Search NASA⌕ Search

SEARCH · Search NASA

Results for “GLOVES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

In-situ Detection of Glovebox Glove Degradation Prior to Glove Failure; Effects on Safety, Waste, and Operational Costs - 20402

Glovebox glove pressure decay leak testing and analysis of the data can greatly improve glovebox safety, minimize Transuranic (TRU) glove waste, and minimize operational cost. It is well known, the weakest point of containment on a glovebox is the glove. Mitigating unplanned openings in gloves is critical to minimizing operational and safety costs in glovebox operations. Mitigating unplanned glove openings due to glove failures will be discussed in this paper. The lack of an engineered solution to determine a gloves operational life in nuclear operations, has lead to use of theoretical and manual subjective methods to determine the life and safety of a glovebox glove. Whether the glove is inspected visually prior to use, or gloves are changed regularly to theoretically avoid failure, both the operators PPE and the room are being exposed to contamination, or un-necessary amounts of TRU glove waste are being generated. Millions of dollars yearly in operational costs are spent on glove failures due to loss of production, incident analysis, regulatory audits, clean up, and paperwork. In a nuclear application, a glove failure could contaminate an operator and laboratory, shut down the operation for weeks, potentially create a regulatory audit, and potentially create a media frenzy; the damages to the organization can be astronomical. Elimination of glove failures is possible by tracking glove material degradation and setting limits to allow glove change when it becomes necessary, prior to glove failure. Analytical pressure decay leak testing allows the detection of material degradation, and in turn the ability to limit operational glove failures. A German based company called MK Versuchsanlagen, e.K., has developed an advanced Glove Integrity Testing System. The system, with its use of proprietary RFID and special software technology, is unique in its capabilities. The system is capable to perform highly accurate regular glove testing on any size glovebox line in minimal time. The system records and can analyze a tremendous amount of system data that in turn can determine, for example, a safe glove change time prior to a glove material failure. This paper will show how an advanced Glove Integrity Testing System can detect glove material degradation and help determine a safe change point prior to glove failure. Pressure decay curves of new gloves and recorded effects of accelerated aging on the glove over time will be shown. The use of this technology in nuclear facilities can greatly improve glovebox operational safety, minimize glovebox glove TRU waste, and save organizations tremendous costs in downtime, clean up, documentation, and potential regulatory review. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A glove-likeability study of specially-treated gloves in the detonator manufacturing and packaging industry

We use hand gloves (hereafter referred to as gloves) in the detonator manufacturing and packaging operations. As part of a process improvement program, new glove formulations have been considered that lower the overall risk of detonator operations by reducing ergonomic injury factors. Gloves with a specially treated surface for extra grip and control are now commercially available and have been recommended for use in detonator operations. A Glove Likeability Study demonstrated that detonator manufacturing and packaging workers prefer gloves with a specially treated surface over currently approved gloves made from latex and nitrile formulations. Glove material compatibility tests indicate that the recommended gloves are as compatible if not more compatible as the currently approved gloves for working with secondary explosives. Thus, these gloves with a specially treated surface for extra grip and control are now available for tasks where sensitivity and fingertip control are crucial. Replacement of the current gloves with gloves with a specially treated surface improves the safety configuration of detonator manufacturing and packaging operations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Develop and Manufacture an Ergonomically Sound Glovebox Glove Report

Ergonomic injury and radiation exposure are two safety concerns for the Plutonium Facility at Los Alamos National Laboratory (LANL). This facility employs the largest number of gloveboxes (GB) at LANL with approximately 6000 gloves installed. The current GB glove design dates back to the 1960’s and is not based on true hand anatomy, revealing several issues: short fingers, inappropriate length from the wrist to finger webbing, nonexistent joint angles and incorrect thumb placement. These design flaws are directly related to elbow (lateral epicondylitis) and thumb (DeQuervain’s tenosynovitis) injuries. The current design also contributes to increased wear on the glove, causing unplanned glove openings (failures) which places workers at risk of exposure. An improved glovebox glove design has three significant benefits: 1) it will reduce the risk of injury, 2) it will improve comfort and productivity, and 3) it will reduce the risk of a glovebox failures. The combination of these three benefits has estimated savings of several million dollars. The new glove design incorporated the varied physical attributes of workers ranging from the 5 th percentile female to the 95th percentile male. Anthropometric hand dimensions along with current GB worker dimensions were used to develop the most comprehensive design specifications for the new glove. Collaboration with orthopedic hand surgeons also provided major contributtions to the design. The new glovebox glove was developed and manufactured incorporating over forty dimensions producing the most comprehensive ergonomically sound design. The new design received a LANL patent (patent attorney docket No: LANS 36USD1 “Protective Glove”, one of 20 highest patents awarded by the Richard P. Feynman Center for Innovation. The glove dimensions were inputed into a solid works model which was used to produce molds. The molds were then shipped to a glove manufacturer for production of the new glovebox gloves. The new glovebox gloves were tested against the presently used glovebox gloves for design validity. The testing included a subjective survey and four dexterity tests. The prototype was statistically significant in 3 dexterity tests and favorable on 8 out of 10 survey questions. The more ergonomically sound glovebox glove will improve worker comfort, mitigate glovebox worker injuries, and reduce glove breaches.

