Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA+”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Verification and Validation Tests of Gamma Library of MC2-3 for Coupled Neutron and Gamma Heating Calculation

For the accurate assessment of the heat generation rate in fast reactors, the gamma library of MC2 -3 and the MC2 -3 + GAMSOR procedure employing the coupled neutron and gamma heating calculation has been thoroughly verified against Monte Carlo results and validated using the ZPPR-15D gamma dose measurement data. NJOY outputs are post-processed in a consistent way with the NJOY procedure to avoid any missing data or double counting of data. Prompt heating for 379 out of 391 isotopes in the gamma library was verified against MCNP6.2 to within 1% relative error in total heating for most isotopes. For both a simple one-dimensional slab problem representing a sodium cooled fast reactor and the Experimental Breeder Reactor II (EBR-II) benchmark problem, the root-mean-square values of assembly power error were less than 0.5% for fuel assemblies, ~1% in blankets and ~1 to ~3% in reflectors compared to MCNP6.2 results. The most plausible cause for the 3% error in a reflector assembly is believed to be the error in the multigroup neutron cross sections for the reflector assembly. For validation, gamma doses measured with thermoluminiscent dosimeters (TLDs) in the ZPPR-15D experiment were calculated using GAMSOR. Due to the uncertainty in the TLD measurement with regards to the energy deposition of photons and neutrons, the validation data leads to a 12.7% uncertainty on the experimental measurement. With this uncertainty bound, the calculated doses all fell within one standard deviation of the measured value. Combined with the accurate calculation of reaction rate distributions and neutron spectrum measurements, these results indicate good agreement for the neutron and gamma heating calculations that were performed.

coupled neutron and gamma heating↗

Primary $\gamma$-ray intensities and $\gamma$-strength functions from discrete two-step $\gamma$-ray cascades in radiative proton-capture experiments

Background: Reaction rates of radiative capture reactions can play a crucial role in the nucleosynthesis of heavy nuclei in explosive stellar environments. These reaction rates depend strongly on $\gamma$-ray decay widths in the reaction products, which are, for nonresonant capture reactions at high excitation energies, derived from the $\gamma$-ray strength function and the nuclear level density. Recently, the ratio method was applied to primary $\gamma$ rays observed from ($\textit{d, p}$) reactions and nuclear resonance fluorescence measurements to extract the dipole strength in atomic nuclei and to test the generalized Brink-Axel hypothesis. Purpose: The purpose of this work is to apply the ratio method to primary $\gamma$-ray intensities of the 63,65 Cu($\textit{p},\gamma$) reactions to extract $\gamma$-ray strength information on the nuclei 64,66 Zn. Here, the impact of spin distribution, total $\gamma$-ray decay widths, level densities, and width fluctuations on the application of the ratio method will be discussed. Additionally, by comparing the relative $\gamma$-ray strength at different excitation energies, conclusions on the validity of the generalized Brink-Axel hypothesis can be made. Method: The radiative proton capture reaction measurements have been performed at the HORUS $\gamma$-ray spectrometer of the University of Cologne at one excitation energy for each reaction. Primary $\gamma$-ray intensities have been determined by normalizing secondary $\gamma$-ray transitions in two-step cascades using their absolute branching ratio. The ratio method was applied to the measured primary $\gamma$-ray intensities as well as to previous measurements by Erlandsson et al. at different excitation energies. Results: The relative strength function curve for 64 Zn from our measurement shows no significant deviation from the previous measurement at a different excitation energy. The same is true for 66 Zn where both measurements were at almost the same excitation energy. Absolute $\gamma$-strength function values have been obtained by normalizing the relative curves to quasiparticle random phase approximation calculations because of the absence of experimental data in the respective energy region. Conclusion: The generalized Brink-Axel hypothesis, i.e., the independence of the strength function on the excitation energy, seems to hold in the studied energy region and nuclei. The method to obtain primary $\gamma$-ray intensities from two-step cascade spectra was shown to be a valuable and sensitive tool although its uncertainties are connected to the knowledge of the low-energy level scheme of the investigated nucleus. The scaling in the ratio method should be taken with care, because the relative strength is not a simple sum of $f_{E1}$ and $f_{M1}$ but a somewhat complex linear combination dependent on the excitation energy of the nucleus.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Searches for exclusive Higgs boson decays into D *$\gamma$ and Z boson decays into D 0 $\gamma$ and K $^{0}_{s}$$\gamma$ in pp collisions at $\sqrt{s}$ = 13 TeV with the ATLAS detector

