Search NASA⌕ Search

SEARCH · Search NASA

Results for “GAMMA SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Machine learning framework for predicting uranium enrichments from M400 CZT gamma spectra

A machine learning framework was developed for predicting uranium enrichments from M400 CZT gamma spectra. This framework leverages the availability of a large amount of measured M400 gamma spectra and uses a recently updated version of Gamma Detector Response and Analysis Software (GADRAS) for gamma spectrum analysis and generation. It also leverages the existing machine learning modules in Python for gamma spectrum data processing, curation, model training, benchmarking, and optimization of the deep machine learning models. The framework is used to develop a deep learning model to analyze gamma spectra from a set of U 3 O 8 samples with enrichments ranging from 0.31 to 93.17% and UF 6 cylinders with enrichments ranging from 0.2 to 4.95%, and the model performance is tested using a set of measured spectra and the respective declared enrichment values. Results show that the model can correctly classify 99.35% of the U 3 O 8 sample enrichments, and can predict the samples’ enrichments within an average absolute error of 0.099% (in percentage points of enrichment). For the UF 6 cylinders, the average absolute error was approximately 0.03%, with an accuracy of 98% in classifying discrete enrichment values of UF 6 samples. Finally, the results also show that the model has performed significantly better in terms of predicting enrichments in UF 6 cylinders based on measured gamma spectra than the GEM code, with a standard deviation (of the relative errors) of 2.23% (compared with the 11.51% value for the GEM code) based on results from a set of test data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A semi-supervised learning method to produce explainable radioisotope proportion estimates for NaI-based synthetic and measured gamma spectra

Quantifying the radioactive sources present in gamma spectra is an ever-present and growing national security mission and a time-consuming process for human analysts. While machine learning models exist that are trained to estimate radioisotope proportions in gamma spectra, few address the eventual need to provide explanatory outputs beyond the estimation task. In this work, we develop two machine learning models for a NaI detector measurements: one to perform the estimation task, and the other to characterize the first model’s ability to provide reasonable estimates. To ensure the first model exhibits a behavior that can be characterized by the second model, the first model is trained using a custom, semi-supervised loss function which constrains proportion estimates to be explainable in terms of a spectral reconstruction. The second auxiliary model is an out-of-distribution detection function (a type of meta-model) leveraging the proportion estimates of the first model to identify when a spectrum is sufficiently unique from the training domain and thus is out-of-scope for the model. In demonstrating the efficacy of this approach, we encourage the use of meta-models to better explain ML outputs used in radiation detection and increase trust.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of Isotopes in Urban Source Search Low-Count Gamma Spectra Using Hopfield Neural Networks

Source search campaigns involve measurements of background gamma-ray spectra with a mobile detector-spectrometer traveling along arbitrarily chosen trajectories over a wide screening area. Radiation counts are typically measured with a tellurium-doped sodium iodide [NaI(Tl)] scintillator detector-spectrometer in short acquisition intervals, usually 1 s. The objective is to detect orphan isotopes with half-lives shorter than those of the isotopes in the natural background. In principle, radioisotopes can be identified by their unique gamma emission spectrum. However, detecting orphan isotopes in search data is challenging because low counts measured in short acquisition intervals result in incomplete spectral lines. In this study, we investigate the performance of a Hopfield neural network (HNN) that implements an auto-associative memory for the detection of isotopes of interest in an urban search campaign. The HNN is trained on one example of gamma spectra with well-resolved spectral lines of each isotope of interest. During testing, the auto-associative memory implementation of the HNN processes low-count gamma spectra with partially complete isotopic lines by matching incoming measurements to the closest one of its memory-stored patterns. The testing database consisted of almost 10 000 1-s gamma spectra, including measurements of orphan isotopes 137 Cs, 241 Am, and 131 I, obtained during two urban search surveys with a NaI(Tl) detector. The performance of the HNN detection algorithm was evaluated using precision, recall, and F1 scores, and benchmarked with a multiple linear regression (MLR) identification algorithm. In conclusion, the test results demonstrate that HNN outperforms MLR in the detection of all the isotopes of interest.

