Search NASA⌕ Search

SEARCH · Search NASA

Results for “Frost”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Methodology to evaluate design modifications intended to eliminate frosting and high discharge temperatures in air-source heat pumps (ASHPs) in cold climates

Air-source heat pumps (ASHPs) operating in cold climates experience problems with frosting and high refrigerant temperatures. These problems increase energy consumption, and their severity depends on the climatic conditions. In the present paper, a methodology for identifying the prevailing problem between frosting and high discharge temperatures is presented. Three performance indices, the frosting index (FI), the discharge index (DI), and the total loss index (TLI), are proposed to quantify the impacts of frosting and high discharge temperatures on the annual performance of ASHPs in different climatic conditions. The FI and DI show which problem (frosting or high discharge temperature) dominates, and the TLI indicates the combined effect of frosting and high discharge temperatures on the performance of an ASHP. A thermodynamic model of an ASHP coupled with the TRNSYS building simulation tool is used to estimate the performance of an ASHP and the proposed loss indices to estimate the impact of both frosting and high discharge temperatures for 45 cities in Canada. The results can be extended to other parts of the world that experience similar climatic conditions The results reveal that in cities in ASHRAE climatic zones 5 and 6 (classified as cold regions) where the ambient air temperatures are predominantly between -15 °C to 6 °C, ASHPs are heavily impacted by frosting. The problem of high discharge temperatures in ASHPs is predominant in cities in climate zones 7 and 8 (classified as very cold and subarctic regions) where the temperatures are frequently below -20 °C in winter. Among the cities considered, St. John, NL has the highest fraction of heating hours experiencing frosting (90 %), where the annual increase in energy consumption due to frosting is 13.5 % of the annual heating energy consumption. The highest annual increase in energy consumption due to high discharge temperatures is in Isachsen, NU (zone 8), where the increase is 30 % of the annual heating energy consumption. Based on the proposed indices, another index called the performance gain index (PGI) is created, which can be used as a first step to assess the energy-saving potential of design modifications applied to ASHPs to solve the problems of frosting and high discharge temperatures. The PGI will aid in developing climate specific ASHPs. One possible design modification is the use of a two-stage ASHP with an economizer. It is observed that the two-stage ASHP with economizer can mitigate high discharge temperatures and improve performance in very cold and subarctic regions (zones 7 and 8). However, it is not as beneficial in zones 5 and 6, where the impact of high discharge temperatures on performance is minimal and frosting dominates. Finally, a case study, using the PGI to evaluate the economic and environmental effectiveness of a two-stage ASHP with economizer is presented for the city of Saskatoon.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Review of Modeling Approaches for Predicting Frost Growth and Defrosting on Tube-Fin Heat Exchangers: Preprint

Frost formation and growth on the evaporator surface is a common process that deteriorates the air-refrigerant heat transfer and restricts airflow. This degrades the performance of the vapor compression system by increasing temperature lift and air-side pressure drop. To accurately predict these effects during coil frosting, as well as the energy use and duration of the defrost process, there is a need to estimate the heat and mass transfer, momentum transport, and solid-liquid and liquid-vapor phase change. Therefore, in the past few decades, continuous effort has been made to model frosting and defrosting processes using approaches ranging from empirical correlations to computational fluid dynamic models. To provide a clearer overview for researchers, engineers, and manufacturers in this field, this paper provides a comprehensive literature review for frosting and defrosting models. The paper begins with theoretical background of frost formation and defrost processes, and then reviews the common modeling approaches in literature and their underlying assumptions when trying to account for various physical phenomenon. Based on the literature review, the most critical modeling effort for frost formation is the determination of frost densification rate and frost growth rate. Various methods to predict these two parameters are reviewed. Empirical correlations commonly used for frost density and thermal conductivity are presented and compared. For the defrost process, various multi-stage models have been proposed with different assumptions. Some assume the presence of air gap between the tube wall and the frost, while others consider the melted frost flow due to gravity. We also review physics-based and empirical approaches to integrate defrost models into heat pump models. We conclude by identifying research gaps and providing recommendations.

defrost↗

A physics-based model for frost buildup under turbulent flow using direct numerical simulations

