High-Fidelity CFD Simulation of Mixed Convection and Forced Convection in a Pebble Bed Test Reactor Core

The Hermes low-power [35-MW(thermal)] reactor will be built and operated by Kairos Power LLC (KP) to demonstrate its fluoride salt-cooled high-temperature reactor (FHR) technology. In the KP FHR, the reactor core is composed of randomly packed pebbles with TRISO fuel particles inside with FLiBe flow upward through the core acting as a coolant. Previous numerical and experimental studies have been limited to either a small-size bed or to a lack of detailed measurements for heat transfer. Here, to address the lack of high-fidelity heat transfer data in a real-size FHR core, in this study, we simulated a pebble bed core with 34 374 pebbles randomly packed, similar to the Hermes reactor's size. The core radius was 14 times that of the pebble diameter, while the core height was 45 times. In this work, we were particularly interested in a mixed convection regime, where buoyancy is important. Therefore, we performed several large-eddy simulations at different Reynolds numbers (160 to 1000) with gravitational force included. The spectral element computational fluid dynamics code NekRS with graphics processing unit acceleration was used for this study. The low-Mach number approximation was applied to address property changes in the FLiBe and to account for buoyancy. A pure hexahedral mesh with 60 million elements was generated by the Voronoi cell method. At the polynomial order of 5, the total degrees of freedom was 7.5 billion. The developed case in this work is the first of its kind in terms of size and complexity. The local numerical data across the domain were obtained and compared with empirical correlations. After examining the data, we found the following conclusions. For pressure drop, the Reger correlation predicted less than a 5% error. On the other hand, for heat transfer, the Wakao correlation outperformed the others. Based on our findings, we recommend the use of the Wakao correlation for the Nusselt number calculation, and for pressure drop, the KTA (Kerntechnischer Ausschuss) correclation, among the available experimental correlations. In conclusion, the Reger direct numerical simulation-driven correlation for pressure drops should also be considered, given its best agreement with our calculations.

Mixed Convection↗

Comparative Thermal Performance of Downdraft and Updraft Forced Convection in a Representative 3x3 PWR Fuel Assembly

A plethora of theoretical, numerical, and experimental investigations have relied on updraft forced convection of operating fuel assemblies for light water-cooled fuel assemblies. The inertial scales of turbulence in updraft flow through PWR fuel assemblies are primarily influenced by upstream mixing patterns within the lower plenum and consequent acceleration of flow through the lower core and support plates into the bottom nozzles. In secondary heat transfer applications such as steam generation, recuperation and economization, downdraft flow is utilized to retrieve maximal sensible heat from the primary coolant. Sub-channel volumes aligned vertically could also benefit from force of gravity in developing turbulent flows. A large reduction in pumping power, associated cost of operation and maintenance, and improved balance of plant is suggested to be possible through downdraft forced convection in PWR-type reactors. This article explores the impact of downdraft forced convection within the well-studied 3x3 sub-channel within a range of 20 hydraulic diameters across a representative intermediate flow mixing grid. A range of inflow Reynolds number from 10,000 to 60,000 is simulated over a range of equivalent heat loads of 20% to 100% spanning 20 hydraulic diameters. The fuel rods are represented in true geometric detail, and a constant-value heat profile is assumed for the investigation. At each inflow condition, the turbulence intensity, peak velocity, local heat transfer coefficient, peak wall heat flux, and peak wall temperature are collected across the sub-channel and compared with an updraft configuration evaluated at the same conditions.

Rao, Vivek↗

Start-up Operation Experience with a Liquid Fluoride Salt Forced Convection Loop

A liquid fluoride salt forced convection test loop was constructed at Oak Ridge National Laboratory. Its unique features include a pebble bed test section, high-temperature instrumentation, a noncontact rotating gas seal for the pump, a silicon carbide flow tube, and a unique inductive heating technique. Initial startup and shake-down testing has been completed. This paper describes how several of the systems performed, highlights those that worked well, and discusses issues that arose during the start-up process. This discussion should be of interest to those who intend to develop molten salt technologies and who are interested in some of the specific techniques used in this experiment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Data-Driven RANS Turbulence Closures for Forced Convection Flow in Reactor Downcomer Geometry

