Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fluence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Measured Thermal and Fast Neutrons Fluence Rates for ATF-1 Holders During ATR Cycle 166B

This report contains the thermal (2200 m/s) and fast (E>lMeV) neutron fluence rate data for the ATF-1 holders located in core for ATR Cycle 166B which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains measurements of the fluence rates corresponding to the particular elevations relative to the 80-ft. core elevation. The data in this report consist of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, and (3) plots of both the thermal and fast neutron fluence rates. All "BR" holder monitor wires for this cycle are 56.375 inches long. This length allows measurements from 31.17 inches above core midplane to 19.81 inches below core midplane. The distance from the end of the wires to the first count position was 4.25 inches for all wires counted from this cycle. The monitors were located in an outward small I-holes,1-22 and 1-23. Thermal neutron fluence was determined based on the activation of the CoAl wires and resonance corrections determined in the irradiation of Cycle 152A when the RML measured cadmium-covered as well as bare neutron monitors in the Southwest, Southeast, and H positions at the Center lobe to determine the division in neutron energy between epithermal and thermal neutrons. For more information please refer to letter “Radiation Measurements Laboratory measurements of in core ATR physics testing during cycle 152A. The measured values documented in RML procedure, “ACMM-3600, Flux Monitoring,” will be used indefinitely until further measurements supersede the current values. Fast neutron fluence was determined using the activation of nickel wires. Typically, a fission spectrum averaged cross section (E>1 MeV) is used as determined in detailed measurements described in “ATR Neutron Spectral Characterization,” which gives an effective cross section of 97 mb for the small I-holes. However, those measurements were performed with unfueled experiments. The fast fluence values reported here use a perturbed 114 mb effective>1 MeV spectrum averaged cross section for the small I-holes based on MCNP simulations for a previous fueled experiment in the1-24 position. Refer to “LWR- ATR Irradiation Measured Thermal and Fast Neutron Fluence Rates ATR CYCLE 133A 04/19/04 thru 05/17/04” for more information.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measured Thermal And Fast Neutron Fluence Rates ATR Cycle 169A

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 169A which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains fluence rate values corresponding to the particular elevations (relative to the 80-ft. core elevation) where the measurements were taken. The data in this report consists of ( 1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, (3) plots of both the thermal and fast neutron fluence rates, and (4) an optical record (compact disk) containing a listing of the thermal and the fast neutron fluence rates, their assigned elevations and proper header identification of all monitor positions contained herein. The fluence rates reported are for the average power levels given in the table of power history and distribution. No neutron monitors were located in the N-2 position during this cycle. All "SR" holder monitor wires for this cycle are 55 inches long. This length allows measurements from 24.73 inches above core midplane to 25.25 inches below core midplane. The distance from the end of the wires to the first count position was 4.25 inches for all wires counted from this cycle.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The dependence of tungsten fuzz layer thickness and porosity on tungsten deposition rate and helium ion fluence

Abstract Fuzz formation on a heated tungsten surface in the presence of a helium-containing plasma and tungsten deposition source was investigated. Tungsten samples were exposed at 1123 K to pure helium plasma with ion incident energy of 76 eV, W/He ion flux ratio of ∼ 0.4 × 10 − 4 , and varied helium ion fluence from 0.18 to 3.4 × 10 26 m −2 . Fuzz thickness was measured by cross-sectional scanning electron microscopy to increase from 0.22 to 15 µ m with increasing helium ion fluence. No indication of saturation in fuzz thickness at high fluence was observed, in contrast to fuzz produced on a tungsten surface without tungsten deposition. Additional tungsten samples were exposed at 1123 K to pure helium plasma with ion incident energy of 76 eV, helium ion fluence of ∼ 3.4 × 10 26 m −2 , and varied W/He ion flux ratio from 0.26 to 3.0 × 10 − 4 . Fuzz thickness increased from 7.5 to 120 µ m with increasing W/He ion ratio. A final sample exposed at 1123 K to a mixed helium-deuterium plasma with ion incident energy of 76 eV, helium ion fluence of 0.18 × 10 26 m −2 , and W/He ion flux ratio of 2.2 × 10 − 4 developed nearly identical fuzz structures to that developed in a pure He plasma. As a function of deposited tungsten fluence, all results were found to trace out a single layer-growth curve given by a power law relation, indicating that fuzz thickness is independent of the W/He ion flux ratio in the range investigated and independent of any deuterium present in the plasma. As a result, for tungsten plasma facing walls in magnetic fusion devices at 1000–2000 K with 10 −4 W/He ion flux ratio, fuzz with thicknesses greater than hundreds of microns may form in as little as 10 4 s (in the absence of ELM-induced erosion or annealing), and may more significantly affect its thermophysical properties than fuzz generated without a tungsten deposition source.

