Summary of GFL Inverter Capability and Performance: Malawi [Slides]

This presentation provides a comprehensive comparison of inverter-based resource (IBR) technical requirements across multiple international grid codes - including IEEE 2800, ESO, EirGrid, and Malawi's evolving regulatory framework - to support capacity building for electricity-sector institutions in Malawi. It highlights key performance expectations for grid-following (GFL) inverters across critical domains such as primary and fast frequency response, ramping behavior, frequency and voltage ride-through capabilities, reactive power and voltage control, ROCOF withstand, phase jump tolerance, system strength considerations, protection schemes, and dynamic modeling requirements. Emphasizing a "Do no harm, do something, do more" philosophy, the document synthesizes best practices and operational benchmarks to guide the integration and stability of inverter-based resources within Malawi's power system. The presentation forms part of the SABESS Center of Excellence initiative supported by the Global Energy Alliance for People and the Planet.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Per-phase Phasor Modeling of GFL and GFM Inverters for Distribution System Dynamic Studies

A significant increase in inverter-based distributed energy resources (DERs) is expected in the near future. Existing electromagnetic models and sequential electromechanical models of DERs supporting dynamic analysis cannot be extended to largescale three-phase distribution systems usually with unbalanced construction. As such, there is a need for appropriate industry models that can support distribution system dynamic studies. This paper describes the latest phasor models of grid-following (GFL) and grid-forming (GFM) inverters that can capture distribution system dynamics under grid disturbances. The overall modeling performance is examined and compared with results from other platforms such as controller hardware-in-the-loop (CHIL), MATLAB/Simulink and PSCAD with electromagnetic transient (EMT) and/or phasor simulation capabilities under balanced and unbalanced faults.

Distribution system, Grid modelling, GridLAB-D, Po↗

Testing GFM and GFL Inverters Operating With Synchronous Condensers

Inverter-based resources (IBRs) are quickly evolving into a source of reliability services to the electric grid. Penetration levels of variable generation are rapidly increasing, ranging from 60% -70% in some systems. To go further, a fundamental shift is required to address challenges associated with grid stability. Synchronous condensers (SCs) are considered an important complementary technology in such transitions. This paper provides one-of-a-kind insights into real experimental results from operating a real MW-scale system consisting of a 2.2-MVA grid-forming (GFM) and grid-following (GFL) battery energy storage system, 2.5-MVA SCs, and a 3-MVA load bank operating as a small, islanded grid. Challenges that are expected in larger systems were mimicked in this small but real system to demonstrate seamless transitions from one mode to another as well as stable operation with different combinations of GFM and GFM resources, including a "loss of last synchronous generator" case. The experimental results presented in this paper are a valuable resource to everyone involved in developing and validating models or developing controls of power systems consisting of inverters and synchronous condensers.

grid-following converter↗

Decentralized Distribution System Restoration with Grid-Forming/Following Inverter-Based Resources

The high penetration of distributed energy resources (DERs) in active distribution systems has posed challenges to the centralized distribution system restoration (DSR) strategies in current practice. On the other hand, the advancement in smart inverter technologies enables the bottom-up restoration capability. This paper is motivated to develop a 3-layered hierarchical framework for decentralized DSR, based on the grid-forming (GFM) and grid-following (GFL) grid-edge inverters. The first layer presents the tertiary control, which determines the load pickup schedule and generation dispatch of DERs, using the alternating direction method of the multipliers algorithm. The second layer consists of two control functions: GFM control, which regulates voltage and frequency, establishing a stable grid for GFL inverters to follow; and GFL control, which regulates the real and reactive power. In the third layer, the primary control is proposed to regulate the inverter voltage and current, which is developed based on the virtual oscillator control (VOC). Furthermore, the developed framework is tested in the modified IEEE 13-node test feeder. Two scenarios of grid-connected and islanded operating modes are designed, and simulation results demonstrate the effectiveness of decentralized DSR strategies for controlling grid-edge inverters to enhance the distribution system resilience.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Study of Inverter Control Strategies on the Stability of Microgrids Toward 100% Renewable Penetration: Preprint

