Search NASA⌕ Search

SEARCH · Search NASA

Results for “Friction Factor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Experimental Study on the Effect of Localized Blockages on the Friction Factor of a 61-Pin Wire-Wrapped Bundle

Abstract The thermal-hydraulic behavior of the flow in rod bundles has motivated numerous experimental and computational investigations. Previous studies have identified potential for accumulation of debris within the small subchannels of typical wire-wrapped assemblies with subsequent total or partial blockage of subchannel coolant flow. A test campaign was conducted to study the effects of localized blockages on the bundle averaged friction factor of a tightly packed wire-wrapped rod bundle. Blockages were installed within the bundle, and fluid pressure drop was measured across one wire pitch for a Reynolds number range of 500–17,200. The Darcy–Weisbach friction factor of the perturbed rod bundle geometry was compared with that of the unblocked bundle, as well as with the predictions of a well-established friction factor correlation. Differing effects based on blockage size and location for various flow regimes were studied. A number of conclusions can be made about the effects of the blockages on the friction factor, such as an increasing effect of the blockage on friction factor with an increase in Reynolds number, a change in flow behavior in the turbulent transition flow regime near Reynolds number 3000, differences in effect on friction factor for different types of subchannel blockage, and a nonlinear trend in friction factor variation with flow area impeded for edge subchannels. To this end, all data and quantified uncertainty produced in this study are made available for comparison and validation of advanced computational tools.

Engineering↗

Calculation of Friction Factors in Heat Pipes Using CFD in Support of the Sockeye Code

A heat pipe is two-phase heat transfer device which relies on surface tension and capillary pressure to provide a very efficient heat transfer mechanism. Currently, there is interest in designing micro nuclear power reactors using high temperature heat pipes to provide totally passive cooling. To support this, Sockeye is being developed as a heat pipe simulation capability. To support the development of Sockeye, individual phenomena must be tested. This work focuses on applying a CFD model to evaluate friction factors for use in Sockeye. A CFD model has been developed in Nek5000 which simulates each component fluid, i.e. sodium liquid and vapor, independently and captures the effects of the wick on friction factor. The model tests the effect of the wick permeability and the thickness of the wick occupied by each fluid component. The thickness of the wick occupied by each component can be directly related to the local vapor volume fraction from the Sockeye heat pipe model. Results from the CFD model indicate that friction factor in the liquid flow decreases with increasing wick permeability, while the friction factor in the vapor flow increases with increasing wick permeability. In the liquid, this is likely a direct result of the increased cross sectional area available for the flow. For the vapor, this is explained as the wick acting like a rough wall, while the increased area has only a negligible impact. Results for the tests of the thickness of the wick occupied by each fluid showed a thresholding behavior for both liquid and vapor. When the thickness of the wick occupied by each fluid was increased, it increased the effect of the wick, but only up to a certain point. Once a certain thickness was reached, the friction factors remained constant. When the fluid occupied only a very small fraction of the wick, friction factors returned to nominal values.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Convective heat transfer and friction factor characteristics of molten salts in spirally fluted tubes

Spirally fluted tubes have been widely used for heat exchangers due to their superior heat transfer enhancement. However, most of the previous studies focused on the effects of a limited number of geometric parameters, i.e., the flute pitch and flute depth, on convective heat transfer and friction factor characteristics of low-Prandtl-number fluids, i.e., air and water. The correlations developed in these studies may not be accurate or applicable for medium-Prandtl-number fluids, such as molten salts. A numerical analysis using a Computational Fluid Dynamics (CFD) tool, STAR–CCM+, is therefore carried out in this study to systematically investigate the effects of four geometric parameters, including the flute pitch ρ, flute depth e, flute start number N s (or flute helix angle θ), and trough length L tr on convective heat transfer and friction factor characteristics of a medium-Prandtl-number fluid, FLiNaK (46.5LiF-11.5NaF-42KF mol %), in spirally fluted tubes. Additionally, the convective heat transfer and Darcy friction factor correlations are proposed and validated, with ± 20% uncertainties, for medium-Prandtl-number fluids under the following conditions: Re = 88–1600, Pr = 2.5–40, ρ/D c = 0.44–3.51, e/D c = 0.10–0.40, θ/90= 0.20–0.81, and L tr /D c = 0.71–2.16. The correlations proposed help improve the design of spirally fluted-tube heat exchangers.