Physics↗

Measured Thermal And Fast Neutron Fluence Rates ATR Cycle 166B

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 166B which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains fluence rate values corresponding to the particular elevations (relative to the 80-ft. core elevation) where the measurements were taken. The data in this report consists of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, (3) plots of both the thermal and fast neutron fluence rates, and (4) an optical record (compact disk) containing a listing of the thermal and the fast neutron fluence rates, their assigned elevations and proper header identification of all monitor positions contained herein. The fluence rates reported are for the average power levels given in the table of power history and distribution. No neutron monitors were located in the N-2 position during this cycle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 171A ATF (Rev. 1)

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 171A ATF which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains fluence rate values corresponding to the particular elevations (relative to the 80-ft. core elevation) where the measurements were taken. The data in this report consists of (1) a table of the ATR power history and distribution, (2) a listing of the calculated thermal and fast neutron fluence rates, and (3) plots of calculated both the thermal and fast neutron fluence rates. The fluence rates reported are for the average power levels given in the table of power history and distribution. During the irradiation of Cycle 152A, the RML performed additional flux measurements to assess core reconfiguration issues. Measurements using cadmium covered as well as bare neutron monitors in the Southwest, Southeast, and H positions of the Center lobe were performed to determine the division in neutron energy between epithermal and thermal neutrons. This is defined as the resonance correction defined in this report. It is used to quantify both thermal and fast neutron flux. For more information please refer to letter, “RADIATION MEASUREMENTS LABORATORY MEASUREMENTS OF IN CORE ATR PHYSICS TESTING DURING CYCLE 152A” dated January 24, 2013, to Casey Stengel from C. C. Jensen. The measured values documented in RML Procedure, “ACMM-3600, Flux Monitoring,” will be used indefinitely until further measurements supersede the current values.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 171A IR TMIST 3B

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 171A which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains fluence rate values corresponding to the particular elevations (relative to the 80-ft. core elevation) where the measurements were taken. The data in this report consists of (1) a table of the ATR power history and distribution, (2) a listing of the calculated thermal and fast neutron fluence rates, and (3) plots of calculated both the thermal and fast neutron fluence rates. The fluence rates reported are for the average power levels given in the table of power history and distribution. During the irradiation of Cycle 152A, the RML performed additional flux measurements to assess core reconfiguration issues. Measurements using cadmium covered as well as bare neutron monitors in the Southwest, Southeast, and H positions of the Center lobe were performed to determine the division in neutron energy between epithermal and thermal neutrons. This is defined as the resonance correction defined in this report. It is used to quantify both thermal and fast neutron flux. For more information please refer to letter, “RADIATION MEASUREMENTS LABORATORY MEASUREMENTS OF IN CORE ATR PHYSICS TESTING DURING CYCLE 152A” dated January 24, 2013, to Casey Stengel from C. C. Jensen. The measured values documented in RML Procedure, “ACMM-3600, Flux Monitoring,” will be used indefinitely until further measurements supersede the current values.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-Fluence Active Irradiation and Combined Effects Testing of Sapphire Optical Fiber Distributed Temperature Sensors