Recent progress in data-driven turbulence modeling has shown its potential to enhance or replace traditional equation-based Reynolds-averaged Navier-Stokes (RANS) turbulence models. Here, this work utilizes invariant neural network (NN) architectures to model Reynolds stresses and turbulent heat fluxes in forced convection flows (when the models can be decoupled). As the considered flow is statistically one dimensional, the invariant NN architecture for the Reynolds stress model reduces to the linear eddy viscosity model. To develop the data-driven models, direct numerical and RANS simulations in vertical planar channel geometry mimicking a part of the reactor downcomer are performed. Different conditions and fluids relevant to advanced reactors (sodium, lead, unitary-Prandtl-number fluid, and molten salt) constitute the training database. The models enabled accurate predictions of velocity and temperature, and compared to the baseline k–τ turbulence model with the simple gradient diffusion hypothesis, do not require tuning of the turbulent Prandtl number. The data-driven framework is implemented in the open-source graphics processing unit–accelerated spectral element solver nekRS and has shown the potential for future developments and consideration of more complex mixed convection flows.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-fidelity forced convection simulations of the University of Wisconsin–Madison air-cooled reactor cavity cooling system

Among the various types of advanced nuclear technologies that exist, high-temperature gas-cooled reactors (HTGRs) stand out for their co-generation capabilities and exceptional passive safety systems. HTGRs rely on a reactor cavity cooling system (RCCS) to remove decay heat from the reactor pressure vessel (RPV) during the course of long-term transients. Several studies have focused on experimental and numerical modeling of the RCCS; however, the literature reveals a notable gap when it comes to high-fidelity simulations such as direct numerical simulations (DNS) or large eddy simulation (LES) models of the RCCS. An LES model was developed for forced convection inside the RCCS so as to obtain a high-fidelity representation of the RCCS at a scale never before attempted. Furthermore, the LES model was compared against three different Reynolds-averaged Navier–Stokes (RANS) models (Realizable k − ϵ, k − ω SST, and Reynolds stress model [RSM]). This comparison verified the robustness and accuracy of the turbulence modeling approach of the RANS models for the RCCS. Finally, based on the comparison between the LES and the RANS models, the k − ω SST RANS model of the experimental facility was developed and compared against the available experimental data.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Role of Three-Dimensional Swirl in Forced Convection Heat Transfer Enhancement in Wavy-Plate-Fin Channels

The influence of wall-corrugation-induced swirl flow on enhanced forced convection in wavy-plate-fin cores has been investigated. Three-dimensional computational simulations were carried out for steady-state periodically developed air flow (Pr ~ 0.71; 50 ≤ Re ≤ 4000) with channel walls subject to constant-uniform temperature conditions. The recirculation that develops in the wall troughs and grows to have an axially helical character is scaled by the Swirl number Sw. As Sw increases with higher flowrate and/or corrugation severity, tornado-shaped vortices appear in the wave trough region midway of the interfin channel height, then extend longitudinally to encompass majority of the flow channel. The local wall-shear and heat transfer coefficient variations indicate that boundary-layer thinning upstream of the wave peak aids in intensifying momentum and heat transfer. However, the flow recirculation in wall trough impedes heat transfer at low Sw due to flow stagnation but promotes it at high Sw because of the vortices-induced augmented fluid mixing. The effects of this secondary flow are quantified by Φf(or j), which is seen to increase log-linearly as fin corrugation aspect ratio γ and/or fin spacing ratio ζ increases; the influence of cross section aspect ratio α is marginal. Moreover, the pressure drag penalty due to swirl critically affects overall pressure loss, and its proportion remains nearly constant when α varies, but grows as Sw, γ, and/or ζ increases and can be as much as 80% of the total pressure drop.

Engineering↗

Diurnal MCSs Precede the Genesis of Tropical Cyclone Mora (2017): The Role of Convectively Forced Gravity Waves

In this work, a novel high-resolution regional reanalysis is used to investigate the mesoscale processes that preceded the formation of Tropical Cyclone (TC) Mora (2017). Both satellite observations and the regional reanalysis show early morning mesoscale convective systems (MCSs) persistently initiated and organized in the downshear quadrant of the preexisting tropical disturbance a few days prior to the genesis of TC Mora. The diurnal MCSs gradually enhanced the meso-α-scale vortex near the center of the preexisting tropical disturbance through vortex stretching, providing a vorticity-rich and moist environment for the following burst of deep convection and enhancement of the meso-β-scale vortex. The regional reanalysis shows that the gravity waves that radiated from afternoon convection over the northern coast of the Bay of Bengal might play an important role in modulating the diurnal cycle of pregenesis MCSs. The diurnal convectively forced gravity waves increased the tropospheric stability, reduced the column saturation fraction, and suppressed deep convection within the preexisting tropical disturbance from noon to evening. A similar quasi-diurnal cycle of organized deep convection prior to TC genesis has also been observed over other basins. However, modeling studies are needed to conclusively demonstrate the relationships between the gravity waves and pregenesis diurnal MCSs. Also, whether diurnal gravity waves play a similar role in modulating the pregenesis deep convection in other TCs is worth future investigations.

