Search NASA⌕ Search

SEARCH · Search NASA

Results for “GERMANIUM 73”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Nuclear Data Sheets for A=73☆

Experimental nuclear structure data for the known A=73 isobaric nuclides (Mn, Fe, Co, Ni, Cu, Zn, Ga, Ge, As, Se, Br, Kr, Rb and Sr) have been evaluated, and presented together with Adopted properties of level energies, and associated γ rays. The decay data for these nuclides have also been evaluated, providing Adopted values of γ and β radiations, and log ft values. For {sup 73}Mn, only the isotopic identification has been established, with no knowledge of its g.s. half-life. For {sup 73}Fe, {sup 73}Co and {sup 73}Sr, only the ground states and their half-lives are known with no information about the excited states. For {sup 73}Ni, {sup 73}Cu, {sup 73}Zn and {sup 73}Rb, little data are available for excited states. The half-life and decay modes of possibly proton-unbound {sup 73}Rb need firmly established. {sup 73}Ga structure presents a special challenge in that the 1/2{sup −} ground state and the first 3/2{sup −} state have recently been proposed, in a Coulomb excitation experiment by 2010Di14, to form an almost degenerate doublet with an estimated spacing of 229 Th with its first excited state at 7.8 eV, and {sup 235}U with its first excited state at 76 eV. Ultra-high resolution gamma-ray spectroscopic studies are warranted to search for the low-lying (73 Ga, and to determine its half-life. Level structures of {sup 73}Ga, {sup 73}Ge, {sup 73}As, {sup 73}Se, {sup 73}Br and {sup 73}Kr are quite well known, although decay schemes of radioactive ground states of {sup 73}Co, {sup 73}Cu and {sup 73}Br are considered incomplete. The reactions and decays for which no new experimental information has become available since the 2003 update have undergone revisions to incorporate conversion coefficients from BrIcc code, and evaluated Q values from 2017Wa10, but essential content of such datasets may have remained the same as in previous evaluations. In this respect the present work greatly benefited from all the previous NDS evaluations (2004Si08,1993Ki25,1987Ki13, 1980Ek01,1974Al33), but at the same time data presented herein supersede all the previous published evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Weekly Update - LANSCE Neutron Spectrum Characterization

Preparations for characterizing the energy spectrum of the LANSCE neutron source have been made. The spallation neutron source at the Los Alamos Neutron Science Center (LANSCE) produces a white spectrum of neutrons with energies between about 100 keV to greater than 600 MeV. Recently, an effort to radiograph dense objects has been stood up at the Weapons Neutron Research (WNR) facility at LANSCE. However, the spallation process as well as some target-cooling techniques can create high gamma fluxes. The gamma- and neutron-energy spectrum of the source influence the quality of the radiographs that can be made with the source. Additionally, models of the source are essential to interpreting radiographs made with it, and experimental constraints on the gamma- and neutron-energy spectrum of the source will greatly increase the fidelity of these models. The gamma- and neutron-energy spectrum of the LANSCE source can be constrained in the ~10-MeV to ~100-MeV range through measurements of threshold reactions on bismuth foils. The decay of the activation products of the (n,Xn) and (γ,Xn) reactions can be measured, and, using the known cross sections for these reactions, the spectral content of the beam can be inferred. Many of these activation products decay via γ-ray emission, so measuring these decays requires High-Purity Germanium (HPGe) detectors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Interpretable boosted-decision-tree analysis for the Majorana Demonstrator

