Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Aging mechanisms of filled cross-linked polyethylene (XLPE) cable insulation material exposed to simultaneous thermal and gamma radiation

Thermal and simultaneous thermal and gamma radiation aging experiments were conducted on an industry grade cross-linked polyethylene (XLPE) cable insulation material, which is a composite material with XLPE as polymer matrix and various additives and fillers. Reverse engineering was conducted to identify and quantify the material composition given that this information was not revealed by the cable manufacture. Samples were then aged at temperatures of 60, 90, and 115 °C, exposed to gamma radiation for total doses of 0 to 324 kGy, and at dose rates of 0 to 540 Gy/h. Aging mechanisms were studied using various materials characterization techniques including pyrolysis gas chromatography mass spectrometry (Py-GCMS), differential scanning calorimetry (DSC), nuclear magnetic resonance spectroscopy (NMR), and gel-fraction tests. Results show that the flame-retardant components were decomposed into smaller molecules when the material was exposed to gamma radiation, while no changes were observed when the samples were aged thermally without gamma radiation. With exposure to gamma radiation, the crystalline phase of the XLPE were damaged by gamma radiation introducing defects in the crystals, resulting in smaller and less perfect crystals. The dominance of chain scission or chain reformation process largely depends on the chain mobility, which is decided by the aging temperature. Chain scission was seen to dominate when the material was exposed to gamma radiation at 60 °C. Chain cross-linking slightly dominated when the material was exposed to gamma radiation at 90 °C and became more dominant with exposure to gamma radiation at 115 °C. No significant change to the XLPE polymer matrix was observed when the samples were exposed to thermal aging without gamma radiation. Finally, antioxidant is more effective in protecting the XLPE polymer matrix under thermal aging, but less effective with sample exposure to gamma radiation.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Gamma Radiation Effects in Amorphous and Crystalline Polyaryletherketones

This work investigates the effect of gamma radiation on chain scission and crosslinking in polyaryletherketone (PAEK) thermoplastic filaments, namely, polyetheretherketone (PEEK) and polyetherketoneketone (PEKK) that is either semicrystalline (PEKK-c) or highly amorphous (PEKK-a). The PAEK thermoplastic filaments were exposed to total ionizing doses (TID) of gamma radiation from 1 to 8 MGy in the Gamma Irradiation Facility at Sandia National Laboratories. A combination of thermal and FT-IR spectral analysis of the irradiated specimens was used to study the chain scission and crosslinking behavior between PEEK, PEKK-c, and PEKK-a. Crystallinity decreased with increased TID and melt enthalpy decreased. Despite clear indications of changes to melt and crystallization behavior, any change to the glass-transition temperature was minor until a post-irradiation thermal annealing occurred, which caused an increase in crystallinity. Gamma radiation impacted PEKK-a more due to the lower degree of initial crystallinity, where a reduction in melt enthalpy, crystallinity, and crystallization kinetics was observed. Despite these effects, the ability to achieve a higher degree of crystallization (X c < 20%) by annealing was not affected. The results presented here provide important insight into the performance of a class of commercialized PEKK thermoplastics exposed to a harsh radiation environment.

Crystallinity↗

Gamma Radiation Monitoring Data

This dataset contains gamma-ray total counts in counts/minute (cpm), every 15-minutes, from the Gamma Radiation Monitoring campaign at the ENA site (Graciosa, Azores).

54 ENVIRONMENTAL SCIENCES↗

Materials for Gamma Radiation Sensors

Sensors used for spectroscopic measurements of gamma radiation are most often scintillator or semiconductor materials. An overview is provided in this chapter on the materials and development techniques used in producing spectroscopic gamma radiation sensors. Challenges that prevent a perfect sensor are discussed along with the reasons why some sensor materials are ubiquitous despite their performance limitations. The types of sensors commonly used as detectors are discussed along with their key physical properties and electronic characteristics. Materials commonly utilized in radiation detectors are then reviewed to highlight how sensor materials have advanced since the earliest gamma detectors were developed

Johns, Paul M.↗

Development of Hopfield Artificial Neural Network for Anomaly Detection in Environmental Gamma Radiation Background: Consortium on Nuclear Security Technologies (CONNECT) (Q2 Report)

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to explore supervised machine learning (ML) algorithms for development of a Hopfield Neural Network (HNN) in conjunction with an image processing algorithm for detection and identification of weak nuisances and anomalies events in the presence of a highly fluctuating background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic charge of the filter was correlated with a reduction in capturing particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test and reduction in aerosol filtering efficiency. Key Words: N95 respirators, respirators, airborne transmission, pandemic prevention, COVID-19, gamma sterilization

COVID-19↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic capability of the filter reduced the efficiency of challenging particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test.

