Search NASA⌕ Search

SEARCH · Search NASA

Results for “Formed Core Sampler”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Formed Core Sampler Hydraulic Conductivity Testing

A full-scale formed core sampler was designed and functionally tested for use in the Saltstone Disposal Facility (SDF). Savannah River National Laboratory (SRNL) was requested to compare properties of the formed core samples and core drilled samples taken from adjacent areas in the full-scale sampler. While several physical properties were evaluated, the primary property of interest was hydraulic conductivity. Differences in hydraulic conductivity between the samples from the formed core sampler and those representing the bulk material were noted with respect to the initial handling and storage of the samples. Due to testing conditions, the site port samples were exposed to uncontrolled temperature and humidity conditions prior to testing whereas the formed core samples were kept in sealed containers with minimal exposure to an uncontrolled environment prior to testing. Based on the results of the testing, no significant differences in porosity or density were found between the formed core samples and those representing the bulk material in the test stand.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Collection, release, and detection of analytes with polymer composite sampling materials

A unique fiber core sampler composition, related systems, and techniques for designing, making, and using the same are described. The sampler is used to interface with existing field instrumentation, such as Ion Mobility Spectrometer (IMS) equipment. Desired sampler characteristics include its: stiffness/flexibility; thermal mass and conductivity; specific heat; trace substance collection/release dependability, sensitivity and repeatability; thickness; reusability; durability; stability for thermal cleaning; and the like. In one form the sampler has a glass fiber core with a thickness less than 0.3 millimeter that is coated with a polymer including one or more of: polymeric organofluorine, polyimide, polyamide, PolyBenzlmidazole (PBI), PolyDiMethylSiloxane (PDMS), sulfonated tetrafluoroethylene (PFSA) and Poly(2,6-diphenyl-p-phenylene Oxide) (PPPO). Multiple polymer coatings with the same or different polymer types may be included, core/substrate surface functionalization utilized, and/or the core/substrate may be at partially filled with thermally conductive particles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Collection, release, and detection of analytes with polymer composite sampling materials

A unique fiber core sampler composition, related systems, and techniques for designing, making, and using the same are described. The sampler is used to interface with existing field instrumentation, such as Ion Mobility Spectrometer (IMS) equipment. Desired sampler characteristics include its: stiffness/flexibility; thermal mass and conductivity; specific heat; trace substance collection/release dependability, sensitivity and repeatability; thickness; reusability; durability; stability for thermal cleaning; and the like. In one form the sampler has a glass fiber core with a thickness less than 0.3 millimeter that is coated with a polymer including one or more of: polymeric organofluorine, polyimide, polyamide, PolyBenzlmidazole (PBI), PolyDiMethylSiloxane (PDMS), sulfonated tetrafluoroethylene (PFSA) and Poly(2,6-diphenyl-p-phenylene Oxide) (PPPO). Multiple polymer coatings with the same or different polymer types may be included, core/substrate surface functionalization utilized, and/or the core/substrate may be at partially filled with thermally conductive particles.

36 MATERIALS SCIENCE↗

Collection, release, and detection of analytes with polymer composite sampling materials

A unique fiber core sampler composition, related systems, and techniques for designing, making, and using the same are described. The sampler is used to interface with existing field instrumentation, such as Ion Mobility Spectrometer (IMS) equipment. Desired sampler characteristics include its: stiffness/flexibility; thermal mass and conductivity; specific heat; trace substance collection/release dependability, sensitivity and repeatability; thickness; reusability; durability; stability for thermal cleaning; and the like. In one form the sampler has a glass fiber core with a thickness less than 0.3 millimeter that is coated with a polymer including one or more of: polymeric organofluorine, polyimide, polyamide, PolyBenzlmidazole (PBI), PolyDiMethylSiloxane (PDMS), sulfonated tetrafluoroethylene (PFSA) and Poly(2,6-diphenyl-p-phenylene Oxide) (PPPO). Multiple polymer coatings with the same or different polymer types may be included, core/substrate surface functionalization utilized, and/or the core/substrate may be at partially filled with thermally conductive particles.

Addleman, Raymond S.↗

The Viking magnetic properties experiment - Primary mission results

Three permanent magnet arrays were mounted on each Viking lander: a strong array fixed on a photometric reference test chart on top of the landers; and two arrays, one strong and one weak, incorporated into the backhoe of the surface sampler. Some or all of the magnetic particles detected could be highly magnetic unoxidized mineral grains (metallic Fe, magnetite, pyrrhotite) forming the core beneath a reddish coating of limonite or hematite; or grains composed of gamma-Fe2O3, with and without other iron oxides; or igneous rock (or mineral particles) which consist of an admixture of unweathered silicate material or minerals with a significant fraction of highly magnetic phase, again with a reddish coating; they could be also igneous rock or mineral particles, intrinsically nonmagnetic, but having a reddish coating containing gamma-Fe2O3; or clay mineral particles which contain and/or are coated with Fe2O3, of which a substantial fraction is in the gamma-Fe2O3 form.

