Flue Gas Desulfurization Wastewater Composition and Implications for Regulatory and Treatment Train Design

The U.S. Environmental Protection Agency is currently revising its regulations on trace element discharges from flue gas desulfurization (FGD) wastewater.<br>In this work, we expand a predictive model of trace element behavior at coal-fired power plants (CFPPs) to estimate the trace element concentration of FGD wastewater at the plant level. We demonstrate that variation in trace element concentrations in FGD wastewater can span several orders of magnitude and is a function of both coal rank and installed air pollution control devices. This conclusion suggests that the benefits and costs of FGD wastewater treatment for the median plant will poorly describe the actual benefits and costs over the full range of existing CFPPs.

Mauter, Meagan↗

Characteristics and reactivity of rapidly hydrated sorbent for semidry flue gas desulfurization

The semidry flue gas desulfurization (FGD) process has many advantages over the wet FGD process for moving sulfur dioxide emissions from pulverized coal-fired power plants. Semidry FGD with a rapidly hydrated sorbent was studied in a pilot-scale circulating fluidized bed (CFB) experimental facility. The sorbent was made from lumps of lime and coal fly ash. The desulfurization efficiency was measured for various operating parameters, including the sorbent recirculation rate and the water spray method. The experimental results show that the desulfurization efficiencies of the rapidly hydrated sorbent were 1.5-3.0 times higher than a commonly used industrial sorbent for calcium to sulfur molar ratios from 1.2 to 3.0, mainly due to the higher specific surface area and pore volume. The Ca(OH){sub 2} content in the cyclone separator ash was about 2.9% for the rapidly hydrated sorbent and was about 0.1% for the commonly used industrial sorbent, due to the different adhesion between the fine Ca(OH){sub 2} particles and the fly ash particles, and the low cyclone separation efficiency for the fine Ca(OH){sub 2} particles that fell off the sorbent particles. Therefore the actual recirculation rates of the active sorbent with Ca(OH){sub 2} particles were higher for the rapidly hydrated sorbent, which also contributed to the higher desulfurization efficiency. The high fly ash content in the rapidly hydrated sorbent resulted in good operating stability. The desulfurization efficiency with upstream water spray was 10-15% higher than that with downstream water spray. 20 refs., 7 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

Transport and Transformation of Selenium and Other Constituents of Flue‐Gas Desulfurization Wastewater in Water‐Saturated Soil Materials

Constructed wetland treatment systems are used to remove selenium (Se) from flue‐gas desulfurization (FGD) wastewater (WW). However, direct confirmation of the mechanism responsible for FGD WW Se retention in soil is lacking. A laboratory‐based soil column study was performed to develop an evidence‐based mechanism of Se retention and to study the behavior and the retention capacity of FGD WW constituents in water‐saturated soil. A deoxygenated 1:1 mixture of FGD WW and raw water was delivered to the columns bottom‐up at a flux of 1.68 cm d −1 for 100 d. Some of the columns were flushed with the raw water at the same rate for an additional 100 d. Column effluent was analyzed for constituents of concern. Results showed a complete retention of FGD WW Se in the soil materials. Boron and fluorine were partially retained; however, sulfur, sodium, and chlorine retention was poor, agreeing with field observations. The FGD WW Se was retained in soil near the inlet end of the columns, indicating its limited mobility under reduced conditions. Sequential extraction procedure revealed that retained Se was mainly sequestered as stable/residual forms. Bulk‐ and micro‐X‐ray absorption near‐edge structure spectroscopy confirmed that Se was mainly retained as reduced/stable species [Se(IV), organic Se, and Se(0)]. This study provides direct evidence for FGD WW Se retention in water‐saturated soil via the transformation of oxidized Se into reduced/stable forms. Core Ideas The mechanism of FGD wastewater Se retention in water‐saturated soil was studied. Sequential fractionation of Se, micro‐XRF, and micro‐ and bulk‐XANES were used. Behavior of FGD wastewater constituents in saturated soil was comparable to field‐scale observations. FGD wastewater Se exhibited strong retention in reduced soil. Reduced/stable species of Se governed the retention mechanism.

