Search NASASearch

SEARCH · Search NASA

Results for “GAS CELL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Investigations of laser pumped gas cell atomic frequency standard

The performance characteristics of a rubidium gas cell atomic frequency standard might be improved by replacing the standard rubidium discharge lamp with a single mode laser diode. Aspects of the laser pumped gas cell atomic clock studied include effects due to laser intensity, laser detuning, and the choice of the particular atomic absorption line. Results indicate that the performance of the gas cell clock may be improved by judicious choice of the operating parameters of the laser diode. The laser diode also proved to be a valuable tool in investigating the operation of the conventional gas cell clock. Results concerning linewidths, the light shift effect and the effect of isotopic spin exchange in the conventional gas cell clock are reported.

Volk, C. H.

Recent developments and applications with gas cell correlation spectrometer

Gaspec, a gas filter correlation spectrometer, is described. Gaspec is a dual-gas three-channel instrument using two detectors which receive amplitude-shared source signals modulated at the frequency of the chopper. Several units for operation around the 3-5 micron and the 8-15 micron region have been constructed, and gases such as CO2, CO, CH4, HCl, NO, and hydrazines can be detected. Advantages of Gaspec are considered with reference to improvements developed for the basic Cospec (gas cell correlation spectrometer) instrument.

Barringer, A. R.

Laser induced asymmetry and inhomogeneous broadening of the microwave lineshape of a gas cell atomic frequency standard

The possibility of replacing the RF discharge lamp in a rubidium gas cell clock with a single mode laser diode is addressed. Since the short term stability of the rubidium frequency standard is limited by the shot noise of the photodetector, an increased signal-to-noise ratio due to more efficient laser diode optical pumping might improve the short term performance. Because the emission wavelength of the laser diode can be tuned, improved long term performance could be gained through the control of the light shift effect. However, due to the nature of the gas cell frequency standard, various physical phenomena are strongly coupled in their effect on the frequency output, and thus careful consideration must be given to any change in one parameter because of its interrelation with other parameters. Some investigations concerning the coupled effect of the optical and microwave fields in the rubidium atomic clock are reported. It is shown that this type of coupling is an important consideration for any attempt to incorporate a laser diode into a gas cell clock.

Camparo, J. C.

Halogen Occultation Experiment (HALOE) gas cell life test program

The Halogen Occultation Experiment (HALOE) will use gas filter correlation radiometry to measure the atmospheric concentration profiles of HCl, HF, NO, and CH4 from the Upper Atmosphere Research Satellite. The need to contain the gases for the gas filter measurements has resulted in the development of gas cells and the need for a life test program to demonstrate that the gas cells will perform their functions for extended periods (several years) of time. This report describes the tests in the life test program, the test apparatus used, and the analysis techniques developed. The report also presents data obtained during the first 14 months of the test program.

Sullivan, E. M.

Improved atomic resonance gas cell for use in frequency standards

Atomic resonance gas cell maintains a stable operating frequency in the presence of pressure fluctuations in the ambient atmosphere. The new cell includes an envelope which is transparent to radiation in the optical region and to microwave energy at the atomic resonance frequency of the alkali-metal vapor within the envelope.

Huggett, G. R.

Fabrication of glass gas cells for the HALOE and MAPS satellite experiments

The Halogen Occultation Experiment (HALOE) and the Measurement of Air Pollution from Satellites (MAPS) experiment are satellite-borne experiments which measure trace constituents in the Earth's atmosphere. The instruments which obtain the data for these experiments are based on the gas filter correlation radiometer measurement technique. In this technique, small samples of the gases of interest are encapsulated in glass cylinders, called gas cells, which act as very selective optical filters. This report describes the techniques employed in the fabrication of the gas cells for the HALOE and MAPS instruments. Details of the method used to fuse the sapphire windows (required for IR transmission) to the glass cell bodies are presented along with detailed descriptions of the jigs and fixtures used during the assembly process. The techniques and equipment used for window inspection and for pairing the HALOE windows are discussed. Cell body materials and the steps involved in preparing the cell bodies for the glass-to-sapphire fusion process are given.

