Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma discrimination”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Crystal growth, scintillation properties & fast neutron-gamma discrimination of cubic halide perovskite CsCaCl 3 :(Eu 2+ , Tl + )

The vast variety of nuclear security applications require radiation detection materials tailored to their operational needs. A scintillator’s properties are strongly influenced by the choice of luminescent dopant, which facilitates customization to different applications. In this work, transparent Ø12 mm single crystals of undoped CsCaCl 3 , CsCaCl 3 :1% Eu, CsCaCl 3 :1% Tl, and CsCaCl 3 :1% Eu, 1% Tl were grown via the Vertical Bridgman method. Their scintillation properties and fast neutron-gamma discrimination capabilities were investigated. Undoped CsCaCl 3 had a light yield of 2,500 ph/MeV, which is the highest reported to date for this CVL material. The incorporation of Eu 2+ or Tl + into CsCaCl 3 as luminescence centers resulted in significantly higher light yields of ∼16,000 ph/MeV and energy resolutions of ∼8% at 662 keV. Compared to the single dopant counterparts, CsCaCl 3 :Eu, Tl had significantly suppressed afterglow; however, this came at the cost of reduced light yield. Among the materials tested, only CsCaCl 3 :Tl showed effective fast neutron and gamma discrimination capabilities, achieving a Figure of Merit of 3.2 between gamma-rays and fast neutron captures that produce protons and 1.6 between gamma-rays and fast neutron captures that produce alpha particles.

crystal growth↗

Optimizing the spatial resolution and gamma discrimination of SiPM-based Anger cameras

SiPM Anger cameras have been designed for use as 2-dimensional thermal neutron detectors for scientific applications such as at single crystal diffraction instruments. These cameras utilize a neutron sensitive scintillator and an array of SiPM photosensors, separated by a light spreading glass. While this optics package is very effective at detecting and positioning neutrons, it is also sensitive to gamma rays, which are a source of unwanted noise. In this work, we underwent a search of scintillator and spreader glass thicknesses to determine the optimal combination for maximizing spatial resolution. Both experimental results and GEANT4 simulations are presented. Further, to address the issue of gamma ray detection, we have also designed and presented a multi-layer scintillator that reduces the amount of scintillation light produced via gamma-ray energy deposition, allowing for easier pulse-height discrimination. A sample of this geometry has been produced that results in a factor of 2 improvement over an equivalent thickness monolithic scintillator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Boron-10 Doped Polysiloxanes as Matrix Materials for Application in the Simultaneous Detection and Discrimination of Gamma Rays and Fast and Thermal Neutrons

Three boron-10 enriched aromatic molecules have been synthesized and incorporated into two different commercial polysiloxane resins, Shin Etsu KER-6000 and Wacker SilRes H62-C. Scintillating fluorophores, 9,9-dimethyl-2-phenylfluorene (PhF) and 2,5-diphenyloxazole (PPO), were tested in combination with each resin and boron-10 molecule for the simultaneous detection of gamma rays, fast neutrons, and thermal neutrons. Here, the H62-C resin was able to solubilize a large amount of PhF, in excess of 20 wt%. Cure kinetics were controlled through the addition of divinylbenzene and phenyl tris(dimethylsiloxy)silane cross-linker solution to the H62-C resin, with rheology experiments demonstrating a large reduction in time to gelation when 20 wt% cross-linker solution was added, from more than 4 hours to less than 1 hour. These polysiloxane resins can be cured in 3 hours under air, while common poly(vinyltoluene) scintillators require at least 4 days of heating and oxygen-free conditions. PhF-doped KER-6000 with tolyl boronate pinacol ester exhibited the best overall performance with a light yield of 62% relative to EJ-200 and thermal neutron capture at energies up to 103 keVee (84 keVee for EJ254B-5). Additionally, four samples exhibited light yields surpassing an industry-standard boron-doped plastic scintillator, Eljen’s EJ254B-5. Over the course of ten months, the KER-6000 samples showed precipitation of dopant molecules, which reduced their light yield by 15% on average, while H62-C proved to be more stable with only a 6% reduction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called γ-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps towards such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C 6 D 6 detectors, and one LaCl 3 (Ce) detector. The performance of these detection systems is compared using 93 Nb(n, γ) data. We also developed a detailed G EANT small4 Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a γ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigated experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electromagnetic energy calibration of the SoLid detector with horizontal muons

