Search NASA⌕ Search

SEARCH · Search NASA

Results for “Frequency measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Absolute frequency measurements for emission transitions of molecular iodine in the range of 1053 – 1068 nm

Results of high-precision frequency measurements are presented for certain components of the {sup 127}I{sub 2} hyperfine structure, which correspond to emission transitions of the B – X band in the range of 1053 – 1068 nm. The frequencies are measured by using a femtosecond optical frequency synthesiser based on a Ti:sapphire laser. The hyperfine structure is resolved by the method of three-level laser spectroscopy. The frequency-doubled cw Nd : YAG laser is used as an excitation radiation source, and the probe radiation in the range of 1050 – 1070 nm is generated by an external-cavity diode laser. The frequencies of both lasers are simultaneously locked to those of two adjacent hyperfine structure components of iodine lines, which have a common upper level. Correspondingly, the frequency of the Nd : YAG laser is locked to the frequency of the absorption transition component, and the diode laser frequency – to the frequency of the emission transition component. The radiation frequency of the diode laser ‘locked’ in this way is measured. Frequencies of 18 hyperfine structure components for six emission lines corresponding to the bands (32 – 54) and (32 – 53) are measured. The relative uncertainty of the measurement is 8 × 10{sup –10}. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Precise frequency measurements of {sup 127}I{sub 2} lines in the wavelength region 750-780 nm

High precision frequency measurements of {sup 127}I{sub 2} hyperfine transitions in the wavelength range between 750 and 780 nm were performed employing an optical frequency comb. A Ti:sapphire laser is frequency stabilized to a hyperfine component of I{sub 2} using a Doppler-free frequency modulation technique, and an optical frequency comb is used to measure its frequency precisely. Improved absolute frequencies of 27 hyperfine transitions between 750 and 780 nm of the bands (0-12) and (0-13) of B {sup 3}{Pi}{sub 0{sub u{sup +}}}-X {sup 1}{Sigma}{sub g}{sup +} system of I{sub 2} are presented. The relative uncertainty of the measurement is a few times 10{sup -10}, limited by the frequency instability of the iodine-stabilized laser. The frequencies are compared to the predicted frequencies using the model description of [Eur. Phys. J. D 28, 199 (2004)], which yields differences larger than expected. An improved model is developed for the range from 755 to 815 nm for the prediction of lines with an error limit of the absolute frequency less than 0.2 MHz.

74 ATOMIC AND MOLECULAR PHYSICS↗

Absolute Frequency Measurement of the {sup 40}Ca{sup +} 4s {sup 2}S{sub 1/2}-3d {sup 2}D{sub 5/2} Clock Transition

We report on the first absolute transition frequency measurement at the 10{sup -15} level with a single, laser-cooled {sup 40}Ca{sup +} ion in a linear Paul trap. For this measurement, a frequency comb is referenced to the transportable Cs atomic fountain clock of LNE-SYRTE and is used to measure the {sup 40}Ca{sup +} 4s {sup 2}S{sub 1/2}-3d {sup 2}D{sub 5/2} electric-quadrupole transition frequency. After the correction of systematic shifts, the clock transition frequency {nu}{sub Ca{sup +}}=411 042 129 776 393.2(1.0) Hz is obtained, which corresponds to a fractional uncertainty within a factor of 3 of the Cs standard. In addition, we determine the Landeg factor of the 3d{sup 2}D{sub 5/2} level to be g{sub 5/2}=1.200 334 0(3)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fault-tolerant grid frequency measurement algorithm during transients

Many critical electric grid operations rely on accurate grid frequency measurements. Unfortunately, the measurement accuracy can be easily undermined by power system transient faults. During a power system transient fault, the power grid voltages and currents are usually highly distorted by high-frequency components. What is worse, the power grid signals could have discontinuity during some system transient faults such as phase angle jump, and the discontinuity could result in large measurement errors to state-of-the-art grid measurement algorithms. In this study, a fault-tolerant grid frequency measurement algorithm during transients is proposed. The new algorithm consists of two stages. The first stage is a transient detector, and it can detect the occurrence of system transient faults instantaneously. The second stage is the intelligent frequency estimator, and it will adapt its measurements according to the transient detector. The performance of the algorithm is evaluated under different steady-state and transient conditions. Both dependability and security of the fault-tolerant algorithm are assessed by using PSCAD simulation data and IEEE Standard test data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Absolute frequency measurement for the emission transitions of molecular iodine in the 982 - 985 nm range