Sullivan, E. M.

Rubidium gas cell studies

The stability of Rb-87 optically pumped masers and Rb gas cells is examined. Descriptions are given of the technical procedures used in construction and the changes made to solve the problems encountered in the electronics of the systems.

Vanier, J.

Elimination of the light shift in rubidium gas cell frequency standards using pulsed optical pumping

Changes in the intensity of the light source in an optically pumped, rubidium, gas cell frequency standard can produce corresponding frequency shifts, with possible adverse effects on the long-term frequency stability. A pulsed optical pumping apparatus was constructed with the intent of investigating the frequency stability in the absence of light shifts. Contrary to original expectations, a small residual frequency shift due to changes in light intensity was experimentally observed. Evidence is given which indicates that this is not a true light-shift effect. Preliminary measurements of the frequency stability of this apparatus, with this small residual pseudo light shift present, are presented. It is shown that this pseudo light shift can be eliminated by using a more homogeneous C-field. This is consistent with the idea that the pseudo light shift is due to inhomogeneity in the physics package (position-shift effect).

English, T. C.

Air Contamination Quantification by FTIR with Gas Cell

Air quality is of utmost importance in environmental studies and has many industrial applications such as aviators grade breathing oxygen (ABO) for pilots and breathing air for fire fighters. Contamination is a major concern for these industries as identified in MIL-PRF-27210, CGA G-4.3, CGA G-7.1, and NFPA 1989. Fourier Transform Infrared Spectroscopy (FTIR) is a powerful tool that when combined with a gas cell has tremendous potential for gas contamination analysis. Current procedures focus mostly on GC-MS for contamination quantification. Introduction of this topic will be done through a comparison of the currently used deterministic methods for gas contamination with those of FTIR gas analysis. Certification of the mentioned standards through the ISOIEC 17065 certifying body A2LA will be addressed followed by an evaluation of quality information such as the determinations of linearity and the limits of detection and quantitation. Major interferences and issues arising from the use of the FTIR for accredited work with ABO and breathing air will be covered.

Freischlag, Jason

Application of Long-Path Gas Cell Assisted Infrared Spectroscopy for Detection of Lunar Volatiles and Advanced Curation Efforts

The motivation behind analyzing gaseous samples from the Permanently Shadowed Regions (PSRs) on the lunar surface is built upon the volatiles observed during the LCROSS mission. Advanced curation techniques under cold conditions are essential to the critical scientific analysis of these returned samples. The detection of various volatiles in returned samples by gas-phase infrared (IR) spectroscopy is known to be a powerful tool to understand the resources present in planetary bodies and Astro-materials. The identification and quantification of volatile compounds in returned planetary samples and regolith simulants by advanced and custom-built analytical devices are areas of primary research interest in our group and the Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility. In this context, we discuss recent advancements and experimental results for quick analysis of the major volatiles detected by the LCROSS (water, CO 2 , CH 3 OH, and NH 3 ) by a long-path gas cell/FTIR (Fourier Transform Infrared) spectrometer system. The applicability of this system is demonstrated by qualitative analysis of a series of volatiles measured individually. In addition, the linear dependence of absorption intensity on headspace sample volumes was checked by measuring gas-phase IR absorption spectra of increasing volumes of pure CO 2 gas aliquots. Finally, the instrument performance was evaluated by measuring the relative concentration of NH 3 (g) in methanol solution.

Curation

Rubidium-87 gas cell studies, phase 1

The construction of a quartz bulb-quartz cavity type rubidium maser is described, and the results obtained with two of these masers are presented. The tuning characteristics, medium term stability, and short term stability are reported. It is concluded that the stability of the masers in the short term region is superior to any of the oscillators presently existing. On this basis it is believed that future development of the masers to reduce their size and improve their medium term stability is well justified.

Vanier, J.