This paper investigates microgrid transient stability with mixed generation - synchronous generator (SG), grid-forming (GFM) and grid-following (GFL) inverters - under increasing penetration levels toward a 100% renewable generation microgrid. Specifically, the dynamics of a microgrid with an SG and GFL inverter(s), an SG with GFM inverter(s), and an SG with GFM and GFL inverters under each penetration are evaluated with an electromagnetic transient study with two critical dynamic events: unplanned islanding and switching in a pumped induction motor load. Analysis and simulation results indicate that the microgrid with GFL inverters running in parallel with the SG can provide a faster power response than the GFM inverters to compensate for the deviations of the frequency and voltage. The scenario with the mixed SG, GFM, and GFL inverter has the best transient and steady-state stability toward 100% inverter-based resource (IBR) penetration. This comprehensive study provides helpful references for microgrid engineers to understand the microgrid stability when facing various choice of installing IBRs (GFL, GFM, or mixed).

droop control↗

Study of Inverter Control Strategies on the Stability of Microgrids Toward 100% Renewable Penetration

This paper investigates microgrid transient stability with mixed generation - synchronous generator (SG), grid-forming (GFM) and grid-following (GFL) inverters - under increasing penetration levels toward a 100% renewable generation microgrid. Specifically, the dynamics of a microgrid with an SG and GFL inverter(s), an SG with GFM inverter(s), and an SG with GFM and GFL inverters under each penetration are evaluated with an electromagnetic transient study with two critical dynamic events: unplanned islanding and switching in a pumped induction motor load. Analysis and simulation results indicate that the microgrid with GFL inverters running in parallel with the SG can provide a faster power response than the GFM inverters to compensate for the deviations of the frequency and voltage. The scenario with the mixed SG, GFM, and GFL inverter has the best transient and steady-state stability toward 100% inverter-based resource (IBR) penetration. This comprehensive study provides helpful references for microgrid engineers to understand the microgrid stability when facing various choice of installing IBRs (GFL, GFM, or mixed).

droop control↗

Unified Universal Control and Coordination of Inverter-Based Resources, and Validation for a PV + Battery Hybrid Plant

As renewable energy deployment grows, hybrid power plants (HPPs) combining photovoltaic (PV) and battery systems must evolve to offer both energy and grid stability services. These systems typically include a mix of grid-following (GFL) and grid-forming (GFM) inverters, presenting unique coordination and control challenges. This Department of Energy–funded project developed and validated a Unified Universal Control and Coordination (UUCC) framework for such PV + battery hybrid plants, enabling seamless and stable operation, including ultrafast black start, autonomous synchronization, and robust frequency and voltage regulation, under different grid conditions. The project significantly advanced the understanding of inverter-based resource (IBR) control by developing and validating three complementary system-level approaches for hybrid GFL/GFM operation: 1. A combined Virtual Resistance (VR)-based GFL and Virtual Oscillator Control (VOC)-based GFM method, where each inverter type is governed by a specialized control strategy. Together, these achieve stable, fast-response coordination, eliminating inrush current and enabling smooth black start and grid synchronization across a wide range of grid strengths. 2. A Deadbeat-based UUCC strategy, which uses discrete-time, switching-cycle-level control for both GFL and GFM inverters. This approach replaces traditional PI/PLL control with a control parameter-free, high-bandwidth framework that supports stable LVRT and instantaneous synchronization under all conditions. 3. A benchmark comparison with Siemens’ commercial GFM microgrid controller, which provided a fast baseline platform. The commercial approach decoupled v & f control was implemented on a commercial microgrid controller.The baseline commercial benchmark helped highlight superior transient response and black start performance offered by the deadbeat and VOC approaches. These technical contributions offer substantial improvements over conventional inverter control schemes, which often rely on slow phase-locked loop (PLL)-based synchronization, require careful control parameters tuning, and prone to unstable in weak grids with GFL inverters and in stiff grid with GFM inverters therefore challenging for hybrid GFL+GFM under all grid conditions. The deadbeat-based UUCC framework enables simpler, faster, and more robust operation of hybrid IBR systems using wide-bandgap (WBG) devices such as SiC power semiconductors. The rapid expansion of hybrid distributed energy resources (DERs), including residential and commercial PV-BESS installations such as Tesla Powerwall, PV with vehicle-to-grid (V2G) capability, and other integrated configurations, presents complex operational challenges for medium-voltage radial distribution feeders. These networks are subject to frequent disturbances such as faults, switching operations, rapid reclosing sequences, and feeder reconfigurations, all of which introduce dynamic stress on IBRs. In addition, planned feeder segmentation and deliberate islanding for resilience will require DERs that can autonomously perform blackstart, establish voltage and frequency references, and resynchronize with the main grid. The advanced deadbeat-based UUCC control and blackstart functionalities developed in this project directly address these requirements, enabling decentralized and autonomous operation of inverter-dominated DERs in distribution systems under a wide range of fault and reconfiguration scenarios. From a public benefit perspective, these innovations enable more reliable and cost-effective integration of renewable energy into distribution networks. The ability to autonomously black start and stabilize grids under varying grid conditions support accelerates recovery from outages and support decentralized resilient energy systems. By reducing system complexity and improving performance, this project lays critical groundwork for future inverter-dominated power grids that are clean, reliable, and accessible to all.

