow resistance through the sieve pores. The resistance of the entire sieve plate is calculated by summing the Hagen–Poiseuille and Sampson flow resistances of each pore. To test the validity of this model formulation, an experimental model with aspect parameters similar to phloem sieve tubes was built using polyvinyl chloride (PVC) piping and plastic straws of different diameters and lengths. This system was used to measure flow rates and calculate flow resistance at Reynolds numbers 0.5–300. The results suggest that the current models may significantly overestimate the flow resistance caused by sieve plates and that the resistance might be better described by formulations used for perforated plates.

54 ENVIRONMENTAL SCIENCES↗

Universal scaling-law for flow resistance over canopies with complex morphology

Flow resistance caused by vegetation is a key parameter to properly assess flood management and river restoration. However, quantifying the friction factor or any of its alternative metrics, e.g. the drag coefficient, in canopies with complex geometry has proven elusive. We explore the effect of canopy morphology on vegetated channels flow structure and resistance by treating the canopy as a porous medium characterized by an effective permeability, a property that describes the ease with which water can flow through the canopy layer. We employ a two-domain model for flow over and within the canopy, which couples the log-law in the free layer to the Darcy-Brinkman equation in the vegetated layer. We validate the model analytical solutions for the average velocity profile within and above the canopy, the volumetric discharge and the friction factor against data collected across a wide range of canopy morphologies encountered in riverine systems. Results indicate agreement between model predictions and data for both simple and complex plant morphologies. For low submergence canopies, we find a universal scaling law that relates friction factor with canopy permeability and a rescaled bulk Reynolds number. This provides a valuable tool to assess habitats sustainability associated with hydro-dynamical conditions.

54 ENVIRONMENTAL SCIENCES↗

Bypass Flow Resistance in Prismatic Gas-Cooled Nuclear Reactors

Available computational fluid dynamics (CFD) predictions of pressure distributions in the vertical bypass flow between blocks in a prismatic gas-cooled reactor (GCR) have been analyzed to deduce apparent friction factors and loss coefficients for systems and network codes. We performed calculations for vertical gap spacings "s" of 2, 6 and 10 mm, horizontal gaps between the blocks of two mm and two flow rates, giving a range of gap Reynolds numbers Re Dh of about 40 to 5300. Laminar predictions of the fully-developed friction factor f fd were about three to ten per cent lower than the classical infinitely-wide channel In the entry region, the local apparent friction factor was slightly higher than the classic idealized case but the hydraulic entry length L hy was approximately the same. The per cent reduction in flow resistance was greater than the per cent increase in flow area at the vertical corners of the blocks. The standard k-ϵ model was employed for flows expected to be turbulent. Its predictions of f fd and flow resistance were significantly higher than direct numerical simulations for the classic case; the value of L hy was about thirty gap spacings. Initial quantitative information for entry coefficients and loss coefficients for the expansion-contraction junctions between blocks is also presented. Our study demonstrates how CFD predictions can be employed to provide integral quantities needed in systems and network codes.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-Fidelity CFD Assessments of Flow Resistance in a 61-Pin Wire-Wrapped Assembly with Partially Blocked Channels

The examination of thermal-hydraulic behaviors in wire-wrapped rod bundles continues to be an active area of research. The sodium fast reactor, a prominent candidate in next-generation nuclear designs, utilizes a hexagonal configuration of wire-wrapped fuel pins. Here, the potential for channel blockage within this compact arrangement poses a significant safety challenge, spurring a number of recent experimental and computational investigations to evaluate its impact on flow and heat transfer. The present work aims to benchmark the high-fidelity NekRS computational fluid dynamics (CFD) solver in predicting the pressure drops associated with substantial blockages, using available experimental data as a reference. A 61-pin wire-wrapped fuel assembly with two flow blockage configurations has been simulated and investigated at a range of low to moderate Reynolds numbers (487 ≤ Re ≤ 14 600). The NekRS solver demonstrates an exponential reduction of spatial discretization error with increasing polynomial order. The high level of agreement between the numerical results and measured data confirms the accuracy and consistency of the present numerical approach. This benchmark study establishes the capability of NekRS to perform reliable hydrodynamic simulations for sodium fast reactor applications and supports its use in design, licensing, and safety analyses.

