Search NASA⌕ Search

SEARCH · Search NASA

Results for “Forest Fires”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The Impacts of Recent Drought on Fire, Forest Loss, and Regional Smoke Emissions in Lowland Bolivia

In the southern Amazon relationships have been established among drought, human activities that cause forest loss, fire, and smoke emissions. We explore the impacts of recent drought on fire, forest loss, and atmospheric visibility in lowland Bolivia. To assess human influence on fire, we consider climate, fire, and vegetation dynamics in an area largely excluded from human activities since 1979, Noel Kempff Mercado National Park (NK) in northeastern Bolivia. We use data from five sources: the Moderate Resolution Imaging Spectroradiometer Collection 6 active fire product (2001-2015) (MODIS C6), Global Fire Weather Database (GFWED) data (1982-2015), MODIS land cover data (2001-2010), MODIS forest loss data (2000-2012), and the regional extinction coefficient for the southwestern Amazon (i.e., B(sub ext)), which is derived from horizontal visibility data from surface stations at the World Meteorological Organization (WMO) level (1973-2015). The B(sub ext) is affected by smoke and acts as a proxy for visibility and regional fire emissions. In lowland Bolivia from 2001 to 2015, interannual Drought Code (DC) variability was linked to fire activity, while from 1982 to 2015, interannual DC variability was linked to B(sub ext). From 2001 to 2015, the B(sub ext) and MODIS C6 active fire data for lowland Bolivia captured fire seasonality, and covaried between low- and high-fire years. Consistent with previous studies, our results suggest B(sub ext)t can be used as a longer-term proxy of regional fire emissions in southwestern Amazonia. Overall, our study found drought conditions were the dominant control on interannual fire variability in lowland Bolivia, and fires within NK were limited to the Cerrado and seasonally inundated wetland biomes. Our results suggest lowland Bolivian tropical forests were susceptible to human activities that may have amplified fire during drought. Human activities and drought need to be considered in future projections of southern Amazonian fire, in regard to carbon emissions and global climate.

Forest Loss↗

Remote Sensing of Forest Fires from Space

Forest fires, and fires used for deforestation and agriculture are sporadic. Some may last an hour others several days. It is difficult to find the fires or to estimate their effect on atmospheric pollution without an "eye in the sky" a satellite or an array of satellites that monitors them routinely from space. Since fires have a significant effect on the quality of air that we breath, on the surface vegetation, on clouds and precipitation and even on climate, NASA and other space agencies try to develop fire monitoring capability from space. Presently satellites were not designed to monitor fires. But the AVHRR and GOES satellites were used for fire monitoring. AVHRR is an orbiter that passes over the same area twice a day with detailed observations of fires from a distance of 800 km, GOES is a stationary satellite located above the equator, and observes the larger fires from a distance of 20,000 km. Field experiments, such as the "SCAR-B" experiment in Brazil conducted in 1995 by INPE, NASA and Universities of Sao Paulo, Washington and Wisconsin, were used to determine the ability of satellites to observe fires and the emitted pollution. They are the basis of a new system of satellites designed by NASA to observe fires and pollution, the Earth Observing System AM1 and PM1. NASA plans to use the information for four observations a day of the fires and the emitted smoke. The information can be used to determine the location of the fires, to distinguish between small and large fires and monitor their development. The satellites will measure the emitted smoke and with trajectory models can be used to predict the density and spread of the smoke.

Kaufman, Y.↗

Aerosol spectral optical depths - Jet fuel and forest fire smokes

The Ames autotracking airborne sun photometer was used to investigate the spectral depth between 380 and 1020 nm of smokes from a jet fuel pool fire and a forest fire in May and August 1988, respectively. Results show that the forest fire smoke exhibited a stronger wavelength dependence of optical depths than did the jet fuel fire smoke at optical depths less than unity. At optical depths greater than or equal to 1, both smokes showed neutral wavelength dependence, similar to that of an optically thin stratus deck. These results verify findings of earlier investigations and have implications both on the climatic impact of large-scale smokes and on the wavelength-dependent transmission of electromagnetic signals.