Galkaduwa, Madhubhashini B.↗

Potential Agricultural Uses of Flue Gas Desulfurization Gypsum in the Northern Great Plains

Flue gas desulfurization gypsum (FGDG) is a byproduct from the combustion of coal for electrical energy production. Currently, FGDG is being produced by 15 electrical generating stations in Alabama, Florida, Indiana, Iowa, Kentucky, Ohio, North Carolina, South Carolina, Tennessee, Texas, and Wisconsin. Much of this byproduct is used in the manufacturing of wallboard. The National Network for Use of FGDG in Agriculture was initiated to explore alternative uses of this byproduct. In the northern Great Plains (North Dakota, South Dakota, and Montana), FGDG has the potential to be used as a Ca or S fertilizer, as an acid soil ameliorant, and for reclaiming or mitigating sodium-affected soils. Greater than 1.4 million Mg of FGDG could initially be used in these states for these purposes. Flue gas desulfurization gypsum can be an agriculturally important resource for helping to increase the usefulness of problem soils and to increase crop and rangeland production. Conducting beneficial use audits would increase the public awareness of this product and help identify to coal combustion electrical generating stations the agriculturally beneficial outlets for this byproduct.

01 COAL, LIGNITE, AND PEAT↗

Investigation on the application of C12A7 in flue gas desulfurization at low-moderate temperature

It has been demonstrated that radicals and/or anions can promote chain reactions improving desulfurization efficiency in flue gas. Recent studies have evidently shown that specially synthesized C12A7 is a prominent source of O{sup -} which has been found to be one of the most active radicals acting as a potential oxidant in many applications. In the interest of applying C12A7 in flue gas desulfurization for coal combustion facilities, reactions of C12A7 with SO{sub 2} at 200-700{sup o}C were implemented in a plug flow reactor. Both SO{sub 2} removal efficiency and the apparent reaction rate constants derived from the experiments were compared with those of CaO. The products were analyzed by TG-MS and FTIR. The result showed that under the experimental conditions the reactivity of C12A7 directly reacted with SO{sub 2} was lower than CaO samples because of its low surface area accessibility. The product analysis verified that O{sup -} in C12A7 was involved in desulfurization reaction as an effective oxidant. On the basis of these results, a feasible application approach for C12A7 in desulfurization process was suggested so as to improve SO{sub 2} removal efficiency. A preliminary experiment was further devised to support the feasibility. 22 refs., 12 figs.

01 COAL, LIGNITE, AND PEAT↗

Effect of potassium sodium tartrate and sodium citrate on the preparation of {alpha}-calcium sulfate hemihydrate from flue gas desulfurization gypsum in a concentrated electrolyte solution

Flue gas desulfurization (FGD) gypsum mainly composed of calcium sulfate dihydrate (DH) was used as a raw material to obtain alpha-calcium sulfate hemihydrate ({alpha}-HH) through dehydration in a Ca-Mg-K-Cl-solution medium at 95{sup o}C under atmospheric pressure. The effects of potassium sodium tartrate and sodium citrate on the preparation of alpha-HH in the electrolyte solution were investigated. The results revealed that the addition of potassium sodium tartrate (1.0 x 10{sup -2} - 2.5 x 10{sup -2}M) decreased the dehydration rate of FGD gypsum and increased the length/width (l/w) ratio of {alpha}-HH crystals, which could yield unfavorable strength properties. Addition of sodium citrate (1.0 x 10{sup -5} - 2.0 x 10{sup -5}M) slightly increased the dehydration rate of FGD gypsum and decreased the l/w ratio of {alpha}-HH crystals, which could be beneficial to increase strength. However, it also led to a partial formation of anhydrite (AH) crystals. AH was also the only dehydration product when the concentration of sodium citrate increased to 1.0 x 10{sup -4}M. Therefore, sodium citrate rather than potassium sodium tartrate could be used as an additive in Ca-Mg-K-Cl electrolyte solutions if alpha-HH with a shorter l/w ratio is the desired product from FGD gypsum dehydration. The concentration of sodium citrate should be properly controlled to reduce the formation of AH.