CFD Benchmarking↗

Numerical investigation on two-fluid model (micropolar-Newtonian) for pulsatile flow of blood in a tapered arterial stenosis with radially variable magnetic field and core fluid viscosity

In the present study, an unsteady two-fluid model of blood through a tapered arterial stenosis with variable viscosity in the presence of variable magnetic field has been investigated. In this model, blood in the core region is assumed to be micropolar and plasma in the peripheral layer as Newtonian. Finite difference method is employed in solving the governing equations. The solutions for velocity, flow rate, wall shear stress and flow resistance are computed numerically. A comparison between the velocity profiles obtained by the present study and the experimental data is made and a good agreement between them is found. The model is used to study the effect of parameters such as taper angle, radially variable viscosity, hematocrit, the coupling number, the micropolar parameter, magnetic field and plasma layer thickness on physiologically important parameters such as wall shear stress distribution in the stenotic region and flow resistance. The results in the case of constant magnetic field and variable magnetic field are compared to study the effects of magnetic field on the flow of blood. It is found that the magnitudes of wall shear stress and flow resistance are higher in the case of variable magnetic field. It is important to note that the flow resistance is higher for magneto-micropolar fluid than the micropolar fluid. The wall shear stress decreases with increasing hematocrit parameter whereas flow resistance increases with hematocrit when the applied pressure gradient is held fixed. The model clearly shows the situation of a patient with a tapered arterial stenosis under feverish condition. Due care has been taken to compare the present theoretical results with the existing ones including experimental results and good agreement between them has been observed both qualitatively and quantitatively.

42 ENGINEERING↗

Uniting Surface Properties With Hydrodynamic Roughness in Shallow Overland Flow Models

Describing flow resistance from the properties of an underlying surface is a challenge in surface hydrology. Runoff models must specify a resistance formulation or “roughness scheme”—describing the functional relationship between flow resistance and flow depth/velocity—and its parameters. Uncertainty in runoff predictions derives from both the selected roughness scheme (e.g., Darcy Weisbach, Manning's, or laminar flow equations), and its parameterization with a roughness coefficient (e.g., Manning's n). Both choices are informed by model calibration to data, usually discharge, and, if available, velocity. In this study, a Saint Venant Equation-based runoff model is calibrated to discharge and velocity data from 112 rainfall simulator experiments. The results are used to identify the optimal roughness scheme among four widely-used options for each experiment, and to explore whether surface properties can be used to select the optimal roughness scheme and its coefficient. Among the tested roughness schemes, a transitional flow equation provided the best fit to the plurality of experiments. The most suitable roughness scheme for a given experiment was not related to measured surface properties. Regression models predicted the calibrated roughness coefficients with adjusted values between 0.48 and 0.54, depending on the roughness scheme used. Litter cover was the best predictor of the roughness coefficient, followed by soil cover and average canopy gap size. The results suggest that selection of an optimal roughness scheme based on surface properties alone remains difficult, but that once a scheme is selected, roughness coefficients can be estimated from surface properties.

54 ENVIRONMENTAL SCIENCES↗

Interplay between fluctuation driven toroidal axisymmetric flows and resistive ballooning mode turbulence

An interplay between fluctuation driven toroidal axisymmetric flows (convective cell modes) and resistive ballooning mode turbulence after the pedestal collapse is numerically studied by a four-field reduced MHD model in the BOUT++ framework. The strong flow shear suppresses the radial transport of pressure filaments, and the pressure profile in the pedestal region is partially recovered. As a result, a secondary instability is quasilinearly excited, which yields a secondary collapse. Here, the subsequent damped oscillation is also analyzed by phase diagram analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Linear and nonlinear effect of sheared plasma flow on resistive tearing modes

The effect of sheared plasma flow on the m/n = 2/1 tearing mode is studied numerically (m and n are the poloidal and toroidal mode numbers). It is found that in the linear phase the plasma flow with a weak or moderate shear plays a stabilizing effect on tearing mode. However, the mode is driven to be more unstable by sufficiently strong sheared flow when approaching the shear Alfvén resonance (AR). In the nonlinear phase, a moderate (strong) sheared flow leads to a smaller (larger) saturated island width. The stabilization of tearing modes by moderate shear plasma flow is enhanced for a larger plasma viscosity and a lower Alfvén velocity. It is also found that in the nonlinear phase AR accelerates the plasma rotation around the 2/1 rational surface but decelerates it at the AR location, and the radial location satisfying AR spreads inwards towards the magnetic axis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

