Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA RAY BEAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Evaluation of a deuterated detector for gamma-ray beam intensity measurements

Laser-Compton scattering sources of quasi-monochromatic γ-ray beams have been in operation for over 30 years, with new facilities being under construction or proposed. To sustain a high-quality experimental physics program, continuous monitoring of these beams is essential by measuring the spectral, temporal, and spatial characteristics. In this work, we introduce a new method for determining the γ-ray beam intensity by using photodisintegration of deuterons in an active target detector approach. Measurements were performed using deuterated liquid scintillator detectors at several incident gamma energies between 4 and 13 MeV at the High Intensity γ-ray Source, Durham, USA. The results demonstrate that an instrument based on a deuterated active detector can be used to monitor the intensity of the γ-ray beam with high efficiency and operational simplicity.

Compton scattering↗

Precision measurements on oxygen formation in stellar helium burning with gamma-ray beams and a Time Projection Chamber

The carbon/oxygen (C/O) ratio at the end of stellar helium burning is the single most important nuclear input to stellar evolution theory. However, it is not known with sufficient accuracy, due to large uncertainties in the cross-section for the fusion of helium with 12 C to form 16 O, denoted as 12 C( α , γ ) 16 O. Here we present results based on a method that is significantly different from the experimental efforts of the past four decades. With data measured inside one detector and with vanishingly small background, angular distributions of the 12 C( α , γ ) 16 O reaction were obtained by measuring the inverse 16 O( γ , α ) 12 C reaction with gamma-beams and a Time Projection Chamber (TPC) detector. We agree with current world data for the total reaction cross-section and further evidence the strength of our method with accurate angular distributions measured over the 1 - resonance at E cm ~2.4 MeV. Our technique promises to yield results that will surpass the quality of the currently available data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

In-beam $$\gamma $$-ray spectroscopy of $$^{94}$$Ag

Abstract A recoil-beta-tagging experiment has been performed to study the excited $$T=0$$ T = 0 and $$T=1$$ T = 1 states in the odd–odd $$N=Z$$ N = Z nucleus $$^{94}$$ 94 Ag, populated via the $$^{40}$$ 40 Ca( $$^{58}$$ 58 Ni,1p3n) $$^{94}$$ 94 Ag reaction. The experiment was conducted using the MARA recoil separator and JUROGAM3 array at the Accelerator Laboratory of the University of Jyväskylä. Through correlating fast, high-energy beta decays at the MARA focal plane with prompt $$\gamma $$ γ rays emitted at the reaction target, a number of transitions between excited states in $$^{94}$$ 94 Ag have been identified. The timing characteristics of these transitions confirm that they fall within decay sequences that feed the short-lived $$T=1$$ T = 1 ground state of $$^{94}$$ 94 Ag. The transitions are proposed to proceed within and between the sets of states with $$T=0$$ T = 0 and $$T=1$$ T = 1 . Possible correspondence between some of these transitions from analog states in $$^{94}$$ 94 Pd has been discussed, and shell-model calculations including multipole and monopole electromagnetic effects have been presented, in order to enable predictions of the decay patterns between the $$T=0$$ T = 0 and $$T=1$$ T = 1 states and to allow a theoretical set of Coulomb energy differences to be calculated for the $$A = 94$$ A = 94 $$T=1$$ T = 1 analog states.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of gamma-induced reactions between 10 and 19 MeV on natural zinc with potential application to 67 Cu production

As part of a broader campaign to understand gamma-induced charged particle emission with multiple materials, the cross sections of the (γ, p), and (γ, α) reactions on a natural zinc target were measured. Here, these cross sections were measured experimentally using a kinematically-complete, event-by-event methodology, using monoenergetic gamma ray beams from the High Intensity Gamma Source (HIγS) facility, ranging from 10 to 19 MeV, to bombard a natural metallic zinc target in vacuum. The measured cross sections are compared with theoretical predictions using the statistical model approach, which is important for the use of such models in real-world applications such as the production of the 67 Cu theranostic via the 68 Zn(γ, p) reaction.

