Search NASA⌕ Search

SEARCH · Search NASA

Results for “GERMANIUM 82”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Nuclear Data Sheets for A=82☆

The evaluators present in this publication spectroscopic data and level schemes from radioactive decay and nuclear reactions studies for all isobars, Z=28(Ni) to Z=42(Mo), with mass number A=82. For {sup 82}Ni not much is known other than its identification. Most of the new data, i.e., after the last NDS (2003Tu03), are based on compilations included in XUNDL. Contributions of the various compilers in XUNDL are gratefully acknowledged.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Double-beta decay investigation with highly pure enriched $^{82}$Se for the LUCIFER experiment

The LUCIFER project aims at deploying the first array of enriched scintillating bolometers for the investigation of neutrinoless double-beta decay of 82 Se. The matrix which embeds the source is an array of ZnSe crystals, where enriched 82 Se is used as decay isotope. The radiopurity of the initial components employed for manufacturing crystals, that can be operated as bolometers, is crucial for achieving a null background level in the region of interest for double-beta decay investigations. In this work, we evaluated the radioactive content in 2.5 kg of 96.3 % enriched 82 Se metal, measured with a high-purity germanium detector at the Gran Sasso deep underground laboratory. The limits on internal contaminations of primordial decay chain elements of 232 Th, 238 U and 235 U are respectively: <61, <110 and <74 μBq/kg at 90 % C.L. The extremely low-background conditions in which the measurement was carried out and the high radiopurity of the 82 Se allowed us to establish the most stringent lower limits on the half-lives of the double-beta decay of 82 Se to 0+1, 2+2 and 2+1 excited states of 82 Kr of 3.4•10 22 , 1.3•10 22 and 1.0•10 22 y, respectively, with a 90 % C.L.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent to incoherent cross section ratio for 59.54 keV gamma rays at scattering angle of 110°

The coherent (Rayleigh) to incoherent (Compton) scattering cross-section ratio of elements, in the range 13 ≤ Z ≤ 82, are determined experimentally for 59.54 keV incident gamma photons. An HPGe (High purity germanium) semiconductor detector is employed, at scattering angle of 110°, to record the spectra originating from interactions of incident gamma photons with the target under investigation. The intensity ratio of Rayleigh to Compton scattered peaks observed in the recorded spectra, and corrected for photo-peak efficiency of gamma detector and absorption of photons in the target and air, along with the other required parameters provides the differential cross-section ratio. The measured values of cross-section ratio are found to agree with theoretical predictions based upon non-relativistic form factor, relativistic form factor, modified form factor and S-matrix theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Boron nitride: Composition, optical properties and mechanical behavior

A low energy ion beam deposition technique was used to grow boron nitride films on quartz, germanium, silicon, gallium arsenide, and indium phosphate. The film structure was amorphous with evidence of a hexagonal phase. The peak boron concentration was 82 at %. The carbon and oxygen impurities were in the 5 to 8 at % range. Boron-nitrogen and boron-boron bonds were revealed by X-ray photoelectron spectroscopy. The index of refraction varied from 1.65 to 1.67 for films deposited on III-V compound semiconductors. The coefficient of friction for boron nitride in sliding contact with diamond was less than 0.1. The substrate was silicon.

Pouch, John J.↗

Boron nitride - Composition, optical properties, and mechanical behavior

A low energy ion beam deposition technique was used to grow boron nitride films on quartz, germanium, silicon, gallium arsenide, and indium phosphate. The film structure was amorphous with evidence of a hexagonal phase. The peak boron concentration was 82 at. percent. The carbon and oxygen impurities were in the 5 to 8 at. percent range. Boron-nitrogen and boron-boron bonds were revealed by X-ray photoelectron spectroscopy. The index of refraction varied from 1.65 to 1.67 for films deposited on III-V compound semiconductors. The coefficient of friction for boron nitride in sliding contact with diamond was less than 0.1. The substrate was silicon.

Pouch, John J.↗

SU-F-I-56: High-Precision Gamma-Ray Analysis of Medical Isotopes

Purpose: Advanced, time-resolved, Compton-suppressed gamma-ray spectroscopy with germanium detectors is implemented for assaying medical isotopes to study the radioactive decay process leading to a more accurate appraisal of the received dose and treatment planning. Lowell’s Array for Radiological Assay (LARA), a detector array that is comprised of six Compton-suppressed high-purity germanium detectors, is currently under development at UMass-Lowell which combines Compton-suppression and time-and-angle correlations to allow for highly efficient and highly sensitive measurements. Methods: Two isotopes produced Brookhaven Linac Isotope Producer (BLIP) were investigated. {sup 82}Sr which is the parent isotope for producing {sup 82}Rb is often used in cardiac PET. {sup 82}Sr gamma-ray spectrum is dominated by the 511keV photons from positron annihilation which prevent precise measurement of co-produced contaminant isotopes. A second project was to investigate the production of platinum isotopes. Natural platinum was bombarded with protons from 53MeV to 200MeV. The resulting spectrum was complicated due to the large number of stable platinum isotopes in the target, the variety of open reaction channels (p,xn), (p,pxn), (p,axn). Results: By using face-to-face NaI(Tl) counters 90-degrees to the Compton-suppressed germaniums to detect the 511keV photons, a much cleaner and more sensitive measurement of {sup 85}Sr and other contaminants was obtained. For the platinum target, we identified the production of {sup 188–189–191–195}Pt, {sup 191–192–193–194–195–196}Au and {sup 186–188–189–190–192–194–189–190–192–194}Ir. For example, at the lower energies (53 and 65MeV), we measured {sup 191}Pt production cross-sections of 144mb and 157mb. Considerable care was needed in following the process of dissolving and diluting the samples to get consistent results. The new LARA array will help us better ascertain the absolute efficiency of the counting system and more reliable production cross-sections. Conclusion: Modern HPGe spectroscopic techniques provide enhanced sensitivity, promising precise quantification of the quality of radioisotopes used in medical physics. Using new decay information may have non-trivial impact on treatment planning and dose-assessment.