The Majorana Demonstrator is a leading experiment searching for neutrinoless double-beta decay with high purity germanium detectors (HPGe). Machine learning provides a new way to maximize the amount of information provided by these detectors, but the data-driven nature makes it less interpretable compared to traditional analysis. An interpretability study reveals the machine's decision-making logic, allowing us to learn from the machine to feedback to the traditional analysis. In this work, we have presented the first machine learning analysis of the data from the Majorana Demonstrator; this is also the first interpretable machine learning analysis of any germanium detector experiment. Two gradient boosted decision tree models are trained to learn from the data, and a game-theory-based model interpretability study is conducted to understand the origin of the classification power. By learning from data, this analysis recognizes the correlations among reconstruction parameters to further enhance the background rejection performance. By learning from the machine, this analysis reveals the importance of new background categories to reciprocally benefit the standard Majorana analysis. This model is highly compatible with next-generation germanium detector experiments like LEGEND since it can be simultaneously trained on a large number of detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Results of the LEGEND-200 experiment in the search for $0νββ$ decay

The LEGEND experiment is looking for the extremely rare neutrinoless double beta (0νββ) decay of 76 Ge using isotopically-enriched high-purity germanium (HPGe) detectors. The detection of this process would imply that the neutrino is a Majorana particle and the total lepton number would not be conserved, which could be related to the cosmological asymmetry between matter and antimatter through leptogenesis. The long-term goal of the collaboration is LEGEND-1000: a 1-ton detector array planned to run for 10 years, with a projected half-life sensitivity exceeding 10 28 years, fully covering the inverted neutrino mass hierarchy. A first search for the 0νββ decay has been carried out by LEGEND-200 building on the experience gained from GERDA and the MAJORANA DEMONSTRATOR. The experiment has been collecting physics data for a year at the Gran Sasso National Laboratory in Italy with 140 kg of HPGe detectors. With a total exposure of 61 kg yr, LEGEND-200 has achieved a background index of $5_{−2}^{+3}$ × 10 −4 counts/(keV kg yr) in the 0νββ decay signal region from the highest performing detectors. After combining the results from GERDA, the MAJORANA Demonstrator and LEGEND-200, an exclusion sensitivity > 2.8 × 10 26 yr has been obtained at 90% confidence level for the 0νββ decay half-life, with no evidence for a signal. A new observed lower limit of $T_{1/2}^{0v} >$ 1.9 × 10 26 yr at 90% confidence level has been established.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modified Bridgman anvils for high pressure synthesis and neutron scattering

A simple modified Bridgman design for large volume pressure anvils usable in the Paris-Edinburgh (PE) press has been demonstrated at Oak Ridge National Laboratory Spallation Neutron Source. The design shows advantages over the toroidal anvils typically used in the PE press, mainly rapid compression/decompression rates, complete absence of blow-outs upon drastic phase transitions, simplified cooling, high reliability, and relative low loads (~40 tons) corresponding to relatively high pressures (~20 GPa). It also shows advantages over existing large-volume diamond cells as sample volumes of ~2-3 mm 3 can be easily and rapidly synthesized. The anvils thus allow sample sizes sufficient for in situ neutron diffraction as well as rapid synthesis of adequate amounts of new materials for ex situ analysis via total neutron scattering and neutron spectroscopy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Single Event Transient Response of Vertical and Lateral Waveguide-Integrated Germanium Photodiodes

Pulsed-laser induced single event current measurements on two geometries of waveguide-integrated germanium photodiodes were conducted over a range of operating voltages to examine the impact of photodiode geometry on the transient response. Vertical PIN photodiodes exhibit transients with a duration that is relatively independent of the operating voltage while the transient duration in lateral PIN photodiodes depends on operating voltage. Furthermore, the experimental measurements facilitate identification of device dimensions that impact the transient response. In this work, these results can be used to identify potential radiation mitigation strategies for photodiodes operating in a radiation environment. Understanding the implications of design choices is critical for designing integrated photonic systems that balance system performance with tolerance for radiation degradation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Remediating neutron damage in large area planar Ge-DSSD with amorphous germanium contacts through annealing and pulse-height correction