Auto associative memory↗

Multilabel proportion prediction and out-of-distribution detection on gamma spectra of short-lived fission products

In the machine learning problem of multilabel classification, the objective is to determine for each test instance which classes the instance belongs to. In this work, we consider an extension of multilabel classification, called multilabel proportion prediction, in the context of radioisotope identification (RIID) using gamma spectra data. We aim to not only predict radioisotope proportions, but also identify out-of-distribution (OOD) spectra. We achieve this goal by viewing gamma spectra as discrete probability distributions, and based on this perspective, we develop a custom semi-supervised loss function that combines a traditional supervised loss with an unsupervised reconstruction error function. Our approach was motivated by its application to the analysis of short-lived fission products from spent nuclear fuel. In particular, we demonstrate that a neural network model trained with our loss function can successfully predict the relative proportions of 37 radioisotopes simultaneously. The model trained with synthetic data was then applied to measurements taken by Pacific Northwest National Laboratory (PNNL) to conduct analysis typically done by subject-matter experts. Here, we also extend our approach to successfully identify when measurements are OOD, and thus should not be trusted, whether due to the presence of a novel source or novel proportions.

Anomaly detection↗

International database of reference gamma spectra for nuclear safeguards applications

Nuclear safeguards missions use gamma spectroscopy as a non-destructive measurement technique for examining nuclear materials. Despite advances in the development of detection equipment as well as software codes, one of the concerns is the lack of well-documented spectra needed to test and validate isotopic analysis codes for their applicability. To address this need, this work introduces IDB, an international database of the reference gamma spectra of uranium, plutonium and mixed oxide nuclear material samples. IDB provides access to well-characterized sets of gamma spectra described by rich metadata, including information on the sample, measurement configuration and detector specifications. These spectra are accessible in different formats, also compatible with analysis code standards, thus promoting their sustainability and maintenance.

None, Dipti [International Atomic Energy Agency (I↗

Beta-delayed gamma spectra compilation and analysis following the thermal-neutron induced fission of 235 U, 239,241 Pu

The integral gamma and electron spectra emitted by fission products, also known as delayed gamma and electron spectra, were measured at Oak Ridge National Laboratory in the 1970s for the thermal-neutron induced fission of 235 U and 239,241 Pu. Scintillator detectors were used to measure these spectra, data used later on to obtain decay heat values - that is, the spectra mean values per unit time as function of time - work that was published in the Nuclear Science and Technology journal; the spectral data, however, was only published in laboratory reports. Here, in this work, we analyze the gamma spectra data using modern methods and nuclear databases to reveal the signature of individual fission products as well as to gauge the performance of the ENDF/B-VIII.0 decay data sub-library, concluding about possible future enhancements in predictive capabilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Simulation of Isotopic Concentrations and Gamma Spectra from Dynamic Fission Sources

A tool was developed to rapidly generate synthetic gamma-ray spectra to evaluate safeguards material control and accounting methods for liquid-fueled molten salt reactors. Molten salt reactor operations pose unique challenges to nuclear safeguards methods and protocols compared to deployed reactors designs (e.g., light water reactors). This research evaluates the use of gamma-ray spectroscopy to monitor fission product isotopic flow through a reactor model to understand expected operations and investigate changes to the spectra with material diversion scenarios. The large design space of molten salt reactors (e.g., liquid-fueled, liquid-cooled, online separations) could potentially lead to many measurement points within the reactor system. The developed analytical tool generates and evaluates synthetic gamma-ray spectra from dynamic reactor simulations by extracting isotopic inventory to generate source terms. An implementation in the Gamma Detector Response and Analysis Software (GADRAS) Application Program Interface (API) uses the source terms, a model of the reactor component, a detector response function, and measurement plan to quickly generate and analyze spectra. Prospective measurements are then evaluated in the more accurate but slower Geant4 simulations. Utilization of the developed modeling tool and analysis of the subsequent spectra enables optimization of collimation, shielding requirements, and expected count rates that are used to determine key measurement points in the modeled reactor design.

O'Brien, Sean↗

GADRAS + Geant4 Simulated Gamma Spectra Dataset

This dataset contains GADRAS and Geant4 simulated gamma-ray energy spectra used in the papers "Sim-to-real supervised domain adaptation for radioisotope identification" (https://doi.org/10.1016/j.nima.2025.171159) and "Unsupervised domain adaptation for radioisotope identification in gamma spectroscopy" (https://arxiv.org/abs/2603.05719). Each spectrum contains a mixture of several different radioisotopes, and the goal of the analysis is to leverage domain adaptation techniques to use a model trained on source-domain spectra (GADRAS) to classify target-domain spectra (Geant4).

