Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fluorescence Detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Effect of Clouds on Apertures of Space-based Air Fluorescence Detectors

Space-based ultra-high-energy cosmic ray detectors observe fluorescence light from extensive air showers produced by these particles in the troposphere. Clouds can scatter and absorb this light and produce systematic errors in energy determination and spectrum normalization. We study the possibility of using IR remote sensing data from MODIS and GOES satellites to delimit clear areas of the atmosphere. The efficiency for detecting ultra-high-energy cosmic rays whose showers do not intersect clouds is determined for real, night-time cloud scenes. We use the MODIS SST cloud mask product to define clear pixels for cloud scenes along the equator and use the OWL Monte Carlo to generate showers in the cloud scenes. We find the efficiency for cloud-free showers with closest approach of three pixels to a cloudy pixel is 6.5% exclusive of other factors. We conclude that defining a totally cloud-free aperture reduces the sensitivity of space-based fluorescence detectors to unacceptably small levels.

Sokolsky, P.↗

Macro detection using fluorescence detectors

Macroscopic dark matter (aka macros) constitutes a broad class of alternatives to particulate dark matter. We calculate the luminosity produced by the passage of a single macro as a function of its physical cross section. A general detection scheme is developed for measuring the fluorescence caused by a passing macro in the atmosphere that is applicable to any ground based or space based Fluorescence Detecting (FD) telescopes. In particular, we employ this scheme to constrain the parameter space (σ x vs M x ) of macros than can be probed by the Pierre Auger Observatory and by the Extreme Universe Space Observatory onboard the Japanese Experiment Module (JEM-EUSO). It is of particular significance that both detectors are sensitive to macros of nuclear density, since most candidates that have been explored (excepting primordial black holes) are expected to be of approximately nuclear density.

79 ASTRONOMY AND ASTROPHYSICS↗

Limitations on Space-based Air Fluorescence Detector Apertures obtained from IR Cloud Measurements

The presence of clouds between an airshower and a space-based detector can dramatically alter the measured signal characteristics due to absorption and scattering of the photonic signals. Furthermore, knowledge of the cloud cover in the observed atmosphere is needed to determine the instantaneous aperture of such a detector. Before exploring the complex nature of cloud-airshower interactions, we examine a simpler issue. We investigate the fraction of ultra-high energy cosmic ray events that may be expected to occur in volumes of the viewed atmosphere non-obscured by clouds. To this end, we use space-based IR data in concert with Monte Carlo simulated 10(exp 20) eV airshowers to determine the acceptable event fractions. Earth-observing instruments, such as MODIS, measure detailed cloud configurations via a CO2-slicing technique that can be used to determine cloud-top altitudes over large areas. Thus, events can be accepted if their observed 3-dimensional endpoints occur above low clouds as well as from areas of cloud-free atmosphere. An initial analysis has determined that by accepting airshowers that occur above low clouds, the non-obscured acceptance can be increased by approximately a factor of 3 over that obtained using a cloud-free criterion.

White, Nicholas E.↗

Laser-excited fluorescence for measuring atmospheric pollution

System measures amount of given pollutant at specific location. Infrared laser aimed at location has wavelength that will cause molecules of pollutant to fluoresce. Detector separates fluorescence from other radiation and measures its intensity to indicate concentration of pollutant.