42 ENGINEERING↗

Performance evaluation of finned tube heat exchanger using curved wavy delta winglet vortex generators with circular perforations

Vortex generation is recognized as an effective passive approach to improve the heat transfer rate in fin and tube heat exchangers (FTHEs). The current study proposed innovative designs of curved wavy delta winglet vortex generators (CWDWVGs), both without and with circular perforations, to improve the heat transfer efficiency of FTHEs. There is potential to increase heat transfer performance further through various CWDWVG designs. Here, this study explores seven unique CWDWVG configurations, from 1-wave to 7-wave. A 3-D computational numerical model is utilized to evaluate the Thermo-hydraulic performance of FTHEs fitted with these different CWDWVG configurations across Reynolds numbers from 400 to 2000. This comparative analysis of the Thermo-hydraulic performance of FTHEs featuring four parallel circular tube layouts assesses configurations both with and without vortex generators (VGs) and various hole configurations. The evaluation of Thermo-hydraulic performance involves different parameters, including the London area goodness factor (LAGF), Colburn factor (j), friction factor (f), pressure drop (?P), and Nusselt number (Nu). Results demonstrate that the various CWDWVG configurations and the number of holes in them substantially affect the efficiency, as evaluated by the dimensionless Performance Evaluation Criteria (PEC). Notably, the 7-wave CWDWVGs surpassed other configurations, and integrating circular punched perforations further improved the thermal-hydraulic performance of FTHE. Specifically, the 7-wave CWDWVGs without holes demonstrated superior performance over other configurations, showing a significant increase in Nusselt number by 75.18% and 85.16% at Reynolds numbers of 2000 and 400, respectively, alongside an increase in pressure drop by 216.38% to 224.96%. Meanwhile, the 7-wave CWDWVGs with eight holes, in comparison to those without holes, exhibited a Nusselt number increase of 0.85%, a pressure drop decrease of 7.31%, and a reduction in the friction factor by 5.82%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat Transfer Coefficients of Additively Manufactured Tubes with Internal Pin Fins for Supercritical Carbon Dioxide Cycle Recuperators

This paper describes the measurement of convective heat transfer coefficients and friction factors for sCO 2 flowing in additively manufactured tubes with internal pin fins at the US DOE’s National Energy Technology Laboratory in Morgantown, WV. The measurement procedures were validated by conducting benchmark tests with smooth stainless-steel tube and comparing the results with published correlations for Nusselt number (Nu) and friction factor. Over Reynolds numbers (ReD) ranging from 5 × 10 4 to 2.5 × 10 5 , measured Nu was within 5% of the Dittus-Boelter correlation and measured friction factors were within 5% of the McAdams correlation for smooth tube flow. The candidate pin fin patterned pipes were additively manufactured (AM) at the Oak Ridge National Laboratory. The pins were circular or elliptical in cross-section and were printed at a 30⁰ angle relative to the inner wall (to meet AM constraints). The pin arrangement was helical to promote enhanced heat transfer due to swirl flow. Pin length to diameter aspect ratio was 1.33, 2, and 8, while the pin diameter to tube diameter ratio was 0.188, 0.125, and 0.063. Tests were performed for ReD varying from 6.9 × 10 4 to 2.2 × 10 5 and at conditions equivalent to the low pressure (LP) outlet (8.69 MPa, 361 K) and the high pressure (HP) inlet (20.7 MPa, 350 K) of the low temperature recuperator (LTR) in an indirect sCO 2 cycle. The Wilson plot technique was utilized to measure the bulk heat transfer coefficients. For the best performing design (tube A, pin length to tube diameter ratio: 1.33, pin diameter to tube diameter ratio: 0.19), the local heat transfer coefficient increased by 136% relative to the Dittus-Boelter correlation at the LTR low pressure outlet and 194% at the LTR high pressure inlet. These correspond to a 282% and a 271% increase in the product of the heat transfer coefficient and surface area (adjusted for fin efficiency) product, respectively. Large pressure drops across the test articles were observed. For Tube Design A, the average friction factor, across the range of ReD considered, was significantly larger than the McAdams correlation at both the LTR LP outlet and the LTR HP inlet. A thermal performance factor was utilized to express the ratio of material required to build a finned heat exchanger relative to a finless heat exchanger with the same heat duty and pumping power. Tube Design A was estimated to decrease the required heat exchanger material by 13%.