54 ENVIRONMENTAL SCIENCES↗

Characterization and Scaling of Forced Convective Swirl in Sinusoidal Wavy-Plate-Fin Cores of Compact Heat Exchangers

The characterization and scaling of the thermal-hydraulic performance in wavy plate-fin compact heat exchanger cores, based on the understanding of the physical phenomena and heat transfer enhancement mechanism is delineated. Experimental data are presented for forced convection in air (Pr = 0.71) with flow rates in the range 50 ≤ Re ≤ 4000. A variety of wavy-fin cores that span viable applications, with geometrical attributes described by the cross section aspect ratio α (ratio of fin spacing to height), fin corrugation aspect ratio γ (ratio of 2× corrugation amplitude to wave pitch), and fin spacing ratio ζ (ratio of fin spacing to wave pitch), are considered. To characterize and correlate the vortex-flow mixing in interfin spaces, a Swirl number Sw is introduced from the balance of viscous, inertial and centrifugal forces. It is shown that the laminar, transitional and turbulent flow regimes can be explicitly identified by this Swirl number. Based on the experimental results and extended analysis, new correlations for Fanning friction factor f and Colburn factor j are developed with Sw, α, γ, and ζ as scaling parameters. Requisite expressions are devised by a superposition of both enhancement components due to the corrugated surface area enlargement and induced swirl flow field, and they are combined to cover the laminar, transitional and turbulent regimes by the method of asymptotic matching. The resulting generalized correlations are further shown to predict all available experimental data for f and j factors to within ±20% and ±15%, respectively.

42 ENGINEERING↗

Convectively Forced Diurnal Gravity Waves in the Maritime Continent

Long-lived, zonally propagating diurnal rainfall disturbances are a highly pronounced and common feature in the Maritime Continent (MC). A recent study argues that these disturbances can be explained as diurnally phase-locked gravity waves. Here we explore the origins of these waves through regional cloud-permitting numerical model experiments. The gravity waves are reproduced and isolated in the model framework through the combined use of realistic geography and diurnally cyclic lateral boundary conditions representative of both characteristic easterly and westerly background zonal flow regimes. These flow regimes are characteristic of the Madden–Julian oscillation (MJO) suppressed and active phase in the MC, respectively. Tests are conducted wherein Borneo, Sumatra, or both islands and/or their orography are removed. These tests imply that the diurnal gravity waves are excited and maintained directly by latent heating from the vigorous mesoscale convective systems (MCSs) that form nocturnally in both Borneo and Sumatra. Removing orography has only a secondary impact on both the MCSs and the gravity waves, implying that it is not critical to these waves. We therefore hypothesize that diurnal gravity waves are fundamentally driven by mesoscale organized deep convection, and are only sensitive to orography to the measure that the convection is affected by the orography and its mesoscale flows. Factor separation further reveals that the nonlinear interaction of synchronized diurnal cycles in Sumatra and Borneo slightly amplifies this gravity wave mode compared to if either island existed in isolation. This nonlinear feedback appears most prominently at longitudes directly between the two islands.

Ruppert, Jr., James H.↗

How equation of state selection impacts accuracy near the critical point: Forced convection supercritical CO 2 flow over a cylinder

Increasing application of supercritical fluids leads to increased use of numerical simulations to guide designs. However, the impact of Equations of State (EoS) selection on computational cost and accuracy is not well understood. Laminar flow around a heated cylinder is used as a test case. A robust matrix of 99-simulations is used to analyze the flow of carbon dioxide just above the critical point at the isobaric condition of 8 MPa and temperatures between 305 and 390 K. Four EoS were studied: Ideal Gas Law, cubic EoS’s Peng-Robinson and Soave-Redlich-Kwong, and the Span-Wagner EoS. Results were identical for isothermal cases, but for heated or cooled cases, the high-fidelity Span-Wagner EoS simulations presented drastically different wake structures. Compared to the high-fidelity SW EoS, cEoS’s underestimated Nu values by up to 38% and cEoS’s underestimated CD values by 18–42%. In conclusion, the Span-Wagner EoS required only 17% more computation time then the cubic EoS simulations, making the Span-Wagner EoS recommended for engineering design.

