Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fulcrum”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

KENO V.a Primer: Performing Calculations using SCALE’s Criticality Safety Analysis Sequence (CSAS5) with Fulcrum

The SCALE code system developed at Oak Ridge National Laboratory is widely used and accepted around the world for criticality safety analyses. The well-known KENO V.a three-dimensional Monte Carlo criticality computer code is one of the primary criticality safety analysis tools in SCALE. The KENO V.a primer is designed to help a new user understand and use the SCALE/KENO V.a Monte Carlo code for nuclear criticality safety analyses. It assumes that the user has a college education in a technical field. There is no assumption of familiarity with Monte Carlo codes in general or with SCALE/KENO V.a in particular. The primer is designed to teach by example, with each example illustrating two or three features of SCALE/KENO V.a that are useful in criticality analyses. The primer is based on SCALE 6.2 and 6.3, which includes the Fulcrum graphical user interface (GUI). Each example uses Fulcrum to provide the framework for preparing input data and viewing output results. Starting with a Quickstart section, the primer gives an overview of the basic requirements for SCALE/KENO V.a input and allows the user to quickly run a simple criticality problem with SCALE/KENO V.a. The sections that follow Quickstart include a list of basic objectives at the beginning that identifies the goal of the section and the individual SCALE/KENO V.a features that are covered in detail in the sample problems in that section. Upon completion of the primer, a new user should be comfortable using Fulcrum to set up criticality problems in SCALE/KENO V.a. The primer provides a starting point for the criticality safety analyst who uses SCALE/KENO V.a. Complete descriptions are provided in the SCALE/KENO V.a manual. Although the primer is self-contained, it is intended as a companion volume to the SCALE/KENO V.a training and documentation. The SCALE manual and training schedule are available at https://scale.ornl.gov. The primer provides specific examples of using SCALE/KENO V.a for criticality analyses; the SCALE/KENO V.a manual provides information on the use of SCALE/KENO V.a and all its modules. The primer also contains an appendix with sample input files. In addition, this primer, its errata and sample inputs are also available at https://code.ornl.gov/scale/primers/kenova.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

KENO-VI Primer: Performing Calculations using SCALE’s Criticality Safety Analysis Sequence (CSAS6) with Fulcrum

The SCALE code system developed at Oak Ridge National Laboratory is widely used and accepted around the world for criticality safety analysis. The well-known KENO-VI three-dimensional Monte Carlo criticality computer code is one of the primary criticality safety analysis tools in SCALE. The KENO-VI primer is designed to help a new user understand and use the SCALE/KENO-VI Monte Carlo code for nuclear criticality safety analysis. It assumes that the user has a college education in a technical field. There is no assumption of familiarity with Monte Carlo codes in general or with SCALE/KENO-VI in particular. The primer is designed to teach by example, with each example illustrating two or three features of SCALE/KENO-VI that are useful in criticality analysis. The primer is based on SCALE 6.2 and 6.3, which includes the Fulcrum graphical user interface. Each example uses Fulcrum to provide the framework for preparing input data and viewing output results. Starting with a Quickstart section, the primer gives an overview of the basic requirements for SCALE/KENO-VI input and allows the user to quickly run a simple criticality problem with SCALE/KENO-VI. Each following section begins with a list of basic objectives identifying the goal of the section and the individual SCALE/KENO-VI features covered in detail in the section’s sample problems. Upon completion of the primer, a new user should be comfortable using Fulcrum to set up criticality problems in SCALE/KENO-VI. The primer provides a starting point for the criticality safety analyst who uses SCALE/KENO-VI. Complete descriptions are provided in the SCALE/KENO-VI manual. Although the primer is self-contained, it is intended as a companion volume to the SCALE/KENO-VI training and documentation. The SCALE manual and training schedule are available at https://scale.ornl.gov. The primer provides specific examples of using SCALE/KENO-VI for criticality analysis; the SCALE/KENO-VI manual provides information on the use of SCALE/KENO-VI and all its modules. The primer also contains an appendix with sample input files. In addition, this primer, its errata, and sample inputs are also available at https://code.ornl.gov/scale/primers/kenovi/.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Frequent Fulcrum Functions: The Basics of SCALE’s Graphical User Interface [Slides]