RELAP5 Analysis of the Hybrid Loop-Pool Design for Sodium Cooled Fast Reactors

An innovative hybrid loop-pool design for sodium cooled fast reactors (SFR-Hybrid) has been recently proposed. This design takes advantage of the inherent safety of a pool design and the compactness of a loop design to improve economics and safety of SFRs. In the hybrid loop-pool design, primary loops are formed by connecting the reactor outlet plenum (hot pool), intermediate heat exchangers (IHX), primary pumps and the reactor inlet plenum with pipes. The primary loops are immersed in the cold pool (buffer pool). Passive safety systems -- modular Pool Reactor Auxiliary Cooling Systems (PRACS) – are added to transfer decay heat from the primary system to the buffer pool during loss of forced circulation (LOFC) transients. The primary systems and the buffer pool are thermally coupled by the PRACS, which is composed of PRACS heat exchangers (PHX), fluidic diodes and connecting pipes. Fluidic diodes are simple, passive devices that provide large flow resistance in one direction and small flow resistance in reverse direction. Direct reactor auxiliary cooling system (DRACS) heat exchangers (DHX) are immersed in the cold pool to transfer decay heat to the environment by natural circulation. To prove the design concepts, especially how the passive safety systems behave during transients such as LOFC with scram, a RELAP5-3D model for the hybrid loop-pool design was developed. The simulations were done for both steady-state and transient conditions. This paper presents the details of RELAP5-3D analysis as well as the calculated thermal response during LOFC with scram. The 250 MW thermal power conventional pool type design of GNEP’s Advanced Burner Test Reactor (ABTR) developed by Argonne National Laboratory was used as the reference reactor core and primary loop design. The reactor inlet temperature is 355 °C and the outlet temperature is 510 °C. The core design is the same as that for ABTR. The steady state buffer pool temperature is the same as the reactor inlet temperature. The peak cladding, hot pool, cold pool and reactor inlet temperatures were calculated during LOFC. The results indicate that there are two phases during LOFC transient – the initial thermal equilibration phase and the long term decay heat removal phase. The initial thermal equilibration phase occurs over a few hundred seconds, as the system adjusts from forced circulation to natural circulation flow. Subsequently, during long-term heat removal phase all temperatures evolve very slowly due to the large thermal inertia of the primary and buffer pool systems. The results clearly show that passive safety PRACS can effectively transfer decay heat from the primary system to the buffer pool by natural circulation. The DRACS system in turn can effectively transfer the decay heat to the environment.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

An unsteady flow of magnetic nanoparticles as drug carrier suspended in micropolar fluid through a porous tapered arterial stenosis under non-uniform magnetic field and periodic body acceleration

A mathematical model has been developed for pulsatile flow of blood through a tapered arterial stenosis in a porous medium under the influence of non-uniform magnetic field and periodic body acceleration treating blood as micropolar fluid carrying iron oxide nanoparticles. The governing equations of the system are solved numerically using finite difference schemes. The effects of stenotic height, taper angle, micropolar parameters, magnetic field, porosity, pulsatility, and magnetic nanoparticles on the flow of blood are analysed, and the results are represented graphically. It is significant to note that the flow parameters such as wall shear stress and flow resistance increase with increase in stenotic height, tapering parameter, magnetic field, pulsatile Reynolds number, time period, particle concentration, and particle mass parameters. Wall shear stress decreases with the increasing values of coupling number and it shows opposite behaviour in the case of flow resistance. Also increase in Darcy number leads to decrease in wall shear stress and flow resistance. The significance of treating blood as micropolar fluid is that the rotation of particles is taken into account. Cardiovascular diseases occur mainly due to abnormal blood flow in the arteries. To normalize the blood flow in the arteries, analysis of parameters involved in the study is essential. Hence, the present study has various applications in biomedical sciences. The effects of nanoparticles on blood flow analysed in the study have significant applications in delivery of drugs for treating cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of Natural Circulation Instability and Transients in Passively Safe Small Modular Reactors