Hargraves, R. B.↗

Miniature Low-Mass Drill Actuated by Flextensional Piezo Stack

Recent experiments with a flextensional piezoelectric actuator have led to the development of a sampler with a bit that is designed to produce and capture a full set of sample forms including volatiles, powdered cuttings, and core fragments. The flextensional piezoelectric actuator is a part of a series of devices used to amplify the generated strain from piezoelectric actuators. Other examples include stacks, bimorphs, benders, and cantilevers. These devices combine geometric and resonance amplifications to produce large stroke at high power density. The operation of this sampler/drill was demonstrated using a 3x2x1-cm actuator weighing 12 g using power of about 10-W and a preload of about 10 N. A limestone block was drilled to a depth of about 1 cm in five minutes to produce powdered cuttings. It is generally hard to collect volatiles from random surface profiles found in rocks and sediment, powdered cuttings, and core fragments. Toward the end of collecting volatiles, the actuator and the bit are covered with bellows-shaped shrouds to prevent fines and other debris from reaching the analyzer. A tube with a miniature bellows (to provide flexibility) is connected to the bit and directs the flow of the volatiles to the analyzer. Another modality was conceived where the hose is connected to the bellows wall directly to allow the capture of volatiles generated both inside and outside the bit. A wide variety of commercial bellows used in the vacuum and microwave industries can be used to design the volatiles capture mechanism. The piezoelectric drilling mechanism can potentially be operated in a broad temperature range from about-200 to less than 450 C. The actuators used here are similar to the actuators that are currently baselined to fly as part of the inlet funnel shaking mechanism design of MSL (Mars Science Laboratory). The space qualification of these parts gives this drill a higher potential for inclusion in a future mission, especially when considering its characteristics of low mass, small size, low power, and low axial loads for sampling.

Sherrit, Stewart↗

Drilling, Coring and Sampling Using Piezoelectric Actuated Mechanisms: From the USDC to a Piezo-Rotary-Hammer Drill

NASA exploration missions are increasingly including sampling tasks but with the growth in engineering experience (particularly, Phoenix Scout and MSL) it is now very much recognized that planetary drilling poses many challenges. The difficulties grow significantly with the hardness of sampled material, the depth of drilling and the harshness of the environmental conditions. To address the requirements for samplers that could be operated at the conditions of the various bodies in the solar system, a number of piezoelectric actuated drills and corers were developed by the Advanced Technologies Group of JPL. The basic configuration that was conceived in 1998 is known as the Ultrasonic/Sonic Driller/Corer (USDC), and it operates as a percussive mechanism. This drill requires as low preload as 10N (important for operation at low gravity) allowing to operate with as low-mass device as 400g, use an average power as low as 2- 3W and drill rocks as hard as basalt. A key feature of this drilling mechanism is the use of a free-mass to convert the ultrasonic vibrations generated by piezoelectric stack to sonic impacts on the bit. Using the versatile capabilities f the USDC led to the development of many configurations and device sizes. Significant improvement of the penetration rate was achieved by augmenting the hammering action by rotation and use of a fluted bit to remove cuttings. To reach meters deep in ice a wireline drill was developed called the Ultrasonic/Sonic Gopher and it was demonstrated in 2005 to penetrate about 2-m deep at Antarctica. Jointly with Honeybee Robotics, this mechanism is currently being modified to incorporate rotation and inchworm operation forming Auto-Gopher to reach meters deep in rocks. To take advantage of the ability of piezoelectric actuators to operate over a wide temperatures range, piezoelectric actuated drills were developed and demonstrated to operate at as cold as -200oC and as hot as 500oC. In this paper, the developed mechanisms will be reviewed and discussed including the configurations, capabilities, and challenges.

ultrasonic/Sonic Driller/ Corer (USDC)↗

Does Collection Time Bias the Ecology of Cleanroom Air Samples?

