Search NASA⌕ Search

SEARCH · Search NASA

Results for “Frisch”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

An array of virtual Frisch-grid CdZnTe detectors and a front-end application-specific integrated circuit for large-area position-sensitive gamma-ray cameras

We developed a robust and low-cost array of virtual Frisch-grid CdZnTe (CZT) detectors coupled to a front-end readout ASIC for spectroscopy and imaging of gamma rays. The array operates as a self-reliant detector module. It is comprised of 36 close-packed 6x6x15 mm 3 detectors grouped into 3x3 sub-arrays of 2x2 detectors with the common cathodes. The front-end analog ASIC accommodates up to 36 anode and 9 cathode inputs. Several detector modules can be integrated into a single- or multi-layer unit operating as a Compton or a coded-aperture camera. We present the results from testing two fully assembled modules and readout electronics. The further enhancement of the arrays’ performance and reduction of their cost are made possible by using position-sensitive virtual Frisch-grid detectors, which allow for accurate corrections of the response of material non-uniformities caused by crystal defects.

36 MATERIALS SCIENCE↗

CZT Virtual Frisch-grid Detector: Principles and Applications

Cadmium Zinc Telluride (CdZnTe or CZT) is a very attractive material for using as room-temperature semiconductor detectors, because it has a wide bandgap and a high atomic number. However, due to the material's poor hole mobility, several special techniques were developed to ensure its suitability for radiation detection. Among them, the virtual Frisch-grid CZT detector is an attractive option, having a simple configuration, yet delivering an outstanding spectral performance. The goal of our group in Brookhaven National Laboratory (BNL) is to improve the performance of Frisch-ring CZT detectors; most recently, that effort focused on the non-contacting Frisch-ring detector, allowing us to build an inexpensive, large-volume detector array with high energy-resolution and a large effective area. In this paper, the principles of virtual Frisch-grid detectors are described, especially BNL's innovative improvements. The potential applications of virtual Frisch-grid detectors are discussed, and as an example, a hand-held gamma-ray spectrometer using a CZT virtual Frischgrid detector array is introduced, which is a self-contained device with a radiation detector, readout circuit, communication circuit, and high-voltage supply. It has good energy resolution of 1.4% (FWHM of 662-keV peak) with a total detection volume of {approx}20 cm{sup 3}. Such a portable inexpensive device can be used widely in nonproliferation applications, non-destructive detection, radiation imaging, and for homeland security. Extended systems based on the same technology have potential applications in industrial- and nuclear-medical-imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Study of Virtual Frisch Grid CdZnTeSe Detectors

Nuclear detectors for x-ray and gamma-ray spectroscopy and imaging are a vital tool in many homeland security, medical imaging, astrophysics and other applications. Most of these applications require room-temperature operation due to the operational constraints imposed by a cryogenic cooling system. CdZnTe (CZT) has been the main material with the desired detection properties, and CZT crystals have been used commercially for three decades. However, CdZnTe still suffers from long-standing issues of high densities of performance-limiting intrinsic defects such as Te inclusions and networks of dislocation walls (sub-grain boundaries). A recently invented new quaternary material CdZnTeSe showed excellent material properties for radiation detection. The material was found to be free from dislocation networks, possess reduced Te inclusions, and have better compositional homogeneity. Virtual Frisch grid detectors were fabricated from crystals taken from a CdZnTeSe ingot that was grown by the traveling heater method. The detectors were fabricated from an as-grown ingot, bypassing the post-growth annealing process commonly practiced for industrial-grade CZT. The performances of the detectors were studied with different Frisch grid lengths using an amplifier shaping time ranging from 1–6 µs. The detectors showed high-quality spectroscopic performance with an as-measured energy resolution of ~1.1% at 662 keV for an optimum Frisch grid length of 3 mm. The charge collection was observed to enhance for longer Frisch grids.

47 OTHER INSTRUMENTATION↗

Biparametric analyses of charge trapping in Cd{sub 0.9}Zn{sub 0.1}Te based virtual Frisch grid detectors

Detector grade Cd{sub 0.9}Zn{sub 0.1}Te (CZT) single crystals were grown from zone refined Cd, Zn, and Te ({approx}7 N) precursor materials, using a tellurium solvent method. Detectors with virtual Frisch grid configuration were fabricated using these crystals. I-V measurements revealed low leakage currents at room-temperature, {approx}11 nA for one such detector D1 and {approx}8 nA for another detector D2 at 1100 V. The spectroscopic performances of the two CZT virtual Frisch grid detectors have been evaluated and compared for high energy gamma ray detection. Detector D1 showed a well-resolved pulse-height spectrum with an energy resolution of {approx}1.6% for the 662 keV gamma rays. Detector D2 also showed a distinct 662 keV peak but with a broader pulse-height distribution. A digital biparametric correlation study of the depth of interaction and energy deposited by the 662 keV gamma rays was carried out. A different kind of correlation pattern from that observed normally for hole trapping was noticed in the case of detector D2. Correlation of results from thermally stimulated current measurement studies suggested that the anomalous biparametric correlation pattern was due to the trapping of holes but modified by the virtual Frisch grid effect. The results also suggested that the effect of electron trapping could not be ruled out either. Finally, a digital correction scheme was applied to recover the {sup 137}Cs spectrum from the effect of charge loss.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Front-end ASIC for spectroscopic readout of virtual Frisch-grid CZT bar sensors