This tutorial introduces the Fulcrum graphical user interface and the basic functions that enhance the common activities of creating, editing, navigating, executing, and visualizing SCALE input files. This tutorial will help you become familiar with the Fulcrum input file text editor and the integrated input development environment features of autocompletion, automatic checking, cursor context, and input navigation. In addition, the Fulcrum and SCALE runtime environment will be reviewed to improve the understanding of job execution workflow. This tutorial does not cover data and geometry plotting. Please see the Advanced User Interface Capabilities tutorial for details regarding plotting data and geometry. No prior experience with SCALE is required. You can follow along using SCALE 6.2 or 6.3-beta.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fulcrum User Interface for Scale 6.2

SCALE 6.2 consolidated the multiple special-purpose graphical user interfaces (GUI) of SCALE 6.1 into a completely new and modern interface called Fulcrum. Fulcrum is a cross-platform GUI designed to create, edit, validate, and visualize SCALE input, output, and data. It is intended to be usable by both novice and experienced SCALE users with an unobtrusive design. This paper presents a summary of Fulcrum capabilities. Specifically, interactive input validation, context-aware auto-completion, navigation, interactive geome-try visualization with mesh results overlay, job execution, data plotting, and highly config-urable workspace layouts will be discussed.

97 MATHEMATICS AND COMPUTING↗

FULCRUM user interface for SCALE 6.2

SCALE 6.2 consolidated the multiple special-purpose graphical user interfaces (GUI) of SCALE 6.1 into a completely new and modern interface called FULCRUM. FULCRUM is a cross-platform GUI designed to create, edit, validate, and visualize SCALE input, output, and data. It is intended to be usable by both novice and experienced SCALE users with an unobtrusive design. This paper presents a summary of FULCRUM capabilities. Specifically, interactive input validation, context-aware auto-completion, navigation, interactive geometry visualization with mesh results overlay, job execution, data plotting, and highly configurable workspace layouts will be discussed. (authors)

97 MATHEMATICS AND COMPUTING↗

Fulcrum Behavior Investigation

A summary of the issues that have come up in the use of the fulcrum radiation detector and the methods tools that I developed to deal with them.

Albiani, Nicolas B↗

Fulcrum House – Towards a Sustainable Composite Architecture

In the last decades, the accessibility to digital fabrication technologies positioned composites as an affordable, structurally efficient and low-maintenance alternative to traditional mineral-based and high-energy materials. Of special interest are carbon nanotubes (CNT) and carbon foam (CFoam) from methane and coal pyrolysis respectively, as an environmentally friendly substitute to glass and carbon fiber. This paper presents the design of a principled single-family house, as a first case study to identify the constraints of such a material system, including technology gap, techno-economic and life cycle assessment, as well as building code requirements. In turn, the investigation proposes a suitable design-to-fabrication workflow, which potentially could bring CNT and CFoam materials to the construction of buildings.

01 COAL, LIGNITE, AND PEAT↗

A strainmeter array as the fulcrum of novel observatory sites along the Alto Tiberina Near Fault Observatory

Fault slip is a complex natural phenomenon involving multiple spatiotemporal scales from seconds to days to weeks. To understand the physical and chemical processes responsible for the full fault slip spectrum, a multidisciplinary approach is highly recommended. The Near Fault Observatories (NFOs) aim at providing high-precision and spatiotemporally dense multidisciplinary near-fault data, enabling the generation of new original observations and innovative scientific products. The Alto Tiberina Near Fault Observatory is a permanent monitoring infrastructure established around the Alto Tiberina fault (ATF), a 60 km long low-angle normal fault (mean dip 20°), located along a sector of the Northern Apennines (central Italy) undergoing an extension at a rate of about 3 mm yr –1 . The presence of repeating earthquakes on the ATF and a steep gradient in crustal velocities measured across the ATF by GNSS stations suggest large and deep (5–12 km) portions of the ATF undergoing aseismic creep. Both laboratory and theoretical studies indicate that any given patch of a fault can creep, nucleate slow earthquakes, and host large earthquakes, as also documented in nature for certain ruptures (e.g., Iquique in 2014, Tōhoku in 2011, and Parkfield in 2004). Nonetheless, how a fault patch switches from one mode of slip to another, as well as the interaction between creep, slow slip, and regular earthquakes, is still poorly documented by near-field observation. With the strainmeter array along the Alto Tiberina fault system (STAR) project, we build a series of six geophysical observatory sites consisting of 80–160 m deep vertical boreholes instrumented with strainmeters and seismometers as well as meteorological and GNSS antennas and additional seismometers at the surface. By covering the portions of the ATF that exhibits repeated earthquakes at shallow depth (above 4 km) with these new observatory sites, we aim to collect unique open-access data to answer fundamental questions about the relationship between creep, slow slip, dynamic earthquake rupture, and tectonic faulting.