Searle, Matthew↗

Pressure Drop in Seven-Pin Wire-Wrapped Rod Bundle for the Sodium Cartridge Loop in Versatile Test Reactor

This work studies the hydrodynamics of the seven pin wire-wrapped rod bundle in the sodium cartridge loop for the Versatile Test Reactor (VTR) through scaled water experiments and computational fluid dynamics (CFD) simulations. Here, the scaling analysis is first performed to demonstrate the hydrodynamic similarity between water and sodium flows at the same Reynolds number Re. A separate-effects test facility is designed and constructed based on the scaling analysis. Detailed experimental data on the pressure drop covering a wide range of Re values (1165 to 27 689) are obtained, which are used to evaluate existing correlations for friction factor and to benchmark CFD simulations. The experimentally determined friction factors f Exp agree well with the Upgraded Cheng and Todreas Detailed Correlation and Pacio-Chen-Todreas Detailed Model within ±7% but are significantly underpredicted by Rehme's correlation by 25%. Various CFD near-wall treatment methods are tested using ANSYS Fluent and evaluated by experimental data. It is found that when the recommended wall y + values are met, most of the near-wall treatment methods can give accurate friction factor predictions. The resolved near-wall method (y + ~ 1) with the Shear Stress Transport k - ω turbulence model and the scalable wall functions (y + > 12) with the realizable k - ε turbulence model can predict f Exp within ±5% The standard wall functions (y + > 30) and nonequilibrium wall functions (y + > 30) with the realizable k - ε model can predict f Exp within ±10%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SAS4A/SASSYS-1 Modeling Improvements for the Transition to Natural Circulation

SAS4A/SASSYS-1 (SAS) is a simulation tool used to perform deterministic analyses of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. With its origin as SAS1A in the late 1960s, the SAS series of codes has been under continuous use and development for over fifty years and represents a critical investment in safety analysis capabilities for the U.S. Department of Energy. In recent years, SAS has undergone a number of improvements to enable improved safety analyses that meet end users’ modernized needs while complying with the current regulatory environment. Improvements made in versions 5.6 and 5.7 released within the last year include the development of anisotropic Reynolds number dependent loss coefficients throughout the core and heat transport systems, the ability to distinguish the transition friction factor from the fully developed laminar and turbulent friction factors, and timedependent direct coolant and wall heating for pipe-like elements in the heat transport systems. While it was possible to capture loss coefficients, friction factors, and heat transfer from an element to a heat sink within SAS in previous versions of the code, users were required to end the simulation and restart it to adjust the input to account for any significant changes to the values during the transient. With these improvements, users can better capture flow reversal, pump heating, and the transition from forced to natural circulation without being limited to constant orifice coefficients, constant heat sinks, or the need to restart the simulation and modify input. In order to demonstrate the application of these improvements, a loss of flow transient is simulated for the Advanced Burner Test Reactor (ABTR).