14 SOLAR ENERGY↗

Grid Forming Control Tuning for a Hybrid Inverter-Based Resource Power Plant

A hybrid inverter-based resource (IBR) power plant consists of grid-following (GFL) and grid-forming inverter-based resources (GFM-IBR) connected in parallel. Here, this research focuses on how to design and tune GFM's control parameters to ensure stable operation of the hybrid power plant for weak and strong grid conditions. We consider two design cases: one where the GFL-IBR does not provide frequency support, and one where it does. It is found that the GFM's power-frequency synchronizing system can lose stability when the power-frequency droop constant is large and/or the grid is strong. Additionally, if the GFL has its frequency support enabled, oscillation stability worsens. To explain the mechanism of the interactions, we construct a feedback system for the synchronizing loop, which consists of the GFM's power-frequency droop control that generates the GFM's synchronizing angle, the GFL's phase-locked loop that measures the voltage phase angle, the GFL's frequency-power control that generates its power order, and the rest of the system. The feedback system is effective in illustrating the potential stability risks. Successful design ensures that the hybrid power plant can operate smoothly and ride through grid disturbances.

feedback systems↗

A Universal Controller for Grid-Forming Inverters in Microgrid during Islanding for Low Transient Current

This paper presents a universal controller to reduce the transient current during islanding of microgrid. In the proposed universal controller, two sets of semi-parallel paths are formed, where one set produces voltage and phase-angle references for the grid-following (GFL) mode, and the other set produces the voltage and phase-angle references for the grid-forming (GFM) mode of operation for the inverters. Herein, the controller enables an inverter to universally operate in GFL and GFM mode, whereas, only one set of voltage and phase-angle reference is engaged for PWM signal generation. When the microgrid is disconnected from the grid, the universal controller switches the voltage and phase-angle references from GFL to GFM mode. The proposed controller ensures lower transient current by keeping the two sets of semi-parallel paths synchronized throughout the operation of the inverter and enabling seamless transition between the modes. The proposed controller is verified through hardware experiments under different scenarios in a laboratory scale microgrid for inverters transitioning from GFL to GFM mode after islanding.

Sadeque, Fahmid↗

Peer-to-peer Communication Control Architecture for Engaging Ubiquitous DERs to Support Distribution System Resiliency

In this project, we developed a leader-follower consensus (LFC) control architecture to coordinate between GFM and GFL inverters with the former being leaders and the latter being followers. The objective is to simultaneously achieve a fast frequency and voltage regulation along with accurate real power and var sharing among all inverters under various disturbances. The distinction of our work is that we consider both GFM and GFL inveters for frequency and voltage regulations. In addition, rather than a standard consensus algorithm, our work utilized a leader-follower consensus algorithm which exploits the physical characteristics of GFM-GFL inverters: (i) the GFM inverters directly control frequency and voltage, and hence, serve as leaders, (ii) the GFL inverters measure frequency/voltage to modulate their outputs, and hence, they should serve as followers. The effectiveness of the proposed LFC coordination was tested on a networked microgrid test system under different disturbances and communication degradation events. We demonstrated that the proposed fully coordinated control is robust to disturbances, while outperforming uncoordinated and GFM-only coordinated approaches. Overall, this work emphasized the necessity and benefits of the GFMGFL coordination in the secondary control of microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Small Hydro Power Plants with Integrated BESS for Enhance Resiliency