The NEUP funded project, NEUP-3496, aims to experimentally investigate two-phase natural circulation flow instability that could occur in Small Modular Reactors (SMRs), especially for natural circulation SMRs. The objective has been achieved by systematically performing tests to study the general natural circulation instability characteristics and the natural circulation behavior under start-up or design basis accident conditions. Experimental data sets highlighting the effect of void reactivity feedback as well as the effect of power ramp-up rate and system pressure have been used to develop a comprehensive stability map. The safety analysis code, RELAP5, has been used to evaluate experimental results and models. Improvements to the constitutive relations for flashing have been made in order to develop a reliable analysis tool. This research has been focusing on two generic SMR designs, i.e. a small modular Simplified Boiling Water Reactor (SBWR) like design and a small integral Pressurized Water Reactor (PWR) like design. A BWR-type natural circulation test facility was firstly built based on the three-level scaling analysis of the Purdue Novel Modular Reactor (NMR) with an electric output of 50 MWe, namely NMR-50, which represents a BWR-type SMR with a significantly reduced reactor pressure vessel (RPV) height. The experimental facility was installed with various equipment to measure thermalhydraulic parameters such as pressure, temperature, mass flow rate and void fraction. Characterization tests were performed before the startup transient tests and quasi-steady tests to determine the loop flow resistance. The control system and data acquisition system were programmed with LabVIEW to realize the realtime control and data storage. The thermal-hydraulic and nuclear coupled startup transients were performed to investigate the flow instabilities at low pressure and low power conditions for NMR-50. Two different power ramps were chosen to study the effect of startup power density on the flow instability. The experimental startup transient results showed the existence of three different flow instability mechanisms, i.e., flashing instability, condensation induced flow instability, and density wave oscillations. In addition, the void-reactivity feedback did not have significant effects on the flow instability during the startup transients for NMR-50. ii Several initial startup procedures with different power ramp rates were experimentally investigated to eliminate the flow instabilities observed from the startup transients. Particularly, the very slow startup transient and pressurized startup transient tests were performed and compared. It was found that the very slow startup transients by applying very small power density can eliminate the flashing oscillations in the single-phase natural circulation and stabilize the flow oscillations in the phase of net vapor generation. The initially pressurized startup procedure was tested to eliminate the flashing instability during the startup transients as well. The pressurized startup procedure included the initial pressurization, heat-up, and venting process. The startup transient tests showed that the pressurized startup procedure could eliminate the flow instability during the transition from single-phase flow to two-phase flow at low pressure conditions. The experimental results indicated that both startup procedures were applicable to the initial startup of NMR. However, the pressurized startup procedures might be preferred due to short operating hours required. In order to have a deeper understanding of natural circulation flow instability, the quasi-steady tests were performed using the test facility installed with preheater and subcooler. The effect of system pressure, core inlet subcooling, core power density, inlet flow resistance coefficient, and void reactivity feedback were investigated in the quasi-steady state tests. The experimental stability boundaries were determined between unstable and stable flow conditions in the dimensionless stability plane of inlet subcooling number and Zuber number. To predict the stability boundary theoretically, linear stability analysis in the frequency domain was performed at four sections of the natural circulation test loop. The flashing phenomena in the chimney section was considered as an axially uniform heat source. And the dimensionless characteristic equation of the pressure drop perturbation was obtained by considering the void fraction effect and outlet flow resistance in the core section. The theoretical flashing boundary showed some discrepancies with previous experimental data from the quasi-steady state tests. In the future, thermal non-equilibrium was recommended to improve the accuracy of flashing instability boundary. As another part of the funded research, flow instabilities of a PWR-type SMR under low pressure and low power conditions were investigated experimentally as well. The NuScale reactor design was selected as the prototype for the PWR-type SMR. In order to experimentally study the natural circulation behavior of NuScale iii reactor during accidental scenarios, detailed scaling analyses are necessary to ensure that the scaled phenomena could be obtained in a laboratory test facility. The three-level scaling method is used as well to obtain the scaling ratios derived from various non-dimensional numbers. The design of the ideally scaled facility (ISF) was initially accomplished based on these scaling ratios. Then the engineering scaled facility (ESF) was designed and constructed based on the ISF by considering engineering limitations including laboratory space, pipe size, and pipe connections etc. PWR-type SMR experiments were performed in this well-scaled test facility to investigate the potential thermal hydraulic flow instability during the blowdown events, which might occur during the loss of coolant accident (LOCA) and loss of heat sink accident (LOHS) of the prototype PWR-type SMR. Two kinds of experiments, normal blowdown event and cold blowdown event, were experimentally investigated and compared with code predictions. The normal blowdown event was experimentally simulated since an initial condition where the pressure was lower than the designed pressure of the experiment facility, while the code prediction of blowdown started from the normal operation condition. Important thermal hydraulic parameters including reactor pressure vessel (RPV) pressure, containment pressure, local void fraction and temperature, pressure drop and natural circulation flow rate were measured and analyzed during the blowdown event. The pressure and water level transients are similar to the experimental results published by NuScale [51], which proves the capability of current loop in simulating the thermal hydraulic transient of real PWR-type SMR. During the 20000s blowdown experiment, water level in the core was always above the active fuel assemble during the experiment and proved the safety of natural circulation cooling and water recycling design of PWR-type SMR. Besides, pressure, temperature, and water level transient can be accurately predicted by RELAP5 code. However, the oscillations of natural circulation flow rate, water level and pressure drops were observed during the blowdown transients. This kind of flow oscillations are related to the water level and the location upper plenum, which is a path for coolant flow from chimney to steam generator and down comer. In order to investigate the transients start from the opening of ADS valve in both experimental and numerical way, the cold blow-down experiment is conducted. For the cold blowdown event, different from setting both reactor iv pressure vessel (RPV) and containment at high temperature and pressure, only RPV was heated close to the highest designed pressure and then open the ADS valve, same process was predicted using RELAP5 code. By doing cold blowdown experiment, the entire transients from the opening of ADS can be investigated by code and benchmarked with experimental data. Similar flow instability observed in the cold blowdown experiment. The comparison between code prediction and experiment data showed that the RELAP5 code can successfully predict the pressure void fraction and temperature transient during the cold blowdown event with limited error, but numerical instability exists in predicting natural circulation flow rate. Besides, the code is lack of capability in predicting the water level related flow instability observed in experiments.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Counterflow heat exchanger with core and plenums at both ends