SoLid is a neutrino experiment at very-short baselinesearching for active-to-sterile oscillations of reactorantineutrinos. The detection principle is based on the pairing oftwo types of solid scintillators: polyvinyl toluene and $^{6}$Li:ZnS(Ag), which is a new technology used in this field ofPhysics. In addition to good neutron-gamma discrimination, thissetup allows the detector to be highly segmented; the basicdetection unit is a 5 cm cube. High segmentation provides numerousadvantages including precise localisation of the Inverse Beta Decay(IBD) products, the derivation of an antineutrino energy estimatorbased on the isolated positron energy, and a powerful backgroundreduction tool that relies on the topological signature of thesignal. Finally, the system is read out by a network ofwavelength-shifting fibres coupled to photosensors. A relativeelectromagnetic calibration is performed with horizontal cosmicmuons. This source poses the simplest calibration problem in which asingle detection unit is involved. In addition, large muon energydeposits allow us to perform a calibration at the most detailedlevel (i.e. per fibre) and to accurately define the fraction ofenergy escaping to neighbouring detection cells. A statisticalprecision at the sub-percent level is reached. The paper alsodiscusses two methods to calibrate the absolute energy scale andpresents their implementation and results. The first method relieson horizontal muons, though the precision is limited to around 10%because of the uncertainty in the energy distribution of suchmuons. A novel, alternative method based on the radioactiveamericium-beryllium source is proposed. It takes advantage of theelectron-positron pair-production process and provides a calibrationpoint at 3.4 MeV (i.e. in the core of the IBD positronspectrum). The paper is concluded with various cross-check includinga determination of the energy spectrum of the standard cosmogenicbackground candle: $^{12}$B.

Abreu, Y. [Antwerp U.]↗

Performance stability of plastics for neutron-gamma pulse shape discrimination

The introduction of the first commercially available plastic scintillators with pulse shape discrimination (PSD) offered by Eljen Technology marked progress towards potentially replacing liquid scintillators in neutron detection. However, use of these plastics over several recent years has revealed an important flaw in these materials: the eventual degradation of scintillation light output and PSD performance. Here, studies described in this paper considered possible reasons for this degradation. Experiments conducted with numerous lab-prepared and commercial EJ-276 samples showed that the main factor affecting the instability is oxidation that involves highly reactive radicals generated during the polymerization process or from the further breakdown of polymer chains under oxygen/air exposure. Based on the obtained results, the stability of scintillation performance for PPO (2,5-Diphenyloxazole)-based PSD plastics has been improved through modifications of the composition via the utilization of scintillation dyes and compounds with antioxidant properties that diminish the effects of oxidation. Elements of these studies were used in the commercial production of the most recent EJ-276D PSD plastic version for fast neutron detection and 6Li-loaded plastics for thermal neutron and antineutrino detection applications. Performance projections of the new PSD plastics indicate a likely degradation of less than 10 % over 5–10 years in comparison to previous EJ-276 that might lose up to 30–40 % of the scintillation light during 1–2 years of storage or deployment under ambient conditions.