Battery energy storage systems (BESS) are an important asset for power systems with high integration levels of renewable energy, and they can be controlled to provide various services to the grid. This paper presents the hardware demonstration and characterization of using a utility-scale BESS with grid-following (GFL) and grid-forming (GFM) controls and a run-of-river (ROR) hydropower plant to perform a bottom-up power system black start that enhances power systems' resiliency. ROR hydropower plants are generally not used for power system restoration due to their frequency instability during islanded operation; however, BESS with droop control can provide critical damping to convert a ROR hydropower generator into a black start- capable unit. To demonstrate this, we carry out hardware experiments at the megawatt-scale integrating a synchronous generator driven by a dynamometer, an actual GFL/GFM BESS, a medium-voltage impedance network, and a load bank. The demonstration shows the different roles of BESS with GFL and GFM control in power system restoration. GFL BESS can suffer from high-frequency oscillations, even instability, depending on the droop control gain and loading condition. The results provide further insights for system operators on how GFL- or GFM controlled BESS can enhance grid stability and how hydro-BESS hybrids can operate as a black-start-capable unit. The presented experimental results are also a valuable resource to understand the different stability characteristics of real-world BESS with different control modes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Regional Power System Black Start with Run-of-river Hydropower Plant and Battery Energy Storage

Battery energy storage systems (BESSs) are an important asset for power systems with high integration levels of renewable energy, and they can be controlled to provide various critical services to the power grid. This paper presents the real-world experience of using a megawatt-scale BESS with grid-following (GFL) and grid-forming (GFM) controls and a run-of-river (ROR) hydropower plant to restore a regional power system. To demonstrate this, we carry out power-hardware-in-the-loop experiments integrating an actual GFL- or GFM-controlled BESS and a load bank. Both the simulation and experimental results presented in this paper show the different roles of GFL- or GFM-controlled BESS in power system black starts. The results provide further insight for system operators on how GFL- or GFM-controlled BESS can enhance grid stability and how an ROR hydropower plant can be converted into a black-start-capable unit with the support of a small-capacity BESS. The results show that an ROR hydropower plant combined with a BESS has the potential of becoming one of enabling elements to perform bottom-up black-start schemes as opposed to conventional bottom-down method, thus enhancing the system resiliency and robustness.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demonstration of Power System Black Start with Hydropower Generator and Battery Energy Storage: Preprint

Battery energy storage systems (BESS) are an important asset for power systems with high integration levels of renewable energy, and they can be controlled to provide various services to the grid. This paper presents the hardware demonstration and characterization of using a utility-scale BESS with grid-following (GFL) and grid-forming (GFM) controls and a run-of-river (ROR) hydropower plant to perform a bottom-up power system black start that enhances power systems' resiliency. ROR hydropower plants are generally not used for power system restoration due to their frequency instability during islanded operation; however, BESS with droop control can provide critical damping to convert a ROR hydropower generator into a blackstart- capable unit. To demonstrate this, we carry out hardware experiments at the megawatt-scale integrating a synchronous generator driven by a dynamometer, an actual GFL/GFM BESS, a medium-voltage impedance network, and a load bank. The demonstration shows the different roles of BESS with GFL and GFM control in power system restoration. GFL BESS can suffer from high-frequency oscillations, even instability, depending on the droop control gain and loading condition. The results provide further insights for system operators on how GFL- or GFMcontrolled BESS can enhance grid stability and how hydro-BESS hybrids can operate as a black-start-capable unit. The presented experimental results are also a valuable resource to understand the different stability characteristics of real-world BESS with different control modes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Region-Based Stability Analysis of Resilient Distribution Systems with Hybrid Grid-Forming and Grid-Following Inverters