Menzies, R. T.↗

Mosaic-Detector-Based Fluorescence Spectral Imager

A battery-powered, pen-sized, portable instrument for measuring molecular fluorescence spectra of chemical and biological samples in the field has been proposed. Molecular fluorescence spectroscopy is among the techniques used most frequently in laboratories to analyze compositions of chemical and biological samples. Heretofore, it has been possible to measure fluorescence spectra of molecular species at relative concentrations as low as parts per billion (ppb), with a few nm spectral resolution. The proposed instrument would include a planar array (mosaic) of detectors, onto which a fluorescence spectrum would be spatially mapped. Unlike in the larger laboratory-type molecular fluorescence spectrometers, mapping of wavelengths to spatial positions would be accomplished without use of relatively bulky optical parts. The proposed instrument is expected to be sensitive enough to enable measurement of spectra of chemical species at relative concentrations <1 ppb, with spectral resolution that could be tailored by design to be comparable to a laboratory molecular fluorescence spectrometer. The proposed instrument (see figure) would include a button-cell battery and a laser diode, which would generate the monochromatic ultraviolet light needed to excite fluorescence in a sample. The sample would be held in a cell bounded by far-ultraviolet-transparent quartz or optical glass. The detector array would be, more specifically, a complementary metal oxide/ semiconductor or charge-coupled- device imaging photodetector array, the photodetectors of which would be tailored to respond to light in the wavelength range of the fluorescence spectrum to be measured. The light-input face of the photodetector array would be covered with a matching checkerboard array of multilayer thin film interference filters, such that each pixel in the array would be sensitive only to light in a spectral band narrow enough so as not to overlap significantly with the band of an adjacent pixel. The wavelength interval between adjacent pixels (and, thus, the spectral resolution) would typically be chosen by design to be approximately equal to the width of the total fluorescence wavelength range of interest divided by the number of pixels. The unitary structure comprising the photodetector array overlaid with the matching filter array would be denoted a hyperspectral mosaic detector (HMD) array.

Son, Kyung-Ah↗

Integration of EDWARD readout architecture in full-field fluorescence imaging detector

Data bandwidth, timing resolution and resource utilization in readouts of radiation detectors are a constant challenge. Event driven solutions are pushing against well-trenched framed solutions. The idea for an asynchronous readout architecture called EDWARD ( E vent- D riven W ith A ccess and R eset D ecoder) was presented at the TWEPP 2021 conference. Here we show the progress of our work which resulted in two chip prototypes. The first one, named 3FI65P1, is a full device with the analog pixel circuitry suited for full-field fluorescence imaging. It is already manufactured, and preliminary results are presented. Finally, the second chip, named EDWARD65P1, contains digital pulse generators with Poisson-exponential distribution in each pixel for extraction of the performance matrix of the EDWARD architecture alone.

47 OTHER INSTRUMENTATION↗

Direct measurement of the muonic content of extensive air showers between 2 $\times$ 10 17 and 2 $\times$ 10 18 eV at the Pierre Auger Observatory

The hybrid design of the Pierre Auger Observatory allows for the measurement of the properties of extensive air showers initiated by ultra-high energy cosmic rays with unprecedented precision. By using an array of prototype underground muon detectors, we have performed the first direct measurement, by the Auger Collaboration, of the muon content of air showers between 2 $\times$ 10 17 and 2 $\times$ 10 18 eV. We have studied the energy evolution of the attenuation-corrected muon density, and compared it to predictions from air shower simulations. The observed densities are found to be larger than those predicted by models. We quantify this discrepancy by combining the measurements from the muon detector with those from the Auger fluorescence detector at 10 17.5 eV and 10 18 eV. We find that, for the models to explain the data, an increase in the muon density of 38% $±$4%(12%) $±^{21\%}_{18\%}$ for EPOS-LHC, and of 50%(53%) $±$4%(13%) $±^{23\%}_{20\%}$ for QGSJETII-04, is respectively needed.

79 ASTRONOMY AND ASTROPHYSICS↗

High-resolution Elemental Mapping of the Lunar Surface

New instruments and missions are being proposed to study the lunar surface as a result of the resurgence of interest in returning to the Moon. One instrument recently proposed is similar in concept to the x-ray fluorescence detectors flown on Apollo, but utilizes fluorescence from the L- and M-shells rather than the K-shell. This soft X-Ray Flourescence Imager (XRFI) is discussed.