We present a new model for frost buildup under turbulent (and laminar) flow using direct numerical simulations. The physical model consists of two layers, the air and the frost. The air layer is fully resolved and consists of solving for the velocity, temperature, and vapor mass fraction fields. The frost layer thickness is resolved using conservation of mass and energy. Both phases are dynamically coupled using the immersed boundary method. Three-dimensional simulations are conducted in an open-channel configuration. A number of challenges need to be overcome to make these simulations feasible. First, to enforce far-field conditions of zero gradient and prescribed mean temperature and humidity, a source term is added to the energy and transport equations in the flow solver. Second, the mean frost thickness is subtracted after each time step to ensure a constant mean flow thickness and level of turbulence in the numerical domain. Third, a slow-time acceleration approach, which accelerates the frost buildup by a predetermined factor, is employed to bridge the gap between the fast turbulent and slow frost buildup time scales. Finally, a frost densification scheme is used to overcome the difficulties of vertically varying frost properties. The model is validated by comparing the frost thickness and frost thickness buildup rate over a period of one hour from a cooled flat plate experiment. As a result, both quantities compare favorably with experiments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Frost Tables, NGEE Areas B, C and D, Utqiagvik (Barrow), Alaska, 2012-2014

This dataset represents spatially intensive thaw depth surveys with individual point measurements spaced ~0.5 m apart. The three ~10x10m grids cover an ice wedge and a portion of its two neighboring polygons. The data contain thaw depth, frost table elevation, ground surface elevation, active layer depth and surface water inundation across three seasons (2012, 2013 and 2014) at Utqiagvik (Barrow) NGEE Areas B, C and D. There are a total of 69 extracted files separated by month, year, and area. The data were originally provided in excel workbooks, these files have been preserved within the zip "Original_Files." The files were transformed for archiving with images pulled out into JPEGs, data preserved as CSV files and some methodological information preserved as TXT files. Some functions, features, and formatting were lost during the transformation. Missing data were defined with blank cells. Additional documentation can be found in files labelled with "information.txt" file endings.The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska.Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).[2024-07-15] Renamed BEO_Thaw_Depth_Frost_Table_Area_*_*_*.csv, BEO_Thaw_Depth_Frost_Table_Area_*_*_*_Plot_1.JPEG, and BEO_Thaw_Depth_Frost_Table_Area_*_*_*_Plot_2.JPEG names that had E or L to be Early or Late. Renamed BEO_Thaw_Depth_Frost_Table_Area_*_*_*_Plot_1.JPEG, BEO_Thaw_Depth_Frost_Table_Area_*_*_*_Plot_2.JPEG, and BEO_Thaw_Depth_Frost_Table_Area_*_information_Plot_1.JPEG to BEO_Thaw_Depth_Frost_Table_Area_*_*_*_Gridpoints.JPEG, BEO_Thaw_Depth_Frost_Table_Area_*_*_*_3Dgraphic.JPEG, and BEO_Thaw_Depth_Frost_Table_Area_*_information_LiDAR_DEM.JPEG, respectively. Updated BEO_Thaw_Depth_Frost_Table_flmd.csv file to reflect above updates.

54 ENVIRONMENTAL SCIENCES↗

Integration of a Frost Mortality Scheme Into the Demographic Vegetation Model FATES

Frost is damaging to plants when air temperature drops below their tolerance threshold. The set of mechanisms used by cold-tolerant plants to withstand freezing is called “hardening” and typically take place in autumn to protect against winter damage. The recent incorporation of a hardening scheme in the demographic vegetation model FATES opens up the possibility to investigate frost mortality to vegetation. Previously, the hardening scheme was used to improve hydraulic processes in cold-tolerant plants. In this study, we expand upon the existing hardening scheme by implementing hardiness-dependent frost mortality into CLM5.0-FATES to study the impacts of frost on vegetation in temperate and boreal sites from 1950 to 2015. Our results show that the original freezing mortality approach of FATES, where each plant type had a fixed freezing tolerance threshold—an approach common to many other dynamic vegetation models, was restricted to predicting plant type distribution. The main results emerging from the new scheme are a high autumn and spring frost mortality, especially at colder sites, and increasing mid-winter frost mortality due to global warming, especially at warmer sites. We demonstrate that the new frost scheme is a major step forward in dynamically representing vegetation in ESMs by for the first time including a level of frost tolerance that is responding to the environment and includes some level of cost (implicitly) and benefit. By linking hardening and frost mortality in a land surface model, we open new ways to explore the impact of frost events in the context of global warming.