42 ENGINEERING↗

CHARACTERIZATION OF GLOVEBOX GLOVES FOR THE SAVANNAH RIVER SITE

A task was undertaken to characterize glovebox gloves that are currently used in the facilities at Savannah River Site (SRS) as well as some experimental and advanced compound gloves that have been proposed for use. Gloves from four manufacturers were tested for permeation in hydrogen and air, thermal stability, tensile properties, puncture resistance and dynamic mechanical response. The gloves were compared to each other within the type and also to the butyl rubber glove that is widely used at the SRS. The permeation testing demonstrated that the butyl compounds from three of the vendors behaved similarly and exhibited hydrogen permeabilities of .52‐.84 x10{sup ‐7} cc H{sub 2}*cm / (cm{sup 2}*atm). The Viton glove performed at the lower edge of this bound, while the more advanced composite gloves exhibited permeabilities greater than a factor of two compared to butyl. Thermogravimetric analysis was used to determine the amount of material lost under slightly aggressive conditions. Glove losses are important since they can affect the life of glovebox stripper systems. During testing at 90, 120, and 150°C, the samples lost most of the mass in the initial 60 minutes of thermal exposure and as expected increasing the temperature increased the mass loss and shortened the time to achieve a steady state loss. The ranking from worst to best was Jung butyl‐Hypalon with 12.9 %, Piercan Hypalon with 11.4 %, and Jung butyl‐Viton with 5.2% mass loss all at approximately 140°C. The smallest mass losses were experienced by the Jung Viton and the Piercan polyurethane. Tensile properties were measured using a standard dog bone style test. The butyl rubber exhibited tensile strengths of 11‐15 MPa and elongations or 660‐843%. Gloves made from other compounds exhibited lower tensile strengths (5 MPa Viton) to much higher tensile strengths (49 MPa Urethane) with a comparable range of elongation. The puncture resistance of the gloves was measured in agreement with an ASTM standard. The Butyl gloves exhibited puncture resistance from 183 - 296 lbs/in for samples of 0.020 - 0.038 thick. Finally, the glass transition temperature and the elastic and viscoelastic properties as a function of temperature up to maximum use temperature were determined for each glove material using Dynamic Mechanical Analysis. The glass transition temperatures of the gloves were ‐60°C for butyl, ‐30°C for polyurethane, ‐ 16°C Hypalon, ‐16°C for Viton, and ‐24°C for polyurethane‐Hypalon. The glass transition was too complex for the butyl‐Hypalon and butyl‐Viton composite gloves to be characterized by a single glass transition temperature. All of the glass transition temperatures exceed the vendor projected use temperatures.

42 ENGINEERING↗

Dexterity test data contribute to reduction in leaded glovebox gloves use

Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (T A-55) involve working with various amounts of plutonium and other highly toxic, alpha-emitting materials. The spread of radiological contamination on surfaces, airborne contamination, and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes. Using an integrated approach, controls have been developed and implemented through an efficient Glovebox Glove Integrity Program. A key element of this program is to consider measures that lower the overall risk of glovebox operations. Line management who own glovebox processes through this program make decisions on which type of glovebox gloves (hereafter referred to as gloves), the weakest component of this safety-significant system, would perform best in these aggressive environments. As Low as Reasonably Achievable considerations must be balanced with glove durability and worker dexterity, both of which affect the final overall risk of the operation. In the past, lead-loaded (leaded) gloves made from Hypalon(reg.) were the primary glove for programmatic operations at TA55. Replacing leaded gloves with unleaded gloves for certain operations would lower the overall risk as well as reduce the amount of mixed transuranic waste. This effort contributes to the Los Alamos National Laboratory Continuous Improvement Program by improving the efficiency, cost-effectiveness, and formality of glovebox operations. In this report, the pros and cons of wearing leaded gloves, the effect of leaded gloves versus unleaded gloves on task performance using standard dexterity tests, the justification for switching from leaded to unleaded gloves, and the pollution prevention benefits of this dramatic change in the glovebox system are presented.