In this paper, distribution system stability considering mixed grid-forming (GFM) and grid-following (GFL) inverters is discussed. A holistic small-signal model of the distribution feeder accommodating both GFM and GFL inverters is derived. In contrast to conventional point-by-point stability analysis, a region-based stability assessment approach is proposed and implemented to evaluate small-signal system stability with both GFM and GFL controls. Furthermore, to enhance the computational efficiency, an Artificial Intelligence (AI) assisted Kernel Ridge Regression (KRR) approach is developed to obtain the stability region boundary. Therefore, with the derived stability region, the impact of critical parameters on system stability is intuitively shown, and more importantly, the relationship between the maximum penetration level and the corresponding feasible range of the selected control parameters can be quantified. The proposed approach has been validated using MATLAB/Simulink.

grid-following↗

Inverter Controls for Smooth Transition Operation and Voltage Balancing of Networked Microgrids

With increasing penetrations of distributed energy resources (DERs), researchers have extensively studied the formation and networking of microgrids to improve reliability during distribution system outages. However, these operations might require DERs in the microgrids to switch between grid-following (GFL) and grid-forming (GFM) modes of operation. A smooth transition between the operation modes should be ensured to have a stable system operation and to avoid nuisance tripping. Additionally, as we network microgrids, inverter control schemes with voltage-balancing controls are needed for unbalanced distribution networks. This paper presents the design of a GFM and GFL capable inverter control scheme for reliable operation in networked microgrids with mechanisms for 1) smooth transition between the GFL and GFM modes, and 2) negative sequence voltage control for voltage balancing. Using electromagnetic transient (EMT) simulations, the control scheme is first tested on a simple two-source power system using a digital real-time simulator. Next, a real-world distribution feeder with unbalanced loading and multiple DERs is used to demonstrate stable operation during the networking of microgrids with voltage balance support.

distributed energy resources↗

Comparative Small-Signal Stability Analysis of Grid-Forming and Grid-Following Inverters in Low-Inertia Power Systems: Preprint

Inverter-based resources (IBRs) are gradually replacing conventional fossil energy in modern power systems, which could make the system susceptible due to insufficient inertia, especially when moving towards a 100% inverter-based power grid. Grid-forming (GFM) and grid-following (GFL) controls are two common inverter control algorithms. However, the corresponding stability issues along with a comparative study on low-inertia power systems should still be investigated. This paper focuses on small-signal stability and conducts a comprehensive analysis of GFM and GFL controls, with emphases on the interactions between synchronous generators and IBRs. The detailed modeling of GFM and GFL inverters, and synchronous generators (SGs) are established. The coupling mechanism of IBRs and SGs is then conducted through participation factor analysis. The impacts of critical parameters on system stability are finally identified. The theoretical analyses are validated through time-domain simulation in MATLAB/Simulink.

grid-following↗

Fault Contribution of Grid-Following and Grid-Forming Inverters Considering Generic Inverter Controls and Ride-through Requirements

Gradual transformation of the synchronous generator (SG)-dominated power systems to inverter-based resource (IBR)-dominated power systems is bringing new challenges regarding power system protection. Increasing IBR’s penetration will reduce the reliability of protection coordination, originally developed for SG-dominated power systems, potentially leading to less accurate calculation or even mis-operation. Thus, new protection schemes compatible with IBR-dominated power systems should be established. Prior to establishing the protection schemes, research on the fault contribution of generic IBR models should be conducted considering interconnection requirements. This paper conducts fault current contribution analysis of generic grid-following (GFL) and grid-forming (GFM) inverters considering interconnection requirements using an electromagnetic transient (EMT) simulation tool. To do this, EMT-based generic GFL models have been developed with the ride-through requirements from IEEE-1547 standards. In addition, the major functions of the generic models are explained. Then, the fault current analysis was conducted using GFL and GFM inverters in a single-inverter-infinite-bus system and a modified IEEE 34-node system considering different grid, fault, inverter control parameters.