Pueschel, R. F.↗

Conceptual design study: Forest Fire Advanced System Technology (FFAST)

An integrated forest fire detection and mapping system that will be based upon technology available in the 1990s was defined. Uncertainties in emerging and advanced technologies related to the conceptual design were identified and recommended for inclusion as preferred system components. System component technologies identified for an end-to-end system include thermal infrared, linear array detectors, automatic georeferencing and signal processing, geosynchronous satellite communication links, and advanced data integration and display. Potential system configuration options were developed and examined for possible inclusion in the preferred system configuration. The preferred system configuration will provide increased performance and be cost effective over the system currently in use. Forest fire management user requirements and the system component emerging technologies were the basis for the system configuration design. A preferred system configuration was defined that warrants continued refinement and development, examined economic aspects of the current and preferred system, and provided preliminary cost estimates for follow-on system prototype development.

Nichols, J. D.↗

Atmospheric effects of a Canadian forest fire smoke plume

In 1982, a northern British Columbia forest fire created a massive smoke plume that could be detected for several days in satellite imagery. The radiative and dynamical impacts of this large forest fire smoke plume are investigated using interactive prognostic models of atmospheric circulation, aerosol microphysics and transport, and radiative heat transfer.

Westphal, Douglas L.↗

Satellite analysis of the severe 1987 forest fires in northern China and southeastern Siberia

Meteorological conditions, extremely conducive to fire development and spread in the spring of 1987, resulted in forest fires burning over extremely large areas in the boreal forest zone in northeastern China and the southeastern region of Siberia. The great China fire, one of the largest and most destructive forest fires in recent history, occurred during this period in the Heilongjiang Province of China. Satellite imagery is used to examine the development and areal distribution of 1987 forest fires in this region. Overall trace gas emissions to the atmosphere from these fires are determined using a satellite-derived estimate of area burned in combination with fuel consumption figures and carbon emission ratios for boreal forest fires.

Cahoon, Donald R, Jr.↗

Satellite Analysis of the Severe 1987 Forest Fires in Northern China and Southeastern Siberia

Meteorological conditions, extremely conducive to fire development and spread in the spring of 1987, resulted in forest fires burning over extremely large areas in the boreal forest zone in northeastern China and the southeastern region of Siberia. The great China fire, one of the largest and most destructive forest fires in recent history, occurred during this period in the Heilongjiang Province of China. Satellite imagery is used to examine the development and areal distribution of 1987 forest fires in this region. Overall trace gas emissions to the atmosphere from these fires are determined using a satellite-derived estimate of area burned in combination with fuel consumption figures and carbon emission ratios for boreal forest fires.

Cahoon, Donald R., Jr.↗

True Emission Factors for Forest Fires and the Role of Non-Fire NOx

True Emission Factors for Forest Fires and the Role of Non-Fire NOx Robert B. Chatfield and Meinrat Andreae The standard way to estimate biomass burning emissions factors from airborne, surface, or laboratory data is to relate the emitted pollutant concentration to the carbon burned, C(sub tot), and liberated to the air, mostly CO2. We approximate total emitted carbon C(sub tot) ~ (CO2 + CO). Emission ratios that are based on CO, describing burning effects, delta-parameter delta-CO, are often used to quantify fire emissions. These are not as useful as emission factors, for they often complicate analyses, since delta-CO delta-CO2 may vary by unto tenfold, and can have bias artifacts of similar magnitude. We present a methodology that estimates both emission factors and a reasonable description of background C(sub tot). High O3 values require a history of the balanced interaction of two pollutant types, nitrogen oxides (NOx) and a radical source, VOCs. However, high VOC NOx ratios seen in many plumes, especially from smoldering-dominated fires, make substantial O3 formation less likely. One particularly intense fire we analyzed, the notorious Rim Fire of 2013, near Yosemite, California. It produced notable quantities of free NOx and (both gas- and particle-phase) Cl species. Consequently, we also outline a quantitative way to assess the effects of anthropogenic or lightning NOx. We provide the example of California burning emissions using measurements of HCHO, NO, and the photolysis rate j(sub HCHO).

