KENO V.a Primer: Performing Calculations using SCALE’s Criticality Safety Analysis Sequence (CSAS5) with Fulcrum

The SCALE code system developed at Oak Ridge National Laboratory is widely used and accepted around the world for criticality safety analyses. The well-known KENO V.a three-dimensional Monte Carlo criticality computer code is one of the primary criticality safety analysis tools in SCALE. The KENO V.a primer is designed to help a new user understand and use the SCALE/KENO V.a Monte Carlo code for nuclear criticality safety analyses. It assumes that the user has a college education in a technical field. There is no assumption of familiarity with Monte Carlo codes in general or with SCALE/KENO V.a in particular. The primer is designed to teach by example, with each example illustrating two or three features of SCALE/KENO V.a that are useful in criticality analyses. The primer is based on SCALE 6.2 and 6.3, which includes the Fulcrum graphical user interface (GUI). Each example uses Fulcrum to provide the framework for preparing input data and viewing output results. Starting with a Quickstart section, the primer gives an overview of the basic requirements for SCALE/KENO V.a input and allows the user to quickly run a simple criticality problem with SCALE/KENO V.a. The sections that follow Quickstart include a list of basic objectives at the beginning that identifies the goal of the section and the individual SCALE/KENO V.a features that are covered in detail in the sample problems in that section. Upon completion of the primer, a new user should be comfortable using Fulcrum to set up criticality problems in SCALE/KENO V.a. The primer provides a starting point for the criticality safety analyst who uses SCALE/KENO V.a. Complete descriptions are provided in the SCALE/KENO V.a manual. Although the primer is self-contained, it is intended as a companion volume to the SCALE/KENO V.a training and documentation. The SCALE manual and training schedule are available at https://scale.ornl.gov. The primer provides specific examples of using SCALE/KENO V.a for criticality analyses; the SCALE/KENO V.a manual provides information on the use of SCALE/KENO V.a and all its modules. The primer also contains an appendix with sample input files. In addition, this primer, its errata and sample inputs are also available at https://code.ornl.gov/scale/primers/kenova.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

KENO-VI Primer: Performing Calculations using SCALE’s Criticality Safety Analysis Sequence (CSAS6) with Fulcrum

The SCALE code system developed at Oak Ridge National Laboratory is widely used and accepted around the world for criticality safety analysis. The well-known KENO-VI three-dimensional Monte Carlo criticality computer code is one of the primary criticality safety analysis tools in SCALE. The KENO-VI primer is designed to help a new user understand and use the SCALE/KENO-VI Monte Carlo code for nuclear criticality safety analysis. It assumes that the user has a college education in a technical field. There is no assumption of familiarity with Monte Carlo codes in general or with SCALE/KENO-VI in particular. The primer is designed to teach by example, with each example illustrating two or three features of SCALE/KENO-VI that are useful in criticality analysis. The primer is based on SCALE 6.2 and 6.3, which includes the Fulcrum graphical user interface. Each example uses Fulcrum to provide the framework for preparing input data and viewing output results. Starting with a Quickstart section, the primer gives an overview of the basic requirements for SCALE/KENO-VI input and allows the user to quickly run a simple criticality problem with SCALE/KENO-VI. Each following section begins with a list of basic objectives identifying the goal of the section and the individual SCALE/KENO-VI features covered in detail in the section’s sample problems. Upon completion of the primer, a new user should be comfortable using Fulcrum to set up criticality problems in SCALE/KENO-VI. The primer provides a starting point for the criticality safety analyst who uses SCALE/KENO-VI. Complete descriptions are provided in the SCALE/KENO-VI manual. Although the primer is self-contained, it is intended as a companion volume to the SCALE/KENO-VI training and documentation. The SCALE manual and training schedule are available at https://scale.ornl.gov. The primer provides specific examples of using SCALE/KENO-VI for criticality analysis; the SCALE/KENO-VI manual provides information on the use of SCALE/KENO-VI and all its modules. The primer also contains an appendix with sample input files. In addition, this primer, its errata, and sample inputs are also available at https://code.ornl.gov/scale/primers/kenovi/.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Frequent Fulcrum Functions: The Basics of SCALE’s Graphical User Interface [Slides]

This tutorial introduces the Fulcrum graphical user interface and the basic functions that enhance the common activities of creating, editing, navigating, executing, and visualizing SCALE input files. This tutorial will help you become familiar with the Fulcrum input file text editor and the integrated input development environment features of autocompletion, automatic checking, cursor context, and input navigation. In addition, the Fulcrum and SCALE runtime environment will be reviewed to improve the understanding of job execution workflow. This tutorial does not cover data and geometry plotting. Please see the Advanced User Interface Capabilities tutorial for details regarding plotting data and geometry. No prior experience with SCALE is required. You can follow along using SCALE 6.2 or 6.3-beta.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fulcrum Behavior Investigation

A summary of the issues that have come up in the use of the fulcrum radiation detector and the methods tools that I developed to deal with them.

