Search NASA⌕ Search

SEARCH · Search NASA

Results for “GRIP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

GRiP - A flexible approach for calculating risk as a function of consequence, vulnerability, and threat.

Get a GRiP (Gravitational Risk Procedure) on risk by using an approach inspired by the physics of gravitational forces between body masses! In April 2010, U.S. Department of Homeland Security Special Events staff (Protective Security Advisors [PSAs]) expressed concern about how to calculate risk given measures of consequence, vulnerability, and threat. The PSAs believed that it is not 'right' to assign zero risk, as a multiplicative formula would imply, to cases in which the threat is reported to be extremely small, and perhaps could even be assigned a value of zero, but for which consequences and vulnerability are potentially high. They needed a different way to aggregate the components into an overall measure of risk. To address these concerns, GRiP was proposed and developed. The inspiration for GRiP is Sir Isaac Newton's Universal Law of Gravitation: the attractive force between two bodies is directly proportional to the product of their masses and inversely proportional to the squares of the distance between them. The total force on one body is the sum of the forces from 'other bodies' that influence that body. In the case of risk, the 'other bodies' are the components of risk (R): consequence, vulnerability, and threat (which we denote as C, V, and T, respectively). GRiP treats risk as if it were a body within a cube. Each vertex (corner) of the cube represents one of the eight combinations of minimum and maximum 'values' for consequence, vulnerability, and threat. The risk at each of the vertices is a variable that can be set. Naturally, maximum risk occurs when consequence, vulnerability, and threat are at their maximum values; minimum risk occurs when they are at their minimum values. Analogous to gravitational forces among body masses, the GRiP formula for risk states that the risk at any interior point of the box depends on the squares of the distances from that point to each of the eight vertices. The risk value at an interior (movable) point will be dominated by the value of one vertex as that point moves closer and closer to that one vertex. GRiP is a visualization tool that helps analysts better understand risk and its relationship to consequence, vulnerability, and threat. Estimates of consequence, vulnerability, and threat are external to GRiP; however, the GRiP approach can be linked to models or data that provide estimates of consequence, vulnerability, and threat. For example, the Enhanced Critical Infrastructure Program/Infrastructure Survey Tool produces a vulnerability index (scaled from 0 to 100) that can be used for the vulnerability component of GRiP. We recognize that the values used for risk components can be point estimates and that, in fact, there is uncertainty regarding the exact values of C, V, and T. When we use T = t{sub o} (where t{sub o} is a value of threat in its range), we mean that threat is believed to be in an interval around t{sub o}. Hence, a value of t{sub o} = 0 indicates a 'best estimate' that the threat level is equal to zero, but still allows that it is not impossible for the threat to occur. When t{sub o} = 0 but is potentially small and not exactly zero, there will be little impact on the overall risk value as long as the C and V components are not large. However, when C and/or V have large values, there can be large differences in risk given t{sub o} = 0, and t{sub o} = epsilon (where epsilon is small but greater than a value of zero). We believe this scenario explains the PSA's intuition that risk is not equal to zero when t{sub o} = 0 and C and/or V have large values. (They may also be thinking that if C has an extremely large value, it is unlikely that T is equal to 0; in the terrorist context, T would likely be dependent on C when C is extremely large.) The PSAs are implicitly recognizing the potential that t{sub o} = epsilon. One way to take this possible scenario into account is to replace point estimates for risk with interval values that reflect the uncertainty in the risk components. In fact, one could argue that T never equals zero for a man-made hazard. This paper describes the thought process that led to the GRiP approach and the mathematical formula for GRiP and presents a few examples that will provide insights about how to use GRiP and interpret its results.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Design and Evaluation of a Ring Tension Test Grip for Remote Mechanical Testing of Irradiated Tubular Specimens

Here, the ring tension test (RTT) is a mechanical testing method for determining bulk mechanical behavior in the circumferential or hoop direction for tubular materials. The test is especially useful for testing materials with anisotropic mechanical properties, such as zirconium alloys, which are commonly used as nuclear fuel cladding. Anisotropy requires direction-specific testing to determine the hoop strength. Historically, several RTT methods and grips have been used, each method has its strengths and weaknesses, and, in all cases, the measured strength is subject to uncertainty due to variations of the testing geometry and experimental tolerances. Recent analysis has shown that grips with a hemicylindrical mandrel configuration are recommended as the most robust configuration. The two strictest aspects to be controlled are the ability to determine gage region orientation and closely matching the size of the mandrels to the test specimen. This last requirement is particularly challenging when the dimensions of the specimen vary because of environmental effects such as dimensional changes due to irradiation. This paper presents a new RTT grip designed to incorporate this mandrel shape, hold the gage at the desired orientation, be suitable for remote operation in a hot-cell environment, and be adaptable for different sizes or variations in the specimen size. The general description and the unique design features of the test specimen and grips are given in detail. The performance of the grips in mechanical testing, including in a remote hot-cell environment, is also provided.

