Effects of forced and free convections on structural temperatures of Space Shuttle Orbiter during reentry flight

Structural performance and resizing (SPAR) finite-element thermal analysis computer program was used in the heat transfer analysis of the Space Shuttle Orbiter wing subjected to reentry aerodynamic heating. With sufficient external forced convective cooling near the end of the heating cycle, the calculated surface temperatures of the thermal protection system (TPS) agree favorably with the flight data for the entire flight profile. However, the effects of this external forced convective cooling on the structural temperatures were found to be negligible. Both free convection and forced convection elements were introduced to model the internal convection effect of the cool air entering the Shuttle interior. The introduction of the internal free convection effect decreased the calculated wing lower skin temperatures by 20 F at most, 1200 sec after touchdown. If the internal convection is treated as forced convection, the calculated wing lower skin temperatures after touchdown can be reduced to match the flight-measured data very closely. By reducing the TPS thicknesses to certain effective thickness to account for the TPs gap heating, the calculated wing lower skin temperatures prior to touchdown can be raised to agree with the flight data perfectly.

Ko, William L.↗

Interaction of free and forced convection in horizontal tubes in the transition regime.

Experimental investigation of some new aspects of the combined free and forced convection interacting in the transition regime of a horizontal tube under uniform heat flux conditions. The results obtained include indications that thermally induced secondary flows attenuate the fluctuations in low inlet turbulence flows, while they restabilize the flow as the inlet turbulence is increased.

Nagendra, H. R.↗

Combined forced and free convection in a curved duct

The purpose of this study is to investigate the flow and heat transfer characteristics of a combined forced and free convection flow in a curved duct. Solutions are obtained by solving the low Mach number model of the Navier-Stokes equation using a control volume method. The finite-volume method was developed with the use of a predictor-corrector numerical scheme and some new variations of the classical projection method. Solutions indicated that the existence of a buoyancy force has changed the entire flow structure inside a curved duct. Reversed flow at both inner and outer bend is observed. For moderate Reynolds number, the upstream section of the duct was significantly influenced by the free convection processes. In general, heat transfer is strong at the inner bend of the beginning of the heated section and at the outer bend on the last half of the heated section. The maximum velocity location is strongly influenced by the combined effects of buoyancy and centrifugal forces. A strong buoyancy force can reduce the strength of the secondary flow where it plays an important role in mixing.

Yam, Clement G.↗

Experimental Study of Combined Forced and Free Laminar Convection in a Vertical Tube

An apparatus was built to verify an analysis of combined forced and free convection in a vertical tube with uniform wall heat flux and to determine the limits of the analysis. The test section was electrically heated by resistance heating of the tube wall and was instrumented with thermocouples in such a way that detailed thermal entrance heat-transfer coefficients could be obtained for both upflow and downflow and any asymmetry in wall temperature could be detected. The experiments showed that fully developed heat-transfer results, predicted by a previous analysis, were confirmed over the range of Rayleigh numbers investigated. The concept of "locally fully developed" heat transfer was established. This concept involves the assumption that the fully developed heat-transfer analysis can be applied locally even though the Rayleigh number is varying along the tube because of physical-property variations with temperature. Thermal entrance region data were obtained for pure forced convection and for combined forced and free convection. The analysis of laminar pure forced convection in the thermal entrance region conducted by Siegel, Sparrow, and Hallman was experimentally confirmed. A transition to an eddy motion, indicated by a fluctuation in wall temperature was found in many of the upflow runs. A stability correlation was found. The fully developed Nusselt numbers in downflow were below those for pure forced convection but fell about 10 percent above the analytical curve. Quite large circumferential variations in wall temperature were observed in downflow as compaired with those encountered in upflow, and the fully developed Nussalt numbers reported are based on average wall temperatures determined by averaging the readings of two diametrically opposite wall thermocouples at each axial position. With larger heating rates in downflow the wall temperature distributions strongly suggested a cell flow near the bottom. At still larger heating rates the wall temperatures varied in a periodic way.