42 ENGINEERING↗

Dexterity tests data contribute to reduction in leaded glovebox gloves use

Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (TA-55) involve working with various amounts of plutonium and other highly toxic, alphaemitting materials. The spread of radiological contamination on surfaces and airborne contamination and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes. Through an integrated approach, controls have been developed and implemented through an efficient Glovebox Glove Integrity Program (GGJP). A key element of this program is to consider measures that lower the overall risk of glovebox operations. Line management owning glovebox processes through this program make decisions on which type of glovebox gloves (the weakest component of this safety significant system) would perform in these aggressive environments. As Low As Reasonably Achievable (ALARA) considerations must be balanced with glove durability and worker dexterity, both of which affect the final overall risk of the operation. In the past, lead-loaded (leaded) glovebox gloves made from Hypalon(reg.) had been the workhorse of programmatic operations at TA-55. Replacing leaded gloves with unleaded gloves for certain operations would lower the overall risk as well as reduced the amount of mixed TRU waste. This effort contributes to Los Alamos National Laboratory Continuous Improvement Program by improving the efficiency, cost effectiveness, and formality of glovebox operations. In the following report, the pros and cons of wearing leaded glovebox gloves, the effect of leaded gloves versus unleaded gloves on task performance using standard dexterity tests, the justification for switching from leaded to unleaded gloves, and pollution prevention benefits of this dramatic change in the glovebox system are presented.

57↗

Dexterity test data contribute to proper glovebox over-glove use

Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (TA-55) involve working with various amounts of plutonium and other highly toxic, alpha-emitting materials. The spread of radiological contamination on surfaces, airborne contamination, and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes (the glovebox, coupled with an adequate negative pressure gradient, provides primary confinement). The glovebox gloves are the weakest part of this engineering control. The Glovebox Glove Integrity Program, which controls glovebox gloves from procurement to disposal at TA-55, manages this vulnerability. A key element of this program is to consider measures that lower the overall risk of glovebox operations. Proper selection of over-gloves is one of these measures. Line management owning glovebox processes have the responsibility to approve the appropriate personal protective equipment/glovebox glove/over-glove combination. As low as reasonably achievable (ALARA) considerations to prevent unplanned glovebox glove openings must be balanced with glove durability and worker dexterity, both of which affect the final overall risk to the worker. In this study, the causes of unplanned glovebox glove openings, the benefits of over-glove features, the effect of over-gloves on task performance using standard dexterity tests, the pollution prevention benefits, and the recommended over-gloves for a task are presented.

57↗

Evaluation of Glovebox Glove Material Integrity Under Thermal Insult (Final Report)

The results of the experiments presented above are summarized in Table 1. Timing of critical events, such as appearance of bubbles on the specimen surface and rupture are noted. Relevant temperature and pressure data are also summarized. These results indicate a few critical aspects of the response of Hypalon glove material when exposed to a high temperature environment. Glove specimens began to show changes in surface appearance (appearance of bubbles on surface) when the temperature at the specimen surface was 530 ± 32 °F, regardless of specimen thickness. The bubbles are likely the result of the glove material decomposing and off-gassing. In the case of the 15 mil thickness gloves, specimens ruptured shortly after bubbling was observed. The ruptures are likely the result the bubbles growing in size, eventually forming pinholes through the thickness of the specimen. It should be noted that the specimens did not need to ignite in order to cause a perforation of the specimen. Specimens located 10, 11 and 12 inches from the burner ruptured, while the specimen located 14 inches from the burner did not rupture; in fact no change in surface appearance was observed. The 30 mil thickness specimens exhibited a different post-bubble response with only the specimen located 10 inches from the burner (i.e. highest surface temperature) resulting in rupture. There was a longer delay between surface bubbling and rupture than was observed in the 15 mil thickness specimens. This specimen also ignited before the specimen ruptured. While the 30 mil thickness specimens located 11 and 12 inches from the burner did show surface bubbling corresponding to thermal breakdown, neither specimen ruptured. Examination of the specimens after testing revealed that a slightly hard layer of melted material had formed on the rear of the specimen. This layer may have acted to seal the rear surface of the specimen by forming a barrier that bubbles could not penetrate. The specimen located 14 inches from the burner did not rupture, and did not exhibit any change in surface characteristics. In general the 30 mil thickness glove materials proved more resistant to thermal-induced rupturing as compared with the 15 mil thickness glove material. It was shown to be possible to rupture a 15 mil thick glove without igniting the glove, while the only test case that resulted in a rupture of a 30 mil thickness specimen also showed the specimen igniting several seconds before eventual rupture. Furthermore, it was observed that 30 mil thickness specimens could be exposed to temperatures high enough to cause decomposition (bubbling), yet not rupture. Thus, it is possible that the 30 mil gloves rupture by burning through the specimen material, while the 15 mil thickness specimens could be ruptured by small bubbles formed by thermal off-gassing expanding and causing pinholes through the specimen thickness. We also note that thermal decomposition and the appearance of surface bubbles was observed in all experiments with a maximum temperature exceeding ∼500 °F. Lastly, we can state that specimens subjected to temperatures below 400 °F experienced no thermal damage, staying below this threshold should prevent damage and potential rupture of either thickness glove materials.