SAS4A/SASSYS-1↗

Heat Transfer and Pressure Loss of Additively Manufactured Internal Cooling Channels With Various Shapes

Abstract Additive manufacturing (AM) provides the ability to fabricate highly customized internal cooling passages that are relevant to gas turbine components. This experimental study examines the pressure loss and heat transfer performance of a range of fundamental channel shapes that were produced using direct metal laser sintering. Circular, hexagonal, pentagonal, elliptical, diamond, square, rectangular, trapezoidal, and triangular channel cross sections were investigated. To maintain the same convective surface area between shapes, the wetted perimeters of the channel cross sections were kept constant. Parallel computational fluid dynamic simulations were performed to understand the relationships in cooling performance between several channel shapes. Several characteristic length scales were evaluated to scale the pressure loss and heat transfer measurements. Among the channel shapes investigated, the diamond channel showed the lowest Nusselt number and friction factor. The pentagon exhibited a similar Nusselt number as the circular channel despite having a lower friction factor. There was no difference in scaling the friction factor or Nusselt number results of the different channel shapes between using the square root of cross-sectional area compared to hydraulic diameter as the characteristic length scale

Engineering↗

EVALUATION OF PRESSURE DROP CORRELATIONS FOR THE WIRE-WRAPPED ROD BUNDLES

The accurate prediction of pressure drop in the fuel rod bundle is of importance for the design and thermal-hydraulic analysis of nuclear reactor system. Due to very complex geometry of wire-wrapped fuel rod bundle geometry for the Sodium Fast Reactor (SFR), a simple method using hydraulic (equivalent) diameter is not sufficient to predict the pressure drop of rod bundle accurately. For several decades, many experimental works have been performed to develop an accurate correlation for wire-wrapped fuel bundle friction factor. In these works, the friction factor correlation of wire-wrapped fuel bundle has been developed as a function of Reynolds number of the flow and the design parameters such as fuel pin diameter, wire diameter, rod pitch, and wire lead length. The Cheng and Todreas correlations are well-known and used in many subchannel analysis code, such as CADET, TRIO-U, MATRA-LMW, SE2-ANL, etc. Novendstern model, Rehme model, Baxi and Dalle Donne model are also well-known and widely referred. Computational Fluid Dynamics is another typical approach to predict the pressure drop of wire-wrapped fuel rod bundle, but it requires the model validation because the accuracy of pressure drop prediction by the CFD simulation depends on what turbulence model is employed. The present work aims at evaluating the existing pressure drop correlations for the wire-wrapped fuel rod bundle and evaluating the pressure drop of 217-pin rod bundle by the CFD analysis.

99 GENERAL AND MISCELLANEOUS↗

Surface Roughness Effects on Heat Transfer in Additively Manufactured sCO 2 Cycle Heat Exchangers

An experimental study was performed to consider the impact of surface roughness on heat transfer and pressure drop to supercritical carbon dioxide (sCO 2 ) in additively manufactured channels. All tests were performed in the Heat Exchange and Experimental Testing (HEET) rig at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) in Morgantown, West Virginia. Four test articles were considered. The first was a hydrodynamically smooth, drawn tube. The other three were additively manufactured channels with square and rectangular cross sections, which were characterized by sand-grain roughness to hydraulic diameter ratios spanning 0.0029 to 0.0073. Friction factors were determined by measuring the tube mass flow rate and pressure drop. The tube side heat transfer coefficient was measured using the Wilson plot technique. It was found that the friction factor results were 8% greater than the Colebrook correlation. Greater deviation was observed between the heat transfer results and the correlations. The Gnielinski correlation overpredicted the experimental points by nominally 30% and the Norris correlation overpredicting the experimental points by nominally 25%. A thermal performance factor was formed from the friction factor augmentation and Nusselt number augmentation results. These results indicated a 10% improvement in heat duty for a heat exchanger constructed utilizing a tube with ϵ/D_h =0.0073 relative to a heat exchanger utilizing a smooth, conventional tube.