Lalor, Peter William [Pacific Northwest National L↗

Data Analyst - A Device for Continuous Repeating Real-Time Assay of HPGe, CZT, or Scintillation Gamma Spectra - 18574

There are many situations where a continuous repeating series of quantitative gamma spectral assays is desirable. These include measurements of fluid going through a pipe, of items on a conveyor passing under a detector, a detector aimed at the ground on a moving platform, or a detector in free air as a plume of radioactivity drifts by. While Canberra and many others have built and deployed many of these devices, they have all been custom built for that particular application, and rather expensive. The Data Analyst [DA] is a general purpose device that is designed to fulfill many of these applications without modification, but can be fairly-easily modified if needed. The DA is a small [12 x 18 x 5 cm], low-power [3 W] box that accepts the input from external MCAs, controls the acquisition cycle, analyzes the results, and transmits them to the outside world when needed. The detector-MCAs supported are HPGe with Lynx MCA, NaI or CeBr or LaBr with Osprey MCA, and CZT or CsI with internal MCAs. The DA internal software used for analysis is the full standard Genie analysis software, which is very widely used and well accepted in the industry. This allows exported spectral files to be reviewed and confirmed by Experts, and reanalyzed if needed. The DA hardware is totally autonomous. As soon as power is applied, it starts the pre-programmed sequences of acquisition and analysis. Multiple analysis sequences [called Workflows] can be in operation simultaneously, e.g. with different count times and different nuclide libraries. Only the detector with MCA, and the DA are required in the field. A PC can be connected to the DA locally or remotely via WiFi, USB, or Ethernet. The PC is needed to setup the DA, and to readout the results. The DA also supports [with application-specific programming] external Inputs/Outputs either for recording with the analysis results or for use in the computation of the result, e.g. temperature, flow rate, pressure, ... ]. The DA also has an internal GPS receiver with external antenna. Applications of the DA that are discussed include stack gas effluent activity where a portion of the effluent stream was extracted to flow through a shield with a HPGe detector and Lynx MCA, and measurement of reactor coolant activity where a shielded CZT detector and MCA were aimed at various sections of reactor primary coolant during a maintenance outage. Potential other applications are also described. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Detection of Isotopes in Urban Source Search Gamma Spectra Using Hopfield Neural Network

Source search campaigns involve the measurement of consecutive background gamma-ray spectra obtained with a mobile detector-spectrometer, such as tellurium-doped sodium iodide NaI(Tl) scintillator detector-spectrometer. Counts are measured with NaI(Tl) detector in short acquisition intervals, such as one second. Detection of isotopes in search data is challenging because of the low signal-to-noise ratio (S/N) of the spectral lines and highly varying background due to naturally occurring radioactive material (NORM). In this work, we investigate the performance of the detection of orphan Cs-137, Am-241, and I-131 isotopes in a gamma ray data set obtained in a search survey. Isotopic detection is performed with a Hopfield Neural Network (HNN), which implements an auto-associative memory by matching incoming measurements to the closest one of its memory-stored signature patterns. HNN is trained on examples of spectra of calibrated isotopic sources with well-resolved spectral lines. During testing, HNN processes spectra with partially complete or distorted isotopic lines. The performance of the HNN detection algorithm is benchmarked with Precision, Recall, and F1 scores. Test results demonstrate the potential of HNN to detect the isotope of interest with high accuracy (F1 > 90%) for all isotopes in this study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Anomaly Detection in Gamma Spectra Using Hopfield Neural Network with B-SAT and Grover’s Algorithm on a Quantum Computing Simulator

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. In principle, gamma radiation sources can be detected and identified by their unique spectral lines. However, detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. In recent prior work, we have developed a Hopfield Neural Network (HNN) in conjunction with an image processing algorithm to detect a weak signal anomaly hidden among the highly fluctuating background spectra. The objective of this work is to explore quantum computing methods to increase the speed of HNN. The approach is based on the Grover’s search algorithm in conjunction with a 3-SAT problem formalism. The Grover’s algorithm is implemented on a quantum computing simulator using Qiskit software. Performance of HNN algorithm is benchmarked using search data from an environmental screening campaign, where the anomaly is a subset of measurements containing a 137 Cs source. Results indicate that using Grover’s algorithm on a quantum simulator reduces runtime of HNN by two orders of magnitude.