Large area, position sensitive planar germanium detectors offer new opportunities in -ray spectroscopy. For in-beam studies remediating neutron damage is important. This work studied a mechanically cooled circular planar 9 × 1 cm wafer with orthogonal 16 × 16 amorphous germanium strip electrodes. Before neutron irradiation the wafer was heated in-cryostat to above 373 K for more than 24 h in order to test the robustness of the contacts and the mechanical cooler. No deterioration in performance was observed. The detector was then exposed to controlled doses of 2.2 MeV neutrons, produced from the 7 Li(p,n) 7 Be reaction until substantial damage was observed. Averaged over the surface of the wafer, a flux of 1.9(1) x 10 9 n/cm 2 was delivered. The detector then survived thermal cycling and 350 K (~77°C) annealing for 70 h which substantially reduced hole trapping. pulse-height correction is investigated to further mitigate the neutron damage. Higher temperature annealing at 365 K was not successful.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A fi eld-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt gamma-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium gamma-ray detector. Fine spatial resolution neutron and alpha detectors enable precise mapping of characteristic gamma-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus signifi cantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Total Ionizing Dose Effects on Strained Ge pMOS FinFETs on Bulk Si

In this paper, we have characterized the total ionizing dose response of strained Ge p MOS FinFETs built on bulk Si using a fin replacement process. Devices irradiated to 1.0 Mrad(SiO 2 ) show minimal transconductance degradation (less than 5%), very small V th shifts (less than 40 mV in magnitude) and very little ON/OFF current ratio degradation (<5%), and only modest variation in radiation response with transistor geometry (typically less than normal part-to-part variation). Both before and after irradiation, the performance of these strained Ge p MOS FinFETs is far superior to that of past generations of planar Ge p MOS devices. Finally, these improved properties result from significant improvements in processing technology, as well as the enhanced gate control provided by the strained Ge FinFET technology.

10 keV X-ray↗

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A fi eld-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt gamma-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium gamma-ray detector. Fine spatial resolution neutron and alpha detectors enable precise mapping of characteristic gamma-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus signifi cantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

First measurement of 60 Ge $\beta$-decay

Here, the N = 28 isotone 60 Ge, T z = –2, was produced and selected among the products of the fragmentation reaction of a 78 Kr beam at 150 MeV/nucleon and a Be target by means of the A1900 fragment separator at the National Superconducting Cyclotron Laboratory (NSCL) at Michigan State University (MSU). Its decay was studied for the first time using the optical time projection chamber. The β-decay of 60 Ge was found to be dominated by β-delayed proton emission, with a branching of ≈100% and half-life T 1/2 = 20 +7 –5 ms.

60Ge Event↗

$$\alpha $$-event characterization and rejection in point-contact HPGe detectors

Abstract P-type point contact (PPC) HPGe detectors are a leading technology for rare event searches due to their excellent energy resolution, low thresholds, and multi-site event rejection capabilities. We have characterized a PPC detector’s response to $$\alpha $$ α particles incident on the sensitive passivated and p $$^+$$ + surfaces, a previously poorly-understood source of background. The detector studied is identical to those in the Majorana Demonstrator experiment, a search for neutrinoless double-beta decay ( $$0\nu \beta \beta $$ 0 ν β β ) in $$^{76}$$ 76 Ge. $$\alpha $$ α decays on most of the passivated surface exhibit significant energy loss due to charge trapping, with waveforms exhibiting a delayed charge recovery (DCR) signature caused by the slow collection of a fraction of the trapped charge. The DCR is found to be complementary to existing methods of $$\alpha $$ α identification, reliably identifying $$\alpha $$ α background events on the passivated surface of the detector. We demonstrate effective rejection of all surface $$\alpha $$ α events (to within statistical uncertainty) with a loss of only 0.2% of bulk events by combining the DCR discriminator with previously-used methods. The DCR discriminator has been used to reduce the background rate in the $$0\nu \beta \beta $$ 0 ν β β region of interest window by an order of magnitude in the Majorana Demonstrator and will be used in the upcoming LEGEND-200 experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low-energy enhancement in the γ -ray strength functions of Ge 73 , 74