Hallman, Theodore M.↗

Details of Exact Low Prandtl Number Boundary-Layer Solutions for Forced and For Free Convection

A detailed report is given of exact (numerical) solutions of the laminar-boundary-layer equations for the Prandtl number range appropriate to liquid metals (0.003 to 0.03). Consideration is given to the following situations: (1) forced convection over a flat plate for the conditions of uniform wall temperature and uniform wall heat flux, and (2) free convection over an isothermal vertical plate. Tabulations of the new solutions are given in detail. Results are presented for the heat-transfer and shear-stress characteristics; temperature and velocity distributions are also shown. The heat-transfer results are correlated in terms of dimensionless parameters that vary only slightly over the entire liquid-metal range. Previous analytical and experimental work on low Prandtl number boundary layers is surveyed and compared with the new exact solutions.

Sparrow, E. M.↗

An analysis of laminar free-convection flow and heat transfer about a flat plate paralled to the direction of the generating body force

The free-convection flow and heat transfer (generated by a body force) about a flat plate parallel to the direction of the body force are formally analyzed and the type of flow is found to be dependent on the Grashof number alone. For large Grashof numbers (which are of interest in aeronautics), the flow is of the boundary-layer type and the problem is reduced in a formal manner, which is analogous to Prandtl's forced-flow boundary-layer theory, to the simultaneous solution of two ordinary differential equations subject to the proper boundary conditions. Velocity and temperature distributions for Prandtl numbers of 0.01, 0.72, 0.733, 1, 1, 10, 100, and 1000 are computed, and it is shown that velocities and Nusselt numbers of the order of magnitude of those encountered in forced-convection flows may be obtained in free-convection flows. The theoretical and experimental velocity and temperature distributions are in good agreement. A flow and a heat-transfer parameter, from which the important physical quantities such as shear stress and heat-transfer rate can be computed, are derived as functions of Prandtl number alone.

Ostrach, Simon↗

Natural convection with combined driving forces

The problem of free and natural convection with combined driving forces is considered in general and all possible configurations are identified. Dimensionless parameters are discussed in order to help categorize the various problems, and existing work is critically evaluated. Four distinct cases are considered for conventional convection and for the situation when the body force and the density gradient are parallel but opposed. Considerable emphasis is given to unstable convection in horizontal layers.

Ostrach, S.↗

Experimental and Numerical Characterization of a Cylindrical Blackbody Cavity

During hypersonic flight, high temperatures and high heat fluxes are generated on the surfaces of vehicles. The Flight Loads Laboratory (FLL) at Dryden Flight Research Center (DFRC) is equipped with a calibration furnace, capable of calibrating heat flux gages up to 1100kW per square meters, and temperature sensors up to 2600 C. One heating configuration of the calibration furnace is a cylindrical blackbody cavity. Throughout the blackbody there are temperature gradients due to various boundary conditions. These boundary conditions include resistance heating, radiant heat transfer, and conduction to water-cooled electrodes. Also, an inert gas is purged through the graphite blackbody to prevent it from oxidizing. Consequently, the various modes of heat transfer present during operation of the blackbody cavity must be well understood in order to produce accurate heat flux gage and temperature sensor calibrations for use in ground testing or flight testing of hypersonic vehicles. The first step towards understanding the heat transfer in the blackbody cavity was to perform experiments at 1100 C, with and without outer surface insulation, while taking detailed temperature measurements inside the blackbody cavity. Steady state thermal models of the blackbody cavity were then developed. These models included detailed thermal analysis using commercial thermal analysis software. Conduction, radiation, and convection were considered in the thermal models for two cases: one with the outside of the blackbody cavity insulated and the second without insulation. This paper describes the experimental and numerical efforts used to characterize the steady state operation of the blackbody cavity. It describes the analysis of the test measurements, the boundary conditions used in the numerical models, and how the models were calibrated to fit the experimental data. Effects of various uncertainties, such as material properties, and convection are discussed.Initial thermal models predicted temperatures in the deepest part of the blackbody cavity within 7 C of the measured value and produced trends comparable to the experimental data, throughout the models. Adjustment of the boundary conditions, which were included in the thermal models, produced good agreement with measured temperatures. Free and forced convection of the purge gas inside the blackbody was found to be insignificant.

Abdelmessih, Amanie N.↗

Thermal scale modeling of radiation-conduction-convection systems.