The goal of this work was to investigate the in-core performance of sapphire optical fiber temperature sensors and to develop clad sapphire optical fibers for in-core instrumentation. We fabricated clad sapphire optical fibers and evaluated the distributed sensing performance of these sensors via optical backscatter reflectometry under high fluence and combined radiation and temperature effects. A series of irradiations was completed to evaluate the effect of irradiation on sapphire optical fiber temperature sensors and to determine the operational limits of these sensors. (1) Objective 1: Fabricate sapphire optical fiber sensors. (2) Objective 2: Evaluate the clad sapphire fiber to verify single-mode behavior and determine and characterize the light modes supported by optical fibers. (3) Objective 3: Characterize the in-core temperature sensing of sapphire optical fiber, as well as the combined temperature and irradiation effects. (4) Objective 4: Evaluate the lifetime and performance of the sensor under irradiation to high neutron fluence. Objectives 1, 2, and 3 were completed during the first 2 years of the project. Due to the Covid pandemic, Objective 4, a high-fluence irradiation performed at the Massachusetts Institute of Technology Research Reactor (MITR), was delayed, as partner facilities were subject to mandatory shutdowns and required a 1 year, no-cost extension. This irradiation was eventually completed on December 12, 2022. This work indicates that sapphire optical fiber sensors may be a solution for ultra-high-temperature applications in which traditional silica optical fibers are prone to fail. Sapphire sensors are potentially suitable for experiments featuring temperatures above 700°C for long periods of time, or for any length of time above 1000°C. Experiments featuring a low total fluence, such as irradiations conducted in the Transient Reactor Test (TREAT) facility, also represent good applications for sapphire optical sensors. Additional work is required to characterize the sapphire fiber cladding performance, which falls outside the scope of this project, as well as the effects of high temperatures on the response of the fiber. A comprehensive material study is recommended as future work to evaluate the attenuation in sapphire under irradiation, and how that attenuation changes with irradiation temperature. The drift and attenuation in the fiber at temperatures of up to 1600°C and a total fluence of up to 2.9 x 10 17 n/cm 2 was minimal, and the fibers returned to baseline after being heated to 1600°C under irradiation. This is promising for the future use of sapphire optical fibers in advanced reactors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of mesopores in superfine grain graphite neutron-irradiated at high fluence

Microstructural changes induced by neutron irradiation of superfine grain graphite G347A (Tokai Carbon, Japan) were examined by nitrogen adsorption at 77K and by three microscopy techniques (SEM, TEM and FIB-SEM tomography). The specimens were irradiated at doses of up to 30 dpa, covering stages before and after the turnaround fluence at three temperatures (300, 450, 750 °C) of their irradiation envelope. The initial graphite densification at low fluences did not produce any detectable effect in the pore size range (<350 nm) measured by gas adsorption. However, graphite irradiated at high fluences, after turnaround, showed severe structural changes. At all three temperatures and high irradiation fluences, gas adsorption revealed significant increase of the volume of narrow mesopores (<5–20nm) and up to five times increase of BET surface area, both in linear relationship with the relative volume expansion. Analysis of microscopy images showed multiplication of fine macropores (>50 nm) at high irradiation fluences and more structural changes on multiple scales, from nanometers to microns. This work demonstrates the unique ability of gas adsorption techniques to analyze open pores with sizes between sub-nanometer and sub-micron in bulk nuclear graphite, with supporting microscopy results.

I. Contescu, Cristian↗

Measured Thermal and Fast Neutron Fluence Rates for aLEU Holders During Cycle 169A

This report contains the thermal (2200 mis) and fast (E> IMeV) neutron fluence rate data for the aLEU holders located in core for ATR Cycle 169A which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains measurements of the fluence rates corresponding to the particular elevations relative to the 80-ft. core elevation. The data in this report consist of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, and (3) plots of both the thermal and fast neutron fluence rates. All "BR" holder monitor wires for this cycle are 56.375 inches long. This length allows measurements from 31.17 inches above core midplane to 19.81 inches below core midplane. The distance from the end of the wires to the first count position was 4.25 inches for all wires counted from this cycle.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measured Thermal and Fact Neutron Fluence Rates for AFC Holders During Cycle 169A

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for the AFC holders located in core for ATR Cycle 169A which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains measurements of the fluence rates corresponding to the particular elevations relative to the 80-ft. core elevation. The data in this report consist of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, and (3) plots of both the thermal and fast neutron fluence rates. All "BR" holder monitor wires for this cycle are 56.375 inches long. This length allows measurements from 31.17 inches above core midplane to 19.81 inches below core midplane. The distance from the end of the wires to the first count position was 4.25 inches for all wires counted from this cycle.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Growth of deuterium supersaturated surface layer with increasing ion flux and fluence in plasma-exposed tungsten