36 MATERIALS SCIENCE↗

HIGHER EFFICIENCY FISSION COUNTER FOR NEUTRON DETECTION

Fission chambers containing 235U have been used for detection of neutrons for many decades. In these chambers 235U is electroplated on a metal which is one plate of an ionization chamber. Since the range of fission products from induced fission in the chamber is extremely short, these deposits from electroplating are so thin that the amount of 235U results in low neutron detection efficiency and the chamber needs high internal 235U surface area to increase efficiency. A typical ~8 in. long, ~2 in. diameter fission counter only contains < 2 g of 235U total, resulting in very low detection efficiency per incident neutron impinging on the outer surface of the detector. However, because of their large electronic pulses from fission products compared to gamma rays it is very easy to discriminate against gamma rays impinging on the detector. These types of chambers are produced commercially and are used worldwide in nuclear research and nuclear power reactors. ORNL has made a higher efficiency fission ionization chamber by using many thin concentric annuli to increase the area. A higher efficiency fission counter would be useful and can be made by incorporating 235U into a glass or ceramic scintillator. For nearly 100 years the green color in antique glass was produced by incorporation of depleted uranium (up to 20 wt. %) into a glass. The concept for this scintillation-optical-based fission detector is to dope a scintillator (either ceramic or glass) with 235U. Glass scintillators are commercially available doped with as much as 8 wt. % 6Li for neutron detection. In the 235U doped scintillator the fission product pulses would be double the size of those in an ion chamber since all fission products produce light in the scintillator whereas in the ionization chamber half do not go into the ionizing gas volume. These higher efficiency fission chambers would be very useful for a wide variety of research, nuclear research, and nuclear power reactor applications. Because of their smaller size and weight, they should be useful for space application such as monitoring of space nuclear power reactors. This report reviews existing fission chamber technology and suggests the development of these small high-efficiency fission chambers. Other fission isotopes could be used for other research applications.

Mihalczo, John [ORNL] (ORCID:0000000254292681)↗

Pixelated plastic scintillator array manufacturing using fast-, photo-curable resin

Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This article presents a fabrication method based on additive manufacturing for two-dimensional plastic organic scintillator arrays using a custom-built automated assembly machine and a custom photocurable resin that has significant non-aromatic acrylate oligomer content. The process involves two main stages: fully autonomous production of one-dimensional layered arrays, followed by semi-autonomous cutting and stacking to form two-dimensional pixel arrays. One-dimensional arrays were manufactured at a rate of around 4 layers per hour with minimal defects and tight dimensional tolerances, while two-dimensional arrays up to 7 x 7 pixels and 70 mm in length were completed in approximately 3.5 hours. Final arrays exhibited dimensional deviations of less than 0.5 mm. Two-dimensional arrays read out by a multi-anode photomultiplier tube demonstrated per-pixel position resolution and pulse-shape discrimination, enabling gamma–neutron interaction separation in mixed radiation environments.

36 MATERIALS SCIENCE↗

Novel imaging technique for thermal neutrons using a fast optical camera

A novel imaging technique for thermal neutrons using a fast optical camera is presented. Thermal neutrons are reacted with 6 Lithium to produce a pair of 2.73 MeV tritium and 2.05 MeV alpha particles, which in turn interact in a thin layer of LYSO crystal scintillator to produce a localized flash of light. These photons are directed by a pair of lenses to a micro-channel plate intensifier, and its output is connected to the optical camera, TPX3CAM. The results from the camera are reconstructed through a custom algorithm. Various cutting parameters were found through data analysis to eliminate the background, and they were shown effective in matching the simulated rate of the neutron source. The system is fast with 40 ns decay time and allows free-space light collection, both vastly enhances flexibility of neutron detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sub-millimeter resolution SiPM-based neutron anger camera

Thermal and cold neutron beamlines require detector systems that have a high neutron efficiency, large active area, and good spatial resolution. One type of detector that has been implemented at beamlines at the Spallation Neutron Source (SNS) is a scintillator-based Anger camera that utilizes photomultiplier tubes (PMTs) as photodetectors. In this work, we present a new Anger camera design that replaces PMTs with silicon photomultipliers (SiPMs). This new design offers better resolution, less distortion, and more compactness than the previous cameras. A camera with active area of ~100 cm 2 was shown to have a spatial resolution better than 0.5 mm. Additionally, the use of SiPMs allows for use in strong magnetic fields, opening the possibility of additional experimental capabilities. In conclusion, prototype has been built that demonstrates vacuum-compatibility, as required for a proposed beamline for the Second Target Station at SNS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced Neutron and γ-Ray Detection via 6 Li Substitution in Undoped and Tl-Doped Zero-Dimensional Perovskite Cs 3 Cu 2 I 5 Scintillators