Here, this paper illustrates the morphing of flow architecture toward greater performance in a counterflow heat exchanger. The architecture consists of two plenums with a core of counterflow channels between them. Each stream enters one plenum and then flows in a channel that travels the core and crosses the second plenum. The volume of the heat exchanger is fixed while the volume fraction occupied by each plenum is variable. Performance is driven by two objectives, simultaneously: low flow resistance and low thermal resistance. The analytical and numerical results show that the overall flow resistance is the lowest when the core is absent, and each plenum occupies half of the available volume and is oriented in counterflow with the other plenum. In this configuration, the thermal resistance also reaches its lowest value. These conclusions hold for fully developed laminar flow and turbulent flow through the core. The curve for effectiveness vs number of heat transfer units (N tu ) is steeper (when N tu < 1) than the classical curves for counterflow and crossflow.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correlating cement characteristics with rheology of paste

The influence of cement characteristics such as cement fineness and clinker composition on the 'flow resistance' measured as the area under the shear stress-shear rate flow curve has been investigated. Three different types of plasticizers namely naphthalene sulphonate-formaldehyde condensate, polyether grafted polyacrylate, and lignosulphonate have been tested in this context on 6 different cements. The flow resistance correlated well with the cement characteristic (Blaine.{l_brace}d.cC{sub 3}A + [1 - d].C{sub 3}S{r_brace}) where the factor d represents relative reactivity of cubic C{sub 3}A and C{sub 3}S while cC{sub 3}A and C{sub 3}S represent the content of these minerals. It was found to be either a linear or exponential function of the combined cement characteristic depending on plasticizer type and dosage. The correlation was valid for a mix of pure cement and cement with fly ash, limestone filler (4%), as well as pastes with constant silica fume dosage, when the mineral contents were determined by Rietveld analysis of X-ray diffractograms.