Deuterium supersaturated surface layer (DSSL) in tungsten, a few nm thick layer exhibiting extremely high deuterium content (> 5%), has been studied as a function of deuterium plasma ion flux and fluence. Tungsten samples were exposed at 400 K and deuterium ion energy of ∼ 60 eV. The deuterium ion flux spanned over an order of magnitude, being 7.3 × 10 20 , 4.2 × 10 21 , and 3.8 × 10 22 D/m 2 . The fluence ranged from 3.4 × 1024 to 3.4 × 1025 D/m2. The samples and their deuterium content were analyzed by nuclear reaction analysis (NRA), scanning transmission electron microscopy (STEM), and thermal desorption spectroscopy (TDS). The largest thickness of DSSL was found to be around 10.5 nm and was observed in the case of the highest exposure flux and fluence, whereas the layer was only about 3.8 nm thick in the case of the lowest value of the two parameters. The thickness of the DSSL was found to monotonically increase with both deuterium flux and fluence. Finally, similar to the thickness, the estimated D concentration seems to follow the same trend, increasing from the lowest value of around 3 at.% to the highest value of around 5 at.%.

Deuterium↗

Jitter-induced Max-of-N fluence distribution at the National Ignition Facility

Max-of-N fluence is the maximum peak fluence at a given location over N number of shots and is important for calculating fluence dependence for intrinsic laser-induced optic damage. Previously, we observed the Max-of-N effect on the National Ignition Facility and developed an ad-hoc model to calculate its effect. In this work, we attempt to understand the fundamental mechanism that causes this Max-of-N effect. We conclude that the primary fundamental mechanism responsible for this effect is dominated by the combination of fluence variations and pointing jitter of the laser. This discovery both strengthens our model for predicting optics longevity and gives us insight into how to mitigate this effect.

42 ENGINEERING↗

On High-Fluence Irradiation Hardening of Nine RPV Surveillance Steels in the UCSB ATR-2 Experiment: Implications for Extended-Life Embrittlement Predictions

Nine archival reactor pressure vessel (RPV) surveillance steels from commercial nuclear power plants were irradiated in the University of California, Santa Barbara Advanced Test Reactor 2 (ATR-2) experiment to evaluate irradiation embrittlement under low-flux surveillance capsule versus higher flux test reactor (ATR-2) conditions. The postirradiation measurements of irradiation hardening, measured as increases in yield stress (Δσy), and corresponding conversions of Δσy to Charpy V-notch 41-J transition temperature shifts (ΔTc) are compared with various embrittlement trend curve (ETC) model predictions for the nine steels. Tensile and converted shear punch and microhardness measurements of Δσy generally show a continuing increase between intermediate and high ATR-2 fluences. The Eason-Odette-Nanstad-Yamamoto and ASTM E900 ETC models underpredict embrittlement at the ATR-2 irradiation condition: irradiation temperature (Ti) of 292°C, neutron fluence (ϕt) of 1.4 × 1020 n/cm2 (E > 1 MeV), and neutron flux (ϕ) of 3.68 × 1012 n/cm2-s. On average, the French FIS and Japanese JAEC ETCs slightly overpredict the ATR-2 data. The increase in Δσy with higher fluence is primarily due to Ni-Mn-Si precipitates, which slowly evolve in both nearly copper-free and copper-bearing steels. Finally, a new Odette-Wells-Almirall-Yamamoto embrittlement model is shown that yields good predictions for the nine steels at high fluences (ϕt > 5.5 × 1019 n/cm2).

Nanstad, Randy K.↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 167A

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 167A which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. The report contains fluence rate values corresponding to the particular elevations (relative to the 80-ft. core elevation) where the measurements were taken. The data in this report consists of (1) a table of the ATR power history and distribution, (2) a hard copy listing of all thermal and fast neutron fluence rates, (3) plots of both the thermal and fast neutron fluence rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measured Thermal and Fast Neutron Fluence Rates ATR Cycles 171A AFC (Rev. 1)

This report contains the thermal (2200 m/s) and fast (E>1MeV) neutron fluence rate data for ATR Cycle 171A AFC which were measured by the Radiation Measurements Laboratory (RML) as requested by the Power Reactor Programs (ATR Experiments) Radiation Measurements Work Order. This report contains fluence rate values corresponding to the particular elevations (relative to the 80-ft. core elevation) where the measurements were taken. The data in this report consists of (1) a table of the ATR power history and distribution, (2) a listing of the calculated thermal and fast neutron fluence rates, and (3) plots of calculated both the thermal and fast neutron fluence rates.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High Fluence 14 MeV Neutron Exposure Capability at the National Ignition Facility