Radiation detectors are crucial in a wide variety of research and commercial applications, such as oil and gas exploration, medical imaging, nuclear nonproliferation, and homeland security. Neutron and gamma-ray detectors are fundamental components in portal monitors at ports and border crossings, bolstering national security against radiological threats. This study presents a dual-mode scintillator, undoped and Tl-doped 6 Li-Cs 3 Cu 2 I 5 , and demonstrates its potential as a promising material for simultaneous thermal neutron and gamma-ray detection. We explore the Bridgman growth of both undoped and thallium doped Li → Cu and Li → Cs substitutional systems with various Li doping levels and assess their impact on scintillation properties. Under 662 keV gamma-ray excitation, the undoped crystals had light yields up to 35,900 ph/MeV, with energy resolutions down to 4.5%. The Tl-doped crystals performed better than the undoped crystals with light yields peaking at 65,900 ph/MeV and energy resolutions as low as 3.5%. When exposed to a moderated 252 Cf excitation source, our crystals had light yields between 102,900 and 167,200 photons per thermal neutron capture, with a full energy thermal neutron peak reaching 3 MeV in gamma equivalent energy. Pulse shape discrimination studies reveal well-separated gamma and neutron events, resulting in Figure-Of-Merit (FOM) as high as 3.7. Furthermore, these findings highlight the potential of Li-doped Cs 3 Cu 2 I 5 as a viable candidate for next-generation dual-mode scintillators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration of a compact ASIC-based data acquisition system for neutron/$γ$ discrimination and spectroscopy with organic scintillators

Segmented neutron detectors that use silicon photomultipliers (SiPMs) are receiving significant attention in nuclear security applications. Some of these detectors employ hundreds of channels and would therefore benefit from the use of high-channel-density and low-cost-per-channel data acquisition (DAQ) systems. Candidate DAQ systems that meet these requirements exist, but few perform full waveform digitization, which permits neutron and gamma-ray interaction discrimination via pulse shape. In this work, we study the performance of the TOFPET2 (PETsys Electronics), an ASIC-based DAQ designed for positron emission tomography, which has been adapted to provide sensitivity to pulse shape by the use of variable-period charge integration. We use a light-emitting diode to calibrate a combination of an ON Semiconductor (SensL) 60035-64P J-Series SiPM and TOPFET2 DAQ and evaluate the linearity of their response and dynamic range. Here, the calibration curve was obtained by comparing the DAQ response to that measured with a photodiode interfaced with a traditional waveform digitizer. This calibration process was used for rudimentary spectroscopy of various neutron and sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gamma-ray imaging of Np-237 metal using an organic glass imager

Neutron and gamma-ray imaging systems are deployed within the field of nuclear safeguards for the detection and localization of special nuclear materials and other materials of interest. 237 Np is one of these materials of interest due its presence in spent nuclear fuel and potential for use in nuclear weapons when purified. Here, for the first time, a 6 kg neptunium sphere (98.8 wt% 237 Np) was measured using a dual-particle imager, from the University of Michigan, consisting of organic glass and inorganic scintillators. The novel composition of organic glass scintillator was recently developed at Sandia National Labs and has been used in particle imaging systems due to its time resolution and particle discrimination capabilities. Gamma-ray energy spectra from single and coincident events were extracted and the sequencing of Compton scatter and photoelectric absorption gamma-ray events was used to generate images using simple backprojection. The emissions of interest in this work are the 312 keV and 416 keV gamma rays from 233 Pa, a daughter isotope from the neptunium decay series. The results of this work show that there is close agreement between the true source location in angular space and the converged location from the gamma ray images created using the system. The gamma spectroscopy from single and coincident events also identified the characteristic emission from the daughter isotope and could be used to assist with the identification of 237 Np. Furthermore, successful localization of the source with 5 s of data demonstrates the practical application of the imaging system for imaging and detection of material in weapons-useable quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gallium oxide (Ga2O3) as a radiation detector distinguishing neutrons and gammas