01 COAL, LIGNITE, AND PEAT↗

Flue gas desulfurization with an electrostatic spraying absorber

A flue gas desulfurization device and process were developed and tested in this study. The process used an electrostatic spraying absorber (ESA) as the reactor, where SO{sub 2} was absorbed into an aqueous slurry of reactive Ca(OH){sub 2}. The absorption process was analyzed by using the two-film theory of mass-transfer. Both the liquid and gas side resistances were important, and the absorption rate was controlled by a combination of both gas-film and liquid-film diffusion controls. The ESA characteristics were investigated between applied voltages from -10 to 10 kV at various slurry flow rates. The SO{sub 2} removal efficiency was independent of the polarity of the applied voltage. A slightly higher efficiency was obtained with the conduction charging configuration than with the induction charging configuration. A model of external mass-transfer with a chemical enhancement factor was proposed for estimation of the absorption efficiency; the theoretical SO{sub 2} removal efficiency obtained was compared with the experimental data. 18 refs., 6 figs., 2 tabs.

01 COAL, LIGNITE, AND PEAT↗

Effective removal of trace-level toxic metals from flue gas desulfurization wastewater using SiO 2 supported hydrogel sorbent

Flue gas desulfurization (FGD) wastewater generated from coal-fired power plants contain potentially harmful heavy metal pollutants that pose a threat to public health and clean water. In this work, we present a water stable polyethylenimine-n,n’-methylenebisacrylamide (PEI-MBAA) functionalized SiO 2 solid sorbent material (PMS-1.2/1/4) and investigate its metal adsorption kinetics, selectivity, regenerability, and space velocity. The kinetic studies of six of the toxic heavy metals (As, Cd, Cr, Pb, Se, and Hg) prepared with single elements in Milli-Q water showed the effect of chemical bonding and intraparticle mass transfer resistance on the sorption process. The selectivity studies demonstrated the significant adsorption efficiency toward trace-level heavy metals (Se, Cd, U, Al, etc.) from authentic industrial FGD wastewater. Through five consecutive adsorption–desorption cycles with the FGD (uptake)-citrate (release)-based buffer pair, the sorbent showed high heavy metal removal ability and good reusability. The maximum flow rate for the removal of Se from industrial FGD wastewater was determined to be as high as 8 bed volumes/minute of the sorbent bed. Finally, the results demonstrate the PMS-1.2/1.4 sorbent is a promising candidate for the removal of heavy metals from practical aqueous solutions.

36 MATERIALS SCIENCE↗

Flue gas desulfurization wastewater treatment primer

Purge water from a typical wet flue gas desulfurization system contains myriad chemical constituents and heavy metals whose mixture is determined by the fuel source and combustion products as well as the stack gas treatment process. A well-designed water treatment system can tolerate upstream fuel and sorbent arranged in just the right order to produce wastewater acceptable for discharge. This article presents state-of-the-art technologies for treating the waste water that is generated by wet FGD systems. 11 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

TEM study the corrosion behavior of the low alloy steels developed for flue gas desulfurization system

Highlights: • Corrosion mechanism of low alloy steels for flue gas desulfurization was studied. • An amorphous corrosion layer enriched with Fe, O, S formed on the blank specimen. • Added Cu concentrated, crystallized and grown to particles in corrosion layer. • Corrosion resistance of the steels depended on the form of Cu in corrosion layer. • Sb addition slows the crystallization and growth of Cu particles in corrosion layer. - Abstract: This study investigated the corrosion behavior and underline mechanisms of low alloy steels with a minor addition of 0.4 wt% Cu, 0.2 wt% Ni, 0.1 wt% Sb and 0.05 wt% Co developed for a flue gas desulfurization (FGD) system. Corrosion tests were carried out in an aggressive solution of 16.9 vol% H{sub 2}SO{sub 4} + 0.35 vol% HCl + Bal. H{sub 2}O at 60 °C for up to 48 h. The experimental results revealed enrichment of the additional elements (Cu, Sb and Ni) in the corrosion layer, whose concentration increased with test time. As the concentrations of Cu increased, the crystallization and growth of the Cu particles (from several nm to 320 nm)) within the corrosion layer was accelerated. At the initial stage of the test, a continuous amorphous layer rich with the additional elements formed and covered the surface of the steel, which then gradually developed defects, pores and cracks, as the crystallization and growth of Cu particles with the elapse of time. The results indicated that the corrosion resistance of the low alloy steel depends on the existence form of Cu in the corrosion layer, i.e., as solute atoms or as nanoparticles strengthened the corrosion layer and increased corrosion resistance. As the coarsening of Cu particles weakened the corrosion layer and deteriorated the corrosion resistance.