Rubidium-87 gas cell studies, phase 2

A description is given of the development of a compact rubidium-87 maser. Data cover the electronic control system for the maser itself and a superhetrodyne receiver capable of locking a crystal oscillator to the maser signal.

Vanier, J.

Rubidium 87 gas cell studies, phase 2

The design, development, and characteristics of a rubidium 87 maser are discussed. The design of a receiver capable of locking a crystal oscillator to the maser signal is reported. The subjects considered are: (1) maser construction, (2) maser control electronics, (3) the characteristics of the receiver, and (4) results of experimental maser tests.

Vanier, J.

The physics of the environmental sensitivity of rubidium gas cell atomic frequency standards

Environmental sensitivity is often the most significant limitation to the practical stability of rubidium frequency standards (RFS). For example, temperature sensitivity can cause a rapid frequency change of several parts in 10(exp 10) for a tactical RFS that has an aging of only 1 times 10(exp -11)/month. Other important environmental factors are barometric pressure, vibration, magnetic field, and nuclear radiation. The physical mechanisms that lie behind these environmental sensitivities are considered. These physical mechanisms are related to the performance of actual rubidium frequency standards. For the user of these devices, a better knowledge of the causes for Rb clock instability will aid in their testing and proper application. For the time frequency specialist, a review of these factors may prove useful toward improving RFS design. Some of the RFS environmental sensitivities are due to simple physical mechanisms like the effect of dc magnetic field on the Rb hyperfine resonance frequency. For these, an analysis can be based on physical principles and straightforward design factors. Other environment factors, like temperature sensitivity, are more complex combinations of many effects, both physical and practical, and the analysis often takes the form of an error budget with large unit-to-unit variations. Today's rubidium frequency standards span a wide performance range from small, inexpensive units with pp 10(exp 10) error budgets to larger, higher performance versions offering pp 10(exp 10) stabilities. For both extremes, however, environmental sensitivity can be the most significant performance limitation. Why this is the case and how to make improvements are discussed.

Riley, William J.

Optimization of A 2-Micron Laser Frequency Stabilization System for a Double-Pulse CO2 Differential Absorption Lidar

A carbon dioxide (CO2) Differential Absorption Lidar (DIAL) for accurate CO2 concentration measurement requires a frequency locking system to achieve high frequency locking precision and stability. We describe the frequency locking system utilizing Frequency Modulation (FM), Phase Sensitive Detection (PSD), and Proportional Integration Derivative (PID) feedback servo loop, and report the optimization of the sensitivity of the system for the feed back loop based on the characteristics of a variable path-length CO2 gas cell. The CO2 gas cell is characterized with HITRAN database (2004). The method can be applied for any other frequency locking systems referring to gas absorption line.

Chen, Songsheng

Laser Frequency Stabilization for Coherent Lidar Applications using Novel All-Fiber Gas Reference Cell Fabrication Technique

Compact hollow-core photonic crystal fiber (HC-PCF)gas frequency reference cell was constructed using a novel packaging technique that relies on torch-sealing a quartz filling tube connected to a mechanical splice between regular and hollow-core fibers. The use of this gas cell for laser frequency stabilization was demonstrated by locking a tunable diode laser to the center of the P9 line from the (nu)1+(nu)3 band of acetylene with RMS frequency error of 2.06 MHz over 2 hours. This effort was performed in support of a task to miniaturize the laser frequency stabilization subsystem of JPL/LMCT Laser Absorption Spectrometer (LAS) instrument.

Laser Absorption Spectrometer (LAS)

Compact and Robust Refilling and Connectorization of Hollow Core Photonic Crystal Fiber Gas Reference Cells

This slide presentation reviews a method for refilling and connectorization of hollow core photonic crystal fiber gas reference cells. Thees hollow-core photonic crystal fiber allow optical propagation in air or vacuum and are for use as gas reference cell is proposed and demonstrated. It relies on torch-sealing a quartz filling tube connected to a mechanical splice between regular and hollow-core fibers.

hollow core fiber