36 MATERIALS SCIENCE↗

Study of natural circulation in a VHTR after a LOFA using different turbulence models

Natural convection currents in the core are anticipated in the event of the failure of the gas circulator in a prismatic gas-cooled very high temperature reactor (VHTR). The paths that the helium coolant takes in forming natural circulation loops and the effective heat transport are of interest. The heated flow in the reactor core is turbulent during normal operating conditions and at the beginning of the LOFA with forced convection, but the flow may significantly be slowed down after the event and laminarized with mixed convection. In the present study, the potential occurrence and effective heat transport of natural circulation are demonstrated using computational fluid dynamic (CFD) calculations with different turbulence models as well as laminar flow. Validations and recommendation on turbulence model selection are conducted. The study concludes that large loop natural convection is formed due to the enhanced turbulence levels by the buoyancy effect and the turbulent regime near the interface of upper plenum and flow channels increases the flow resistance for channel flows entering upper plenum and thus less heat can be removed from the core than the prediction by laminar flow assumption.

99 GENERAL AND MISCELLANEOUS↗

Viscous Dissipation and Apparent Permeability of Gas Flow in Nanoporous Media

The nanopore confinement effect can increase the mobility for gas flow in shale rocks, and the apparent permeability is usually adopted to account for this effect. However, most of the apparent permeability calculation models are derived based on straight channels (capillaries) and neglect the influence of end effect. The end effect is caused by the bending of streamlines which yields more viscous dissipation and additional flow resistance for gas flow in nanoporous media. Here, for the first time the viscous dissipation for gas flow in nanoporous media is analyzed. In addition, an improved apparent permeability calculation model is proposed based on the Beskok-Karniadakis (B-K) model by introducing the influence of end effect, which is characterized by the ratio of the length to the width of a short channel (L/H). The accuracy of this model is validated by lattice Boltzmann simulations of gas flow in three different geometries: an infinite-length straight channel, a finite-length straight channel, and nanoporous media. For the infinite-length straight channel, there is no end effect therefore both the B-K model and the improved model can well predict the apparent permeability. However, for the finite-length straight channel and nanoporous media, the original B-K model overestimates the gas apparent permeability as it neglects the influence of end effect, while the improved model can still well predict the gas apparent permeability. In summary, the improved apparent permeability calculation model is more reasonable in predicting gas mobility in nanoporous media.

58 GEOSCIENCES↗

Preferential Paths of Air-water Two-phase Flow in Porous Structures with Special Consideration of Channel Thickness Effects

Accurate understanding and predicting the flow paths of immiscible two-phase flow in rocky porous structures are of critical importance for the evaluation of oil or gas recovery and prediction of rock slides caused by gas-liquid flow. A 2D phase field model was established for compressible air-water two-phase flow in heterogenous porous structures. The dynamic characteristics of air-water two-phase interface and preferential paths in porous structures were simulated. The factors affecting the path selection of two-phase flow in porous structures were analyzed. Transparent physical models of complex porous structures were prepared using 3D printing technology. Tracer dye was used to visually observe the flow characteristics and path selection in air-water two-phase displacement experiments. The experimental observations agree with the numerical results used to validate the accuracy of phase field model. The effects of channel thickness on the air-water two-phase flow behavior and paths in porous structures were also analyzed. The results indicate that thick channels can induce secondary air flow paths due to the increase in flow resistance; consequently, the flow distribution is different from that in narrow channels. This study provides a new reference for quantitatively analyzing multi-phase flow and predicting the preferential paths of immiscible fluids in porous structures.

42 ENGINEERING↗

An examination of effects of solidification parameters on permeability of a mushy zone in castings

A model describing the development of dendritic structure and the resulting gradient of flow resistance to interdendritic liquid is presented. The Hagen–Pousielle version of D’Arcy’s equation for flow through a porous structure is developed as a function of cooling rate and liquid volume fraction. Applied to finite elements in a unidirectionally cooled casting model, permeability gradient, feeding flow-rate required to prevent porosity, and mushy-zone liquid pressure drop at this flow rate are evaluated for the simple Fe–2Cr–0.5C and Al–5Cu castings exhibiting asymptotic and linear temperature profiles, respectively. The model shows permeability of the dendritic structure in the mushy zone dropping sharply, approaching the root of solidification front (solidus). Also shown is the effect of relative magnitude of primary and secondary arm spacing. If secondary dendrite arm spacing approaches primary arm spacing, the permeability for flow normal to primary dendrite arms approaches or even surpasses the permeability for flow parallel to primary dendrite arms.

36 MATERIALS SCIENCE↗