54 ENVIRONMENTAL SCIENCES↗

Frost prediction using machine learning and deep neural network models

This study describes accurate, computationally efficient models that can be implemented for practical use in predicting frost events for point-scale agricultural applications. Frost damage in agriculture is a costly burden to farmers and global food security alike. Timely prediction of frost events is important to reduce the cost of agricultural frost damage and traditional numerical weather forecasts are often inaccurate at the field-scale in complex terrain. In this paper, we developed machine learning (ML) algorithms for the prediction of such frost events near Alcalde, NM at the point-scale. ML algorithms investigated include deep neural network, convolution neural networks, and random forest models at lead-times of 6–48 h. Our results show promising accuracy (6-h prediction RMSE = 1.53–1.72°C) for use in frost and minimum temperature prediction applications. Seasonal differences in model predictions resulted in a slight negative bias during Spring and Summer months and a positive bias in Fall and Winter months. Additionally, we tested the model transferability by continuing training and testing using data from sensors at a nearby farm. We calculated the feature importance of the random forest models and were able to determine which parameters provided the models with the most useful information for predictions. We determined that soil temperature is a key parameter in longer term predictions (>24 h), while other temperature related parameters provide the majority of information for shorter term predictions. The model error compared favorable to previous ML based frost studies and outperformed the physically based High Resolution Rapid Refresh forecasting system making our ML-models attractive for deployment toward real-time monitoring of frost events and damage at commercial farming operations.

97 MATHEMATICS AND COMPUTING↗

Numerical simulation of frost formation and heat transfer on fin-and-tube heat exchangers in turbulent cross-flow

Frost formation in fin-and-tube heat exchangers in turbulent cross-flow presents significant challenges in industrial refrigeration applications, affecting heat transfer efficiency and operational reliability. The purpose of this work is to investigate frost deposition and growth on a staggered bank of a fin-and-tube freezer coil under turbulent forced convection conditions. The focus here is on investigating conditions that closely replicate real-world scenarios in large walk-in industrial freezers. Using a direct numerical simulation approach, we examine the flow dynamics and thermal behaviour in the presence of frost, considering turbulent regimes characterized by a Reynolds number in the range 1050 ≤ R e D , avg ≤ 4800 , with the characteristic length being the outer diameter of the tube and the velocity being the bulk fluid velocity between the plates (fins). Computational fluid dynamics simulations are employed to resolve the interactions between turbulent airflow and the frost layer. Our approach incorporates a modified immersed boundary method and a slow-time acceleration technique to address the complex dynamic interface between the continuously evolving frost layer and the flowing air stream. Our findings indicate that frost forms more on the sides of the finned surfaces (plates) and less on the tubes themselves. This article is part of the theme issue ‘Heat and mass transfer in frost and ice’.

Science & Technology - Other Topics↗

Advanced Frost Sensor for HVAC Applications

Frost is a common problem in heating, ventilation, and air conditioning (HVAC) systems that can degrade their efficiencies, leading to excessive electricity consumption. Appropriate defrosting is therefore essential for heat pumps and refrigeration systems. However, these systems typically run the defrost cycle based on a predetermined time interval, a method that does not accurately identify the amount of frost and thus consume excessive electricity. To substantially improve defrosting initiation and termination, this paper describes development of a smart sensor based on a capacitive sensing technique that can quantify frost accumulation and difference between frost, ice, and water. The reported sensor adopts interdigitated comb electrodes and can be updated to a potential multifunctional sensor array for the enhancing identification of frost, ice, and water with the integrated measurement of surface temperature, frost capacitance, and resistance. The proposed frost sensor is potentially expected to have widespread applications in HVAC systems, including heat pumps, refrigerators, and commercial refrigeration systems.