We report high-precision frequency measurements of the separate hyperfine structure (HFS) components of the emission B - X system transitions of {sup 127}I{sub 2} molecules in the 982 - 985 nm range. To resolve the HFS of the emission lines, advantage was taken of the method of three-level laser spectroscopy. The function of exciting radiation was fulfilled by the second harmonic of a cw Nd : YAG laser, and the probe radiation in the 968 - 998 nm range was generated by an external-cavity diode laser. The output Nd : YAG laser frequency was locked to an HFS component of the absorption transition and the probing laser radiation to the emission transition component. When both frequencies were locked to HFS components with a common upper level, the output diode laser frequency was precisely equal to the emission transition frequency. The output frequency of the thus stabilised diode laser was measured with the help of a femtosecond optical frequency synthesiser based on a Ti : sapphire laser. We present the results of the absolute frequency measurements of 20 HFS components belonging to six vibrational - rotational transitions of the B - X system of iodine [R56(32 - 48)a1, P58(32 - 48)a1, P85(33 - 48)a1, R87(33 - 48a1, R88(33 - 48)a10] and all 15 components of the R86(33 - 48) line. The relative measurement uncertainty is equal to 7 Multiplication-Sign 10{sup -10} and is determined by the frequency instability of the diode laser radiation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Features of high-frequency measurements of the impedance of metal-insulator-semiconductor structures with an ultrathin oxide

The possibilities of using the data of high-frequency measurements of the impedance of metal-oxide-semiconductor structures with an ultrathin insulating layer for determining the parameters of the semiconductor and the tunneling characteristics of the insulator are considered. If the accuracy of the experiment makes it possible to record both the active and reactive impedance components, the thickness of the surface depletion layer, the resistance of the semiconductor base portion, the differential tunnel conductivity of the insulating layer, and the differential tunneling-stimulated current of the generation of electron-hole pairs are calculated using the values of the capacitance and conduction of the structure measured at two frequencies. In the case, where the values of the active component of the impedance is beyond the accuracy of measurements, analysis of the parameters is possible upon four-frequency organization of the experiment from the values of only the capacitances with an increased accuracy of their measurements. A test for the necessary accuracy of data of such an experiment is formulated. If the test fails, it is possible to determine only the capacitance of the surface depletion layer in the semiconductor and, in this case, it is sufficient to implement only the single-frequency experiment.

36 MATERIALS SCIENCE↗

Determination of defect density of state distribution of amorphous silicon solar cells by temperature derivative capacitance-frequency measurement

In this contribution, we demonstrate the application temperature dependent capacitance-frequency measurements (C-f) to n-i-p hydrogenated amorphous silicon (a-Si:H) solar cells that are forward-biased. By using a forward bias, the C-f measurement can detect the density of defect states in a particular energy range of the interface region. For this contribution, we have carried out this measurement method on n-i-p a-Si:H solar cells of which the intrinsic layer has been exposed to a H{sub 2}-plasma before p-type layer deposition. After this treatment, the open-circuit voltage and fill factor increased significantly, as well as the blue response of the solar cells as is concluded from external quantum efficiency. For single junction, n-i-p a-Si:H solar cells initial efficiency increased from 6.34% to 8.41%. This performance enhancement is believed to be mainly due to a reduction of the defect density in the i-p interface region after the H{sub 2}-plasma treatment. These results are confirmed by the C-f measurements. After H{sub 2}-plasma treatment, the defect density in the intrinsic layer near the i-p interface region is lower and peaks at an energy level deeper in the band gap. These C-f measurements therefore enable us to monitor changes in the defect density in the interface region as a result of a hydrogen plasma. The lower defect density at the i-p interface as detected by the C-f measurements is supported by dark current-voltage measurements, which indicate a lower carrier recombination rate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Optimal Load Control via Frequency Measurement and Neighborhood Area Communication

We propose a decentralized optimal load control scheme that provides contingency reserve in the presence of sudden generation drop. The scheme takes advantage of flexibility of frequency responsive loads and neighborhood area communication to solve an optimal load control problem that balances load and generation while minimizing end-use disutility of participating in load control. Local frequency measurements enable individual loads to estimate the total mismatch between load and generation. Neighborhood area communication helps mitigate effects of inconsistencies in the local estimates due to frequency measurement noise. Case studies show that the proposed scheme can balance load with generation and restore the frequency within seconds of time after a generation drop, even when the loads use a highly simplified power system model in their algorithms. We also investigate tradeoffs between the amount of communication and the performance of the proposed scheme through simulation-based experiments.