Chatfield, Robert B.↗

The Economical Microbolometer-Based Environmental Radiometer Satellite (EMBERSAT) Designed for Forest Fire Detection and Monitoring

Thermal infrared imagery from several satellite instruments, such as the NOAA AVHRR and the NASA MODIS, is presently used to detect and map forest fires. But while these radiometers can identify fires they are designed and optimized for cloud detection, providing relatively low spatial resolution and quickly saturating even for small fires. Efforts to detect and monitor forest fires from space would benefit from the development of single-sensor satellites designed specifically for this purpose. With the advent of uncooled thermal detectors, and thus the absence of aggressive cooling, the possibility of developing small satellites for the purpose of fire detection and monitoring becomes practical and cost-effective. Thus is the case with the Economical Microbolometer Based Environmental Radiometer Satellite (EMBERSat) program. The objective of this program is to develop a single, prototype satellite that will provide multiband thermal imagery with a spatial resolution of 250m and a dynamic range of 300-1000K. The thermal imaging payload has flight heritage in the Infrared Spectral Imaging Radiometer that flew aboard mission STS-85 and the spacecraft is a variant of the SimpleSat bus launched from the shuttle Columbia as part of STS-109. The EMBERSat program is a technology demonstration initiative with the eventual goal of providing high-resolution thermal imagery to both the scientific community and the public.

Lancaster, Redgie S.↗

The Economical Microbolometer-Based Environmental Radiometer Satellite (EMBERSat) Designed for Forest Fire Detection and Monitoring

Thermal infrared imagery from several satellite instruments, such as the NOAA AVHRR and the NASA MODIS, is presently used to detect and map forest fires. But while these radiometers can identify fires they are designed and optimized for cloud detection, providing relatively low spatial resolution and quickly saturating even for small fires. Efforts to detect and monitor forest fires from space would benefit from the development of single-sensor satellites designed specifically for this purpose. With the advent of uncooled thermal detectors, and thus the absence of aggressive cooling, the possibility of developing small satellites for the purpose of fire detection and monitoring becomes practical and cost-effective. Thus is the case with the Economical Microbolometer Based Environmental Radiometer Satellite (EMBERSat) program. The objective of this program is to develop a single, prototype satellite that will provide multiband thermal imagery with a spatial resolution of 250m and a dynamic range of 300-1000K. The thermal imaging payload has flight heritage in the Infrared Spectral Imaging Radiometer that flew aboard mission STS-85 and the spacecraft is a variant of the SimpleSat bus launched from the shuttle Columbia as part of STS-105. The EMBERSat program is a technology demonstration initiative with the eventual goal of providing high-resolution thermal imagery to both the scientific community and the public.

Lancaster, Redgie S.↗

Entrainment and Optical Properties of an Elevated Forest Fire Plume Transported into the Planetary Boundary Layer near Washington, D.C.

Smoke and pollutants from Canadian forest fires were transported over the northeastern United States in July 2002. Lidar observations at the NASA Goddard Space Flight Center show the smoke from these fires arriving in an elevated plume that was subsequently transported to the surface. Trajectory and three-dimensional model calculations confirm the origin of the smoke and show that it mixed to the surface after it was intercepted by the turbulent planetary boundary layer. Modeled smoke optical properties agreed well with aircraft and remote sensing observations provided coagulation of smoke particles was accounted for in the model. Our results have important implications for the long-range transport of pollutants and their subsequent entrainment to the surface, as well as the evolving optical properties of smoke from boreal forest fires.

Colarco, P. R.↗

Entrainment and Optical Properties of an Elevated Canadian Forest Fire Plume Transported into the Planetary Boundary Layer near Washington, D.C.

Smoke and pollutants from Canadian forest fires were transported over the northeastern United States in July 2002. Lidar observations at the NASA Goddard Space Flight Center show the smoke from these fires arriving in an elevated plume that was subsequently mixed to the surface. Trajectory and three-dimensional model calculations confirm the origin of the smoke and show that it mixed to the surface after it was intercepted by the turbulent planetary boundary layer. Modeled smoke optical properties agreed well with aircraft and remote sensing observations provided coagulation of smoke particles was accounted for in the model. Our results have important implications for the long-range transport of pollutants and their subsequent entrainment to the surface, as well as the evolving optical properties of smoke from boreal forest fires.