07 ISOTOPE AND RADIATION SOURCES↗

Search for 0ν2β of {sup 100}Mo by NEMO-3 and status of SuperNEMO

The NEMO-3 experiment was devoted to the research of the neutrinoless double beta decay and the precise measurement of the two-neutrino double beta decay of seven isotopes. The detector took data in the Laboratoire Souterrain de Modane (LSM) from 2003 to 2011. The unique combination of a 3D-tracker and a calorimeter allowed to fully reconstruct the double beta decay events topology and strongly reduces the backgrounds. This feature also permitted to characterize the remaining backgrounds in independent analysis channels. With an exposure of 34.7 kg·y of {sup 100}Mo no evidence for the 0ν2β signal has been found, yielding a limit for the light Majorana neutrino mass mechanism of T{sub 1/2}(0ν2β) > 1.1 10{sup 24} years (90 % C.L.) once both statistical and systematic uncertainties are taken into account. Depending on the Nuclear Matrix Elements this corresponds to an upper limit on the Majorana effective neutrino mass of |m{sub ββ}| < 0.3 − 0.9 eV (90 % C.L.). Constraints on other lepton number violating mechanisms of 0ν2β decays are also given. Searching for high-energy double electron events in all suitable sources of the detector, no event in the energy region [3.2-10] MeV is observed for an exposure of 47 kg·y. The next generation experiment, SuperNEMO, will use the same experimental technique to extend the sensitivity on the neutrinoless double beta decay search. Several aspects have been improved compared to NEMO-3: choice of the isotope, energy resolution, energy losses… but the main challenge is the background reduction. All the detector materials have been selected for their low natural radioactivity contaminations through High Purity Germanium (HPGe) gamma spectroscopy. The double beta sources after enrichment are being prepared with extreme care and the ultimate contaminations will be characterized by the most sensitive BiPo detector. External radon tightness and internal radon emanation have been studied to ensure a very low level in the tracker with very sensitive complementary detectors: diffusion apparatus, concentration line and emanation tanks. The construction of the first detector, called the demonstrator, has started in 2012. Studying 7 kg of {sup 82}Se, the demonstrator will reach the NEMO-3 sensitivity in only 5 months and improve it by at least a factor 6 in 2.5 years. Underground installation will start fall 2014 and physics data taking should start by summer 2015.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improved Cumulative Fission Yield Measurements with Fission Spectrum Neutrons on 238U

Two isotopically-characterized targets of high-purity (99.961±0.002%) 238U metal and a neutron dosimetry package were exposed to a pulsed neutron irradiation using the Godiva IV critical assembly at the National Criticality Experiments Research Center to measure the integral fission product yields produced in a Watt fission neutron-energy spectrum. Following irradiation, the fissioned targets were counted with two broad energy germanium detectors. Estimates of the total fissions for each target were made using measurements of well-known fission products. The total number of fissions in each target were then used to measure the fission yields of 33 fission products, 18 of which are published as new measurements. Twelve of the 18 isotopes were in agreement with ENDF/B- VIII.0 using the zeta test and treating ENDF/B-VIII.0 as the true mean: 84mBr, 93Y, 94Y, 104Tc, 134I, 135I, 138Xe, 141Ba, 142Ba, 142La, 146Ce, and 149Nd. The ENDF/B-VIII.0 fission yield for 139Ba was only slightly outside of 1-s relative to the uncertainty measured in this work. Uncertainties for 5 fission product yields were markedly improved over those reported in ENDF/B-VIII.0: 128Sn, 129Sb, 130gSb, 131mTe, and 133I. The fission yields measured for 128Sn, 131mTe, and 133I were in good agreement with the ENDF/B-VIII.0 predicted fission yields. However, fission yields measurements of the isotopes 129Sb, and 130gSb deviated from the ENDF/B-VIII.0 value. Both of these isotopes reside near the doubly magic nuclear shell closures of 50 protons and 82 neutrons. These fission yields may be suppressed because of the odd-odd nuclear structure of 130gSb and the odd-even structure of 129Sb and isomer splitting. Comparisons to other recent work and a brief review with citations are included to support this conclusion.

Fission Yields↗