Edwards, Bradley C.↗

Search for photons above 10 18 eV by simultaneously measuring the atmospheric depth and the muon content of air showers at the Pierre Auger Observatory

The Pierre Auger Observatory is the most sensitive instrument to detect photons with energies above 1 0 17 eV . It measures extensive air showers generated by ultrahigh energy cosmic rays using a hybrid technique that exploits the combination of a fluorescence detector with a ground array of particle detectors. The signatures of a photon-induced air shower are a larger atmospheric depth of the shower maximum ( X max ) and a steeper lateral distribution function, along with a lower number of muons with respect to the bulk of hadron-induced cascades. In this work, a new analysis technique in the energy interval between 1 and 30 EeV ( 1 EeV = 1 0 18 eV ) has been developed by combining the fluorescence detector-based measurement of X max with the specific features of the surface detector signal through a parameter related to the air shower muon content, derived from the universality of the air shower development. No evidence of a statistically significant signal due to photon primaries was found using data collected in about 12 years of operation. Thus, upper bounds to the integral photon flux have been set using a detailed calculation of the detector exposure, in combination with a data-driven background estimation. The derived 95% confidence level upper limits are 0.0403, 0.01113, 0.0035, 0.0023, and 0.0021 km − 2 sr − 1 yr − 1 above 1, 2, 3, 5, and 10 EeV, respectively, leading to the most stringent upper limits on the photon flux in the EeV range. Compared with past results, the upper limits were improved by about 40% for the lowest energy threshold and by a factor 3 above 3 EeV, where no candidates were found and the expected background is negligible. The presented limits can be used to probe the assumptions on chemical composition of ultrahigh energy cosmic rays and allow for the constraint of the mass and lifetime phase space of super-heavy dark matter particles. Published by the American Physical Society 2024

79 ASTRONOMY AND ASTROPHYSICS↗

Method for determining surface coverage by materials exhibiting different fluorescent properties

An improved method for detecting, measuring, and distinguishing crop residue, live vegetation, and mineral soil is presented. By measuring fluorescence in multiple bands, live and dead vegetation are distinguished. The surface of the ground is illuminated with ultraviolet radiation, inducing fluorescence in certain molecules. The emitted fluorescent emission induced by the ultraviolet radiation is measured by means of a fluorescence detector, consisting of a photodetector or video camera and filters. The spectral content of the emitted fluorescent emission is characterized at each point sampled, and the proportion of the sampled area covered by residue or vegetation is calculated.

Chappelle, Emmett W.↗

MOD: An Organic Detector for the Future Exploration of Mars

The Mars Organic Detector (MOD) is designed to assess whether organic compounds, possibly associated with life, are present in Martian rock and soil samples. MOD has a detection limit that is at least two orders of magnitude more sensitive than the Viking GCMS. MOD is focused on detecting amino acids, amines and PAH (polycyclic aromatic hydrocarbons). Amino acids play an essential role in biochemistry on Earth and PAH are widespread throughout the universe and can provide an indication of the delivery of meteoritic organic material to Mars. The advantage of MOD is the absence of wet chemistry and its simple and robust design. The sample will be extracted from the mineral matrix (0.1 - 1 g of rock-powder) using sublimation and analyzed with a fluorescence detector. The isolation method is based on the fact that amino acids and PAH are volatile at temperatures greater than 150C. The fluorescence detection scheme is based on UV excitation with LED's, optical filters, PrN diode photon detector and a sample calibration reservoir. Fluorescamine is used as a fluorescing reagent for amino acids and amines, while PAH are naturally fluorescent. There is no sample preparation required and the turnaround time for a single analysis is on the order of minutes.

Kminek, G.↗

Measurement of the depth of maximum of air-shower profiles with energies between 10 18.5 and 10 20 eV using the surface detector of the Pierre Auger Observatory and deep learning

We report an investigation of the mass composition of cosmic rays with energies from 3 to 100 EeV ( 1 EeV = 10 18 eV ) using the distributions of the depth of shower maximum X max . The analysis relies on ∼ 50 , 000 events recorded by the surface detector of the Pierre Auger Observatory and a deep-learning-based reconstruction algorithm. Above energies of 5 EeV, the dataset offers a 10-fold increase in statistics with respect to fluorescence measurements at the Observatory. After cross-calibration using the fluorescence detector, this enables the first measurement of the evolution of the mean and the standard deviation of the X max distributions up to 100 EeV. Our findings are threefold: (i) The evolution of the mean logarithmic mass toward a heavier composition with increasing energy can be confirmed and is extended to 100 EeV. (ii) The evolution of the fluctuations of X max toward a heavier and purer composition with increasing energy can be confirmed with high statistics. We report a rather heavy composition and small fluctuations in X max at the highest energies. (iii) We find indications for a characteristic structure beyond a constant change in the mean logarithmic mass, featuring three breaks that are observed in proximity to the ankle, instep, and suppression features in the energy spectrum. Published by the American Physical Society 2025