Colarco, P. R.↗

A feasibility study: Forest Fire Advanced System Technology (FFAST)

The National Aeronautics and Space Administration/Jet Propulsion Laboratory and the United States Department of Agriculture Forest Service completed a feasibility study that examined the potential uses of advanced technology in forest fires mapping and detection. The current and future (1990's) information needs in forest fire management were determined through interviews. Analysis shows that integrated information gathering and processing is needed. The emerging technologies that were surveyed and identified as possible candidates for use in an end to end system include ""push broom'' sensor arrays, automatic georeferencing, satellite communication links, near real or real time image processing, and data integration. Matching the user requirements and the technologies yielded a ""strawman'' system configuration. The feasibility study recommends and outlines the implementation of the next phase for this project, a two year, conceptual design phase to define a system that warrants continued development.

Mcleod, R. G.↗

Fighting Forest Fires

Firefly is an airborne system for imaging forest fires. It uses satellite-based navigation for greater positioning accuracy and offers timeliness in fire location data delivery with on board data processing and a direct aircraft-to-fire camp communications link. Developed by Jet Propulsion Laboratory and the USFS, it has an infrared line scanner to identify fire boundaries and an infrared sensor system that can penetrate smoke to image the ground. Firefly is an outgrowth of a previous collaboration that produced FLAME, an airborne fire mapping instrument. Further refinements are anticipated by NASA and the United States Forest Service (USFS).

Source record↗

Airborne forest fire research

The research relating to airborne fire fighting systems is reviewed to provide NASA/Langley Research Center with current information on the use of aircraft in forest fire operations, and to identify research requirements for future operations. A literature survey, interview of forest fire service personnel, analysis and synthesis of data from research reports and independent conclusions, and recommendations for future NASA-LRC programs are included.

Mattingly, G. S.↗

Simulations of microphysical, radiative, and dynamical processes in a continental-scale forest fire smoke plume

The impact of a large forest fire smoke plume on atmospheric processes is studied through a numerical model of meteorology, aerosols, and radiative transfer. The simulated smoke optical depths at 0.63-micron wavelength are in agreement with analyses of satellite data and show values as high as 1.8. The smoke has an albedo of 35 percent, or more than double the clear-sky value, and cools the surface by as much as 5 K. An imaginary refractive index, n sub im, of 0.01 yields results which closely match the observed cooling, single scattering albedo, and the Angstrom wavelength exponent. An n exp im of 0.1, typical of smoke from urban fires, produces 9 K cooling. Coagulation causes the geometric mean radius by number to increase from the initial value of 0.08 micron to a final value of 0.15 micron, while the specific extinction and absorption increase by 40 and 25 percent, respectively.

Westphal, Douglas L.↗

Saskatchewan Forest Fire Control Centre Surface Meteorological Data

The Saskatchewan Forest Fire Control Centre (SFFCC) provided surface meteorological data to BOREAS from its archive. This data set contains hourly surface meteorological data from 18 of the Meteorological stations located across Saskatchewan. Included in these data are parameters of date, time, temperature, relative humidity, wind direction, wind speed, and precipitation. Temporally, the data cover the period of May through September of 1994 and 1995. The data are provided in comma-delimited ASCII files, and are classified as AFM-Staff data. The data files are available on a CD-ROM (see document number 20010000884), or from the Oak Ridge National Laboratory (ORNL) Distributed Active Archive Center (DAAC).

Hall, Forrest G.↗

Forest Fire Observation

Conditions on the perimeter of a forest fire can be obtained by use of airborne remote sensing techniques demonstrated by Ames Research Center. An Ames U-2 high-altitude survey aircraft served as an aerial fire observation system. Equipped with two types of sensors, the U-2 produces real-time infrared images of fireground scenes. Information acquired by the U-2's scanners defines the fire boundary and aids fire management decisions by showing the size, shape and direction of burn and the locations of hot spots in the fire zone. U-2 sends sensor date in digital form to an antenna at Ames Research Center. There the data is computer processed into images which are overlaid on U.S. Geological Survey topographical maps of the fire area. Maps are then transmitted by telecopy machine directly to fire control center. Whole process takes less than 10 minutes and the U-2 can provide information for up to five hours. Ames antenna can pick up signals from the U-2 anywhere within a 300 mile radius from Ames.

Source record↗