Search NASA⌕ Search

SEARCH · Search NASA

Results for “GEARBOX FAILURES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Wind Turbine Gearbox Failure Modes - A Brief (Presentation)

Wind turbine gearboxes are not always meeting 20-year design life. Premature failure of gearboxes increases cost of energy, turbine downtime, unplanned maintenance, gearbox replacement and rebuild, increased warranty reserves. The problem is widespread and affects most Original Equipment Manufacturers. Not caused by manufacturing practices. Need to improve gearbox reliability and reduce turbinedowntime.

17 WIND ENERGY↗

Wind Turbine Gearbox Failure Detection Through Cumulative Sum of Multivariate Time Series Data

The wind energy industry is continuously improving their operational and maintenance practice for reducing the levelized costs of energy. Anticipating failures in wind turbines enables early warnings and timely intervention, so that the costly corrective maintenance can be prevented to the largest extent possible. It also avoids production loss owing to prolonged unavailability. One critical element allowing early warning is the ability to accumulate small-magnitude symptoms resulting from the gradual degradation of wind turbine systems. Inspired by the cumulative sum control chart method, this study reports the development of a wind turbine failure detection method with such early warning capability. Specifically, the following key questions are addressed: what fault signals to accumulate, how long to accumulate, what offset to use, and how to set the alarm-triggering control limit. We apply the proposed approach to 2 years’ worth of Supervisory Control and Data Acquisition data recorded from five wind turbines. We focus our analysis on gearbox failure detection, in which the proposed approach demonstrates its ability to anticipate failure events with a good lead time.

17 WIND ENERGY↗

Gearbox Reliability Collaborative Gearbox 1 Failure Analysis Report: December 2010 - January 2011

Unintended gearbox failures have a significant impact on the cost of wind farm operations. In 2007, NREL initiated the Gearbox Reliability Collaborative (GRC). The project combines analysis, field testing, dynamometer testing, condition monitoring, and the development and population of a gearbox failure database in a multi-pronged approach to determine why wind turbine gearboxes do not achievetheir expected design life. The collaborative of manufacturers, owners, researchers, and consultants focuses on gearbox testing and modeling and the development of a gearbox failure database. Collaborative members also investigate gearbox condition monitoring techniques. Data gained from the GRC will enable designers, developers, and manufacturers to improve gearbox designs and testing standardsand create more robust modeling tools. GRC project essentials include the development of two identical, heavily instrumented representative gearbox designs. Knowledge gained from the field and dynamometer tests conducted on these gearboxes builds an understanding of how the selected loads and events translate into bearing and gear response. This report contains the analysis of the first gearboxdesign.

17 WIND ENERGY↗

Prognosis of Wind Turbine Gearbox Bearing Failures Using SCADA and Modeled Data

Predictive maintenance and condition monitoring systems for wind turbines have seen increased adoption to minimize downtime, reducing operation and maintenance costs. On today’s wind power plants, the integrated supervisory control and data acquisition (SCADA) system provides low- frequency operational data that can be leveraged to quantify a wind turbine’s health. The aim of this study is to utilize machine-learning techniques to predict axial cracking failures in wind turbine gearbox bearings up to 1 month ahead of time. The failures are assumed to have occurred when the investigated bearing was replaced. While current SCADA systems show the overall condition of a wind turbine, often they do not allow for the investigation of specific gearbox bearings’ health. To enrich bearing fault signatures, additional data are computed through physics-based models using gearbox design information. Based on SCADA data, modeled data, and bearing failure log data from an actual wind plant, the performances of different machine-learning models on unseen data are then evaluated using industry-standard metrics such as precision, recall, and F1 score. Results show the overall system performance enhancement in predicting bearing failure when modeled data are included with SCADA data. The reduction in terms of false alarms is about 50%, and improvement in terms of precision and F1 score is about 33% and 12% respectively, based on the best modeling case in this study.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

NREL Collaborative Improves the Reliability of Wind Turbine Gearboxes [Fact Sheet]

Gearbox failures have a significant impact on the cost of wind farm operations. To help minimize gearbox failures, in 2007 the National Renewable Energy Laboratory (NREL) initiated the Gearbox Reliability Collaborative (GRC), which consists of manufacturers, owners, researchers, and consultants. Based on all the lessons learned from the past five years, the GRC has now produced a new and improved design, which is projected to yield an operating lifetime of 12 years, more than triple that of the previous redesigned gearbox. The GRC findings will result in increased gearbox reliability and an overall reduction in the cost of wind energy.

17 WIND ENERGY↗

OH-58 helicopter transmission failure analysis

The OH-58 main transmission gearbox was run at varying output torques, speeds, and oil cooling rates. The gearbox was subsequently run to destruction by draining the oil from the gearbox while operating at a speed of 6200 revs per minute and 36,000 inch-pounds output torque. Primary cause of gearbox failure was overheating and melting of the planet bearing aluminum cages. Complete failure of the gearbox occurred in 28 1/2 minutes after the oil pressure dropped to zero. The alternating and maximum stresses in the gearbox top case were approximately 10 percent of the endurance limit for the material. Deflection of the bevel gear at 67000 inch-pounds output torque indicate a marginal stiffness for the bevel gear supporting system.

Townsend, D. P.↗

Investigation of Various Wind Turbine Drivetrain Condition Monitoring Techniques

The wind industry has experienced premature turbine component failures during the past years. With the increase in turbine size, these failures, especially those found in the major drivetrain components, i.e. main shaft, gearbox, and generator, have become extremely costly. Given that the gearbox is the most costly component in the drivetrain to fix, the National Renewable Energy Laboratory (NREL) initiated the Gearbox Reliability Collaborative (GRC) to determine the causes for premature gearbox failures and subsequently, recommend improvements to gearbox design, manufacture, and operational practices. The GRC has two identical test gearboxes, which are planned for a dynamometer and a field test, respectively.