Zhao, CH↗

Precision frequency measurements with interferometric weak values

We demonstrate an experiment which utilizes a Sagnac interferometer to measure a change in optical frequency of 129 {+-} 7 kHz/{radical}(Hz) with only 2 mW of continuous-wave, single-mode input power. We describe the measurement of a weak value and show how even higher-frequency sensitivities may be obtained over a bandwidth of several nanometers. This technique has many possible applications, such as precision relative frequency measurements and laser locking without the use of atomic lines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High sensitivity resonance frequency measurements of individualmicro-cantilevers using fiber optical interferometry

We describe a setup for the resonance frequency measurement of individual microcantilevers. The setup displays both high spatial selectivity and sensitivity to specimen vibrations by utilizing a tapered uncoated fiber tip. The high sensitivity to specimen vibrations is achieved by the combination of optical Fabry-Perot interferometry and narrow band RF detection. Wave fronts reflected on the specimen and on the fiber tip end face interfere, thus no reference plane on the specimen is needed, as demonstrated with the example of freestanding silicon nitride micro-cantilevers. The resulting system is integrated in a DB-235 dual beam FIB system, thereby allowing the measurement of micro-cantilever responses during observation in SEM mode. The FIB was used to modify the optical fiber tip. At this point of our RF system development, the microcantilevers used to characterize the detector were not modified in situ.

36 MATERIALS SCIENCE↗

Frequency measurements and self-broadening of sub-Doppler transitions in the v1 + v3 band of C 2 H 2

Here, frequency comb-referenced measurements of sub-Doppler laser saturation dip absorption lines in the v1 + v3 band of acetylene near 1:5 μm are reported. These measurements include transitions involving higher rotational levels than previously frequency measured in this band. The accuracy of the measured frequencies is typically better than 10 kHz. Measurements of the observed sub-Doppler line widths as a function of pressure showed that the self pressure-broadening coefficients are about 3.5 times larger than those derived from conventional pressure broadening of unsaturated Doppler-limited spectra. This is attributed to the contribution of velocity-changing collisions to the total dephasing rate in the low pressure sub-Doppler measurements. At higher pressures, when the homogeneous broadening becomes comparable to the typical Doppler shift per elastic collision, the velocity changing collisions cease to contribute significantly to the incremental pressure broadening. Lastly, a time-dependent soft collision model is developed to illustrate the transition between low and high pressure regimes of sub-Doppler pressure-broadening.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

In Situ Frequency Measurement of Inidividual Nanostructures Using Fiber Optical Interferometry

In this paper we describe a setup for the resonance frequency measurement of nanocantilevers, which displays both high spatial selectivity and sensitivity to specimen vibrations by utilizing a tapered uncoated fiber tip. The spatial selectivity is determined by the tip geometry, the high sensitivity to vibrations stems from interference of wave fronts reflected on the specimen and on the fiber tip itself. No reference plane on the specimen is needed, as demonstrated with the example of a freestanding silicon nitride cantilever. The resulting system is integrated in the DB-235 dual beam FIB system, thus allowing the measurement of sample responses in-situ, during observation in SEM mode. By combining optical interferometry and narrow band RF amplification and detection, we demonstrate an exceptional vibrational sensitivity at high spatial resolution.

47 OTHER INSTRUMENTATION↗

Nonresonant corrections for the optical resonance frequency measurements in the hydrogen atom

The deviation of the natural spectral line profile from the Lorentz shape for the optical resonant frequency measurements is considered. This deviation leads to an asymmetry, which is mainly due to nonresonant correction to the resonant Lorentz profile. The nonresonant corrections are studied for the different types of the atomic resonant experiments. The most accurate recent optical resonance experiments are analyzed, i.e., the two-photon 1s-2s resonance excitation of the hydrogen atom with the delayed decay in the external electric field. The description of the nonresonant correction in the latter case requires the employment of QED with different in and out Hamiltonians. The nonresonant corrections for this experiment are investigated and found to be about 10{sup -5} Hz, while the recent experimental uncertainty is 34 Hz and in the near feature is expected to be a few hertz. The projected 1s-2s resonance excitation experiment with the three-photon ionization detection (which is now in progress) is also considered.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-precision frequency measurement of the 423-nm Ca i line