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tre-DST: A Drug Susceptibility Test for Mycobacterium tuberculosis Using Solvatochromic Trehalose Probes

In 2024, an estimated 10 million people developed Tuberculosis (TB), nearly half a million of whom were infected with drug-resistant tuberculosis (DR-TB). Early detection of infection and drug resistance enables rapid engagement in effective care. Bacterial culture and nucleic acid testing remain the primary diagnostic methods, with smear microscopy being phased out. However, these methods present significant limitations for diagnosing drug resistance, such as lengthy time-to-result for phenotypic tests, as well as the need for prior knowledge of resistance mutations and prohibitive cost for molecular tests. To address this, we developed a rapid phenotypic TB drug susceptibility test, termed Tre-DST, based on novel metabolically incorporated trehalose probes, which specifically detect live mycobacteria. We used the nonpathogenic Mycobacterium smegmatis and the virulence-attenuated Mycobacterium tuberculosis (Mtb) H37Ra or auxotrophic Mtb to demonstrate a strong correlation between cost-effective plate reader results and flow cytometry data, suggesting that the plate reader is a suitable fluorescence detector for Tre-DST. We determined that adding a 1-week incubation step allowed Mtb samples originally seeded at 10 4 CFU/mL to become detectable, over 2 weeks earlier than colony-forming unit analysis. We found that Tre-DST reports on drug susceptibility in a drug-agnostic manner, demonstrating loss of fluorescence with frontline TB drugs as well as the newer drug bedaquiline. Tre-DST distinguished RIF- and INH-resistant auxotrophs from susceptible controls and accurately reported the resistance activity. Ultimately, because Tre-DST is agnostic to mechanisms of drug resistance, this assay is likely compatible with all WHO-recommended and future DR-TB drugs as a diagnostic in reference laboratories.

diagnostics↗

Inference of the Mass Composition of Cosmic Rays with Energies from 10 18.5 to 10 20 eV Using the Pierre Auger Observatory and Deep Learning

We present measurements of the atmospheric depth of the shower maximum X max , inferred for the first time on an event-by-event level using the surface detector of the Pierre Auger Observatory. Using deep learning, we were able to extend measurements of the X max distributions up to energies of 100 EeV ( 10 20 eV ), not yet revealed by current measurements, providing new insights into the mass composition of cosmic rays at extreme energies. Gaining a 10-fold increase in statistics compared to the fluorescence detector data, we find evidence that the rate of change of the average X max with the logarithm of energy features three breaks at 6.5 ± 0.6 ( stat ) ± 1 ( syst ) EeV , 11 ± 2 ( stat ) ± 1 ( syst ) EeV , and 31 ± 5 ( stat ) ± 3 ( syst ) EeV , in the vicinity to the three prominent features (ankle, instep, suppression) of the cosmic-ray flux. The energy evolution of the mean and standard deviation of the measured X max distributions indicates that the mass composition becomes increasingly heavier and purer, thus being incompatible with a large fraction of light nuclei between 50 and 100 EeV. Published by the American Physical Society 2025

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray multi-probe data acquisition: A novel technique for laser pump x-ray transient absorption spectroscopy