58 GEOSCIENCES↗

Pressure vessel sliding support unit and system using the sliding support unit

Provided is a sliding support and a system using the sliding support unit. The sliding support unit may include a fulcrum capture configured to attach to a support flange, a fulcrum support configured to attach to the fulcrum capture, and a baseplate block configured to support the fulcrum support. The system using the sliding support unit may include a pressure vessel, a pedestal bracket, and a plurality of sliding support units.

42 ENGINEERING↗

A dual-view digital tomosynthesis imaging technique for improved chest imaging

Purpose: Digital tomosynthesis (DTS) has been shown to be useful for reducing the overlapping of abnormalities with anatomical structures at various depth levels along the posterior–anterior (PA) direction in chest radiography. However, DTS provides crude three-dimensional (3D) images that have poor resolution in the lateral view and can only be displayed with reasonable quality in the PA view. Furthermore, the spillover of high-contrast objects from off-fulcrum planes generates artifacts that may impede the diagnostic use of the DTS images. In this paper, the authors describe and demonstrate the use of a dual-view DTS technique to improve the accuracy of the reconstructed volume image data for more accurate rendition of the anatomy and slice images with improved resolution and reduced artifacts, thus allowing the 3D image data to be viewed in views other than the PA view. Methods: With the dual-view DTS technique, limited angle scans are performed and projection images are acquired in two orthogonal views: PA and lateral. The dual-view projection data are used together to reconstruct 3D images using the maximum likelihood expectation maximization iterative algorithm. In this study, projection images were simulated or experimentally acquired over 360° using the scanning geometry for cone beam computed tomography (CBCT). While all projections were used to reconstruct CBCT images, selected projections were extracted and used to reconstruct single- and dual-view DTS images for comparison with the CBCT images. For realistic demonstration and comparison, a digital chest phantom derived from clinical CT images was used for the simulation study. An anthropomorphic chest phantom was imaged for the experimental study. The resultant dual-view DTS images were visually compared with the single-view DTS images and CBCT images for the presence of image artifacts and accuracy of CT numbers and anatomy and quantitatively compared with root-mean-square-deviation (RMSD) values computed using the digital chest phantom or the CBCT images as the reference in the simulation and experimental study, respectively. High-contrast wires with vertical, oblique, and horizontal orientations in a PA view plane were also imaged to investigate the spatial resolutions and how the wire signals spread in the PA view and lateral view slice images. Results: Both the digital phantom images (simulated) and the anthropomorphic phantom images (experimentally generated) demonstrated that the dual-view DTS technique resulted in improved spatial resolution in the depth (PA) direction, more accurate representation of the anatomy, and significantly reduced artifacts. The RMSD values corroborate well with visual observations with substantially lower RMSD values measured for the dual-view DTS images as compared to those measured for the single-view DTS images. The imaging experiment with the high-contrast wires shows that while the vertical and oblique wires could be resolved in the lateral view in both single- and dual-view DTS images, the horizontal wire could only be resolved in the dual-view DTS images. This indicates that with single-view DTS, the wire signals spread liberally to off-fulcrum planes and generated wire shadow there. Conclusions: The authors have demonstrated both visually and quantitatively that the dual-view DTS technique can be used to achieve more accurate rendition of the anatomy and to obtain slice images with improved resolution and reduced artifacts as compared to the single-view DTS technique, thus allowing the 3D image data to be viewed in views other than the PA view. These advantages could make the dual-view DTS technique useful in situations where better separation of the objects-of-interest from the off-fulcrum structures or more accurate 3D rendition of the anatomy are required while a regular CT examination is undesirable due to radiation dose considerations.