61 RADIATION PROTECTION AND DOSIMETRY↗

Detection of Anomalies in Environmental Gamma Radiation Background with Hopfield Artificial Neural Network - Consortium on Nuclear Security Technologies (CONNECT) Q3 Report

Environmental screening of gamma radiation consists of detecting weak nuisance and anomaly signal in the presence of strong and highly varying background. In a typical scenario, a mobile detector-spectrometer continuously measures gamma radiation spectra in short, e.g., one-second, signal acquisition intervals. The measurement data is a 2D matrix, where one dimension is gamma ray energy, and the other dimension is the number of measurements or total time. In principle, gamma radiation sources can be detected and identified from the measured data by their unique spectral lines. Detecting sources from data measured in a search scenario is difficult due to the highly varying background because of naturally occurring radioactive material (NORM), and low signal-to-noise ratio (S/N) of spectral signal measured during one-second acquisition intervals. The objective of this work is to investigate performance of a Hopfield Neural Network (HNN) in in detection and identification of weak nuisances and anomalies events in the presence of a highly fluctuating background. Performance of HNN algorithm is benchmarked using search data from an environmental screening campaign. One data set contained a 137 Cs source, and another dataset contained a 131 I source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dose Rate Effects in the Aging of Nuclear Cable Insulation Subjected to Gamma Radiation

In nuclear power plants (NPPs), the aging of polymer-based electrical cable insulation must be effectively monitored to ensure the safe and reliable operation of NPPs. Gamma radiation is one of the main environmental stressors causing degradation of cable insulation. For a given total dose of absorbed gamma radiation, damage due to gamma irradiation may be dose rate dependent. The purpose of this work is to confirm whether a dose rate effect exists for the cable insulation made by crosslinked polyethylene (XLPE) and ethylene propylene rubber (EPR), quantify the relationship between degradation rate and dose rate, and explore the correlation of different measured properties. The dose rate effects at 1800 Gy/h, 200 Gy/h, and 100 Gy/h using 60Co gamma irradiation on cable aging was studied. Different types of cable insulation, including two XLPEs and one EPR, were irradiated at the different dose rates with a total dose around 300 kGy at 26 °C. The properties of unirradiated and irradiated samples were characterized by mass change, yellowness index, and other ongoing measurements. Dose rate effects were observed for mass change data of XLPE and EPR.

Li, Donghui↗

Sequential versus Simultaneous Aging of EPDM Nuclear Cable Insulation Subjected to Elevated Temperature and Gamma Radiation

Electrical cables are integral to power, control, and instrumentation systems within nuclear power plants (NPPs). Exposure of cable systems within nuclear containment to elevated temperatures and gamma radiation during decades-long operation of NPPs can lead to degradation of cable polymeric insulation. Prediction of nuclear cable insulation degradation is complicated as thermal and radiation stress are not additive. In this work, we explore the relative effects of simultaneous and sequential thermal and gamma irradiation on the aging of ethylene-propylene-diene (EPDM) elastomer insulation to better understand realistic scenarios of cable insulation degradation. Cable insulation samples of EPDM were subjected to up to 320 kGy of gamma radiation at a dose rate of 300 Gy/hr in two heating scenarios: (1) simultaneously aged samples were heated at 150°C during irradiation and (2) sequentially aged samples were heated at 150°C for designated durations followed by corresponding periods of irradiation at ambient temperature. The mass, tensile elongation at break, and carbonyl index were assessed to quantify aging of the polymers. The simultaneous aging scenario was found to the more severe of the two for EPDM insulation degradation.

ethylene-propylene-diene elastomer, EPDM, nuclear ↗

Gamma radiation sterilization of N95 respirators leads to decreased respirator performance

In response to personal protective equipment (PPE) shortages in the United States due to the Coronavirus Disease 2019, two models of N95 respirators were evaluated for reuse after gamma radiation sterilization. Gamma sterilization is attractive for PPE reuse because it can sterilize large quantities of material through hermetically sealed packaging, providing safety and logistic benefits. The Gamma Irradiation Facility at Sandia National Laboratories was used to irradiate N95 filtering facepiece respirators to a sterilization dose of 25 kGy(tissue). Aerosol particle filtration performance testing and electrostatic field measurements were used to determine the efficacy of the respirators after irradiation. Both respirator models exhibited statistically significant decreases in particle filtering efficiencies and electrostatic potential after irradiation. The largest decrease in capture efficiency was 40–50% and peaked near the 200 nm particle size. The key contribution of this effort is correlating the electrostatic potential change of individual filtration layer of the respirator with the decrease filtration efficiency after irradiation. This observation occurred in both variations of N95 respirator that we tested. Electrostatic potential measurement of the filtration layer is a key indicator for predicting filtration efficiency loss.