Searches for exclusive decays of the Higgs boson into D*$\gamma$ and of the Z boson into D 0 $\gamma$ and K$_{s}^{0}$$\gamma$ can probe flavour-violating Higgs boson and Z boson couplings to light quarks. Searches for these decays are performed with a pp collision data sample corresponding to an integrated luminosity of 136.3 fb -1 collected at $\sqrt{s}$ = 13TeV between 2016–2018 with the ATLAS detector at the CERN Large Hadron Collider. In the D*$\gamma$ and D 0 $\gamma$ channels, the observed (expected) 95% confidence-level upper limits on the respective branching fractions are B(H→D*$\gamma$) < 1.0(1.2)×10 -3 , B(Z→D 0 $\gamma$) < 4.0(3.4)×10 -6 , while the corresponding results in the K$_{s}^{0}$$\gamma$ channel are B(Z→K$_{s}^{0}$$\gamma$) < 3.1(3.0)×10 -6 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Preliminary Investigation for the Use of Digital Gamma-Gamma Coincidence Spectrometry to Determine 239 Pu

Gamma-ray spectrometry is one of the most effective ways to determine the activity of 239 Pu, depending on activity levels. However, often high backgrounds in complex spectra with low amounts of 239 Pu can increase detection limits. The effectiveness of the use of gamma-gamma spectrometry in the characterization of 239 Pu was studied for the first time. Using the XIA Pixie-16 digital pulse processor, the gamma-gamma system was studied to establish unshielded background radiation, source to detector distances, Poisson statistics and gating of several gamma-rays from 239 Pu. The results clearly show that the distance between gamma ray spectrometers has a much bigger effort in counting statistics for the gamma-gamma coincidence detectors than a single detector. In addition, measurements demonstrated the background radiation to be virtually negligible, meaning gammagamma spectroscopy can still be very effective without requiring the usual lead shielding. Other measurements were taken to assure Poisson statistics were attained in the digital system. Preliminary measurements revealed 3 orders of magnitude background reduction for the measurement of 239 Pu using gated gamma-rays.

61 RADIATION PROTECTION AND DOSIMETRY↗

Testing of an Optical Fiber--Based Gamma Thermometer in the High Flux Isotope Reactor Gamma Irradiation Facility

This report describes the design, thermal modeling, and gamma irradiation testing of an optical fiber–based gamma thermometer (OFBGT), which was irradiated in the High Flux Isotope Reactor (HFIR) Gamma Irradiation Facility (GIF). OFBGTs are a promising technology for application in nuclear reactors because they can provide a distributed measurement of gamma ray heating rate, unlike thermocouple-based gamma thermometers, which are fixed in-core sensors that can be used in boiling water reactors to calibrate local power range monitors. OFBGTs measure gamma ray heating rate by measuring the temperature difference between a pair of optical fibers; one fiber is in thermal contact with a heat sink (usually the reactor coolant), and the other is in thermal contact with a thermally isolated mass. The device can be calibrated with a heating wire within the thermal mass. The OFBGT that was designed and fabricated at Oak Ridge National Laboratory can measure distributed gamma ray heating rate over an effective measurement length of 61 cm, and the outer diameter of the sensor is 12.7 mm, giving the prototypical sensor design a relatively small footprint. The sensor housing is backfilled with Ar to ensure a well-predicted thermal response that is not affected by humidity or chemical interactions during operation. For calibration, the sensor design uses a Ni–Cr wire, which can be supplied with currents from 0 to 1 A to capture the wide range of potential gamma ray heating rates expected in HFIR’s spent fuel elements. The OFBGT was thermally modeled analytically and numerically; both models account for temperature-dependent thermal conductivities of the materials and show good agreement. The thermal response of the sensor inside spent HFIR fuel elements was simulated for times up to 1 year after discharge of the fuel element. Out-of-pile open-air tests indicated that the steady-state response of the sensor matches modeled results within experimental uncertainty. Calibration tests were performed using electrical heating in the HFIR spent fuel pool, above the fuel elements, to establish a relationship between the difference in spectral shift measured by optical fibers located inside and outside the OFBGT and the applied electrical heating. Subsequently, the OFBGT was placed within the the spent fuel element from HFIR cycle 501 to measure the spatial profile of the gamma heating rates. Results showed good agreement between the theoretical and measured gamma dose rate profiles, with maximum deviations of ~10% or less.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fermi-LAT Captures a Late-2024 Gamma-Ray Outburst near Two Newly Identified Gamma-Ray-emitting Galactic Supernova Remnants, without Evidence of Physical Association