Gao, Zhiming↗

High-efficiency frost and ice control via sensing-assisted nanovibrational slippery surfaces

Frost and ice accretions on surfaces pose persistent challenges across numerous industrial, residential and transportation systems. While various removal strategies exist, they often suffer from limited effectiveness or high energy consumption, such as frosting delay, ice crack generation, and Joule heating. Here, in this work, we report a novel integrated approach combining vibrational quasi-liquid surface (QLS) and capacitive sensing for efficient condensate, frost, and ice management. Compared to Joule heating, our approach does not rely on complete melting and evaporation for removal, resulting in 68% and 95% energy savings for frost and ice removal, respectively. Our QLS coating significantly reduces surface retention forces, achieving 91% and 87% less residual mass compared to hydrophilic surfaces for frost and ice removal through surface nanovibration, respectively. The integrated capacitive sensor provides real-time detection of different phase states, enabling on-demand removal in precise timeframes. This sensor-assisted approach showed 3.8 times lower energy consumption compared to conventional Joule heating for defrosting. This synergistic integration of surface engineering, nanovibration, and intelligent sensing represents a significant advancement in phase change processes, offering an energy-efficient solution for frost and ice mitigation in energy-intensive systems.

Shen, Yuchen [Univ. of Texas at Dallas, Richardson↗

The effects of outdoor air-side fouling on frost growth and heat transfer characteristics of a microchannel heat exchanger: An experimental study

Air source heat pumps have the potential to efficiently heat and cool buildings, but their effectiveness in many climates is limited by frost growth on the outdoor heat exchanger in heating mode. These heat exchanger coils are also subject to fouling from fibers and particulates outdoors. Frost and fouling have each independently been studied extensively, and newly available research on fouling provides a method to realistically foul the air-side of coils in the laboratory. The current paper uses this method to conduct the first laboratory study of the important interactions between fouling and frost growth for a heat pump outdoor coil. A microchannel heat exchanger is tested clean and fouled, with variations in fouling level, humidity, and initial face velocity of air. Air flow rate is allowed to vary with resistance, and a surprising result is that light fouling increases heat transfer and frost growth rates, even with a 3.5% reduction in initial airflow caused by the fouling. However, heavier fouling decreases both rates. When frost growth is normalized to heat transfer, it is found to be increased by fouling; i.e. the coil’s sensible heat ratio decreases.

42 ENGINEERING↗

Superhydrophobic heat exchangers delay frost formation and enhance efficency of electric vehicle heat pumps

The number of electric vehicles has rapidly expanded as high-performance automotive lithium-ion batteries have become more affordable. However, the range of electric vehicles decreases in cold climates partly because of the additional thermal loads associated with cabin heating. One way to improve the efficiency of cabin heating is to replace resistive heating elements with an air-source heat pump system. However, to gain the full benefit of heat pumping, frost formation on the outdoor heat exchanger must be minimized. In this work, we modified the surface wettability of aluminum louvered-fin automotive heat pump evaporators and tested them under realistic operating conditions in a transcritical carbon dioxide (CO 2 ) heat pump. Each heat exchanger underwent several consecutive frosting and defrosting cycles to understand the cyclic performance of the system. The heat exchanger with a superhydrophobic outer surface was able to delay frost formation and maintain higher heat transfer rates when compared to heat exchangers with higher surface energies (hydrophilic). The delayed frost formation resulted in a system efficiency benefit in the first few frosting cycles but diminished in later cycles due to water retention and incomplete defrosting. However, for most automotive applications the superhydrophobic heat exchanger showed substantial benefits for normal driving trips. We report the scalable and optimized superhydrophobic heat exchangers developed here have the potential to increase the efficiency of automotive heat pumps and consequently increase the range and reduce energy consumption of electric vehicles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Frost Prevention for Heat Recovery Ventilation in an Arctic Facility