36 MATERIALS SCIENCE↗

Behavior of the Fused Quartz Suspended Core Acoustic Waveguide Sensor in Gamma Radiation

Previously, a fused-quartz acoustic waveguide named the suspended core waveguide with tight-field confinement in a small diameter was developed and its sensing potential in harsh environment was demonstrated with the fabricated periodic acoustic fiber Bragg grating. In this paper, the acoustic sensor was exposed to around 70 Gy/h gamma radiation at room temperature for 3550 h at Oak Ridge National Laboratory. For comparisons, a thermocouple and two optical fiber Bragg gratings were tested under the same conditions. The central frequency reading of the acoustic sensor was found to encounter a relatively fast decrease of 0.5 kHz in the first 800 hours. The reading then became stable, centering at 478.5 kHz with a fluctuation of ±0.2 kHz, and responded to small environmental temperature variations less than 1.2 °C. The major effect to the fluctuation was concluded to be radiation-induced material compaction and expansion. For optical fiber Bragg gratings, the same one-directional fast change of readings in the first 500 hours were observed as well. Although the optical gratings were able to track temperature changes, they also showed continuous drifts. The survivability and consistency of the acoustic sensor under long-term gamma radiation could lead to new sensing methods in nuclear applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Draft Specification for Representing Gamma Radiation Spectra in QR codes

This document defines a proposed specification for representing gamma radiation spectra, as commonly produced by handheld Radioisotope Identifiers, as a QR code, or as a Uniform Resource Identifier (URI). The intended primary application is transferring spectra between locations or devices using standard smart-phone capabilities when data transmission would otherwise be challenging or not possible. The proposed encoding also enables embedding of spectra within other documents as hyperlinks.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

PLA Renewable Bio Polymer Based Solid-State Gamma Radiation Detector-Dosimeter for Biomedical and Nuclear Industry Applications

Polylactic acid (PLA) as a “green,” renewable corn-soy based polymer resin was assessed as a novel solid-state detector for rapid-turnaround gamma radiation dosimetry in the 1–100 kGy range–of significant interest in biomedical and general nuclear industry applications. Co-60 was used as the source of gamma photons. It was found that PLA resin responds well in terms of rheology and porosity metrics with an absorbed gamma dose (Dg). In this work, rheological changes were ascertained via measuring the differential mass loss ratio (MLR) of irradiated PLA placed within PTFE-framed (40 mm × 20 mm × 0.77 mm) cavities bearing ~0.9 g of PLA resin and pressed for 12–16 min in a controlled force hot press under ~6.6 kN loading and platens heated to 227 °C for the low Dg range: 0–11 kGy; and to 193 °C for the extended Dg range: 11–120 kGy. MLR varied quadratically from 0.05 to ~0.2 (1σ ~ 0.007) in the 0–11 kGy experiments, and from 0.05 to ~0.5 (1σ ~0.01) in the 0–120 kGy experiments. Rheological changes from gamma irradiation were modeled and simultaneously correlated with void-pocket formations, which increase with Dg. A single PLA resin bead (~0.04 g) was compressed 5 min at 216 °C in 0–16 kGy experiments, and compressed 2 min at 232 °C in the 16–110 kGy experiments, to form sturdy ~100 µm thick wafers in the same press. Aggregate coupon porosity was then readily measurable with conventional optical microscope imaging and analyzed with standard image processing; this provided complementary data to MLR. Average porosity vs. dose varied quadratically from ~0 to ~15% in the 0–16 kGy range and from ~0 to ~18% over the 16–114 kGy range. These results provide evidence for utilizing “green”/renewable (under $0.01) PLA resin beads for rapid and accurate (+/-5–10%) gamma dosimetry over a wide 0–120 kGy range, using simple to deploy mass and void measuring techniques using common laboratory equipment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sequential versus Simultaneous Aging of XLPE Nuclear Cable Insulation Subjected to Elevated Temperature and Gamma Radiation

Electrical cables constitute a critical component of nuclear power generation. The aging behavior of electrical cable insulation under combined exposure to thermal and radiation stress is not additive, complicating lifetime prediction of cable performance based on sequential accelerated aging. In this work we explore the relative effects of simultaneous and sequential thermal and gamma radiation aging on cross-linked polyethylene (XLPE), which is commonly found in commercial nuclear power plants in the United States. Samples of XLPE were subjected to up to 320 kGy of gamma irradiation at a dose rate of 300 Gy/hr in two heating scenarios. In the first, simultaneously-aged samples were heated at 150°C during irradiation. In the second, sequentially aged samples were heated at 150°C for designated durations followed by corresponding periods of irradiation without heating. The mass, total color difference, and density were characterized to quantify aging of the insulation polymer. Sequential aging is hypothesized to be more damaging to XLPE insulation due to an increased trend in mass gain, total color difference, and density.