We report the gamma-ray study of two neighboring in the sky Galactic supernova remnants (SNRs), namely, 3C 434.1 (or G094.0+01.0) and G093.7–00.2. In the vicinity of the two SNRs, a late-2024 gamma-ray outburst—not physically connected to the SNRs—was detected with the Fermi Large Area Telescope (LAT). Employing 16.5 yr of Fermi-LAT data, we report the first firm detection of the gamma-ray counterpart of 3C 434.1 at a 7.2σ significance and a likely detection of an enhanced gamma-ray emission signal at a 4.5σ level from G093.7–00.2. The late-2024 gamma-ray outburst is detected at a ∼12σ significance level over a duration of 3 days. For all three objects, a comprehensive morphological and spectral analysis of the corresponding gamma-ray data was conducted. The prevalent scenario for the nature of the gamma-ray emission of both SNRs is attributed to their surrounding environment. Both are likely interacting with nearby dense material, resulting in hadronically induced gamma-ray emission. We deduce that the outburst source is most likely a blazar in flare, linked to the compact, flat-spectrum radio source TXS 2138+527 (also known as NVSS J213953+530016). Further, the spectral analysis of the gamma-ray source conducted within the 100 MeV–800 GeV energy range using the complete LAT data sets, which yielded a soft averaged spectral shape, supports the hypothesis of a flat spectrum radio quasar (FSRQ) origin for the source; with a most likely leptonically induced scenario for the observed gamma-ray outburst as inferred from the obtained hard spectral shape when utilizing short time intervals focusing on the outburst.

Michailidis, Miltiadis [Stanford Univ., CA (United↗

Neutron activation analysis using gamma-gamma coincidence to eliminate spectral interferences

The use of neutron activation analysis (NAA) sometimes has limitations with the identification of specific gamma ray peaks due to spectral interferences. The implementation of gamma-gamma coincidence techniques using the XIA Pixie-16 system has demonstrated the ability reduce many of these challenges. In this work, experiments were performed on two different NIST reference materials using gamma-gamma coincidence techniques to identify long-lived radionuclides that are often difficult to evaluate due to various spectral interferences. The experiments have shown that utilizing gamma-gamma coincidence with the XIA Pixie-16 system for 177m Lu, 124 Sb, 160 Tb, 175 Yb, and 153 Sm can eliminate spectral interferences and high backgrounds due to Compton scattering.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of Gamma Background Radiation Digital Twin with Machine Learning Algorithms: Application of Unsupervised Machine Learning to Detection of Anomalies and Nuisances in Gamma Background Radiation Environmental Screening Data

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to explore unsupervised machine learning (ML) algorithms for development of a digital twin of gamma radiation background, and for detection and identification of weak nuisances and anomalies events in the presence of highly fluctuating background. In one segment of work, we developed a gamma background estimation model using a Longshort term memory (LSTM) network for one-step CPS time series prediction. The LSTM model was validated with two data sets of measurements from two independent NaI detectors positioned on a mobile platform. The data sets contained background radiation only and no orphan isotope sources. The LSTM model was constructed and tested using data from one of the detectors. Performance of the LSTM model was validate through one-step prediction of CPS time series of another NaI detector without re-training. This approach allows to create a digital twin for nuclear background estimation. Using LSTM, it could be possible to detect a source through subtraction of the estimated counts from the measured background. In another segment of work, we investigated detection of gamma emitting sources in the presence of complex background using unsupervised machine learning. Spectral lines of isotopes are difficult to observe in one-second measurements. Averaging over the entire measurement campaign data set reveals spectral lines of most common background isotopes. Spectral lines of orphan sources, which might appear only in a few measurements during the campaign, will be washed out if averaging is performed over the entire measurement data set. The approach we have explored consists of extracting one-second measurements containing weak spectral features through data clustering. Averaging one-second spectra in a cluster should reveal the presence of anomaly sources. We created two ML models using K-means clustering and Neural Network Self-organizing Map (SOM). Performance of these ML models was benchmarked using search data. One data set contained 137 Cs source, and another dataset contained 131 I source.