Sub-Arctic environments present a unique challenge for the continuous operation of mechanical ventilation systems in occupied buildings where cold temperatures create complications for maintaining adequate air quality, efficiency, and system operability. Heat recovery ventilation is most difficult at the coldest temperatures, when there is the greatest availability to transfer heat between airstreams, due to the potential for frost accumulation in the exhaust airstream. Frost limits heat transfer and creates the potential for subsequent blockage of airflow. A successful frost prevention strategy is necessary to ensure that recovery ventilation systems function in locations with a large amount of annual heating degree days. Commonly, this is achieved by preheating outdoor air above freezing temperatures via airflow through a glycol-water mix hydronic coil before heat exchange occurs. Preheating the outdoor air proactively inhibits frost formation but is associated with a penalty to recovery efficiency. A commercial-scale heat recovery ventilator in a facility in Fairbanks, Alaska was analyzed for sensible recovery effectiveness and exhaust temperature at different winter conditions. The system utilized the common defrost strategy of preheating the air above-freezing with a static temperature control scheme. The heat transfer efficiency of the recovery ventilator was observed to be poor at various winter conditions with elevated exhaust temperatures indicating lost heat recovery effectiveness. Using prior findings on strategies for sub-freezing temperatures along with observed field conditions it was determined that a dynamic relationship between the coil and the exterior conditions would reduce the energy required to preheat the air and allow the heat exchanger to maximize effectiveness due to temperate difference. This reduction in preheated temperature of the air is achieved by modulating the temperature of the coil to keep the discharge air stream above a certain dewpoint temperature threshold, likely leading to energy savings for other sub-Arctic facilities using this frost control strategy.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Soil frost controls streamflow generation processes in headwater catchments

The relationship between snowmelt and spring streamflow is changing under warming temperatures and diminishing snowpack. At the same time, the hydrologic connectivity across catchment landscape elements, such as snowpack and surface wetlands, can play a critical role in controlling the routing of snowmelt to streams. The role of hydrologic connectivity is important in headwater regions of the continental northern latitudes, where catchments have low topographic relief and seasonally frozen ground. Nevertheless, the effects of soil frost on the sequence, timing, and magnitudes of hydrologic events that drive the movement of water from a snowpack to a stream are not fully understood. Therefore, we examine two questions: First, what is the flowpath that snow melt and precipitation from spring rain events takes to generate spring streamflow, and second, what hydrologic, climatic, or landscape variables exert the most control on the magnitude of streamflow? In this work, we use long-term hydrological records from the two reference basins at the Marcell Experimental Forest in northern Minnesota to analyze the cascading effects across precipitation, snow, water table elevation, soil frost, and streamflow in peatland-dominated headwater catchments. We identify a sequence of fill-and-spill effects across the landscape that control the timing of spring streamflow generation. Then, we use stepwise regression to show that soil frost is a key supporting predictor for both the magnitude of streamflow in the spring as it adds significantly to the predictive power of precipitation and water table elevation. Our results highlight the importance of recognizing the role of soil frost, when present, on the partitioning of snowmelt between overland runoff and water table recharge during the critical snowmelt period, as well as the later partitioning between evapotranspiration and subsurface flows.

54 ENVIRONMENTAL SCIENCES↗

Advanced defrosting techniques in air source heat pumps: A review of vapor injection, thermal energy storage, and experimental frost accumulation data

Electrification is a critical step for reducing greenhouse gas emissions from heating. Air source heat pumps (ASHPs) are a promising alternative to fossil fuel-based systems due to their high coefficients of performance (COP), dual heating and cooling capability, and lower carbon footprint. However, for ASHPs to achieve widespread adoption, they must operate reliably across all climates, including cold regions. Additionally, defrosting techniques should be energy efficient and minimally disruptive to indoor comfort. Vapor injection (VI) technology can address the high-pressure and high-temperature lift challenges encountered in low ambient conditions. More recently, in addition to enhancing heating performance, VI has also been shown to improve the speed and efficiency of reverse cycle defrosting. Likewise, thermal energy storage (TES) has steadily gained attention for its ability to serve as an auxiliary heat source during both normal operation and defrosting. This review analyzes the benefits and limitations of VI- and TES-assisted defrosting approaches. While both technologies show strong potential individually, no studies to date have explored their combined use in ASHP systems. Additionally, to support continued development of defrosting strategies, both in modeling and experimental work, it is critical to establish frost accumulation data under a range of operating conditions. By compiling the available data from the literature, this paper also highlights the limited availability of such experimental data and the wide variation in frosting and defrosting durations and termination criteria, which are often influenced by system design and test setups.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Accurate expressions for the dew point and frost point derived from the Rankine-Kirchhoff approximations