60 APPLIED LIFE SCIENCES↗

Advanced User Interface Capabilities [Slides]

This tutorial will review the data plotting and geometry visualization capabilities in the Fulcrum user interface. This tutorial will help you become familiar with Fulcrum’s 2D plot, and 2D and 3D geometry visualization features. You will learn how to identify plottable data items, compose and export plot and plot data for SCALE plot formats (SDF, Ampx MG/CE, PLT, F71, PTP, SPF, ORIGEN Gamma data, etc.) and visualize, navigate, cut, hide, and export the geometry and spatial data (fission-, dose-map, etc.) overlays in 2D and 3D. No prior experience with SCALE is required. Attendees can follow along using 6.3.0-beta.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Flexure-based, tip-tilt-piston actuation micro-array

A flexure-based micro-array having a plurality of micro-assemblies, each comprising: an object; and at least three electrostatic actuation modules for tipping, tilting, and/or piston-actuating the object, each actuation module comprising: a base with first and second electrodes electrically isolated from each other; an electrically conductive lever arm; a first flexure bearing suspending the lever arm adjacent the first and second electrodes so that electrical activation of at least one of the first and second electrodes produces an electrostatic moment of force on the lever arm to resiliently bias the first flexure bearing and pivot the lever arm about a fulcrum; and a second flexure bearing connecting the lever arm to the object at a connection location that is different from other connection locations of the other actuation modules so that pivoting the lever arm about the fulcrum induces the second flexure bearing to pivot the object about an object pivot axis defined between two of the other connection locations while the second flexure bearing decouples the lever arm from object displacements induced by two of the other actuation modules connected to the two other connection locations defining the object pivot axis, wherein the plurality of micro-assemblies are arranged with the objects juxtaposed in a substantially 2D array.

42 ENGINEERING↗

Updated Primers Generated for SCALE 6.2 for KENO V.a and KENO-VI

Primers were developed and published for the use of the KENO V.a and KENO-VI codes in 2005 and 2008, respectively. These primers were both developed for SCALE 5 using the GeeWiz graphical user interface (GUI). Many new capabilities have been added to the transport codes since the release of these primers. The GUI was also changed to Fulcrum with the release of SCALE 6.2. For these reasons, updated versions of both primers were developed for a planned released in September 2020. The KENO V.a and KENO-VI codes are almost always run within the associated CSAS5 and CSAS6 sequences within SCALE, so the primers use the sequences and do not address running the codes in stand-alone mode.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Updated Primers Generated for SCALE 6.2 for KENO V.a and KENO-VI [Slides]

Primers were developed and published for the use of the KENO V.a and KENO-VI codes in 2005 and 2008, respectively. These primers were both developed for SCALE 5 using the GeeWiz graphical user interface (GUI). Many new capabilities have been added to the transport codes since the release of these primers. The GUI was also changed to Fulcrum with the release of SCALE 6.2. For these reasons, updated versions of both primers were developed for a planned released in September 2020. The KENO V.a and KENO-VI codes are almost always run within the associated CSAS5 and CSAS6 sequences within SCALE, so the primers use the sequences and do not address running the codes in stand-alone mode.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SCALE Newsletter (Number 52, Spring 2020)

SCALE Newsletter is published by the Reactor and Nuclear Systems Division of the Oak Ridge National Laboratory. This issue, number 52 from Spring of 2020, holds information about the current state, planned updates, and previews of the SCALE system designed and maintained by ORNL staff. This issue contains employee spotlights for Dr. Kursat Bekar as well as Dr. Andrew M. Holcomb and displays data and charts from new/updated features of SCALE such as new data libraries, Fulcrum 3D visualizations, and interactions with ENDF/B-VIII.0 data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A new ATLAS muon CSC readout system with system on chip technology on ATCA platform

The ATLAS muon Cathode Strip Chamber (CSC) back-end readout system has been upgraded during the LHC 2013-2015 shutdown to be able to handle the higher Level-1 trigger rate of 100 kHz and the higher occupancy at Run 2 luminosity. The readout design is based on the Reconfiguration Cluster Element (RCE) concept for high bandwidth generic DAQ implemented on the ATCA platform. The RCE design is based on the new System on Chip Xilinx Zynq series with a processor-centric architecture with ARM processor embedded in FPGA fabric and high speed I/O resources together with auxiliary memories to form a versatile DAQ building block that can host applications tapping into both software and firmware resources. The Cluster on Board (COB) ATCA carrier hosts RCE mezzanines and an embedded Fulcrum network switch to form an online DAQ processing cluster. More compact firmware solutions on the Zynq for G-link, S-link and TTC allowed the full system of 320 G-links from the 32 chambers to be processed by 6 COBs in one ATCA shelf through software waveform feature extraction to output 32 S-links. Furthermore, the full system was installed in Sept. 2014. We will present the RCE/COB design concept, the firmware and software processing architecture, and the experience from the intense commissioning towards LHC Run 2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