42 ENGINEERING↗

Dielectric Fluids for the Direct Forced Convection Cooling of Power Electronics

The future of electrification of vehicles and other systems will require the creation of high-power density power electronics with low junction-to-fluid thermal resistance cooling solutions. One way to create this solution is to move high-heat-flux liquid cooling (single- or two-phase) as close to the power electronics components as possible. One novel approach involves submersion in dielectric fluids as the cooling solution. We first provide the range of fluid properties and develop a figure of merit (FOM) to aid in dielectric fluid selection. Next, we perform computational fluid dynamics/heat transfer (CFD/HT) modeling using single-phase cooling (submerged jet impingement on an enhanced surface) to validate the dielectric fluid FOM. Results of the study show that the developed FOM is a good representation of the performance of the fluids when compared to the results of the CFD/HT analysis. Both FOM and the CFD/HT analysis show that based on pure thermohydraulic considerations, several commercially available fluids present higher performance, on the order of 5% of water. Finally, the FOM can be used to quickly assess the thermohydraulic performance of a dielectric fluid, as well as the secondary application-specific properties such as boiling point, saturation pressure, flash point, and global warming potential, thereby allowing for fluid candidates to be readily compared.

computational fluid dynamics↗

Cooling performance of an active-passive hybrid composite phase change material (HcPCM) finned heat sink: Constant operating mode

Here, the present study explores a hybrid thermal management technology based on air cooling and hybrid composite phase change material (HcPCM) filled finned heat sink for cooling performance of lower to medium heat flux dissipating electronic devices. Two-dimensional numerical simulations are conducted to study the conjugate heat transfer effects of three types of finned heat sink: air-cooled finned heat sink, HcPCM-cooled finned heat sink, and hybrid (air-HcPCM) cooled finned heat sink. A heat sink with a constant volume faction of plate-fins is designed in all cases and simultaneous effects of hybrid nanoparticles and air are investigated to keep the heat sink temperature at safe operating conditions between 40–60°C. The effect of air is incorporated into the heat sink by applying the convective heat transfer coefficient of h c = 10–100W /m 2 .K which tends to create the natural convection and forced convection heat transfer characteristics. The heat flux is varied from 25–40kW /m 2 in the current study. The hybrid nanoparticles of carbon additives (GO and MWCNTs) are dispersed into the RT-35HC, used as a PCM, with a volume fraction of 0% to 6%. Transient simulations are carried out using COMSOL Multiphysics to solve the governing equations for PCM based conjugate heat transfer model. The results showed that forced convection heat transfer improved the cooling performance of the hybrid heat sink compared to natural convection heat transfer. The addition of nanoparticles further enhanced thermal enhancement and uniform melting distribution of PCM inside the finned heat sink. The h c between 30 to 50W/m 2 .K shows optimized values for forced convection heat transfer operating conditions. The volume fraction of 2% of GO+MWCNTs nanoparticles in recommended or optimum concentration for uniform melting of PCM inside the finned heat sink.

36 MATERIALS SCIENCE↗

In-situ thermal transport measurement of flowing fluid using modulated photothermal radiometry

In situ thermal transport measurement of flowing fluid could be useful for the characterization and diagnosis of practical thermal systems such as fluid heat exchangers and thermal energy storage systems. Despite abundant reports on the ex-situ thermal conductivity measurement of stagnant fluids, a suitable technique for the thermal conductivity measurement of flowing fluid has been rarely reported. Here, this paper presents the thermal conductivity measurement of flowing fluid within a pipe using a non-contact modulated photothermal radiometry (MPR) technique, where the surface of the pipe is heated by an intensity-modulated laser and the heat diffuses into the fluid with suitable modulation frequency. We design a tube section with small wall thickness suitable for the MPR measurements to maximize the sensitivity of the thermal response to the fluid properties while minimizing the lateral heat spreading effect. Intrinsic thermal conductivity of different fluids was obtained within a proper range of frequency and flow velocity where the forced convection effect is negligible. The forced convection effect became prominent at high flowing velocity and at low modulation frequency, leading to higher effective thermal conductivity of the fluid. It is found that the intrinsic thermal conductivity could be obtained when the flow velocity is less than 100 mm/sec and Re D 1/2 Pr 1/3 < 100 for DI water and Xceltherm oil under the specified experimental conditions, where Re D is the Reynolds number and Pr is the Prandtl number.