61 RADIATION PROTECTION AND DOSIMETRY↗

Questionnaire for Radioisotope Identification and Estimation from Gamma Spectra using PyRIID v2

Accurate targeting of radioisotope classifiers and estimators requires an understanding of the target problem space. In order to facilitate clear communication on expected model behavior and performance between practitioners and stakeholders on their problems, this questionnaire was created. Stakeholder responses form the basis of a trained model as well as the start of usage requirements for the model as it is integrated with analysis processes or detection systems. This questionnaire may also be useful to machine learning practitioners and gamma spectroscopists developing new algorithms as a starting point for characterizing their problem space, especially if they are using PyRIID.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dose Calculations from Source Models and Gamma-Ray Spectra

Gamma-ray dose rates computed by two radiation source model-based methods and five measured spectrum-based methods are compared. With the exception of a Detective DX-100, which reported dose rates that are about 25% less than the mean, dose rates are generally within 10% of mean values. Methods for computation of dose rates employed by the Gamma Detector Response and Analysis Software (GADRAS) are described and critically evaluated. Results are presented for a feasibility evaluation that seeks to use spectra recorded inside vehicles to estimate the minimum dose outside the vehicles.

61 RADIATION PROTECTION AND DOSIMETRY↗

Assessment of Gamma-Ray-Spectra Analysis Method Utilizing the Fireworks Algorithm for Various Error Measures

The analysis of measured data plays a significant role in enhancing nuclear nonproliferation mainly by inferring the presence of patterns associated with special nuclear materials. Among various types of measurements, gamma-ray spectra is the widest utilized type of data in nonproliferation applications. In this paper, a method that employs the fireworks algorithm (FWA) for analyzing gamma-ray spectra aiming at detecting gamma signatures is presented. In particular, FWA is utilized to fit a set of known signatures to a measured spectrum by optimizing an objective function, where non-zero coefficients express the detected signatures. FWA is tested on a set of experimentally obtained measurements optimizing various objective functions—MSE, RMSE, Theil-2, MAE, MAPE, MAP—with results exhibiting its potential in providing highly accurate and precise signature detection. Finally and furthermore, FWA is benchmarked against genetic algorithms and multiple linear regression, showing its superiority over those algorithms regarding precision with respect to MAE, MAPE, and MAP measures.

97 MATHEMATICS AND COMPUTING↗

Draft Specification for Representing Gamma Radiation Spectra in QR codes

This document defines a proposed specification for representing gamma radiation spectra, as commonly produced by handheld Radioisotope Identifiers, as a QR code, or as a Uniform Resource Identifier (URI). The intended primary application is transferring spectra between locations or devices using standard smart-phone capabilities when data transmission would otherwise be challenging or not possible. The proposed encoding also enables embedding of spectra within other documents as hyperlinks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Monitoring Aqueous Reprocessing Systems for Detection of Facility Misuse

Traditional approaches to material control and accounting at used nuclear fuel reprocessing facilities relies in large part on laboratory-based destructive assay of periodic samples taken from key stages. These techniques are highly accurate, but limited inspection frequency may limit the size and operation of a reprocessing facility. Online monitoring techniques using inline detectors can be applied to fuel reprocessing systems to improve the situational awareness as the facility is operating to provide additional indicators of the evolving state of the facility between normal inspection periods, potentially alerting regulators to the need for additional inspection. The Multi-Isotope Process (MIP) Monitor combines medium-resolution gamma detectors with statistical data analysis techniques to monitor reprocessing systems for anomalous conditions resulting from process control issues or malfeasance. Gamma spectra collected from the H-Canyon reprocessing facility were modeled using principal component analysis to demonstrate the efficacy of the MIP Monitor for detecting notional diversion scenarios.

safeguards, nuclear fuel reprocessing, gamma spect↗