Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fourier Transform Infrared (FTIR)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Fourier transform infrared (FTIR) fiber optic monitoring of composites during cure in an autoclave

Real-time in situ monitoring of the chemical states of epoxy resins was investigated during cure in an autoclave using infrared evanescent spectroscopy. Fiber evanescent sensors were developed which may be sandwiched between the plies of the prepreg sample. A short length of sapphire fiber was used as the sensor cell portion of the fiber probe. Heavy metal fluoride glass optical fiber cables were designed for connecting the FTIR spectrometer to the sensor fiber within the autoclave. The sapphire fibers have outstanding mechanical thermal properties which should permit their use as an embedded link in all thermoset composites. The system is capable of operation at a temperature of 250 C for periods up to 8 hours without major changes to the fiber transmission. A discussion of the selection of suitable sensor fibers, the construction of a fiber-optic interface, and the interpretation of in situ infrared spectra of the curing process is presented.

Druy, Mark A.↗

Characterization of the surfaces of platinum/tin oxide based catalysts by Fourier Transform Infrared Spectroscopy (FTIR)

A Pt/SnO2 catalyst has been developed at NASA Langley that is effective for the oxidation of CO at room temperature (1). A mechanism has been proposed to explain the effectiveness of this catalyst (2), but most of the species involved in this mechanism have not been observed under actual catalytic conditions. A number of these species are potentially detectable by Fourier Transform Infrared Spectroscopy (FTIR), e.g., HOSnO sub x, HO sub y PtO sub z, Pt-CO, and SnHCO3. Therefore a preliminary investigation was conducted to determine what might be learned about this particular catalyst by transmission FTIR. The main advantage of FTIR for this work is that the catalyst can be examined under conditions similar to the actual catalytic conditions. This can be of critical importance since some surface species may exist only when the reaction gases are present. Another advantage of the infrared approach is that since vibrations are probed, subtle chemical details may be obtained. The main disadvantage of this approach is that FTIR is not nearly as sensitive as the Ultra High Vacuum (UHV) surface analytical techniques such as Auger, Electron Spectroscopy for Chemical Analysis (ESCA), Electron Energy Loss Spectroscopy (EELS), etc. Another problem is that the assignment of the observed infrared bands may be difficult.

Keiser, Joseph T.↗

Dataset for Cruz-O'Byrne et al (2026): "Divergent biogeochemical responses in upland coastal forest soils to repeated flooding and shifts in water chemistry"

Hydrologic disturbances from accelerated sea-level rise and the increasing frequency and intensity of storms and tidal flooding are altering biogeochemical processes in upland coastal forests, transforming these ecosystems into wetlands. However, the initial effects of flooding on belowground biogeochemistry and the mechanisms driving greenhouse gas dynamics and soil organic matter stability during the early stages of this transition remain poorly understood. This dataset presents the results of a mesocosm experiment conducted in a controlled, highly instrumented laboratory environment, in which freshwater and brackish water pulses were applied to intact soil monoliths from a temperate upland coastal forest to examine how floodwater chemistry influences soil biogeochemistry and organo-mineral interactions. All data files are plain-text CSV (comma-separated value), and no special software is required to read them. Details about the content of each file are available in the document “Dataset_readme”. The dataset consists of the following data: • rcruzobyrne_moisture: Soil volumetric water content (VWC) • rcruzobyrne_GHG: Headspace greenhouse gas (GHG) concentration and fluxes • rcruzobyrne_methane_isotopes: Headspace methane isotope signature • rcruzobyrne_porewater: Porewater chemistry • rcruzobyrne_CDOM: Porewater colored dissolved organic matter (CDOM) • rcruzobyrne_FTIR: Soil Fourier-transform infrared (FTIR) spectroscopy Details of the experimental setup, data collection, and data analysis are provided in the manuscript by Cruz-O’Byrne et al (2026) Divergent biogeochemical responses in upland coastal forest soils to repeated flooding and shifts in water chemistry. Biogeochemistry. https://doi.org/10.1007/s10533-026-01340-0

EARTH SCIENCE > ATMOSPHERE > GREENHOUSE GAS↗

Surface inspection using FTIR spectroscopy

The use of reflectance Fourier transform infrared (FTIR) spectroscopy as a tool for surface inspection is described. Laboratory instruments and portable instruments can support remote sensing probes that can map chemical contaminants on surfaces with detection limits under the best of conditions in the sub-nanometer range, i.e.. near absolute cleanliness, excellent performance in the sub-micrometer range, and useful performance for films tens of microns thick. Examples of discovering and quantifying contamination such as mineral oils and greases, vegetable oils, and silicone oils on aluminum foil, galvanized sheet steel, smooth aluminum tubing, and sandblasted 7075 aluminum alloy and D6AC steel. The ability to map in time and space the distribution of oil stains on metals is demonstrated. Techniques associated with quantitatively applying oils to metals, subsequently verifying the application, and non-linear relationships between reflectance and the quantity oil are described.