42 ENGINEERING↗

GRIP: Constraint-based Explanation of Missing Answers for Graph Queries

Abstract: A useful feature in graph query engines is to clarify “Why certain entities (nodes, attribute values or edges) are missing” in query answers. This task is even more challenging when the relevant data is already missing in the underlying data source. Missing data, on the other hand, can be inferred by enforcing data constraints for graphs. We demonstrate GRIP, a system that exploits data constraints to clarify missing answers for graph queries. (1) Constraint-based ex- planation. Given a desired yet missing entity in the query answer, GRIP ensures to generate finite and minimal sequences of data con- strains (an “explanation”) that should be consecutively enforced to ?? to ensure its occurrence for the same query. (2) Answering “why” and“how” questions. Users can query GRIP with both“Why”(“Why” the element is missing) and “How” questions (“How” to refine the graph to include the missing answer). GRIP engine supports run- time generation of explanations by incrementally maintaining a set of bi-directional search trees. (3) Interactive exploration. GRIP provides a user-friendly GUI to support interactive ad visual exploration of explanations, including both automated generation and step-by-step inspection of graph manipulations.

graphs↗

Graph Identification of Proteins in Tomograms (GRIP-Tomo) 2.0: Topologically aware classification for proteins

Cryo-electron tomography (cryo-ET) enables structural characterization of biomolecules under near-native conditions. Existing approaches for interpreting the resulting three-dimensional volumes are computationally expensive and have difficulty interpreting density associated with small proteins/complexes. To explore alternate approaches for identifying proteins in cryo-ET data we pursued a Graph Network and topologically invariant approach. Here, we report on a fast algorithm that classifies particles by searching for nuances of evolutionarily conversed motifs and the geometrical characteristics of protein structure. GRIP-Tomo 2.0 is a machine-learning pipeline that extracts interpretable topological features of protein structures within noisy experimental backgrounds. Compared to version 1.0, the new pipeline includes three upgrades that significantly improve performance including synthetic tomogram generation simulating realistic noise, graph-based persistent feature extraction as protein fingerprints, and high-performance computing acceleration. GRIP-Tomo 2.0 achieves over 90% accuracy in classifying between proteins and noise using both real and synthetic datasets which represents a foundational step toward advancing cryo-ET workflows and empowering automated visual proteomics.

Li, Chengxuan↗

Choice reaction time and grip strength as predictors of cardiovascular mortality in middle‐aged and elderly Japanese: from the Radiation Effects Research Foundation Adult Health study

Abstract Background Cognitive function and physical function are important predictors of mortality. Aim To investigate whether or not reaction time (RT) as a cognitive function and grip strength (GS) as a physical function were associated, alone or in combination, with mortality from heart disease or stroke. Methods The subjects included 4901 Adult Health Study participants in Hiroshima who had undergone RT and GS measurements, were 35–74 years old at baseline (1970–1972) and were followed until the end of 2007. Results After adjustment for other potential risk factors, RT was positively and GS was negatively associated with mortality from both heart disease and stroke. These associations were persistent in the model when adjusting simultaneously for RT, GS and other factors, but hazard ratios were attenuated. When we evaluated the associations by baseline age and gender, we found the greater hazard ratios for RT in the younger cohort, but no clear modification by age for GS. The interaction between RT and GS was statistically significant ( P = 0.012) for stroke mortality. In the stratified analyses divided using the age‐specific median value of RT or GS, the estimated hazard ratio of stroke mortality for RT was significant in participants with weak or strong GS but greater in the former, and for GS, it was only significant in participants with slow RT. Conclusion RT and GS, alone and in combination, predicted heart disease and stroke mortalities. Interventions for both cognitive function and physical function may be beneficial for the prevention of cardiovascular disease mortality.

Shimizu, Masaki↗

Grips for testing of electrical characteristics of a specimen under a mechanical load

Various technologies to facilitate coupled electrical and mechanical measurement of conductive materials are disclosed herein. A gripping device simultaneously holds a specimen in place and causes contact to be made between the specimen and a plurality of electrodes connected to an electrical measuring device. An electrical characteristic of the specimen is then measured while a mechanical load is applied to the specimen, and a relationship between the mechanical load and changes in the electrical characteristic can be identified.

47 OTHER INSTRUMENTATION↗

Graph identification of proteins in tomograms ( GRIP‐Tomo )

Abstract In this study, we present a method of pattern mining based on network theory that enables the identification of protein structures or complexes from synthetic volume densities, without the knowledge of predefined templates or human biases for refinement. We hypothesized that the topological connectivity of protein structures is invariant, and they are distinctive for the purpose of protein identification from distorted data presented in volume densities. Three‐dimensional densities of a protein or a complex from simulated tomographic volumes were transformed into mathematical graphs as observables. We systematically introduced data distortion or defects such as missing fullness of data, the tumbling effect, and the missing wedge effect into the simulated volumes, and varied the distance cutoffs in pixels to capture the varying connectivity between the density cluster centroids in the presence of defects. A similarity score between the graphs from the simulated volumes and the graphs transformed from the physical protein structures in point data was calculated by comparing their network theory order parameters including node degrees, betweenness centrality, and graph densities. By capturing the essential topological features defining the heterogeneous morphologies of a network, we were able to accurately identify proteins and homo‐multimeric complexes from 10 topologically distinctive samples without realistic noise added. Our approach empowers future developments of tomogram processing by providing pattern mining with interpretability, to enable the classification of single‐domain protein native topologies as well as distinct single‐domain proteins from multimeric complexes within noisy volumes.