Albiani, Nicolas B↗

Fulcrum House – Towards a Sustainable Composite Architecture

In the last decades, the accessibility to digital fabrication technologies positioned composites as an affordable, structurally efficient and low-maintenance alternative to traditional mineral-based and high-energy materials. Of special interest are carbon nanotubes (CNT) and carbon foam (CFoam) from methane and coal pyrolysis respectively, as an environmentally friendly substitute to glass and carbon fiber. This paper presents the design of a principled single-family house, as a first case study to identify the constraints of such a material system, including technology gap, techno-economic and life cycle assessment, as well as building code requirements. In turn, the investigation proposes a suitable design-to-fabrication workflow, which potentially could bring CNT and CFoam materials to the construction of buildings.

01 COAL, LIGNITE, AND PEAT↗

A strainmeter array as the fulcrum of novel observatory sites along the Alto Tiberina Near Fault Observatory

Fault slip is a complex natural phenomenon involving multiple spatiotemporal scales from seconds to days to weeks. To understand the physical and chemical processes responsible for the full fault slip spectrum, a multidisciplinary approach is highly recommended. The Near Fault Observatories (NFOs) aim at providing high-precision and spatiotemporally dense multidisciplinary near-fault data, enabling the generation of new original observations and innovative scientific products. The Alto Tiberina Near Fault Observatory is a permanent monitoring infrastructure established around the Alto Tiberina fault (ATF), a 60 km long low-angle normal fault (mean dip 20°), located along a sector of the Northern Apennines (central Italy) undergoing an extension at a rate of about 3 mm yr –1 . The presence of repeating earthquakes on the ATF and a steep gradient in crustal velocities measured across the ATF by GNSS stations suggest large and deep (5–12 km) portions of the ATF undergoing aseismic creep. Both laboratory and theoretical studies indicate that any given patch of a fault can creep, nucleate slow earthquakes, and host large earthquakes, as also documented in nature for certain ruptures (e.g., Iquique in 2014, Tōhoku in 2011, and Parkfield in 2004). Nonetheless, how a fault patch switches from one mode of slip to another, as well as the interaction between creep, slow slip, and regular earthquakes, is still poorly documented by near-field observation. With the strainmeter array along the Alto Tiberina fault system (STAR) project, we build a series of six geophysical observatory sites consisting of 80–160 m deep vertical boreholes instrumented with strainmeters and seismometers as well as meteorological and GNSS antennas and additional seismometers at the surface. By covering the portions of the ATF that exhibits repeated earthquakes at shallow depth (above 4 km) with these new observatory sites, we aim to collect unique open-access data to answer fundamental questions about the relationship between creep, slow slip, dynamic earthquake rupture, and tectonic faulting.

58 GEOSCIENCES↗

Advanced User Interface Capabilities [Slides]

This tutorial will review the data plotting and geometry visualization capabilities in the Fulcrum user interface. This tutorial will help you become familiar with Fulcrum’s 2D plot, and 2D and 3D geometry visualization features. You will learn how to identify plottable data items, compose and export plot and plot data for SCALE plot formats (SDF, Ampx MG/CE, PLT, F71, PTP, SPF, ORIGEN Gamma data, etc.) and visualize, navigate, cut, hide, and export the geometry and spatial data (fission-, dose-map, etc.) overlays in 2D and 3D. No prior experience with SCALE is required. Attendees can follow along using 6.3.0-beta.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Updated Primers Generated for SCALE 6.2 for KENO V.a and KENO-VI

Primers were developed and published for the use of the KENO V.a and KENO-VI codes in 2005 and 2008, respectively. These primers were both developed for SCALE 5 using the GeeWiz graphical user interface (GUI). Many new capabilities have been added to the transport codes since the release of these primers. The GUI was also changed to Fulcrum with the release of SCALE 6.2. For these reasons, updated versions of both primers were developed for a planned released in September 2020. The KENO V.a and KENO-VI codes are almost always run within the associated CSAS5 and CSAS6 sequences within SCALE, so the primers use the sequences and do not address running the codes in stand-alone mode.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Updated Primers Generated for SCALE 6.2 for KENO V.a and KENO-VI [Slides]