Compact multi-channel radiation detectors rely on low noise front-end application specific integrated circuits (ASICs) to achieve high spectral resolution. Here, a new ASIC developed to readout virtual Frisch-grid cadmium zinc telluride (VFG CZT) detectors for gamma ray spectroscopy is presented. Corresponding to each ionizing event in the detector, the ASIC measures the amplitude and timing at the anode, the cathode and four pad sense electrodes associated with each sensor in a detector array. The ASIC is comprised of 52 channels of which there are 4 cathode channels and 48 channels which can be configured as either anode channels with a baseline of 250 mV or pad sense channels to process induced signals with a baseline of 1.2 V. With a static power dissipation of 3 mW, each channel performs low-noise charge amplification, high-order shaping, peak and timing detection along with analog storage and multiplexing. The overall channel linearity was better than ± 1% with timing resolution down to 700 ps for charges greater than 8 fC in the 3 MeV range. With a 4 × 4 array of 6 mm × 6 mm × 20 mm virtual Frisch-grid bar sensors connected and biased, an electronic resolution of ≈270 e - rms for charges up to 100 fC in the 3.2 MeV range was measured. Spectral measurements obtained with the 3D correction technique demonstrated resolutions of 1.8% FWHM at 238 keV and 0.9% FWHM at 662 keV.

3D↗

Hybrid Contacts for CZT Virtual Frisch-grid Detectors

In our previous design of virtual Frisch-grid CdZnTe (CZT) detectors, the charge drift-lines can be terminated at the side surfaces before the carriers reach the collecting anode; this results in a loss of signal from the interacting events near the detector's edges. Here, we describe our new design for the anode contact that reduces these edge effects by focusing the electric field towards the detectors' central axes. Four detectors were fabricated with the new hybrid anode contact, and their performances were evaluated and compared to those from the previous design for our virtual Frisch-grid detectors. The results obtained for all four showed similar improvement: therefore, we illustrate them with the findings from one detector.

54 ENVIRONMENTAL SCIENCES↗

Array of virtual Frisch-grid CZT detectors with common cathode readout and pulse-height correction

We present our new results from testing 15-mm-long virtual Frisch-grid CdZnTe detectors with a common-cathode readout for correcting pulse-height distortions. The array employs parallelepiped-shaped CdZnTe (CZT) detectors of a large geometrical aspect ratio, with two planar contacts on the top and bottom surfaces (anode and cathode) and an additional shielding electrode on the crystal's sides to create the virtual Frisch-grid effect. We optimized the geometry of the device and improved its spectral response. We found that reducing to 5 mm the length of the shielding electrode placed next to the anode had no adverse effects on the device's performance. At the same time, this allowed corrections for electron loss by reading the cathode signals to obtain depth information.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance characterization of 5×5×12 mm 3 virtual Frisch-grid TlBr detectors

Thallium bromide (TlBr) is a promising material for semiconductor gamma-ray detectors due to its high atomic number (Tl = 81, Br = 35), high density (7.56 g/cm 3 ), and relatively low melting point (460 °C). These properties give TlBr several competitive features, including high detection efficiency, good energy resolution, and lower fabrication costs, making it suitable for applications requiring compact, highly sensitive gamma-ray detection systems. Recent developments of TlBr detectors have progressed toward thicker crystals, up to 10–20 mm, configured as pixelated or virtual Frisch-grid (VFG) devices with volumes >1 cm 3 . Despite these advances, challenges remain in practical implementation, including material and fabrication issues that affect energy resolution, device stability, performance, and longevity. These challenges are similar to those faced by HgI 2 and lead-halide perovskite detectors. Here, this study presents results from characterizing over 100 position-sensitive 5×5×12 mm 3 virtual Frisch-grid detectors fabricated by Radiation Monitoring Devices Inc. For a prototype Radioisotope Identification Device (RIID). The work identified factors limiting the performance and longevity of TlBr detectors, including stochastic response variations that limit the energy resolution to 2–3 % (at 662 keV) for most devices, performance degradation associated with defect decoration, and contact delamination. Addressing these issues advances the use of TlBr and similar materials for reliable, high-resolution gamma-ray spectroscopy.