42 ENGINEERING↗

Effects of excess Te on flux inclusion formation in the growth of cadmium zinc telluride when forced melt convection is applied

The presence of second phase defects, particularly flux inclusions of tellurium rich composition, are of great concern for charge collection efficiency in cadmium zinc telluride (CZT) and cadmium telluride (CT) material intended for applications such as radiation detection. These inclusions can distort applied electric field lines within the detector as well as act as trapping centers for charge carriers. Reduction and/or elimination of these inclusions is required to achieve appropriate charge collection efficiencies, especially in detectors of thicknesses greater than 5 mm. These so-called flux inclusions are understood to form as a consequence of constitutional undercooling at the crystal growth interface. In this study, a forced melt convection technique was applied in Vertical Bridgman (VB) melt growth of CZT without reducing imposed growth rates of ~2 mm/hr. Several rotation profiles were tested while adjusting the melt composition from 51.62 to 61.75 atomic percent (at%) Te where the Te concentration was initially increased to improve overall material purity. With forced melt convection, the best inclusion distributions were achieved with highly Te rich melt compositions, far beyond the stoichiometric composition range for the CZT system. Average inclusion diameters were reduced to 2 µm while inclusions greater than 5 µm were essentially eliminated. Composition analyses of these ingots revealed near equilibrium concentrations of Te, even with ingots grown from Te concentrations as high as 61.75 at% Te. In this paper, a recipe for the reduction of inclusions in CZT melt growth is put forward and the implications of this method on our understanding of inclusion formation are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiative heat transfer in FLiBe molten salt participating medium in a vertical heated tube under forced and mixed convection laminar flows

The contribution of radiative heat transfer (RHT) to convective heat transfer in a heated vertical pipe with laminar flow and constant wall temperature, for FLiBe molten salt, is investigated computationally. The combined effects of conduction in the fluid, forced convection, buoyancy, temperature-dependent physical properties, and thermal radiation are investigated. The P1 approximation is employed in the discretization of the Radiative Transfer Equation (RTE). The COMSOL Multiphysics software is used to generate the numerical solutions. The theoretical analysis developed here demonstrates that only for intermediate values of the optical thickness, i.e. τ D ~ O 1 , the participating media effects are expected to be important. This analysis is confirmed computationally and a value of τ D ≈ 4 is shown to lead to the highest increase in overall heat transfer behavior. Under forced convection, the Nusselt ratio N u total / N u no - rad reaches a peak value of 1.76 at τ D = 4 and z/D = 200 , and is less than 1.1 for τ D < 0 . 1 and τ D > 60 . Under aiding-flow mixed convection, N u total / N u no - rad reaches a peak of 1.34 at τ D = 4 . 2 and is less than 1.1 for τ D < 0 . 4 and τ D > 36 . Under opposing-flow mixed convection, Nu total / Nu no - rad reaches a peak of 1.81 at τ D = 4 . 2 and is less than 1.1 for τ D < 0 . 2 and τ D > 50 . RHT effects on the overall heat transfer are most pronounced in opposing mixed convection, where N u total / N u no - rad is 2.26 observed at z/D = 50 . The sensitivity to wall emissivity is evaluated; in forced convection, the peak N u total / N u no - rad is 1.66 at ε = 0 (reflective wall) and 2.04 at ε = 1 (absorptive wall). Finally, the sensitivity to pipe diameter is also discussed. Overall, for a vertical heated tube, radiative heat transfer effects lead to enhancement of heat transfer by as high as a factor of two, and they depend on the optical thickness of the flow, mixed convection environment ( Gr / R e 2 and direction of flow relative to the gravitational force), surface emissivity, and entrance effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assessment of the Loss of Vacuum on the Local Metal Temperature in the TEX Experiment Assembly

A four-part assessment using analytical methods and semi-analytical simulation tools finds that the maximum temperature variation in the highly enriched uranium (HEU) Jemima plate assembly is less than ten Kelvin (< 10 K) in an abrupt loss of vacuum scenario. The temperature variation in the metals is likely to be one to four Kelvin (1 K – 4 K) based on the most realistic conditions in the assessment. The four assessment parts include: (1) the peak gas temperature bound for the initial influx of the ambient air; (2) the high-heat transfer limit during the high-speed forced convection period in an insulated HEU plate; (3) the high-heat transfer limit during the high-speed forced convection period with aluminum spacers; and (4) the longer-time thermal equilibration period between the air and metal stack. The four-part assessment serves as conservative upper bound on the temperature variation in the metal stack and remains well below the 40 Kelvin limit where the temperature-induced stresses could lead to permanent, plastic deformation.