Primers were developed and published for the use of the KENO V.a and KENO-VI codes in 2005 and 2008, respectively. These primers were both developed for SCALE 5 using the GeeWiz graphical user interface (GUI). Many new capabilities have been added to the transport codes since the release of these primers. The GUI was also changed to Fulcrum with the release of SCALE 6.2. For these reasons, updated versions of both primers were developed for a planned released in September 2020. The KENO V.a and KENO-VI codes are almost always run within the associated CSAS5 and CSAS6 sequences within SCALE, so the primers use the sequences and do not address running the codes in stand-alone mode.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

VADER: A Tool for Criticality Safety Validation

The purpose of criticality safety is to prevent any inadvertent criticality from occurring during the handling or storage of fissile material. Calculations are frequently used to demonstrate that a sufficient subcritical margin exists. Validation is a key aspect of the evaluation process, establishing the suitability, accuracy, and associated uncertainty of the computational method and data to be used for the intended application. The validation process is performed by comparing the results of critical experiments with the calculated results from models of the experiments using the computational method to be validated. Laboratory critical experiments are controlled systems that achieve a k eff of approximately 1 in order to investigate the parameters at which such a critical condition is achieved. The validation parameters that are traditionally applied to safety analysis calculations are the bias and the bias uncertainty . The bias is the deviation of the average k eff of the validation suite from unity. The bias uncertainty accounts for the statistical uncertainty in the bias based on the standard deviation, sample size, and distribution of k eff values of the validation suite. The values of bias and bias uncertainty ensure that the systems predicted to be subcritical by the computational method will indeed be subcritical. The bias and bias uncertainty are often combined to determine an upper subcritical limit (USL) or computational margin that can then be applied to safety analysis calculations. Many methods have been developed by different organizations to calculate the bias and bias uncertainty for various types of criticality analyses. Each of these methods typically requires that the validity of various underpinning statistical assumptions be confirmed to demonstrate that the method is appropriate for the analysis of a given validation suite. An example of the validation decision making flow is shown in Fig.1. As shown in Fig. 1, the analyst performing the validation fits a trend line to the data and performs a test to determine if the trend was a statistically better representation of the data than if it were treated as an uncorrelated sample. If the trend line is a better representation of the data, then the analyst uses any one of a number of trending techniques to determine the bias and bias uncertainty. If a trend is not an appropriate representation of the data, then the analyst proceeds to perform a normality assessment for the data. If the normal assumption can be shown to be acceptable, then the analyst calculates the bias and bias uncertainty with the parametric technique. If the assumption of normality cannot be justified, then the nonparametric technique is used. Once the decision flow has been followed and the appropriate technique has been selected, the bias and bias uncertainty is typically combined with an administrative margin to determine a USL below which calculated values of k eff for safety analysis models can be considered subcritical. The calculations used in each decision are often performed with spreadsheets or with small programs available at various sites performing criticality analyses. Expertise in understanding and interpreting the results must be maintained to perform these calculations. This can often be an error-prone process. Oak Ridge National Laboratory (ORNL) is currently developing the Validation and Data Evaluation Resource (VADER) to simplify and automate the criticality safety validation process and to provide a software quality assurance pedigree to the calculational methods used. This paper discusses the use of the Fulcrum user interface with VADER, the anticipated initial capabilities of VADER to perform validation analyses, and the output from the code.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using the Criticality Accident Alarm System modeling capabilities in SCALE [Slides]

The following is a summary of advice for CAAS modeling in SCALE. Refer to the SCALE Criticality Safety and Radiation Shielding training slides or to the SCALE manual for exact syntax. Use a mesh for the fission source that is the most adequate for the problem to solve (coarse/fine). Don’t spend unnecessary resources; simplify the model if it does not impact the final results of interest. Be careful to deactivate secondary fissions in MAVRIC or the calculation may never end. Check that k eff and $\overline{\upsilon}$ calculated results are logical. Between KENO and MAVRIC, cross section libraries, materials, geometry, and mesh grid can be the same or different. Iterative calculations are usually complex problems that need variance reduction. It will be hard to find the best solving parameters in the first attempt; expert judgement is needed. Check each step separately. Use Fulcrum to visualize fission source, mesh source, and spatial/energy distributions to find potential errors or impactful imprecisions.