47 OTHER INSTRUMENTATION↗

Characterization of large-volume Frisch grid detector fabricated from as-grown CdZnTeSe

CdZnTe (CZT) has been under continuous development as a room-temperature radiation detector for the past 2-3 decades. Due to its intrinsic defects, such as a high concentration sub-grain boundary network, it has been very challenging to consistently produce high-quality CZT detectors with high yield, particularly for detector volumes exceeding a few cm 3 . In this paper, we report characterization of a relatively large-volume Frisch-grid detector (dimensions: 11x10.8x19.4 mm 3 ) fabricated from a new material Cd 0.9 Zn 0.1 Te 0.985 Se 0.015 . Furthermore, the detector was fabricated from an as-grown ingot with a two-inch diameter grown by the Traveling Heater Method (THM). The detector sample was evaluated by infrared (IR) transmission microscopy to study the presence of Te inclusions. X-ray topography using a synchrotron light source was deployed to measure the presence of sub-grain boundaries and their networks. Finally, the detector performance was measured for an optimized Frisch-grid length to extract the best energy resolution at room temperature.

36 MATERIALS SCIENCE↗

Hand-Held Gamma-Ray Spectrometer Based on High-Efficiency Frisch-Ring Cdznte Detectors

Frisch-ring CdZnTe detectors have demonstrated both good energy resolution, <1% FWHM at 662 keV, and good efficiency in detecting gamma rays, highlighting the strong potential of CdZnTe materials for such applications. We are designing a hand-held gamma-ray spectrometer based on Frisch-ring detectors at Brookhaven National Laboratory. It employs an 8 times 8 CdZnTe detector array to achieve a high volume of 19.2 cm3, so greatly improving detection efficiency. By using the front-end application-specific integrated circuits (ASICs) developed at BNL, this spectrometer has a small profile and high energy-resolution. It includes a signal processing circuit, digitization and storage circuits, a high-voltage module, and a universal serial bus (USB) interface. In this paper, we detail the system's structure and report the results of our tests with it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A linear array of position-sensitive virtual Frisch-grid CdZnTe for low-energy gamma rays

Large-area arrays of position-sensitive virtual Frisch-grid CdZnTe (CZT) detectors with enhanced energy resolution and high efficiency have been proposed for spectroscopy and imaging of gamma-ray sources. We present the design and test results of a linear array of such detectors optimized for use in handheld instruments. There are several application areas for such detectors including uranium enrichment measurements, storage monitoring, dosimetry and other nuclear safeguards related tasks. The array configuration provides a large area with minimum number of readout channels, which potentially allows the developers to avoid using ASIC-based readout electronics by substituting it with hybrid preamplifiers followed by digitizers. The array prototype consists of 6 5 x 7 x 25 mm 3 CZT detectors side-oriented with respect to the source to achieve the maximum area. Each detector is furnished with 5 mm-wide charge-sensing pads placed near the anode. As an option, the pads can be grouped together to reduce the number of readout channels. The same can be done with the cathodes. The pads signals are converted into X–Y coordinates and combined with the cathode signals (for the Z coordinates) to give 3D positional information of each interaction point. This information is used to correct the response non-uniformity caused by material inhomogeneity, which allows the developers to use standard grade (unselected) CZT crystals, while retaining high spectroscopic performance.

3D position-sensitive virtual Frisch-grid detector↗

A 4 x 4 array module of position-sensitive virtual Frisch-grid CdZnTe detectors for gamma-ray imaging spectrometers

Arrays of position-sensitive virtual Frisch-grid CdZnTe (CZT) detectors offer an economical approach to making high efficiency and high energy resolution gamma cameras for spectroscopy and imaging of radioactive sources. There are many application areas for such instruments including gamma-rays astronomy, medical and industrial imaging, nonproliferation and nuclear safeguards. We present the test results from a 4x4 array module coupled to the front-end ASIC. The array houses 16 detectors made of 6x6x20 mm 3 CZT crystals. Each crystal is encapsulated inside an ultrathin polyester shell and furnished with four 5-mm-wide charge-sensing pads placed near the anode on each side of the detector. The pad’s signals are used to measure X-Y coordinates while the cathode signals give the interaction depths (Z coordinates). Combined together the signals provide 3D position information of the interaction points which can be used to correct the detector response non-uniformity. This allows developers to use standard grade (unselected) CZT crystals while retaining high spectroscopic performance comparable with that of the H3D pixelated detectors. The array’s design provides flexibility to replace individual detectors and extend their sizes, potentially increasing upwards of 4 cm in height. We started development of position-sensitive VFG detectors several years ago and today this technology has reached a high-maturity level and is ready to use in practical applications.