36 MATERIALS SCIENCE↗

Early age hydration behavior of portland cement-based binders incorporating fly ash contaminated with flue gas desulfurization products

Fly ash co-mingled with flue gas desulfurization (FGD) products are currently discarded as off-specification materials based on their high SO3 content. However, previous studies have shown that performance of these fly ashes varies significantly based on FGD product type and as such they may be viable for use in low-CO2 concrete as supplementary cementitious materials (SCMs). In this study, fly ashes with three different types of FGD products including calcium sulfite hemihydrate, calcium sulfate (with some unreacted lime), and sodium sulfate (with some unreacted sodium carbonate) were evaluated. The early age hydration behavior in blended cementitious systems at 20% cement replacement level was studied using Vicat setting time tests, isothermal calorimetry, in-situ quantitative X-ray diffraction, and pore solution analysis. The cause of the setting time retardation and flash setting observed in fly ashes with calcium sulfite hemihydrate and sodium carbonate, respectively, were identified and suitable beneficiation options were suggested for the valorized use of these materials in low-CO 2 concrete.

36 MATERIALS SCIENCE↗

Investigation of a mercury speciation technique for flue gas desulfurization materials

Most of the synthetic gypsum generated from wet flue gas desulfurization (FGD) scrubbers is currently being used for wallboard production. Because oxidized mercury is readily captured by the wet FGD scrubber, and coal-fired power plants equipped with wet scrubbers desire to benefit from the partial mercury control that these systems provide, some mercury is likely to be bound in with the FGD gypsum and wallboard. In this study, the feasibility of identifying mercury species in the FGD gypsum and wallboard samples was investigated using a large sample size thermal desorption method and samples from power plants in Pennsylvania. Potential candidates of pure mercury standards including mercuric chloride, mercurous chloride, mercury oxide, mercury sulfide, and mercuric sulfate were analyzed to compare their results with those obtained from FGD gypsum and dry wallboard samples. Although any of the thermal evolutionary curves obtained from these pure mercury standards did not exactly match with those of the FGD gypsum and wallboard samples, it was identified that Hg{sub 2}Cl{sub 2} and HgCl{sub 2} could be candidates. An additional chlorine analysis from the gypsum and wallboard samples indicated that the chlorine concentrations were approximately 2 orders of magnitude higher than the mercury concentrations, suggesting possible chlorine association with mercury. 21 refs., 5 figs., 3 tabs.

01 COAL, LIGNITE, AND PEAT↗

Multiscale modeling and nonlinear model predictive control for flue gas desulfurization

The primary source of sulfur dioxide (SO 2 ) emissions is flue gas from fossil fuels-based power plants. SO 2 emissions are known to not only cause health issues, but also have an adverse effect on the environment in various ways. Several Flue Gas Desulfurization (FGD) technologies have been incorporated in power plants. The most popular technology is Wet FGD, where a limestone slurry is used to absorb SO 2 from the flue gas. A detailed droplet scale model describing the instantaneous and finite rate chemistry is developed. The ill-posed Differential-Algebraic Equation (DAE) droplet model is reformulated to a well-posed index-1 DAE through index reduction. The droplet model is integrated with the bulk phase by incorporating gas-liquid mass transfer, and an oxidation reactor model to simulate the dynamic operation of the counter-current spray scrubber. As a result, the model has a well-conditioned Jacobian and overcomes the modeling challenges of previous works and enables numerical solution without requiring carefully selected initialization or specialized solution procedures. The model is successfully validated using power plant measurements, and nonlinear model predictive control (NMPC) studies are demonstrated to optimize recycle stream flowrates to minimize pumping costs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study on multiphase flow and mixing in semidry flue gas desulfurization with a multifluid alkaline spray generator using particle image velocimetry