Accurate, explicit, and analytic expressions are derived for the dew point and frost point as functions of temperature and relative humidity. These are derived theoretically in terms of physical constants using the Rankine-Kirchhoff approximations, which assume an ideal gas, fixed heat capacities, and zero specific volume of condensates. Compared to modern laboratory measurements, the expressions are accurate to within a few hundredths of a degree over the full range of Earth-relevant temperatures, from 180 to 273 K for the frost point and 230 to 330 K for the dew point.

54 ENVIRONMENTAL SCIENCES↗

Development and Application of High-Fidelity Models for Heterogeneous CO2 Frost Formation

Carbon America has developed a cryogenic carbon capture technology ("FrostCC") that separates CO2 from point source emissions by solidifying it at cold temperatures through preferential desublimation. Cooling is achieved through a series of interlinked compression, heat exchange, and expansion operations. In the current system, frosting of CO2 happens in heat exchangers, followed by CO2 recovery in a separate extraction step. In this work, multiphysics computational fluid dynamics (CFD) models are developed and validated for compressible and low Mach flows to simulate the formation of solid CO2 in flue gas flowing in a heat exchanger geometry. The models track the mass transfer rate of CO2 from gas phase to solid phase, heat released from desublimation, and the evolution of the solid CO2 layer. Simulations are used to answer scientific questions related to the angle of heat exchanger pipes, where buoyancy effects from flow velocity and pipe orientation influence CO2 frosting. Results show that upwardly angled pipes produce notably different flow structures compared to horizontal or vertical configurations, and that carbon capture efficiency correlates with buoyancy effects for pipe angles within plus or minus 23 degrees of horizontal.

97 MATHEMATICS AND COMPUTING↗

Inclusion of a cold hardening scheme to represent frost tolerance is essential to model realistic plant hydraulics in the Arctic–boreal zone in CLM5.0-FATES-Hydro

As temperatures decrease in autumn, vegetation of temperate and boreal ecosystems increases its tolerance to freezing. This process, known as hardening, results in a set of physiological changes at the molecular level that initiate modifications of cell membrane composition and the synthesis of anti-freeze proteins. Together with the freezing of extracellular water, anti-freeze proteins reduce plant water potentials and xylem conductivity. To represent the responses of vegetation to climate change, land surface schemes increasingly employ “hydrodynamic” models that represent the explicit fluxes of water from soil and through plants. The functioning of such schemes under frozen soil conditions, however, is poorly understood. Nonetheless, hydraulic processes are of major importance in the dynamics of these systems, which can suffer from, e.g., winter “frost drought” events. In this study, we implement a scheme that represents hardening into CLM5.0-FATES-Hydro. FATES-Hydro is a plant hydrodynamics module in FATES, a cohort model of vegetation physiology, growth, and dynamics hosted in CLM5.0. We find that, in frozen systems, it is necessary to introduce reductions in plant water loss associated with hardening to prevent winter desiccation. This work makes it possible to use CLM5.0-FATES-Hydro to model realistic impacts from frost droughts on vegetation growth and photosynthesis, leading to more reliable projections of how northern ecosystems respond to climate change.

58 GEOSCIENCES↗

TBS FROST Data from 2023 at SGP C1

The FROST provides chemical analysis of four time-resolved sorbent samples on a LECO GCxGC Bench Time of Flight Mass Spectrometer, using a Gerstel MPS Thermal Desorption System. Samples collected via FROST can be analyzed on one of two Sandia National Laboratories' instruments. One instrument will provide ultra-high mass spectrometer resolution (up to four decimal points or m/z data) and can be used for identification of true unknowns. Data can include suspected formulas of species not included in any current mass spectra database. This instrument also has a low limit of detection of known species (tens of femtogram range). The second instrument can provide an order of magnitude lower limits of detection (into the single-digit femtogram range) for known species currently in mass spectra databases. This system is also more resilient to environmental samples that contain higher levels of moisture.

54 ENVIRONMENTAL SCIENCES↗