Gamma-induced reactions↗

Effects of X-Rays, Electron Beam, and Gamma Irradiation on Chemical and Physical Properties of EVA Multilayer Films

Gamma-ray irradiation, using the cobalt-60 isotope, is the most common radiation modality used for medical device and biopharmaceutical products sterilization. Although X-ray and electron-beam (e-beam) sterilization technologies are mature and have been in use for decades, impediments remain to switching to these sterilization modalities because of lack of data on the resulting radiation effects for the associated polymers, as well as a lack of education for manufacturers and regulators on the viability of these sterilization alternatives. For this study, the compatibility of ethylene vinyl acetate (EVA) multilayer films with different ionizing radiation sterilization (X-ray, e-beam, and gamma irradiation) is determined by measuring chemical and physical film properties using high performance liquid chromatography, differential scanning calorimetry, Fourier-Transform InfraRed spectroscopy (FTIR), surface energy measurement, and electron spin resonance techniques. The results indicate that the three irradiation modalities induce no differences in thermal properties in the investigated dose range. Gamma and X-Ray irradiations generate the same level of reactive species in the EVA multilayer film, whereas e-beam generates a reduced quantity of reactive species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-ray and γ-ray beam interstellar communication and implications for SETI

The possibility of detecting artificial signals transmitted by alien civilizations via collimated X-ray or gamma-ray beams is investigated. The prospect of using such beams for human communication within the solar system and beyond is also discussed. Detector responses were simulated for input signals and analyzed using relative entropy. For simplicity, all signals were assumed to use on-off keying (OOK) modulation. “Real” signals were generated by taking digital files and sequentially feeding their raw binary data to the detector simulator, the resulting normalized information content of the detector signals was plotted and compared to random noise signals. Since jpeg files contain compressed information, these served as a proxy for artificial alien signals. This showed that there is a clear difference in measured information content between natural and artificial signals, even with relatively poor time resolution in the detector causing the signals to be smeared (dead-time/rise-time intervals many times longer than the duration between signal pulses). It was found that so long as the signal lasts for at least several rise-time/dead-time intervals, the distinction between random and artificial signals is obvious. A space-telescope with high time resolution for searching for such signals is briefly described and its basic requirements are outlined.

43 PARTICLE ACCELERATORS↗

Comparison of effects from gamma, e-beam and X-ray radiation on multilayer polymer films used in biopharmaceutical devices by chemometric treatment of spectroscopic data

The present study investigated the effects of gamma-ray, electron beam, and X-ray radiation on polymers in EVA/EVOH/EVA multilayer films. Spectroscopic methods, including FTIR and UV–Vis, were employed in conjunction with chemometric treatments such as PCA, SIMPLISMA treatments, and PLS models. The feasibility of dose prediction on multilayer film, given a known dose, is attainable across various irradiation technologies. Both gamma ray and X-ray exhibit comparable effects on the multilayer film, and it is feasible to anticipate the dose released on the film by utilizing UV–Vis spectra or infrared spectra for gamma ray or X-ray of a predetermined dose.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam↗

ORBITAL ANGULAR MOMENTUM BEAMS RESEARCH USING A FREE-ELECTRON LASER OSCILLATOR

Orbital angular momentum (OAM) photon beams are excellent tools for non-contact optical manipulation of mat- ter in a broad photon energy range. A free-electron laser (FEL) oscillator is well-suited for studying OAM beams with various features including a wide spectral coverage, wavelength tunability, two-color lasing, polarization control, etc. Here, we report the first experimental demonstration of superposed OAM beams from an oscillator FEL. Lasing at around 458 nm, we have generated superposed OAM beams up to the fourth order as a superposition of two pure OAM modes with opposite helicities. These generated beams have a good beam quality, a high degree of circular polarization, and high power. Using external rf modulation with frequen- cies from 1 to 30 Hz, we also developed a pulsed mode operation of the OAM beams with a highly reproducible temporal structure. FEL operation showcased in this work can be extended to higher photon energies, e.g. using a future x-ray FEL oscillator. The operation of such an OAM FEL also paves the way for the generation of OAM gamma-ray beams via Compton scattering.