We have performed an accurate frequency calibration of the 4s{sup 2} {sup 1}S{sub 0{yields}}4s4p {sup 1}P{sub 1} principal resonance line of the neutral calcium atom at 423 nm. Doppler-free cw excitation on a Ca atomic beam was performed by utilizing a Sagnac geometry in the alignment of the excitation beams. From frequency calibrations against a frequency comb, stabilized to a global positioning system (GPS) disciplined Rb standard, the transition frequency is determined at 709 078 373.01(35) MHz for the main {sup 40}Ca isotope. Slightly lower accuracies are obtained for the transition frequencies of the less abundant isotopes. The achieved fractional uncertainty of 5x10{sup -10} exceeds the requirements for including this transition in investigations that aim to probe a possible variation in the fine-structure constant {alpha} on cosmological time scales.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Apparatuses and methods for testing electrochemical cells by measuring frequency response

Real-time battery impedance spectra are acquired by stimulating a battery or battery system with a signal generated as a sum of sine signals at related frequencies. An impedance measurement device can be used to interface between the battery system and a host computer for generating the signals. The impedance measurement device may be calibrated to adapt the response signal to more closely match other impedance measurement techniques. The impedance measurement device may be adapted to operate at mid-range voltages of about 50 volts and high-range voltages up to about 300 volts.

25 ENERGY STORAGE↗

Apparatuses and methods for testing electrochemical cells by measuring frequency response

Real-time battery impedance spectra are acquired by stimulating a battery or battery system with a signal generated as a sum of sine signals at related frequencies. An impedance measurement device can be used to interface between the battery system and a host computer for generating the signals. The impedance measurement device may be calibrated to adapt the response signal to more closely match other impedance measurement techniques. The impedance measurement device may be adapted to operate at mid-range voltages of about 50 volts and high-range voltages up to about 300 volts.

Christophersen, Jon P.↗

Method of detecting system function by measuring frequency response

Methods of rapidly measuring an impedance spectrum of an energy storage device in-situ over a limited number of logarithmically distributed frequencies are described. An energy storage device is excited with a known input signal, and a response is measured to ascertain the impedance spectrum. An excitation signal is a limited time duration sum-of-sines consisting of a select number of frequencies. In one embodiment, magnitude and phase of each frequency of interest within the sum-of-sines is identified when the selected frequencies and sample rate are logarithmic integer steps greater than two. This technique requires a measurement with a duration of one period of the lowest frequency. In another embodiment, where selected frequencies are distributed in octave steps, the impedance spectrum can be determined using a captured time record that is reduced to a half-period of the lowest frequency.

25 ENERGY STORAGE↗

CROCUS High-Frequency Measurements of CO₂, H₂O, Wind, and Temperature at University of Illinois Chicago

As of April 9, 2026: this dataset is currently being versioned to include data up to March 31, 2026. Once the versioning process is complete, new data files will be available for access. The dataset metadata will also be updated to reflect the data availability of the new data being versioned. Raw atmospheric measurements collected at the University of Illinois Chicago (UIC) as part of the Community Research on Climate and Urban Science (CROCUS) project. The data includes high-frequency measurements of carbon dioxide (CO₂) concentration, water vapor (H₂O) concentration, wind speed (U, V, W components), temperature, and atmospheric pressure. These raw data are recorded by the LI-7500DS Open Path CO₂/H₂O Analyzer and a sonic anemometer at a 10 Hz acquisition frequency, providing the necessary inputs for calculating fluxes of CO₂, H₂O, heat, and momentum. In addition to gas concentration measurements, the dataset includes diagnostic information from the instruments, including absorptance, sample and reference signals, and diagnostic values. The data were collected to study urban atmospheric conditions and contribute to flux calculations for urban climate research. These measurements form the basis for calculating 30-minute average fluxes of key atmospheric variables using the eddy covariance method. This dataset provides critical raw input data for researchers interested in atmospheric fluxes, urban air quality, and the interaction between the urban environment and atmospheric processes. The data is part of the U.S. Department of Energy’s Biological and Environmental Research (BER) program, under the CROCUS Urban Integrated Field Laboratory (UIFL) project.

54 ENVIRONMENTAL SCIENCES↗