Cross-linked polyethylene, XLPE, nuclear cable, ac↗

Effect of Gamma Radiation on TaOₓ ECRAM

Electrochemical random access memory (ECRAM) is an emerging three-terminal nonvolatile memory (NVM) with highly controllable channel conductance which is promising for use as an analog memory (or synapse) in analog in-memory computing (IMC) systems. Energy-efficient analog IMC computing is particularly desirable for power-constrained, high-radiation environments such as satellites. However, little is known about the suitability of ECRAM for use in a total ionizing dose (TID) environment. Here, this work investigates the effect of Co-60 gamma radiation on the channel conductance and noise—two properties critical for analog IMC systems—of a TaO x -based ECRAM up to 17.3 Mrad(SiO 2 ) for both low- and high-channel-conductance state devices. A transient increase in conductance is observed in response to radiation which consists of two elements: an immediate increase in conductivity due to photocurrent and a secondary increase in conductivity, which has a slower rise and saturation and can persist for hours after exposure. This secondary, persistent photoconductivity is attributed to charging caused by hole trapping. These transient effects would not likely occur in a space environment due to the low dose rate compared with this experiment. No permanent change is found in the low conductance state (LCS) following exposure and the minor shift in the high conductance change would be less significant than the regular retention decay in this state. A permanent increase in the random telegraph noise is observed, possibly due to increased traps created in the channel. This work demonstrates that TaO x -based ECRAM is suitable for use in spaceborne analog IMC systems that are subject to significant TID.

ECRAM↗

Principal Component Analysis of Nuclear Cable Insulation Subjected to Elevated Temperature and Gamma Radiation

In nuclear power plants (NPPs), the aging of electrical cable insulation occurs due to elevated temperature, ionizing radiation, and other environmental factors. To ensure the safe and efficient operation of NPPs, determination of key indicators of cable aging is critical to predict the remaining useful lifetime of electrical cable insulation. In this work, the effects of simultaneous and sequential thermal and gamma radiation on the aging of cross-linked polyethylene (XLPE) electrical cable insulation are investigated. The chemical changes of the insulation were monitored non-destructively through the use of Fourier transform infrared (FTIR) spectroscopy. The FTIR spectra were measured stepwise after predetermined exposure intervals, with a total irradiation dose up to 320 kGy at a dose rate of 300 Gy/hr in two exposure scenarios; simultaneously aged samples were heated at 150 °C during irradiation, while sequentially aged samples were heated at 150 °C for designated durations followed by corresponding times of irradiation at ambient temperature. A data-driven approach using principal component analysis (PCA) was developed to highlight changes in the carbonyl region of the infrared spectra of the aged samples due to oxidation and to differentiate oxidation rates under the simultaneous and sequential exposure conditions. Findings indicate that the sequential aging scenario may be more conservative than the simultaneous aging scenario for XLPE electrical cable insulation.

Li, Donghui↗

Gamma-radiation-induced negative nonlinear absorption in quartz glass

The effect of ionizing radiation on the nonlinear optical properties of materials needs to be considered for applications that employ high-power laser pulses in extreme radiation environments. The Heraeus Infrasil302 optical quartz glass was irradiated by gamma rays, and its nonlinear absorption was measured using the open-aperture Z-scan technique with nanosecond laser pulses. Irradiation results in a negative nonlinear absorption coefficient whose magnitude increases with irradiation dose. Nonlinear absorption coefficients of -0.78, -1.14, -1.29, and -1.88~ × ~10 -13 m/W are measured for gamma doses of 600 krad, 1.2 Mrad, 3.6 Mrad, and 10 Mrad, respectively. Thermal annealing restores the optical properties of quartz-glass to their unirradiated values. It is suggested that metallic impurities introduced by the manufacturing process have a role in inducing saturated absorption in irradiated quartz glass, which manifests as negative nonlinear absorption coefficient, and is demonstrated by comparing Infrasil302 quartz results to equivalent irradiated measurements for Spectrosil2000 quartz.

07 ISOTOPE AND RADIATION SOURCES↗