Liu, P.↗

Generation of superposed orbital angular momentum beams using a free-electron laser oscillator

With wavelength tunability, free-electron lasers (FELs) are well-suited for generating orbital angular momentum (OAM) beams in a wide photon energy range. We report here the first experimental demonstration of OAM beam generation using an oscillator FEL with the tens of picosecond pulse duration. Lasing around 458 nm, we have produced the four lowest orders of superposed Laguerre-Gaussian beams using a very long FEL resonator of 53.73 m. The produced beams have good beam quality, excellent stability, and substantial average power. We have also developed a pulsed operation mode for these beams with a highly reproducible temporal structure for a range of repetition rate of 1–30 Hz. This development can be extended to short wavelengths, for example to x-rays using a future x-ray FEL oscillator. The OAM operation of such a storage-ring FEL also paves the way for the generation of OAM gamma-ray beams via inverse Compton scattering.

47 OTHER INSTRUMENTATION↗

Neutron heating assessment in Minerve reactor by using alanine/ESR dosimetry

In the framework of the ICERR (International Center based on Research Reactors) project, the effect of neutron/gamma irradiation on material and dosimeters has been studied. In this work, we explore the alanine dose-response in the core of the MINERVE research reactor at the CEA Cadarache and we investigate the neutron heating effects in order to evaluate alanine neutron sensitivity. The measured dose of the alanine detector in the mixed gamma-neutron field was estimated by electron spin resonance spectrometry (ESR) with reference to an absorbed dose in water from a 60 Co gamma-ray beam. The experimental sources of uncertainties were reduced by using the optimum conditions of charged-particle equilibrium (CPE), obtained by introducing alanine dosimeters into the aluminum pillbox. Cavity correction factors and dose components were evaluated by the Monte Carlo code MCNP. The calculation showed an underestimated neutron dose with a (C/E) value of about 0.993 +/- 10.83%(k = 1). Results indicate that the fast neutron dose, mainly due to elastic neutron scattering on hydrogen nuclei, represents about 70% of the total dose, while the gamma dose was found to be around 45% of the neutron dose. Additionally, the neutron relative efficiency (REn) to 60 Co gamma-radiation was estimated to be 0.544 +/- 8%(k = 1).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Fission with Exotic Nuclei (Abbreviated Report)

Nuclear fission is a key mechanism involved in the synthesis of heavy elements in the Cosmos and is the primary explanation for the stability of superheavy elements. Nevertheless, our knowledge of fission remains extremely fragmented. Most experiments have been conducted only on a tiny number of stable actinide nuclei and are often incomplete, leading to gaps in our basic understanding of the process. For many radioactive isotopes, basic fission data such as the charge or mass distribution of the fragments is unknown. These gaps cannot always be filled by simulation alone. Common fission models contain too many free parameters and lack predictive power. In contrast, the fundamental theory of fission under development at LLNL is much more predictive, but its current computational cost is too high to be used extensively for data evaluations. A unique window of opportunity to resolve these limitations has recently opened: the U.S. nuclear science community is ramping up major experimental programs at the Facility for Rare Isotope Beams (FRIB, the DOE flagship facility in low-energy nuclear science), and techniques from machine learning have shown great potential to simplify the use of a fundamental, quantum-mechanical theory of fission. This project has two components. On the experimental side, we acquired and deployed at the HIGS facility a new dual Frisch-Grid ionization chamber to measure correlated fragment-mass, kinetic energy, and angular distributions of fission fragments from induced fission. This new device was used to perform measurements of charge, mass and total kinetic energy of fission fragments in the photofission of 238 U and eight gamma-ray beam energies between 6.2 and 13 MeV, which allowed extracting high-precision independent yields for this reaction. The device was also used to perform measurements of the same quantities in the neutron-induced fission of 234 U with monoenergetic beams of energy between 5 and 8 MeV. In parallel, we collaborated with a team at Commissariat à l’énergie atomique et aux énergies alternatives (CEA) to perform a series of measurements of fission yields in inverse kinematics for the two isotopes of 236 U and 240 Pu. The experiment took place at the Grand Accélérateur National d’Ions Lourds in France in June 2023. The deployment of the VAMOS spectrometer with a new array called PISTA allowed determining the excitation energy of the fissioning system within 1 Mega-electronvolts. The second component of the project involved using deep neural networks to build fast and reliable emulators of our current fission models. In an invited paper published in Frontier in Physics, we showed that autoencoders could successfully compress nuclear wavefunctions in nuclear density functional theory. We achieved a dimensionality reduction of the order of two orders of magnitude while keeping the error in the total energy to less than 0.01%. In a second paper submitted to Physical Review Letters in June 2023 with our collaborators at CEA, we showed that variational autoencoders can learn the collective degrees of freedom driving the fission process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constraining the local pulsar population with the cosmic-ray positron fraction