Gallium oxide (Ga2O3) is a promising ultrawide bandgap semiconductor for radiation detection with the potential of integrating electronic and scintillation functions within a single crystal device. This study establishes the scintillation response of β-Ga2O3 gamma irradiation from yttrium-88 (88Y). Then, californium-252 (252Cf) is used as a spontaneous fission source of mixed neutron and gamma radiation field to measure scintillation signals. Pulse shape discrimination and constant fraction discrimination techniques were used to separate neutron and gamma interaction events. Further investigation indicates that the prompt temporal responses of β-Ga2O3 for gammas and neutrons may enable discrimination of the two by prompt pulse fitting methods, focused around the initial peak. For gamma irradiation, we observed a rise time (τr) of 2.1 ns, decay time (τd) of 9.5 ns, and a full width at half maximum (FWHM) of 6.2 ns. For neutrons, it showed a τr of 2.3 ns, a τd of 12.1 ns, 9.4 ns FWHM, and reduced peak intensity. A diamond detector exhibited a more symmetrical τr and τd for both gamma and neutron signals and therefore is less effective at discriminating between the two by this method. This draws attention to β-Ga2O3’s ability to distinguish neutron and gamma particles. These findings showcase Ga2O3’s potential as a next-generation semiconductor for applications in nuclear safety and medical imaging, where precise discrimination between neutron and gamma interactions is essential.

Valdes, D. J. (ORCID:0000000304373720)↗

Response of a high-pressure 4 He scintillation detector to nuclear recoils up to 9 MeV

Helium-4-based scintillation detector technology is emerging as a strong alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, particularly in extreme gamma-ray environments. The 4 He detector is intrinsically insensitive to gamma radiation, as it has a relatively low cross-section for gamma-ray interactions, and the stopping power of electrons in the 4 He medium is low compared to that of 4 He recoil nuclei. Consequently, gamma rays can be discriminated by simple energy deposition thresholding instead of the more complex pulse shape analysis. The energy resolution of 4 He scintillation detectors has not yet been well-characterized over a broad range of energy depositions, which limits the ability to deconvolve the source spectra. In this work, an experiment was performed to characterize the response of an Arktis S670 4 He detector to nuclear recoils up to 9 MeV. The 4 He detector was positioned in the center of a semicircular array of organic scintillation detectors operated in coincidence. Deuterium–deuterium and deuterium–tritium neutron generators provided monoenergetic neutrons, yielding geometrically constrained nuclear recoils ranging from 0.0925 to 8.87 MeV. The detector response provides evidence for scintillation linearity beyond the previously reported energy range. Finally, the measured response was used to develop an energy resolution function applicable to this energy range for use in high-fidelity detector simulations needed by future applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution 3D-printed plastic scintillators with tertiary dye

Additive manufacturing offers efficient production of plastic scintillators with nontrivial geometries using vat polymerization, allowing fabrication of geometries which would be difficult or even impossible to produce using conventional subtractive manufacturing. This work presents a novel photocurable scintillator formula that includes coumarin 450 as a tertiary dye to enable high-resolution 3D printing via the manipulation of the 405 nm cure light. Bulk photocured and 3D printed (with and without tertiary dye) samples were compared through observational assessment and spectral response. All samples showed pulse shape discrimination between neutron and gamma events. Inclusion of the tertiary dye has minimal impact on emission spectrum and light output, but significant impact on print resolution as shown by comparison of printed high-complexity geometries and feature resolution test objects. With the use of a cure-limiting dye, unsupported features — such as freestanding pillars — were resolvable down to 0.7 mm. Even finer resolution at or below 0.1 mm was achieved in fully supported, integrated structures printed with off-the-shelf 405 nm desktop 3D printer. Scintillators demonstrated a light output up to 50% of EJ-200 with a PSD figure of merit up to 1.35 at 0.9–1.1 MeVee.

36 MATERIALS SCIENCE↗