Microbial monitoring of astromaterials collections has taken on increased importance with the return of biologically sensitive samples from the asteroids Ryugu and Bennu and the initiation of the Mars Sample Return Program. Terrestrial bacteria and fungi can alter the mineralogy and organic composition of our collections causing irreversible contamination of pristine samples and increasing the risk of false positives for life detection measurements. NASA has conducted routine microbial monitoring of its existing collections since 20181. Initial monitoring focused on surface samples collected with foam swabs. Although, airborne microbiology is often decoupled from surface microbiology in the built environment2 culture-based air sampling techniques like impactors were not compliant with existing contamination control requirements. Bringing organic rich media, gelatin or liquids into curation cleanrooms presents an unacceptable risk to pristine samples. In 2022 NASA purchased a materials complaint air sampler and began collecting air samples from the cleanrooms in addition to surface samples3. The new instrument uses an electret filter to collect samples that are suitable for cultivating organisms or for direct DNA sequencing. Preliminary DNA sequencing results appeared to indicate that longer sampling times biased the microbial community in favor of hearty, spore-forming bacteria3. We present the results of a study comparing overnight sampling (17 hours) to short (1 hour) sampling of unoccupied curation cleanrooms. The results will help us optimize our monitoring protocols and develop a more detailed inventory of the ecology of astromaterials curation cleanrooms. Methods: We analyzed 72 paired air samples from six different cleanrooms including the meteorite processing lab (ISO 7 equivalent, 16 samples), the lunar lab (ISO 6 equivalent, 10 samples), the stardust lab (ISO 5 equivalent 14 samples), the OSIRIS-REx lab (ISO 5 equivalent, 12 samples), the Hayabusa2 lab (ISO 5 equivalent, 14 samples), and the Genesis lab (ISO 4 equivalent, 6 samples). All the samples were collected with an InnovaPrep Bobcat air sampler operating at a sampling rate of 200 L/min. The sampler operates for 5 minutes out of every 20 minute period. Half of the samples were collected by filtering 3,000L (15 min. of active sampling) of air across an electret filter for one hour. The rest of the samples were collected by filtering approximately 51,000 L air across the filter overnight (~17 hours, 255 min. of active sampling). Cells were eluted from the filter using 6-7 ml of pressurized 0.15% tween 20 in PBS (phosphate buffered saline). This liquid was used to cultivate bacteria according to previously published methods1,4,5 and for DNA extraction and next generation sequencing. DNA was extracted with a Qiagen MagAttract PowerMicrobiome kit6. To identify bacteria and archaea, the 16S rRNA gene was amplified using Earth Microbiome primers for the V4 region 7. The amplified DNA was sequenced on an Illumina MiSeq using a V3 reagent kit. The resulting sequences were processed using DADA2 and QIIME2 as implemented on the EDGE bioinformatics platform8–10. Results: Only two of the 72 samples had no amplifiable DNA. Amplified DNA concentrations ranged from 2.67 – 0.272 ng/µl. The median concentration of amplified DNA for the 1 hour samples was 0.770 ± 0.368 ng/µl. The median concentration of amplified DNA for the overnight samples was 0.877 ± 0.434 ng/µl. On average the overnight samples had slightly more sequences (58,960 vs. 59,456) and ASV’s (amplicon sequence variants) (60 vs 64.5) than the one hour samples, but these differences are not statistically significant. The most abundant ASV in every sample mapped to the genus Cupravidus. ASV’s mapping to the genuses Bacillus, Schlegelella, Thermus, and Staphylococcus were also common. Discussion and Future Work: Alpha diversity statistics like Shannon Entropy and Faith Phylogenetic Diversity are used to describe the diversity of organisms in a single sample. If a longer sampling time was biasing the data, we would expect to see a change in these diversity statistics vs. sample time. However, we did not observe this in our data. The median Shannon entropy was slightly higher for the overnight samples (3.773 vs 3.611) as was the Faith Phylogenetic Diversity (4.042 vs 3.596), but both values were within a standard deviation of each other for the two sampling times (Fig. 1). It is unlikely, that the longer sampling time is introducing bias into our data. We do observe a significant decrease in diversity when comparing the air samples by lab. The Genesis lab (ISO 4 equivalent) has a lower median number of ASV’s (45.5) than the other labs (62). Median values for Shannon Entropy (3.717 vs. 3.430) and Faith Phylogenetic Diversity (3.796 vs. 3.548) are also lower for Genesis, but those values are with one standard deviation of each other for the different sampling times. This is consistent with previous culture-based results suggesting that the environment in cleanrooms tends to select for a core group of organisms capable of surviving under dry, low nutrient, conditions. The presence of the ASV’s mapping to Cupravidus and Thermus in our sequencing blanks and controls suggests that several of the most common organisms in our samples represent contaminants from the reagents used to perform the DNA extractions and sequencing. Further work is needed to identify these contaminants, remove them from our data and recalculate the diversity statistics. This is a systematic error. Therefore, we do not expect removing the sequencing contaminants to change our conclusions. Longer air sample collection times appear to result in slightly higher diversity and do not bias the results towards “hardy” bacteria like spore-formers. Based on these preliminary results we conclude that sampling at least 3,000 liters of air is sufficient to capture the microbial diversity of cleanrooms, and that air samples can also be collected overnight without negatively impacting diversity. These results allow us to be flexible when designing microbial monitoring plans so that they do not interfere with routine lab activity. References: 1. Regberg, A. B. et al. 49th Lunar and Planetary Science Conference (2018). 2. The United States Pharmacopeial Convention. USP General Chapter <1116> (2013). 3. Regberg, A. B., et al. 54th Lunar and Planetary Science Conference (2023). 4. Regberg, A. B. et al. 53rd Lunar and Planetary Science Conference ( 2022). 5. Davis, R. E.,et al. 50th Lunar and Planetary Science Conference (2019). 6. Qiagen. MagAttract® PowerMicrobiome® DNA/RNA EP Kit Handbook. (2018). 7. Walters, W. et al. mSystems 1, (2015). 8. Callahan, B. J. et al. Nat. Methods 13, 581–583 (2016). 9. Hall, M. & Beiko, R. G. Microbiome Analysis: Methods and Protocols113–129 (Springer, 2018). 10. Philipson, C. et al. Bio-Protoc. 7, e2622 (2017).

A. B. Regberg↗