54 ENVIRONMENTAL SCIENCES↗

Search for the rare decays $W^+ → D^+_s \gamma$ and $Z → D^0 \gamma$ at LHCb

A search for the rare decays $W^+ → D^+_s \gamma$ and $Z → D^0 \gamma$ is performed using proton-proton collision data collected by the LHCb experiment at a centre-of-mass energy of 13TeV, corresponding to an integrated luminosity of 2.0fb -1 . No significant signal is observed for either decay mode and upper limits on their branching fractions are set using W⁺ → μ⁺v and Z → μ⁺μ⁻ decays as normalization channels. The upper limits are 6.5 x 10 -4 and 2.1 x 10 -3 at 95% confidence level for the $W^+ → D^+_s \gamma$ and $Z → D^0 \gamma$ decay modes, respectively. This is the first reported search for the $Z → D^0 \gamma$ decay, while the upper limit on the branching fraction $W^+ → D^+_s \gamma$ improves upon the previous best limit.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Energy & High Luminosity $\gamma \gamma$ Colliders

With the best of modern standard lasers, high-energy $\gamma\gamma$ colliders from electron beams of E larger than 250 GeV are possible at the expense of photon luminosity, i.e. 10 times lower than for photon colliders at c.m. energies below 0.5 TeV. This Snowmass21 Contributed Paper shows how Free Electron Lasers (FEL) pave the way for High Energy & High Luminosity $\gamma\gamma$ colliders. We present and assess a conceptual design study of the Free Electron Laser that would be required for high luminosity $\gamma\gamma$ colliders as second interaction region of 0.5 TeV to 10 TeV c.m. $e^+e^-$ colliders.

43 PARTICLE ACCELERATORS↗

Update of the Nuclear Criticality Slide Rule Calculations: Plutonium systems – Delayed Fission Gamma

IRSN (France), LLNL (USA) and ORNL (USA) began a long-term collaboration effort in 2015 to update the nuclear criticality Slide Rule for the emergency response to a nuclear criticality accident. The Slide Rule permits the estimation of neutron and gamma dose rates and integrated doses based upon estimated fission yields, as a function of distance from the fission source, and time after criticality accidents for different critical systems. This paper presents results from the fourth phase of the current update of the Slide Rule project, in which delayed fission-product gamma (DFG) dose rates of unreflected plutonium critical systems were compared by several modern 3D radiation transport codes (MCNP, COG, SCALE), using updated flux-to-dose conversion factors. Dose rates are calculated for fissile material at five moderation ratios (H/Pu), at 1 m above the ground as a function of distance (between 30 cm and 1,200 m) from the external surface of the source to the center of the detector, and for periods between 1 s and 1,000 min after the critical instantaneous event. Further efforts have been devoted to the determination of the delayed gamma source, by comparing the time-dependent energy spectra obtained from several methods. Overall, DFG dose rates calculated by each participant led to consistent results. Extra effort is under way to identify the cause of the remaining differences, by comparing precisely the gamma source, and particularly nuclides inventories.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Identification and Suppression of Point Defects in Bromide Perovskite Single Crystals Enabling Gamma‐Ray Spectroscopy