Observations of the TeV halos associated with nearby pulsars indicate that these objects inject significant fluxes of very high-energy electron-positrons pairs into the interstellar medium (ISM), thereby likely providing the dominant contribution to the cosmic-ray positron flux. In this paper, we use the cosmic-ray positron fraction as measured by the AMS-02 Collaboration to constrain the characteristics of the local pulsar population. For reasonable model parameters, we find that we can obtain good agreement with the measured positron fraction up to energies of E e ~ 300 GeV. At higher energies, the positron fraction is dominated by a small number of pulsars, making it difficult to reliably predict the shape of the expected positron fraction. The low-energy positron spectrum supports the conclusion that pulsars typically transfer approximately η ~ 5–20% of their total spindown power into the production of very high-energy electron-positron pairs, producing a spectrum of such particles with a hard spectral index, α ~ 1.5–1.7. Such pulsars typically spindown on a timescale on the order of τ ~ 10 4 years. Our best fits were obtained for models in which the radio and gamma-ray beams from pulsars are detectable to 28% and 62% of surrounding observers, respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Laser Network US Experiments at the University of Texas at Austin

Under Subcontract B638654, The University of Texas at Austin (UT Austin) Center for High Energy Density Science supported three Laser Network US experiments and conducted upgrade planning for the Texas Petawatt Laser Facility. For the experiment “Investigation of the physics of MeV X-ray and particle generation using Compound Parabolic Concentrators” led by Dr. Andrew Mackinnon of Lawrence Livermore National Laboratory, UT Austin provided postdoctoral associate support in the person of Dr. Ganesh Tiwari. For the experiments “Megatesla magnetic fields and enhanced gamma-ray beam generation” led by Hans Rinderknecht of LLE, University of Rochester (experiment) and Alexey Arefiev of UC San Diego (theory) and “High resolution imaging of resonately accelerated electrons under tight focusing” led by Deepak Kumar of ELI-Beamlines, Czech Republic, UT Austin provided the Texas Petawatt Laser staff and a prorated share of the materials and supplies approximately equal to the average of those required for one 5-week experimental campaign. Summaries of these three experiments are provided in this report. Two staff members were hired—Dr. Sandra Bruce at 40% and Dr. Erhard Gaul at 50% time—to support Texas Petawatt Laser maintenance and operations and to plan for the Texas Relativistic Intensity Ultrafast Multi-beam Plasma Facility (TRIUMPF).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cross Section Measurements of Photonuclear Reaction Pathways Towards Promising Medical Radioisotopes