Powell, G. L.↗

Composition and persistence of soil organic matter along eroding and depositional transects in buried vs. modern soil layers: A case of the Brady paleosol at Wauneta, Nebraska

Paleosols form when soils are buried through deposition by aeolian, colluvial, alluvial or other processes. Burial of former topsoil isolates soil organic matter (SOM) from surface conditions, allowing carbon to accumulate and potentially remain stable for millennia. In this study, SOM composition, distribution, and persistence were analyzed in the Brady Soil of Nebraska, USA to compare SOM spatial variability in modern and buried soils, as well as the impact of erosional exposure on SOM stability. The Brady Soil, formed as a surface soil during the Pleistocene-Holocene transition and now a paleosol buried up to 6 m deep (or more) by loess deposition during the Holocene, was sampled along burial (up to 5.8 m depth) and erosional (up to 1.8 m depth) transects to compare SOM dynamics in different geomorphic settings. Fourier Transform Infrared Spectroscopy (FTIR) and Fourier Transform ion cyclotron resonance mass spectrometry (FTICR-MS) were used to analyze SOM composition, while δ 13 C isotope analyses identified SOM sources and radiocarbon values were used to estimate turnover rates. Results confirmed a vegetation shift from C3 to C4 plants after Brady Soil formation, reflecting warming climatic conditions. Increasing SOM age and decreasing δ 13 C and δ 15 N values with depth indicated slowing of decomposition rate in buried soils. Higher pH in the Brady Soil suggested greater base cation content, supporting SOM stabilization through organo-mineral associations and aggregate formation. However, exposure of the Brady Soil due to surface erosion caused faster SOM turnover. This result suggested susceptibility of buried SOM to losses via decomposition upon erosional exposure, possibly accelerated by priming in response to modern SOM inputs. These findings highlight the potential loss of carbon stocks in buried soils under future climate change, as shifts in soil physicochemical properties may destabilize long-preserved SOM.

Environmental sciences↗

FTIR Spectroscopic Characterization Of II-VI Semiconductors

Combination of commercial Fourier-transform infrared (FTIR) spectrometer with computer and special-purpose software constitutes highly automated facility for acquisition and processing of infrared transmission or reflection spectral image data. Intended principally to acquire transmission spectra of some compounds of elements in groups II and VI of periodic table. System used to characterize specimens of II/VI alloy semiconductors grown by directional solidification and quenching. Transmission-edge maps helpful in studies of flows, gradients of temperature, and coefficients of diffusion in solidifying melts. Data acquired by system include optical characteristics, and they both verify and complement data obtained by such other techniques as measurements of density and x-ray-dispersion analysis.

Perry, G. L. E.↗

FTIR Spectroscopy of HNO3 and NO2 Relevant to Stratospheric Wake Analysis

The Fourier Transform Infrared (FTIR) technique has been employed to measure absolute concentrations of nitric acid (HNO3) and nitrogen dioxide (NO2) with 1/cm resolution and an absorption pathlength of 4 m under quasi-static and flow conditions at atmospheric pressure and room temperature. Water features seen under quasi-static conditions diminished in intensity under flowing conditions. Nitric acid was observed in the 1660-1760/cm range, while nitrogen dioxide was detected both in the 1536-1660 and 1213-1400/cm ranges. Concentrations of nitrogen dioxide and nitric acid were determined to be 11.9 and 4.35 parts per million (ppm), respectively, with an uncertainty of 0.2 ppm. Experiments are underway with a 10 m cell to measure the absorption of nitric acid, water, sulfur dioxide, hydrochloric acid and ammonia on various materials such as glass, teflon, stainless steel and aluminum used for implementation of the flow system. Such materials will be used for the measurements of stratospheric trace gases by the Quartz Crystal Microbalance (QCM) and Surface Acoustic Wave (SAW) devices.