36 MATERIALS SCIENCE↗

Fractal Model for Drag Reduction on Multiscale Nonwetting Rough Surfaces

Rough surfaces in contact with a flow of fluid exhibit alternating no-slip and free shear boundary conditions at the solid–liquid and air–liquid interfaces, respectively, thereby potentially offering drag reduction benefits. The balance between the dynamic pressure in the flow and the restoring capillary pressure in the interasperity spaces determines the stability of the Cassie state of wettability and is a function of the relative extent of no-slip and free shear regions per unit surface area. In the present study, using a fractal representation of rough surface topography, an analytical model is developed to quantify the stability of the Cassie state of wettability as well as drag reduction and the friction factor for laminar flow in a rectangular channel between nonwetting multiscale rough surfaces. A systematic study is conducted to quantify the effects of fractal parameters of the surfaces and the flow Reynolds number on drag reduction and the friction factor. The studies are used to develop friction factor curves extending the classical Moody diagram to hydrophobic and superhydrophobic surfaces. On the basis of the studies, regime maps are derived for estimating the extent of drag reduction offered by hydrophobic and superhydrophobic surfaces, revealing that superhydrophobic surfaces do not always offer the best drag reduction performance. The application of the fractal model to practical topographies of nonwetting surfaces of copper, aluminum, and zinc oxide fabricated via electrodeposition and etching is also discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling Flow in a Microreactor Core: From High-Fidelity CFD to Subchannel Analysis

The accurate prediction of pressure drop in tightly packed, low–Reynolds number (Re) bare rod bundles is essential for the thermal-hydraulic design of the Microreactor Applications Research Validation and EvaLuation (MARVEL) reactor and other microreactor concepts. However, existing friction factor correlations, particularly the upgraded Cheng-Todreas (UCTD) correlation, have limited validation for the small pitch-to-diameter ratios (P/Ds) and transitional flow conditions characteristic of these systems. In this work, we perform high-fidelity large-eddy simulations (LESs) of both an infinite bare rod bundle and a finite bare 37-pin scalloped rod bundle across the range 1000≤ 𝑅𝑒 ≤5500. The simulations reveal strong gap vortex–driven transitional behavior and indicate that the UCTD may underpredict the friction factor by up to 28% at 𝑃/𝐷 = 1.05. Using the LES-calculated pressure drops, we formulate a new friction factor correlation that follows the Cheng-Todreas functional form but is calibrated for low-Re and tightly packed geometries representative of a MARVEL-like reactor. The correlation is implemented in the MOOSE (Multiphysics Object-Oriented Simulation Environment) subchannel module and compared against both the LES and UCTD predictions. Across all subchannel types, the proposed model reduces the streamwise velocity differences from as high as 44% (UCTD) to below 9%, and decreases the pressure gradient differences from 13% to 25% (UCTD) to 0.7% to 7% relative to the LES results. These results suggest that the new correlation has the potential to improve the pressure drop and flow field predictions for such geometries, highlighting the importance of high-fidelity simulations in supporting microreactor thermal-hydraulic model development and motivating future pressure drop experiments for compact rod bundles to further validate these findings.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Optimization of Dimensions of Smooth and Twisted-Tape-Inserted Tubes for Heat Transfer with NaCl/KCl/MgCl 2 Molten Salts by Principle of Entropy Generation Minimization

The entropy generation minimization principle is used as the criterion to optimize the flow and heat transfer of solar collectors and heat exchangers that use molten salts NaCl–KCl–MgCl 2 and KCl–MgCl 2 . The Gnielinski correlation for the Nusselt number versus Reynolds number, as well as the Moody friction factor given by Petukhov, was used for the calculation of the convective heat transfer coefficient and pressure loss due to friction in smooth tubes. For twisted-tap-inserted tube, equations of Nu and friction factor provided by Manglik and Bergles were used. The objective function, the entropy generation rate of the heat transfer system, was expressed as the function of Reynolds number, Prandtl number, heating flux, tube diameter, etc. As a result of the analysis, the optimum Reynolds number was determined and thereby to determine the optimum Nusselt number, convective heat transfer coefficient, friction factor, and tube diameter, which also allows the calculation of optimum flow velocity. The analysis was conducted in the fluid temperature range of 500–700 °C, which covers the operation temperature for supercritical CO 2 power cycles in concentrated solar power (CSP) system. Here, optimized results from the smooth tube and twisted-tap-inserted tube are compared, which is important to the design of solar receivers for CSP systems.