Investigation of thermal scale modeling applied to radiation-conduction-convection systems with particular emphasis on the spacecraft cabin atmosphere/cabin wall thermal interface. The 'modified material preservation,' 'temperature preservation,' 'scaling compromises,' and 'Nusselt number preservation' scale modeling techniques and their inherent limitations and problem areas are described. The compromised scaling techniques of mass flux preservation and heat transfer coefficient preservation show promise of giving adequate thermal similitude while preserving both gas and temperature in the scale model. The use of these compromised scaling techniques was experimentally demonstrated in tests of full scale and 1/4 scale models. Correlation of test results for free and forced convection under various test conditions shows the effectiveness of these scaling techniques. It is concluded that either mass flux or heat transfer coefficient preservation may result in adequate thermal similitude depending on the system to be modeled. Heat transfer coefficient preservation should give good thermal similitude for manned spacecraft scale modeling applications.

Shannon, R. L.↗

3-D thermal analysis using finite difference technique with finite element model for improved design of components of rocket engine turbomachines for Space Shuttle Main Engine SSME

Three-dimensional finite element models were generated and transferred into three-dimensional finite difference models to perform transient thermal analyses for the SSME high pressure fuel turbopump's first stage nozzles and rotor blades. STANCOOL was chosen to calculate the heat transfer characteristics (HTCs) around the airfoils, and endwall effects were included at the intersections of the airfoils and platforms for the steady-state boundary conditions. Free and forced convection due to rotation effects were also considered in hollow cores. Transient HTCs were calculated by taking ratios of the steady-state values based on the flow rates and fluid properties calculated at each time slice. Results are presented for both transient plots and three-dimensional color contour isotherm plots; they were also converted into universal files to be used for FEM stress analyses.

Sohn, Kiho D.↗

Convective heat transfer to low-temperature fluids

Research into forced and natural convection processes in low-temperature (cryogenic) fluids is reviewed with primary emphasis on forced convection. Boundaries of the near-critical region are defined, fluid properties near the critical state are discussed, and heat-transfer processes around the critical point are described. The thermodynamics of the critical point is analyzed together with transport properties of a near-critical fluid, and the quantum states of low-temperature molecular hydrogen (para and ortho) are discussed. Experimental work on heat transfer in free, natural, and forced convection systems is briefly summarized. Graham's (1969) penetration model for near-critical fluids is outlined, near-critical heat transfer is discussed in relation to conventional geometric effects, and the effects of curvature on the properties of near-critical hydrogen are noted. Theoretical considerations in free and forced convection are examined.

Graham, R. W.↗

Photospheric Current Spikes and Their Possible Association with Flares - Results from an HMI Data Driven Model