Abina, Rafiu A.↗

In situ analysis of CO during chemisorption and oxidation on graphite: Supported Pt by FTIR-microspectrometry

For chemisorption and oxidation on Pt/HOPG (highly-orientated pyrolytic) graphite, reflectance Fourier Transform Infrared (FTIR)-microspectrometry reveals a variable state and reactivity for CO. Even for model surface science systems, where surface heterogeneity is minimal, surface diffusion may be too slow relative to the reaction rate to avoid segregation of reactants into surface islands under steady-state conditions. Thus in CO oxidation on Pt (where the relevant surface diffusion coefficients are such that D sub O less than D sub CO) then reactant CO islands exists at the perimeters of which the surface reaction is thought to occur. Furthermore CO can chemisorb on metals in linear and bridge forms to extents which vary with precise faces predominantly exposed coverage, etc. Infrared has long been used to probe the nature of adsorbed CO on model film and heterogeneous surfaces, but it may now be that FTIR-microspectrometry will allow the state of this adsorbate and reactant to be investigated with a spatial resolution of 4.4 microns on model (and real) catalytic surfaces.

Self, Valerie A.↗

[Photodissociation of Acetylene and Acetone using Step-Scan Time-Resolved FTIR Emission Spectroscopy]

The photodissociation of acetylene and acetone was investigated as a function of added quenching gas pressures using step-scan time-resolved FTIR emission spectroscopy. Its main components consist of Bruker IFS88, step-scan Fourier Transform Infrared (FTIR) spectrometer coupled to a flow cell equipped with Welsh collection optics. Vibrationally excited C2H radicals were produced from the photodissociation of acetylene in the unfocused experiments. The infrared (IR) emission from these excited C2H radicals was investigated as a function of added argon pressure. Argon quenching rate constants for all C2H emission bands are of the order of 10(exp -13)cc/molecule.sec. Quenching of these radicals by acetylene is efficient, with a rate constant in the range of 10(exp -11) cc/molecule.sec. The relative intensity of the different C2H emission bands did not change with the increasing argon or acetylene pressure. However, the overall IR emission intensity decreased, for example, by more than 50% when the argon partial pressure was raised from 0.2 to 2 Torr at fixed precursor pressure of 160mTorr. These observations provide evidence for the formation of a metastable C2H2 species, which are collisionally quenched by argon or acetylene. Problems encountered in the course of the experimental work are also described.

McLaren, Ian A.↗

Highly automated optical characterization with FTIR spectrometry

The procedure for evaluating the characteristics of II-VI semiconducting infrared sensor materials with a Fourier Transform Infrared (FTIR) spectrometer system will be discussed. While the method of mapping optical characteristics with a spectrometer has been employed previously, this system is highly automated compared to other systems where the optical transmission data are obtained using a FTIR system with a small stationary aperture in the optical path and moving the specimen behind the aperture. The hardware and software, including an algorithm developed for extracting cut-on wavelengths of spectra, as well as several example results, are described to illustrate the advanced level of the system. Additionally, data from transverse slices and longitudinal wafers of the aforementioned semiconductors will be used to show the accuracy of the system in predicting trends in materials such as shapes of growth interfaces and compositional uniformity.

Perry, G. L. E.↗

Spaceborne Hybrid-FPGA System for Processing FTIR Data

Progress has been made in a continuing effort to develop a spaceborne computer system for processing readout data from a Fourier-transform infrared (FTIR) spectrometer to reduce the volume of data transmitted to Earth. The approach followed in this effort, oriented toward reducing design time and reducing the size and weight of the spectrometer electronics, has been to exploit the versatility of recently developed hybrid field-programmable gate arrays (FPGAs) to run diverse software on embedded processors while also taking advantage of the reconfigurable hardware resources of the FPGAs.

Bekker, Dmitriy↗

Absolute band intensities in the nu19/nu23 (530 cm(-1)) and nu7 (777 cm(-1)) bands of acetone ((CH3)2CO) from 232 to 295 K

Absolute band intensities of acetone ((CH3)2CO) in the nu19/nu23 and nu7 band systems near 530 and 777 cm(-1), respectively, were measured at temperatures of 232, 262 and 295 K, using a Fourier transform infrared (FTIR) spectrometer. No evident temperature dependence for the band intensities was observed. The dipole moments and the fundamental band intensities were derived in the harmonic oscillator approximation. The results are useful for the spectroscopic retrieval of acetone concentrations in the upper atmosphere.