59 BASIC BIOLOGICAL SCIENCES↗

Structures of two Arabidopsis thaliana major latex proteins represent novel helix-grip folds

Here we report the first structures of two major latex proteins (MLPs) which display unique structural differences from the canonical Bet v 1 fold described earlier. MLP28 (SwissProt/TrEMBL ID Q9SSK9), the product of gene At1g70830.1, and the At1g24000.1 gene product (Swiss- Prot/TrEMBL ID P0C0B0), proteins which share 32% sequence identity, were independently selected as foldspace targets by the Center for Eukaryotic Structural Genomics. The structure of a single domain (residues 17-173) of MLP28 was solved by NMR spectroscopy, while the full-length At1g24000.1 structure was determined by X-ray crystallography. MLP28 displays greater than 30% sequence identity to at least eight MLPs from other species. For example, the MLP28 sequence shares 64% identity to peach Pp-MLP119 and 55% identity to cucumber Csf2.20 In contrast, the At1g24000.1 sequence is highly divergent (see Fig. 1), containing a gap of 33 amino acids when compared with all other known MLPs. Even when the gap is excluded, the sequence identity with MLPs from other species is less than 30%. Unlike some of the MLPs from other species, none of the A. thaliana MLPs have been characterized biochemically. We show by NMR chemical shift mapping that At1g24000.1 binds progesterone, demonstrating that despite its sequence dissimilarity, the hydrophobic binding pocket is conserved and, therefore, may play a role in its biological function and that of the MLP family in general.

59 BASIC BIOLOGICAL SCIENCES↗

Repositioning of Covered Stents: The Grip Technique

Introduction: Retrieval and repositioning of a stent deployed beyond its intended target region may be a difficult technical challenge. Materials and Methods: A balloon-mounted snare technique, a variant of the coaxial loop snare technique, is described. Results: The technique is described for the repositioning of a covered transjugular intrahepatic portosystemic shunt stent and a covered biliary stent. Conclusion: The balloon-mounted snare technique is a useful technique for retrieval of migrated stents.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coming to Grips with Ambiguity: Ion Mobility-Mass Spectrometry for Protein Quaternary Structure Assignment

Multiprotein complexes are central to our understanding of cellular biology, as they play critical roles in nearly every biological process. Despite many impressive advances associated with structural characterization techniques, large and highly-dynamic protein complexes are too often refractory to analysis by conventional, high-resolution approaches. To fill this gap, ion mobility-mass spectrometry (IM-MS) methods have emerged as a promising approach for characterizing the structures of challenging assemblies due in large part to the ability of these methods to characterize the composition, connectivity, and topology of large, labile complexes. In this Critical Insight, we present a series of bioinformatics studies aimed at assessing the information content of IM-MS datasets for building models of multiprotein structure. Our computational data highlights the limits of current coarse-graining approaches, and compelled us to develop an improved workflow for multiprotein topology modeling, which we benchmark against a subset of the multiprotein complexes within the PDB. This improved workflow has allowed us to ascertain both the minimal experimental restraint sets required for generation of high-confidence multiprotein topologies, and quantify the ambiguity in models where insufficient IM-MS information is available. We conclude by projecting the future of IM-MS in the context of protein quaternary structure assignment, where we predict that a more complete knowledge of the ultimate information content and ambiguity within such models will undoubtedly lead to applications for a broader array of challenging biomolecular assemblies. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Getting a grip on the transverse motion in a Zeeman decelerator

Zeeman deceleration is an experimental technique in which inhomogeneous, time-dependent magnetic fields generated inside an array of solenoid coils are used to manipulate the velocity of a supersonic beam. A 12-stage Zeeman decelerator has been built and characterized using hydrogen atoms as a test system. The instrument has several original features including the possibility to replace each deceleration coil individually. In this article, we give a detailed description of the experimental setup, and illustrate its performance. We demonstrate that the overall acceptance in a Zeeman decelerator can be significantly increased with only minor changes to the setup itself. This is achieved by applying a rather low, anti-parallel magnetic field in one of the solenoid coils that forms a temporally varying quadrupole field, and improves particle confinement in the transverse direction. The results are reproduced by three-dimensional numerical particle trajectory simulations thus allowing for a rigorous analysis of the experimental data. The findings suggest the use of a modified coil configuration to improve transverse focusing during the deceleration process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