Neutron experiments conducted at the National Ignition Facility can utilize high neutron fluences delivered in very short pulses. By adapting inertial confinement fusion laser pulses and targets, fluences above 10 15 n/cm 2 can be achieved on small experimental volumes, and prospectively up to 10 16 n/cm 2 onto capsule materials under development. Neutron pulse lengths are less than 1 ns. Large experimental volumes from 150 cm 3 to 20 L can access fluences of 10 8 -10 13 n/cm 2 . Experimental platforms may contain encapsulated hazardous materials, active electronics connected to sophisticated prompt read-out equipment, and large assemblies up to 200 kg. Furthermore, sources are designed to maximize total yield, total experimental fluence, or maximum fluenceper user-day allocated as required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On High-Fluence Irradiation Hardening of Nine RPV Surveillance Steels in the UCSB ATR-2 Experiment: Implications for Extended-Life Embrittlement Predictions

Nine archival reactor pressure vessel (RPV) surveillance steels from commercial nuclear power plants were irradiated in the University of California, Santa Barbara Advanced Test Reactor 2 (ATR-2) experiment to evaluate irradiation embrittlement under low-flux surveillance capsule versus higher flux test reactor (ATR-2) conditions. The postirradiation measurements of irradiation hardening, measured as increases in yield stress (Δσy), and corresponding conversions of Δσy to Charpy V-notch 41-J transition temperature shifts (ΔTc) are compared with various embrittlement trend curve (ETC) model predictions for the nine steels. Tensile and converted shear punch and microhardness measurements of Δσy generally show a continuing increase between intermediate and high ATR-2 fluences. The Eason-Odette-Nanstad-Yamamoto and ASTM E900 ETC models underpredict embrittlement at the ATR-2 irradiation condition: irradiation temperature (Ti) of 292°C, neutron fluence (ϕt) of 1.4 × 1020 n/cm2 (E > 1 MeV), and neutron flux (ϕ) of 3.68 × 1012 n/cm2-s. On average, the French FIS and Japanese JAEC ETCs slightly overpredict the ATR-2 data. The increase in Δσy with higher fluence is primarily due to Ni-Mn-Si precipitates, which slowly evolve in both nearly copper-free and copper-bearing steels. Finally, a new Odette-Wells-Almirall-Yamamoto embrittlement model is shown that yields good predictions for the nine steels at high fluences (ϕt > 5.5 × 1019 n/cm2).

Nanstad, Randy↗

Impact of Radial Reflector Fidelity on Neutronics and Vessel Fluence Simulations

The Consortium for Advanced Simulation of Light Water Reactors is developing the Virtual Environment for Reactor Applications (VERA), and the MPACT code, which is the primary deterministic neutron transport solver in VERA, provides sub-pin level flux and power distributions as part of full-scale cycle depletion and analysis. In such calculations, an important aspect is the radial reflector treatment. To improve the fidelity of the radial reflector treatment, MPACT was extended to approximate the modeling of the reactor’s structural components such as the core shroud, barrel, neutron pads, and vessel. This work explores several modeling configurations with varying levels of fidelity and computational burden and assesses the importance of modeling fidelity on the eigenvalue and pin power distribution. Two two-dimensional (2-D) problems were analyzed to assess the impact on eigenvalue and pin power distributions with low-fidelity, coarse square cell reflector representations: (1) a Watts Bar Nuclear Plant Unit 1 (WBN1) quarter-core slice with depletion and (2) an AP1000 quarter-core slice. In this work, the analyses showed that the effect on eigenvalue is fairly small, but the effect on pin power is more pronounced, especially locally in the assemblies closest to the periphery, where the maximum pin power difference is nearly 3.5% in the AP1000 case. Two additional 2-D problems were used to assess the comparison between the low-fidelity coarse square cell treatment and a high-fidelity geometric representation that uses subpin material specification: (1) the same WBN1 quarter-core slice and (2) a representative model of the NuScale small modular reactor (SMR), which features a solid reflector design with moderator holes. These results demonstrate that even a coarse, low-fidelity representation adequately captures the necessary simulation characteristics. Last, these capabilities were applied to the 2-D WBN1 quarter-core depletion to assess the impact on vessel fluence using VeraShift. From adjoint calculations, pins along the periphery were observed to be of highest importance for fluence calculation, so the impact of the reflector representation in MPACT could theoretically substantially affect the predicted result. However, it was observed that the change in pin powers along the periphery minimally impacts the maximum vessel fluence with a difference within the statistical uncertainty but provides terrific insight on the sensitivity of the peripheral pins.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