Here, t≤he γ-ray strength functions and level densities of 73,74 Ge have been extracted up to the neutron-separation energy S n from particle-γ coincidence data using the Oslo method. Moreover, the γ-ray strength function of 74 Ge above S n has been determined from photoneutron measurements; hence these two experiments cover the range of Eγ ≈ 1–13 MeV for 74 Ge. The obtained data show that both 73,74 Ge display an increase in strength at low γ energies. The experimental γ-ray strength functions are compared with M1 strength functions deduced from average B(M1) values calculated within the shell model for a large number of transitions. The observed low-energy enhancements in 73,74 Ge are adopted in the calculations of the 72,73 Ge(n,γ) cross sections, where there are no direct experimental data. Calculated reaction rates for more neutron-rich germanium isotopes are shown to be strongly dependent on the presence of the low-energy enhancement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2016 NIST ( 133 Xe) and Transfer ( 131m Xe, 133m Xe, 135 Xe) Calibration Report

A significantly improved calibration of the High Purity Germanium detectors used by the Idaho National Laboratory Noble Gas Laboratory was performed during the annual NIST calibration. New sample spacers provide reproducible and secure support of samples at distances of 4, 12, 24, 50 and 100 cm. Bean, 15mL and 50mL Schlenk tube geometries were calibrated. Also included in this year’s calibration was a correlation of detector dead-time with sample activity that can be used to predict the schedule of counting the samples at each distance for each geometry. This schedule prediction will help staff members set calendar reminders so that collection of calibration data at each geometry will not be missed. This report also correlates the counting efficiencies between detectors, so that if the counting efficiency on one detector is not known, it can be estimated from the same geometry on another detector.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

High-precision measurements of half-lives for 69 Ge, 73 Se, 83 Sr, 85 mSr, and 63 Zn radionuclides relevant to the astrophysical p-process via photoactivation at the Madison Accelerator Laboratory

The ground state half-lives of 69 Ge, 73 Se, 83 Sr, 63 Zn, and the half-life of the 1/2 - isomer in 85 Sr have been measured with high precision using the photoactivation technique at an unconventional bremsstrahlung facility that features a repurposed medical electron linear accelerator. The γ -ray activity was counted over about 6 half-lives with a high-purity germanium detector, enclosed into an ultra low-background lead shield. The measured half-lives are: T 1/2 ( 69 Ge) = 38.82 ± 0.07 (stat) ± 0.06 (sys) h; T 1/2 ( 73 Se) = 7.18 ± 0.02 (stat) ± 0.004 (sys) h; T 1/2 ( 83 Sr) = 31.87 ± 1.16 (stat) ± 0.42 (sys) h; T 1/2 ( 85m Sr) = 68.24 ± 0.84 (stat) ± 0.11 (sys) min; T 1/2 ( 63 Zn) = 38.71 ± 0.25 (stat) ± 0.10 (sys) min. These high-precision half-life measurements will contribute to a more accurate determination of corresponding ground-state photoneutron reaction rates, which are part of a broader effort of constraining statistical nuclear models needed to calculate stellar nuclear reaction rates relevant for the astrophysical p -process nucleosynthesis.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Crystal Growth and Detector Development for Underground Experiments

Cosmogenic production in germanium crystals grown on the surface can limit the sensitivity for the next generation deep underground experiments in searching for rare event physics beyond the Standard Model. One of the best solutions to eliminate unwanted cosmogenics is to produce the germanium crystals and detectors in an underground environment. The goal of this project is to create state-of-the-art detectors to advance neutrinoless double-beta decay and dark matter exploration research and technology while simultaneously paving the way for infrastructure to support an underground laboratory for zone refining, crystal growth, and detector fabrication at the Sanford Underground Research Facility. The greatest challenge in the growth of germanium crystals is a lack of precise control of individual crystal properties such as the impurity distribution, the dislocation density, and the crystalline structure. With knowledge gained from the pioneers in the field of crystal growth, the researchers have developed a novel technique to grow detector-grade crystals in South Dakota.

36 MATERIALS SCIENCE↗