42 ENGINEERING↗

Dexterity and Worker Comfort in an Ergonomically Designed Glovebox Glove

Gloveboxes are prolifically used in nuclear facilities as the primary means of separation between the hazardous material and operators. Due to extended duration and high repetition of hand tasks in glovebox gloves, improperly fitting gloves can be uncomfortable and increase injury risks. Poor fit can increase time necessary to perform work tasks and stress the glove itself. The Plutonium Facility has the largest inventory of glovebox gloves at Los Alamos National Laboratory (LANL) with approximately 6000 gloves installed. The current glove mold dates back to the 1960's and is not based on the true anatomy of the hand. Design flaws (poor anatomical fit and biomechanics) are directly related to injuries of the elbow (lateral epicondylitis) and thumb (DeQuervain's tenosynovitis) injuries. The current design also contributes to 30% of unplanned glove openings. A new glovebox glove was developed and manufactured, incorporating over forty dimensions to produce the most comprehensive ergonomically sound design. The new design received a LANL patent (patent attorney docket No: LANS 36USD1 'Protective Glove'), one of 20 highest patents awarded by the Richard P. Feynman Center for Innovation. A SolidWorks model was given to the manufacturer for production of the glove mold.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of Glovebox Gloves for Effective Permeation Control

A research and development task was undertaken to determine the permeabilities of hydrogen and dry air through different polymeric glove materials that are used to maintain the integrity of glovebox secondary containment. Fifteen different glove samples were obtained from four different manufacturers and samples cut from these gloves were tested. The gloves included baseline butyl rubber, Viton * , Dupont * Hypalon * , polyurethane, as well as composite gloves. The testing indicated that all of the vendor's butyl rubber gloves and the Jung Viton * gloves performed comparably in both gases.

08 HYDROGEN↗

Interchangeable breech lock for glove boxes

A breech lock for a glove box is provided that may be used to transfer one or more items into the glove box. The breech lock can be interchangeably installed in place of a plug, glove, or other device in a port or opening of a glove box. Features are provided to aid the removal of items from the breech lock by a gloved operator. The breech lock can be reused or, if needed, can be replaced with a plug, glove, or other device at the port or opening of the glove box.

42 ENGINEERING↗

In-situ gloveport glove leak tester

The invention provides a system for detecting leaks in glovebox gloves, the system having a first seal within a glovebox aperture; a second seal contacting exterior surfaces of a glovebox, wherein the exterior surfaces define a periphery of the aperture; a first fluid supply for circumferentially expanding the first seal against center facing surfaces of the aperture to a first pressure; a second fluid supply for inflating the glove to a second pressure; and a pressure gauge for detecting a pressure decrease of the second pressure. Also provided is an in situ method for detecting leaks in glove box gloves, the method having the steps of applying a radially directed force to inside surfaces of cuffs of the gloves to hermetically seal the gloves from the exterior of the glovebox, thereby establishing a seal; inflating the gloves to a pressure; and monitoring the pressure for any decrease in pressure.

42 ENGINEERING↗

Characterization of Tensile Strength of Glovebox Gloves

A task was undertaken to compare various properties of different glovebox gloves, having various compositions, for use in gloveboxes at the Savannah River Site (SRS). One aspect of this project was to determine the tensile strength (TS) of the gloves. Longitudinal tensile samples were cut from 15 different gloves and tensile tested. The stress, load, and elongation at failure were determined. All of the gloves that are approved for glovebox use and listed in the glovebox procurement specification met the tensile and elongation requirements. The Viton * compound gloves are not listed in the specification, but exhibited lower tensile strengths than permissible based on the Butyl rubber requirements. Piercan Polyurethane gloves were the thinnest samples and exhibited the highest tensile strength of the materials tested.