We report the development and implementation of a novel data acquisition (DAQ) technique for synchrotron-based laser pump X-ray Transient Absorption (XTA) spectroscopy, called X-ray Multi-Probe DAQ (XMP DAQ). This technique utilizes high performance analog to digital converters and home-built software to efficiently measure and process the XTA signal from all x-ray pulses between laser excitations. XMP DAQ generates a set of time resolved x-ray absorption spectra at thousands of different pump–probe time delays simultaneously. Two distinct XMP DAQ schemes are deployed to accommodate different synchrotron storage ring filling patterns. Current Integration (CI) DAQ is a quasi-analog technique that implements a fitting procedure to extract the time resolved absorption intensity from the averaged fluorescence detector response. The fitting procedure eliminates issues associated with small drifts in the voltage baseline and greatly enhances the accuracy of the technique. Photon Counting (PC) DAQ is a binary technique that uses a time resolved histogram to calculate the XTA spectrum. While PC DAQ is suited to measure XTA data with closely spaced x-ray pulses (~10 ns) and a low count rate (<1 detected photon/pulse), CI DAQ works best for widely spaced pulses (tens of ns or greater) with a high count rate (>1 detected photon/pulse). XMP DAQ produces a two-dimensional XTA dataset, enabling efficient quantitative analysis of photophysical and photochemical processes from the sub-nanosecond timescale to 100 μs and longer.

47 OTHER INSTRUMENTATION↗

The hydrogen bond between tryptophan and the host molecule induced fluorescence enhancement

Abstract Tryptophan is one of important amino acids in the human body, therefore its detection is particularly important. The 3,5‐bis(4‐pyridyl)‐4‐amino‐1,2,4‐triazole (BPAT) organic molecule was designed to be used as fluorescence detectors to detect tryptophan molecules for the interaction between the host and the guest. BPAT shows good sensitivity and selectivity towards tryptophan compared with other amino acid molecules. The limit of detection obtained from formula 3δ/K SV is considered to be 5.43 × 10 −7 mol/L. We speculated that this change is mainly caused by the hydrogen bond between tryptophan and the host molecule BPAT. This conjecture was verified by the controlled experiments with other host molecules.

Yang, Xi↗

A 3-Year Sample of Almost 1,600 Elves Recorded Above South America by the Pierre Auger Cosmic-Ray Observatory

Elves are a class of transient luminous events, with a radial extent typically greater than 250 km, that occur in the lower ionosphere above strong electrical storms. We report the observation of 1,598 elves, from 2014 to 2016, recorded with unprecedented time resolution (100 ns) using the fluorescence detector (FD) of the Pierre Auger Cosmic-Ray Observatory. The Auger Observatory is located in the Mendoza province of Argentina with a viewing footprint for elve observations of 3∙10sup>6 km ₂, reaching areas above the Pacific and Atlantic Oceans, as well as the Córdoba region, which is known for severe convective thunderstorms. Primarily designed for ultrahigh energy cosmic-ray observations, the Auger FD turns out to be very sensitive to the ultraviolet emission in elves. The detector features modified Schmidt optics with large apertures resulting in a field of view that spans the horizon, and year-round operation on dark nights with low moonlight background, when the local weather is favorable. The measured light profiles of 18% of the elve events have more than one peak, compatible with intracloud activity. Within the 3-year sample, 72% of the elves correlate with the far-field radiation measurements of the World Wide Lightning Location Network. The Auger Observatory plans to continue operations until at least 2025, including elve observations and analysis. To the best of our knowledge, this observatory is the only facility on Earth that measures elves with year-round operation and full horizon coverage.

79 ASTRONOMY AND ASTROPHYSICS↗

Mapping of the HIDRA stellarator magnetic flux surfaces

The Hybrid Illinois Device for Research and Applications (HIDRA) is a classical stellarator designed for conducting plasma material interaction experiments and developing novel Plasma Facing Components (PFCs). Notably, the testing of two open-channel liquid lithium PFCs is imminent. Determining the shape of the plasma and its magnetic structure inside HIDRA is essential to carry out these tests. For this, electron traces were captured to build up the images of the HIDRA magnetic flux surfaces for several magnetic configurations, following the same procedure previously employed on the WEGA stellarator coupling an electron gun with a fluorescent detector. The FIELDLINES code has then been used to generate computational surfaces matching the experimental results. The obtained surfaces were found to be subject to a similar n = 1 error field as the one observed on WEGA, suggesting that the origin of this error field is inherent to the HIDRA vacuum vessel. Also, the effect of adding a vertical field was investigated, demonstrating the ability to radially shift the magnetic axis and move to a regime free of low-order rational resonances. Finally, this additional control over the HIDRA plasma and magnetic structure allows more freedom in setting up the PFC tests in the limiter and divertor regions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