17 WIND ENERGY↗

Diagnostic Models for Wind Turbine Gearbox Components Using SCADA Time Series Data: Preprint

This paper presents a scalable, autonomous framework for diagnostics of wind turbine gearbox failures using a multi-feature supervisory control and data acquisition data set spanning multiple years. Because of the size of the data set studied, all algorithms were constructed to be scalable using a Spark-Hadoop data framework. An unsupervised approach was used to detect significant failures based on predetermined criteria. The initial criteria selected were an abnormal spike in turbine component temperature followed by a turbine power off, which helps reduce the number of potential false alarms. To detect abnormal spikes in component temperature, a model was introduced to adjust the temperature data for effects caused by ambient temperature and normal temperature increases when loaded. This study evaluates methods for normalizing temperature sensor data to identify anomalies. The models that performed the best were a linear regression and a multivariate polynomial regression. The proposed process for finding failures has tunable parameters that can be adjusted to be more or less sensitive. The combination of sensor data normalization and application of these criteria is successful in finding turbine failures resulting in downtime. The proposed methods can operate without failure or maintenance logs and can be utilized for offline analysis of large high-resolution data sets.

17 WIND ENERGY↗

Gearbox Reliability Collaborative Phase 3 Gearbox 2 Test Plan

Gearboxes in wind turbines have not been achieving their expected design life even though they commonly meet or exceed the design criteria specified in current design standards. One of the basic premises of the National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) is that the low gearbox reliability results from the absence of critical elements in the design process or insufficient design tools. Key goals of the GRC are to improve design approaches and analysis tools and to recommend practices and test methods resulting in improved design standards for wind turbine gearboxes that lower the cost of energy (COE) through improved reliability. The GRC uses a combined gearbox testing, modeling and analysis approach, along with a database of information from gearbox failures collected from overhauls and investigation of gearbox condition monitoring techniques to improve wind turbine operations and maintenance practices. Testing of Gearbox 2 (GB2) using the two-speed turbine controller that has been used in prior testing. This test series will investigate non-torque loads, high-speed shaft misalignment, and reproduction of field conditions in the dynamometer. This test series will also include vibration testing using an eddy-current brake on the gearbox's high speed shaft.

17 WIND ENERGY↗

Gearbox Reliability Collaborative Phase 3 Gearbox 2 Test

The National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) was established by the U.S. Department of Energy in 2006; its key goal is to understand the root causes of premature gearbox failures and improve their reliability. The GRC uses a combined gearbox testing, modeling, and analysis approach disseminating data and results to the industry and facilitating improvement of gearbox reliability. This test data describes the tests of GRC gearbox 2 in the National Wind Technology Center dynamometer and documents any modifications to the original test plan. It serves as a guide to interpret the publicly released data sets with brief analyses to illustrate the data. TDMS viewer and Solidworks software required to view data files.

17 WIND ENERGY↗

The DOE Next-Generation Drivetrain for Wind Turbine Applications: Gearbox, Generator, and Advanced Si/SiC Hybrid Inverter System: Preprint

This paper reports on the design and testing results from the U.S. Department of Energy Next-Generation Wind Turbine Drivetrain Project. The drivetrain design reduces the cost of energy by increasing energy capture through drivetrain efficiency improvements; by reducing operation and maintenance costs through reducing gearbox failures; and by lowering capital costs through weight reduction and a series of mechanical and electronic innovations. The paper provides an overview of the drivetrain gearbox and generator and provides a deeper look into the power converter system. The power converter has a number of innovations including the use of hybrid silicon (Si)/silicon carbide (SiC) isolated baseplate switching modules. Switching energies are compared between SiC and Si PIN diodes. The efficiency improvement by use of the SiC diode in a three-level converter is also described. Finally, a brief discussion covering utility interconnect requirements for turbines is provided with a particular focus on utility events that lead to high transient torque loads on drivetrain mechanical elements.

17 WIND ENERGY↗

Gearbox Reliability Collaborative Phase 3 Gearbox 3 Test

The GRC uses a combined gearbox testing, modeling, and analysis approach disseminating data and results to the industry and facilitating improvement of gearbox reliability. This test data describes the tests of GRC gearbox 3 in the National Wind Technology Center dynamometer and documents any modifications to the original test plan. It serves as a guide to interpret the publicly released data sets with brief analyses to illustrate the data. TDMS viewer and Solidworks software required to view data files. The National Renewable Energy Laboratory (NREL) Gearbox Reliability Collaborative (GRC) was established by the U.S. Department of Energy in 2006; its key goal is to understand the root causes of premature gearbox failures and improve their reliability.

17 WIND ENERGY↗

An accumulation method for early fault warning and its application to wind turbine systems

Unexpected failures in engineering systems lead to expensive maintenance actions and should be avoided if at all possible. This is particularly true for wind turbine systems for which unexpected failures not only demand costly repairs but also cause long downtime. Motivated by this need, we present an accumulation method for fault early warning and failure anticipation. Here, our research shows that one critical element allowing the ability of early warning is to accumulate the small-magnitude symptoms resulting from gradual changes in an engineering system like wind turbines. Our idea is inspired by the classical cumulative sum method, or CUSUM, but we have to redesign the accumulation mechanism for tackling unique challenges in wind turbine data. The new accumulation method is applied to two real wind turbine datasets, one with gearbox failures and the other with generator failures, and demonstrates superior performance as compared with CUSUM.

17 WIND ENERGY↗