14 SOLAR ENERGY↗

Measurement of Convective Heat Transfer Coefficients with Supercritical CO2 in Novel Additively Manufactured Helically Patterned Pin Fin Tubes Using the Wilson Plot Technique

This paper describes the measurement of convective heat transfer coefficients and friction factors for sCO2 flowing in pin-fin patterned pipes in the Heat Exchange and Experimental Testing (HEET) facility at the US DoE’s National Energy Technology Laboratory (NETL) in Morgantown, WV. The measurement procedures in the HEET rig were validated by conducting benchmark tests with smooth stainless-steel tube and comparing the results with published correlations for Nusselt number (Nu) and friction factor. Over typical Reynolds number range in sCO2, the measured Nu and friction factors were within 7% of classical correlations for smooth tube flow.The candidate pin fin patterned pipes were additively manufactured (AM) at the Oak Ridge National Laboratory. The pins were circular or elliptical in cross-section. Pin length to diameter aspect ratios were 1.33 and 2, while the pin diameter to tube diameter ratio was 0.188 and 0.125. Tests were performed for ReD varying from 6.9×104 to 2.2×105 and at conditions equivalent to the low pressure outlet (8.69 MPa, 361 K) of the low temperature recuperator (LTR) in an indirect sCO2 power cycle. The Wilson plot technique was utilized to measure the bulk heat transfer coefficients.For the better performing design (tube A, pin length to tube diameter ratio: 1.33, pin diameter to tube diameter ratio: 0.188), the local heat transfer coefficient increased by 112% relative to the Dittus-Boelter correlation at the LTR low pressure outlet. This corresponded to a 282% increase in the product of the heat transfer coefficient and the surface area. Large pressure drops across the test articles were observed.

Searle, Matthew↗

Measuring Heat Transfer Coefficients for Supercritical Carbon Dioxide Cycle Recuperators

This paper describes the measurement of convective heat transfer coefficients and friction factors for sCO 2 flowing in pin-fin patterned pipes at the US DoE’s National Energy Technology Laboratory (NETL) in Morgantown, WV. The measurement procedures were validated by conducting benchmark tests with smooth stainless-steel tube and comparing the results with published correlations for Nusselt number (𝑁𝑢) and friction factor. Over Reynolds numbers (Re D ) ranging from 5×104 to 2.5×105 , measured 𝑁𝑢 was within 5% of the Dittus-Boelter correlation and measured friction factors were within 5% of the McAdams correlation for smooth tube flow.