A data driven, near photospheric magnetohydrodynamic model predicts spikes in the horizontal current density, and associated resistive heating rate per unit volume Q. The spikes appear as increases by orders of magnitude above background values in neutral line regions (NLRs) of active regions (ARs). The largest spikes typically occur a few hours to a few days prior to M or X flares. The spikes correspond to large vertical derivatives of the horizontal magnetic field. The model takes as input the photospheric magnetic field observed by the Helioseismic & Magnetic Imager (HMI) on the Solar Dynamics Observatory (SDO) satellite. This 2.5 D field is used to determine an analytic expression for a 3 D magnetic field, from which the current density, vector potential, and electric field are computed in every AR pixel for 14 ARs. The field is not assumed to be force-free. The spurious 6, 12, and 24 hour Doppler periods due to SDO orbital motion are filtered out of the time series of the HMI magnetic field for each pixel using a band pass filter. The subset of spikes analyzed at the pixel level are found to occur on HMI and granulation scales of 1 arcsec and 12 minutes. Spikes are found in ARs with and without M or X flares, and outside as well as inside NLRs, but the largest spikes are localized in the NLRs of ARs with M or X flares. The energy to drive the heating associated with the largest current spikes comes from bulk flow kinetic energy, not the electromagnetic field, and the current density is highly non-force free. The results suggest that, in combination with the model, HMI is revealing strong, convection driven, non-force free heating events on granulation scales, and that it is plausible these events are correlated with subsequent M or X flares. More and longer time series need to be analyzed to determine if such a correlation exists. Above an AR dependent threshold value of Q, the number of events N(Q) with heating rates greater than or equal to Q obeys a scale invariant power law distribution for each AR given by N(Q) varies Q(sup -s), where 0.40 less than or equal to S less than or equal to 0.53, with a mean and standard deviation across the 14 ARs of 0.47 and 0.045, showing there is little variation of S from one AR to another. These properties of N(Q) are in close agreement with those of the distribution N(E) for the total energy E of solar flares, determined from observations to be N(E) = constant x E(sup -alpha). From observations of nanoflares in the 0.7 to 4 MK range, and from observations of flares in hard X-rays, it is found that 0.51 less than or equal to alpha less than or equal to 0.57, and 0.4 less than or equal to alpha less than or equal to 0.6, respectively (Crosby et al. 1993, Sol. Phys., 143, 275; Aschwanden & Parnell 2002, ApJ, 572, 1048). Observations also show that, as is found here for the exponent S, there is little variation of alpha with AR (Wheatland 2000, ApJ, 532, 1209), indicating N(E) and N(Q) are largely independent of individual properties of ARs such as area, total magnetic flux, and distribution of current density (i.e. non-potentiality). Therefore the power law scaling of the photospheric heating rate Q computed here on granulation scales is essentially identical to that found for coronal observations of flare energies on scales 1-2 orders of magnitude larger. This suggests the physical mechanisms that cause Q and coronal flares are closely related. It seems likely that Q is the signature of a magnetic reconnection process in an energy range and volume orders of magnitude smaller than those of flares. In this context, at least the larger spikes in Q might be signatures of UV photospheric or lower chromospheric bombs in which plasma is heated to temperatures approximately 10(exp -5) K (Peter et al. 2014, Science 346, 1255726; Judge 2015, ApJ, 808, 116). In addition, lattice based avalanche simulations of flare energy release predict 0.4 less than or equal to alpha less than or equal to 0.5, while analytic, fractal-diffusive self-organized criticality models predict 0.4 less than or equal to alpha less than or equal to 0.67, in excellent agreement with observations, and the results presented here (Aschwanden & Parnell 2002, ApJ, 572, 1048; Aschwanden 2012, A&A, 539, A2; Aschwanden 2013, in "Self Organized Criticality Systems"; Aschwanden et al. 2016, SSR, 198, 47).

Goodman, Michael↗

Hot stage and sample cell design for the solidification of transparent materials with and without forced convection

A temperature gradient stage design for optical microscopy is described. Exceptional thermal stability is the major feature. The stage is used to study crystal growth phenomena occurring at the solid-liquid interface. The apparatus is designed to use transparent organic solutions as models for the study of metal-like solidification. The stage provides a controlled thermal environment for unidirectional solidification of low melting temperature materials. Freezing rate is regulated by mechanically sliding in the stage a thin glass cell containing the materials being studied. Two cell assemblies are described. One type is used for convection-free and the other for controlled forced convection studies of the solidification interface.

Kaukler, W. F.↗

Modeling heat exchange characteristics of long term space operations: Role of skin wettedness and exercise

The problems of heat exchange during rest and exercise during long term space operations are covered in this report. Particular attention is given to the modeling and description of the consequences of requirement to exercise in a zero-g atmosphere during Space Shuttle flights, especially long term ones. In space environments, there exists no free convection therefore only forced convection occurring by movement, such as pedalling on a cycle ergometer, augments required heat dissipation necessary to regulate body temperature. The requirement to exercise at discrete periods of the day is good practice in order to resist the deleterious consequences of zero-gravity problems and improve distribution of body fluids. However, during exercise (ca. 180 to 250W), in zero-g environments, the mass of eccrine sweating rests as sheets on the skin surface and the sweat cannot evaporate readily. The use of exercise suits with fabrics that have hydrophobic or outwicking properties somewhat distributes the mass of sweat to a larger surface from which to evaporate. However, with no free convection, increased skin wettedness throughout the body surface induces increasing thermal discomfort, particularly during continuous exercise. This report presents several alternatives to aid in this problem: use of intermittent exercise, methods to quantify local skin wettedness, and introduction of a new effective temperature that integrates thermal stress and heat exchange avenues in a zero-g atmosphere.

Gonzalez, Richard R.↗