Abstract Methylammonium lead tribromide (MAPbBr 3 ) stands out as the most easily grown wide‐band‐gap metal halide perovskite. It is a promising semiconductor for room‐temperature gamma‐ray ( γ ‐ray) spectroscopic detectors, but no operational devices are realized. This can be largely attributed to a lack of understanding of point defects and their influence on detector performance. Here, through a combination of crystal growth design and defect characterization, including positron annihilation and impedance spectroscopy, the presence of specific point defects are identified and correlated to detector performance. Methylammonium (MA) vacancies, MA interstitials, and Pb vacancies are identified as the dominant charge‐trapping defects in MAPbBr 3 crystals, while Br vacancies caused doping. The addition of excess MABr reduces the MA and Br defects and so enables the detection of energy‐resolved γ ‐ray spectra using a MAPbBr 3 single‐crystal device. Interestingly, the addition of formamidinium (FA) cations, which converted to methylformamidinium (MFA) cations by reaction with MA + during crystal growth further reduced MA defects. This enabled an energy resolution of 3.9% for the 662 keV 137 Cs line using a low bias of 100 V. The work provides direction toward enabling further improvements in wide‐bandgap perovskite‐based device performance by reducing detrimental defects.

Ni, Zhenyi↗

Performance testing of a Compton suppressed coincidence measurements using the Advanced Radionuclide Gamma-spectrOmeter

A Compton-suppressed multidimensional gamma-spectrometer is being developed within the Shallow Underground Laboratory (SUL) at Pacific Northwest National Laboratory (PNNL, USA). This Advanced Radionuclide Gamma-spectrOmeter (ARGO) system consists of two Broad Energy Germanium (BEGe) detectors, surrounded by a 12-detector sodium iodide (NaI) Compton suppression shield, situated inside a low-background lead and copper shield, fitted with a cosmic veto background reduction system. The detector has advanced functionality, including operation in single or combined detector mode, coincidence mode and Compton suppressed coincidence mode. Validation experiments measuring a neutron irradiated natural uranium sample, have demonstrated order of magnitude improvements in gamma detection sensitivity compared to conventional gamma-spectrometry techniques. Importantly this research demonstrates the feasibility of processing and analysing high-multiplicity datasets and the potential for high-sensitivity radionuclide measurements.

ARGO↗

Measurement of $Z\gamma \gamma$ production in pp collisions at $\sqrt{s}= 13$ TeV with the ATLAS detector

Cross-sections for the production of a $Z$ boson in association with two photons are measured in proton–proton collisions at a centre-of-mass energy of 13 TeV. The data used correspond to an integrated luminosity of 139 fb -1 recorded by the ATLAS experiment during Run 2 of the LHC. The measurements use the electron and muon decay channels of the $Z$ boson, and a fiducial phase-space region where the photons are not radiated from the leptons. The integrated $Z$($\rightarrow$ $\ell$$\ell$)$\gamma \gamma$ cross-section is measured with a precision of 12% and differential cross-sections are measured as a function of six kinematic variables of the $Z\gamma \gamma$ system. The data are compared with predictions from MC event generators which are accurate to up to next-to-leading order in QCD. The cross-section measurements are used to set limits on the coupling strengths of dimension-8 operators in the framework of an effective field theory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Specification of EBR-II Gamma Scan Data from the Precision Gamma Scanner

The gamma scan data stored in the FIPD was originally measured using the Precision Gamma Scanner (PGS) at the Hot Fuel Examination Facility (HFEF) at Idaho National Laboratory (INL). This system was originally manufactured in 1971 (when the facilities, now at INL, were operated by Argonne National Laboratory) and was upgraded on several occasions. It consists of a germanium gamma ray detector (the exact nature of which changed over time as technology improved), a variable-slit collimator that blocks the view of gamma emissions from all but the selected area of the target, and a computer-controlled system for translating a sample past the slit and logging the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-Rays from Kilonovae and the Cosmic Gamma-Ray Background

The recent detection of the gravitational-wave event GW170817, produced by the coalescence of two neutron stars, and of its optical–infrared counterpart, powered by the radioactive decay of r-process elements, has opened a new window onto gamma-ray astronomy: the direct detection of photons coming from such decays. In this work, we calculate the contribution of kilonovae to the diffuse gamma-ray background in the MeV range, using recent results on the spectra of the gamma-rays emitted in individual events, and we compare it with that from other sources. We find that the contribution from kilonovae is not dominant in such an energy range, but within current uncertainties, and its addition to other sources might help to fit the observational data.

59 BASIC BIOLOGICAL SCIENCES↗