36 MATERIALS SCIENCE↗

Replacement of lead-loaded glovebox glove with attenuation medium that are not RCRA-hazardous metals

Programmatic operations at the Los Alamos National Laboratory Plutonium Facility (TA-55) involve working with various amounts of plutonium and other highly toxic, alpha-emitting materials. The spread of radiological contamination on surfaces, airborne contamination, and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes (the glovebox, coupled with an adequate negative pressure gradient, provides primary confinement). Radiation shielding is commonly used to protect the glovebox worker from unintentional direct and secondary radiation exposure, while working with plutonium-238 and plutonium-239. In these environments, low-energy photons, i.e., those less than 250 keY, are encountered. Shielding glove box gloves are traditionally composed of lead-based materials, but these are now considered hazardous waste. This has prompted the development of new, nonhazardous- shielding gJovebox gloves. No studies, however, have investigated the effectiveness of these new glovebox gloves. We examined both leaded and nonhazardous- shielding glovebox gloves and compared their attenuation effectiveness over the energy range of interest at TA-55. All measurements are referenced to lead sheets, allowing direct comparisons to the common industry standard of 0.1 mm lead equivalent material. The attenuation properties of both types of glovebox gloves vary with energy, making it difficult for manufacturers to claim lead equivalency across the entire energy range used at TA-55. The positions of materials' photon energy absorption edges, which are particularly important to improved attenuation performance, depending upon the choice of radiation energy range, are discussed. This effort contributes to the Los Alamos National Laboratory Continuous Improvement Program by improving the efficiency, cost effectiveness, and formality of glovebox operations.

57↗

Measurement of the plutonium hold-up in glove box before dismantling - 15111

The French Bruyeres-Le-Chatel CEA (Commissariat a l'Energie Atomique et aux Energies Alternatives - French Alternatives Energies and Atomic Energy Commission) research center is going through a period of cleaning and dismantling of theses old treatment facilities on fissile materials and others associated nuclides. Some very large glove boxes contained some machines like melting furnace which can't be moved and are dismantled in situ. We need to evaluate the quantity of fissile materials to prevent criticality risk, to bring the evidence to the safety authority, to manage for the best the radioprotection of the workers and to manage waste production. A melting furnace in a glove box was dismantled. Measurements by gamma spectrometry with an HPGe detector (High Purity Germanium) and passive neutron counting (coincidence counting with shift register) are done in situ (furnace in the glove box). In order to refine the measurements, some data acquisitions by sector of glove box were carried out. In view of the geometries to characterize, some modelings have been created, in order to correct the different attenuations and to determine the plutonium masses content in the glove box, including the use of infinite energy technique. For the measurement by passive neutron counting (coincidence counting with shift register), we have used two slabs in high density polythene including nine He3 counters in each slab. This measurement technique is complementary to gamma spectrometry, and allows quantizing the fissile material which would be included in interstice of high Z material. The 100-L and 200-L drums produced during the dismantling were also measured. Based on simplified assumptions to analyze in situ measurements, plutonium weight could be evaluated. This approach of measurement in amount, during and after dismantling, has allowed to quantize the fissile material mass present in the glove box and didn't produce waste package which wouldn't respected the technical specifications of storage outlets. The results show good agreement between in situ and waste measurements. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Design innovation for the management of alpha contaminated unserviceable glove boxes

With the maturing of nuclear industry, there is an added burden on the Back End of fuel cycle. Radioactive facilities are in the need for refurbishment. This paper describes the steps adopted for managing such alpha contaminated unserviceable Glove Boxes. The first step consisted of in-situ encasement of individual Glove Boxes, encountering the challenges of low head room and space congestion in these laboratories with cognizance to regulatory requirement related to radiation safety. The second step was removal, transfer and placement of encased Glove Boxes in a dedicated facility under continuous surveillance. The glove boxes will remain stored in this facility until arrangements are completed for dismantling and volume reduction in another facility dedicated for this purpose. The final step is the development of an appropriate technique for dismantling/cutting of Glove Boxes in an alpha-tight facility constructed to prevent spread of airborne activity, collection of cut pieces, subsequent decontamination of these metallic wastes and disposal. The paper describes the design scheme for dismantling of the glove box. The description also includes hands on evaluation of tools and gadgets in pilot set-up with a view to incorporating the most credible choice in an upcoming active facility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