Project Objectives: The goal of this project was to generate data relevant to radioisotope production while developing innovative technologies that foster and enhance novel production of radioisotopes, and, also, while providing opportunities for cultivating and training future generations of scientists. This work has provided the foundation for methodologies for determination of photonuclear cross sections over multiple energies in a single irradiation. Simultaneously, the feasibility of electron LINAC production of several in-demand radioisotopes such as 47 Sc, 67 Cu, 77 As, and 186 Re has been demonstrated. To accomplish these objectives a collaboration was formed between two complimentary facilities, the Low Energy Accelerator Facility (LEAF) at Argonne National Laboratory and the High Intensity Gamma-ray Source (HIGS) at Triangular Universities Nuclear Laboratory (TUNL). The involvement of the research group from North Carolina Central University gave students at this Historically Black University experience in forefront nuclear-physics research relevant to addressing a high-priority interdisciplinary issue. Project Description: HIGS provides a nearly monoenergetic gamma-ray beam by intra-cavity Compton backscattering of free-electron photons from electrons circulating in a storage ring. This beam can be collimated to produce a very precise energy beam. If the beam is un-collimated a calculated and precise energy spread of the beam occurs radially. The γ-flux can be evenly distributed over the radial distribution of energy and used to perform activation experiments on concentric ring targets. Thus providing multiple energy ranges in a single irradiation. Each concentric ring target can be counted separately in order to determine activation at the given energy and successively be correlated to the activation cross section. Targets were activated to determine production feasibility using electron beams at LEAF. Potential Impact: The Nuclear Science Advisory Committee recently named production of radioisotopes with electron LINACs as one of the most compelling and largest-impact opportunities for the production of high specific activity radioisotopes. Improving the photonuclear cross sectional data base with experimentally verified results will greatly enhance a researcher’s ability to rationalize electron LINAC production routes towards desired radioisotopes. This work will provide the foundation for methodologies for determination of photonuclear cross sections over multiple energies and multiple targets in a single irradiation. The techniques developed in this project will enable future studies to continue verifying theoretically predicted photonuclear cross section with experimental results. These data will also enable adaptation of models and support more precise theoretical calculation of photonuclear cross sections. This research will involve undergraduates, graduate students, and post-docs to give them a valuable research experience leading towards the next generation of scientists in the field of medical isotopes.

07 ISOTOPE AND RADIATION SOURCES↗

High-contrast, convergent x-ray imaging with laser-Compton sources

Techniques are provided for the production of high-contrast, x-ray and/or gamma-ray radiographic images. The images have minimal contributions from object-dependent background radiation. The invention utilizes the low divergence, quasi-monoenergetic, x-ray or gamma-ray output from a laser-Compton source in combination with x-ray optical technologies to produce a converging x-ray or gamma-ray beam with which to produce a high-contrast, shadowgraph of a specific object. The object to be imaged is placed within the path of the converging beam between the x-ray optical assembly and the focus of the x-ray beam produced by that assembly. The beam is then passed through an optically thick pinhole located at the focus of the beam. Downstream of the pinhole, the inverted shadowgraph of the object is then recorded by an appropriate 2D detector array.

Barty, Christopher P. J.↗

Direct comparison of gamma, electron beam and X-ray irradiation doses on characteristics of low-density polyethylene, polypropylene homopolymer, polyolefin elastomer and chlorobutyl rubber medical device polymers

There is a growing need for increased efficiency in the sterilization of single use medical devices and other products that contain polymer components. Gamma radiation is widely used for devices suited for radiation sterilization; however, safety, throughput and cobalt-60 source availability are challenging the prospect of relying on gamma radiation to meet the anticipated needs of the industry. Use of electron beam (e-beam) and X-rays as alternatives to gamma for radiation sterilization have been hampered in part by a concern that these modalities may adversely affect polymer integrity and performance relative to the gamma method, for which the industry has had much more experience. To address this concern, the effects of sterilization-relevant doses of ebeam, X-ray and gamma radiation were directly compared using common medical device polymers found in two prototypical commercial devices currently sterilized using cobalt-60 gamma irradiation. The Becton, Dickinson and Company (BD) Vacutainer™ Plus tube contains low-density polyethylene and chlorobutyl rubber components, while the BD Vacutainer™ Push Button Blood Collection Set contains polypropylene homopolymer and polyolefin elastomer components. Injection-molded samples prepared from the polymers used in these products were exposed to target doses of 15, 35, 50 and 80 kGy using gamma, e-beam and X-ray radiation. Changes in coloration, tensile properties and hardness were measured for each condition, and the effects of e-beam and X-ray irradiation compared with the effects of gamma irradiation on these properties. Both e-beam and X-ray appear as viable alternatives to gamma irradiation for sterilization of the polymers tested.

sterilization, gamma, X-ray, electron beam, radiat↗