42 ENGINEERING↗

Optimization-Inspired Pin-Fin Array for Supercritical Carbon Dioxide Recuperator

Additively manufactured heat exchangers are one possible route to cost-effective sCO 2 power cycles. In this paper, experimental results are obtained for two helical pin fin tubes that were designed following parametric optimization of the fin array. Neither the numerical optimization nor the experimental testing have been previously reported in the literature. The two tube designs were, (1) the optimization inspired design, and (2) the optimization-inspired design with a fin diameter increased by a factor of 2. To characterize the print, the designs were scanned using X-ray computed tomography to measure feature sizes and heat transfer area. The optimization was conducted in a commercial, computational fluid dynamics code. The code solved the Reynolds Averaged Navier-Stokes (RANS) and energy equations with turbulence closure provided by the shear stress transport (SST) k-ω model. In the experiments, the Nusselt number augmentation was measured using the Wilson plot technique and the friction factor was determined with mass flow and pressure drop measurements. The experimental testing indicated that the optimization-inspired design had a friction factor that was four times less than the baseline tube design at equal Nusselt number. Additionally, the optimization-inspired design had a 14% improvement in Nusselt number, at equal friction factor, relative to the best performing computational fluid dynamics (CFD) trial points. Tube design (2), with the larger diameter pin fins, had similar performance, within experimental error, as the tube with the smaller diameter pin fins (1). Both tubes achieved overall fin array efficiencies near 1. A performance factor, V/V 0 , equal to the volume of the enhanced heat exchanger divided by the volume of the baseline (no-fins) heat exchanger, is recommended to quantify internal cooling performance. In conclusion, the experimental shell and tube heat exchanger, using the additively manufactured tube, is competitive with printed circuit heat exchangers in its pressure drop class and could be further improved by optimizing a shell-and-tube heat exchanger utilizing this heat transfer enhancement feature.

42 ENGINEERING↗

Measurement of Convective Heat Transfer Coefficients With Supercritical CO 2 Using the Wilson-Plot Technique

This paper describes the measurement of convective heat transfer coefficients and friction factors for sCO 2 flowing in a smooth tube and compares the results with published correlations for validation. The paper also describes the Heat Exchange and Experimental Testing (HEET) rig recently designed and built at the U.S. Department of Energy’s (DoE’s) National Energy Technology Laboratory (NETL) in Morgantown, WV. Here, the Wilson-plot technique used for measuring the heat transfer coefficients is described along with the data reduction process. The Wilson-plot technique was chosen as the basis for the design of NETL’s HEET rig. Advantages of the Wilson-plot technique include the (1) ability to measure high convective heat transfer coefficients accurately, (2) ability to measure average heat transfer coefficient for complicated heat exchange geometries like those produced using additive manufacturing, (3) ability to measure heat transfer coefficients on both sides of a heat exchanger independently, and (4) simplicity of experimental setup. Capabilities of the HEET rig include pressure to 24 MPa (3500 psig), temperature to 538 °C (1000 °F), mass flow rate to 1.5 kg/s (3 lb/s), and Re to 500,000. The rig is designed to operate with pure CO 2 or a mixture of CO 2 and up to 10% N2 by volume to study the impact of gas mixtures typical of direct-fired sCO 2 power cycles on the convective heat transfer and pressure drop. Preliminary tests in the HEET rig were performed with smooth stainless-steel tube and pure CO 2 , and the results were compared with published correlations for Nusselt number (Nu) and friction factor. Over a Reynolds number (Re) range from 58,000 to 228,000, measured Nu was compared to predictions using the Dittus and Boelter equation (Kreith and Bohn, 1993, “Principles of Heat Transfer, West Publishing Company”) within 5% and measured friction factors were compared to predictions using the McAdams correlation (“McAdams, 1954, “Heat Transmission,” 3rd ed., McGraw Hill, New York)” for smooth tube to be within 5%.

42 ENGINEERING↗

A Colebrook equation for impinging radial wall jets

Here, in this study, we evaluate the skin coefficient of friction for steady turbulent radial wall jets across smooth and rough surfaces. Although the Colebrook equation has been used successfully for many decades to evaluate friction factors for flows through smooth and rough pipes, how roughness affects the skin friction coefficient for steady turbulent radial wall jets remains unclear. Here we explore a Colebrook-type equation for skin friction coefficients associated with single-phase turbulent radial wall jets arising from orthogonally impinging circular jets. The fully iterative solution, based on well-established concepts of turbulent wall-bounded flow, is presented along with a power-law approximation and a non-iterative approximation for the friction coefficient derived therefrom. We find the skin coefficient of friction defined on the peak radial velocity to be a function of position over rough but not smooth surfaces in contrast to pipe friction factors that remain independent of axial position. These results follow expected trends, explain prior heterogeneity in power-law expressions for the skin friction coefficient and have significant implications for the industrial use of jets in mixing vessels.

friction losses↗