Particle image velocimetry (PIV) technique was used to measure the velocity fields of gas-droplet-solid multiphase flow in the experimental setup of a novel semidry flue gas desulfurization process with a multifluid alkaline spray generator. The flow structure, mixing characteristic, and interphase interaction of gas-droplet-solid multiphase flow were investigated both in the confined alkaline spray generator and in the duct bent pipe section. The results show that sorbent particles in the confined alkaline spray generator are entrained into the spray core zone by a high-speed spray jet and most of the sorbent particles can be effectively humidified by spray water fine droplets to form aqueous lime slurry droplets. Moreover, a minimum amount of air stream in the generator is necessary to achieve higher collision humidification efficiency between sorbent particles and spray water droplets and to prevent the possible deposition of fine droplets on the wall. The appropriate penetration length of the slurry droplets from the generator can make uniform mixing between the formed slurry droplets and main air stream in the duct bent pipe section, which is beneficial to improving sulfur dioxide removal efficiency and to preventing the deposition of droplets on the wall.

01 COAL, LIGNITE, AND PEAT↗

Numerical simulation of multiphase flow and collision humidification in the multifluid alkaline spray generator for a novel semidry flue gas desulfurization system

A hybrid Eulerian-Lagrangian model was developed to simulate gas-droplet-particle multiphase flow and the collision humidification between sorbent particles and spray droplets in the confined multifluid alkaline spray generator for a novel semidry flue gas desulfurization system. In this model, the motions of discrete phases were tracked simultaneously by using a stochastic trajectory approach, and a probability model of droplets catching particles was presented to judge whether sorbent particles were caught with direct simulation Monte Carlo method. Numerical humidification efficiency of sorbent particles is validated by the experimental one deduced from the measured desulfurization efficiency. The effects of flue gas flow rate, spray droplet diameter, sorbent particle diameter, and particle injection location on the humidification efficiency were optimized. Numerical results show that the collision humidification efficiency of sorbent particles increases significantly at the axial distance of 1.67 times the generator diameter from the nozzle tip and reaches 78.5% without recirculation flow in the alkaline spray generator when the ratio of flue gas mass flow rate to spray water mass flow rate is 6.7. Moreover, there is an optimal droplet diameter ranging from 125 to 150 {mu} m and an optimal particle injection location corresponding to the maximum humidification efficiency in this paper.

01 COAL, LIGNITE, AND PEAT↗

Flue Gas Desulfurization (FGD) Wastewater Treatment Using Polybenzimidazole (PBI) Hollow Fiber (HF) Membranes

Polybenzimidazole (PBI) hollow fiber membranes were used to treat flue gas desulfurization (FGD) wastewater (WW) from a coal fired power plant. Membranes were tested using both single salt solutions and real FGD WW. The PBI membranes showed >99% rejection for single salt solutions of NaCl, MgCl2, CaSO4, and CaCl2 at approximately 2000 PPM (parts per million). The membranes also showed >97% rejection for FGD WW concentrations ranging from 6900 to 14,400 PPM total dissolved solids (TDS). The pH of the FGD WW was adjusted between 3.97–8.20, and there was an optimal pH between 5.31 and 7.80 where %rejection reached a maximum of >99%. The membranes were able to operate stably up to 50 °C, nearly doubling the water flux as compared to room temperature, and while maintaining >98% salt rejection.

activation energy↗

Controllability analysis and decentralized control of a wet limestone flue gas desulfurization plant

Presently, decentralized feedback control is the only control strategy used in wet limestone flue gas desulfurization (WLFGD) plants. Proper tuning of this control strategy is becoming an important issue in WLFGD plants because more stringent SO{sub 2} regulations have come into force recently. Controllability analysis is a highly valuable tool for proper design of control systems, but it has not been applied to WLFGD plants so far. In this paper a decentralized control strategy is designed and applied to a WLFGD pilot plant taking into account the conclusions of a controllability analysis. The results reveal that good SO{sub 2} control in WLFGD plants can be achieved mainly because the main disturbance of the process is well-aligned with the plant and interactions between control loops are beneficial to SO{sub 2} control.

01 COAL, LIGNITE, AND PEAT↗