Acetone/chemistry↗

Solar FTIR Measurements of NOx Vertical Distributions – Part 2: Experiment-Based Scaling Factors Describing the Daytime Variation in Stratospheric NOx

Long-term experimental stratospheric NO2 and NO partial columns measured by means of solar Fourier-transform infrared (FTIR) spectrometry at Zugspitze (47.42° N, 10.98° E; 2964 m a.s.l.), Germany, were used to create a set of experiment-based monthly scaling factors (SFexp). The underlying data set is published in a companion paper (Nürnberg et al., 2024) and comprises over 25 years of measurements depicting the daytime variability of stratospheric NO2 and NO partial columns with respect to local solar time (LST). In accordance with simulation-based scaling factors recently published by Strode et al. (2022), we created SFexp normalized to SZA =72° for NO2 and NO for every month of the year as a function of solar zenith angle (SZA). Apart from a boundary value problem at minimum SZA values originating from averaging over different times of the month, the obtained scaling factors SFexp(NO2) and SFexp(NO) as a function of SZA represent the daytime behavior already shown in model simulations and experiments in the literature very well. This shows a well-pronounced increase in the NO2 and NO stratospheric partial column with the time of the day and a flattening of this increase after noon. In addition to the discussion of SFexp, we validate the simulation-based scaling factors SFsim(NO2) (Strode et al., 2022) and present simulation-based scaling factors for NO SFsim(NO). The simulation-based scaling factors show excellent agreement with the experiment-based ones; i.e., for NO2 and NO the mean value of the modulus between the experiment and simulation over all SZAs and months is only 0.02 %. We show that recently used model simulations can describe the real behavior of nitrogen oxide (NOx) variability in the stratosphere very well. Furthermore, we conclude that ground-based FTIR measurements can be used for validation of the output of photochemistry models and for creating experiment-based data sets describing the daytime stratospheric NOx variability as a function of SZA. This is a contribution to improved satellite validation and a better understanding of stratospheric photochemistry.

FTIR, nitrogen oxides, diurnal variability↗

Novel laser gain and time-resolved FTIR studies of photochemistry

Several techniques are discussed which can be used to explore laboratory photochemical processes and kinetics relevant to planetary atmospheres; these include time-resolved laser gain-versus-absorption spectroscopy and time-resolved Fourier transform infrared (FTIR) emission studies. The laser gain-versus-absorption method employed tunable diode and F-center lasers to determine the yields of excited photofragments and their kinetics. The time-resolved FTIR technique synchronizes the sweep of a commercial FTIR with a pulsed source of light to obtain emission spectra of novel transient species in the infrared. These methods are presently being employed to investigate molecular photodissociation, the yields of excited states of fragments, their subsequent reaction kinetics, Doppler velocity distributions, and velocity-changing collisions of translationally fast atoms. Such techniques may be employed in future investigations of planetary atmospheres, for example to study polycyclic aromatic hydrocarbons related to cometary emissions, to analyze acetylene decomposition products and reactions, and to determine spectral features in the near infrared and infrared wavelength regions for planetary molecules and clusters.

Leone, Stephen R.↗

FTIR-spectrometer-determined absorption coefficients of seven hydrazine fuel gases - Implications for laser remote sensing

The absorption spectra of three hydrazines and four of their air-oxidation products were measured in the 9-12-micron spectral region with a Fourier transform infrared (FTIR) spectrometer with a 0.05-kayser resolution to determine absorption coefficients at CO2 and tunable diode laser wavelengths. The measurements agreed well with published CO2 laser determinations for many of the absorption coefficients, except where the published values are thought to be in error. The coefficients were then used to estimate the sensitivity for remote detection of these gases using CO2 and tunable diode lasers in long-path differential absorption measurements.

Molina, L. T.↗

FTIR Monitoring Of Curing Of Composites

Infrared-sensing optical fiber system developed to monitor principal infrared absorption bands resulting from vibrations of atoms and molecules as chemical bonds form when resin cured. System monitors resin chemistry more directly. Used to obtain Fourier transform infrared (FTIR) spectrum from graphite fiber/polyimide matrix resin prepreg. Embedded fiber optic FTIR sensor used to indicate state of cure of thermosetting composite material. Developed primarily to improve quality of advanced composites, many additional potential applications exist because principal of operation applicable to all organic materials and most inorganic gases. Includes monitoring integrities of composite materials in service, remote sensing of hazardous materials, and examination of processes in industrial reactors and furnaces.

Druy, Mark A.↗

FTIR studies of low temperature sulfuric acid aerosols

Sub-micrometer sized sulfuric acid H2SO4 particles were generated using a constant output atomizer source. The particles were then exposed to water vapor before being injected into a low temperature cell. Multipass transmission Fourier Transformation Infrared (FTIR) spectroscopy was used to determine the phase and composition of the aerosols as a function of time for periods of up to five hours. Binary H2SO4H2O aerosols with compositions from 35 to 95 wt % H2SO4 remained liquid for over 3 hours at room temperatures ranging from 189-240 K. These results suggest that it is very difficut to freeze SSAs via homogeneous nucleation. Attempts to form aerosols more dilute than 35 wt % H2SO4 resulted in ice formation.

Anthony, S. E.↗