3D charge-loss correction↗

Performance of 8 × 8 × 32 and 10 × 10 × 32 mm 3 CdZnTe position-sensitive virtual Frisch-grid detectors for high-energy gamma ray cameras

CdZnTe (CZT) crystals with thicknesses up to 20 mm and diameters up to 75 mm have become available from Redlen Technologies, Inc. for making large-volume gamma-ray detectors. The modified growth and optimized annealing conditions allowed Redlen to minimize the dark current and improve the uniformity of CZT crystals. Two detector designs, pixelated (H3D) and position-sensitive virtual Frisch-grid (VFG), have greatly benefitted from the availability of such big crystals. Encouraging results from testing of 40×40×15 mm 3 pixelated detectors were recently reported by the University of Michigan. In this work, we evaluated the spectroscopic properties of 8×8×32 and 10×10×32 mm 3 crystals configured as position-sensitive VFG detectors. Both digitized waveforms and an analog ASIC were used to read and process the signals from the detectors and test their spectral- and spatial-resolution. The VFG design provides the flexibility to scale-up the dimensions of the detectors for the desired efficiency, while the position information allows for correcting the detectors' response non-uniformity caused by crystal defects and devices geometry, thereby reducing the instrument cost and making them more feasible for emerging applications in gamma-ray astronomy, nonproliferation, portal screening and nuclear safeguards, where large detector arrays are often required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A virtual Frisch-grid geometry-based CZT gamma detector for in-field radioisotope identification

Here, we present a Virtual Frisch-Grid geometry-based CZT gamma detector developed for identifying different radioisotopes over an energy range from a few keV up to 2 MeV, and useful for efficient characterization of CZT crystals. The detector is built with a 3 x 3 matrix of CZT crystals, each measuring approximately 6 mm x 6 mm x 15 mm. The charge generated within the sensor’s active volume is read out via an anode connected directly to the AVG3_Dev integrated circuit. A current signal induced by charge drift is collected on side pads of the crystals, enabling reconstruction of a 3D interaction position. This paper discusses the design, development, and performance of the standalone, mobile detector system, which integrates the AVG3_Dev readout IC developed at Brookhaven National Laboratory, a high-speed FPGA-based with per-channel digital signal processing, and embedded system capabilities. The device is compact, battery-powered, and supports wireless data streaming, making it suitable for field operations for radioisotope identification.

47 OTHER INSTRUMENTATION↗

Mini Compton Camera Based on an Array of Virtual Frisch-Grid CdZnTe Detectors

In this study, we constructed a mini Compton camera based on an array of CdZnTe detectors and assessed its spectral and imaging properties. The entire array consisted of 6×6 Frisch-grid CdZnTe detectors, each with a size of 6×6 ×15 mm 3 . Since it is easier and more practical to grow small CdZnTe crystals rather than large monolithic ones, constructing a mosaic array of parallelepiped crystals can be an effective way to build a more efficient, large-volume detector. With the fully operational CdZnTe array, we measured the energy spectra for 133 Ba -, 137 Cs -, 60 Co-radiation sources; we also located these sources using a Compton imaging approach. Although the Compton camera was small enough to hand-carry, its intrinsic efficiency was several orders higher than those generated in previous researches using spatially separated arrays, because our camera measured the interactions inside the CZT detector array, wherein the detector elements were positioned very close to each other. Lastly, the performance of our camera was compared with that based on a pixelated detector.

36 MATERIALS SCIENCE↗

Arrays of Position-Sensitive Virtual Frisch-Grid CdZnTe Detectors: Results From a $4\times 4$ Array Prototype

Position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors offer a unique capability for correcting the response nonuniformities caused by crystal defects. This allowed us to achieve high energy resolution, while using typical-grade commercial CZT crystals with relaxed requirements to their quality, thus reducing the overall cost of detectors. Another advantage of the VFG detectors is that they can be integrated into arrays and used in small compact hand-held instruments or large-area gamma cameras that will enhance detection capability for many practical applications, including nonproliferation, medical imaging, and gamma-ray astronomy. Here in this paper, we present the results from testing small array prototypes coupled with front-end application-specified integrated circuit. Each detector in the array is furnished with 5-mm-wide charge-sensing pads placed near the anode. The pads signals are converted into XY coordinates, which combined with the cathode signals (for Z coordinates) provide 3-D position information of all interaction points. The basic array consists of a number of detectors grouped into 2×2 subarrays, each having a common cathode made by connecting together the cathodes of the individual detectors. Lastly, these features can significantly improve the performance of detectors while using typical-grade low-cost CZT crystals to reduce the overall cost of the proposed instrument.

3-D position-sensitive virtual Frisch-grid (VFG) d↗