Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gamma ray spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Identification and Suppression of Point Defects in Bromide Perovskite Single Crystals Enabling Gamma‐Ray Spectroscopy

Abstract Methylammonium lead tribromide (MAPbBr 3 ) stands out as the most easily grown wide‐band‐gap metal halide perovskite. It is a promising semiconductor for room‐temperature gamma‐ray ( γ ‐ray) spectroscopic detectors, but no operational devices are realized. This can be largely attributed to a lack of understanding of point defects and their influence on detector performance. Here, through a combination of crystal growth design and defect characterization, including positron annihilation and impedance spectroscopy, the presence of specific point defects are identified and correlated to detector performance. Methylammonium (MA) vacancies, MA interstitials, and Pb vacancies are identified as the dominant charge‐trapping defects in MAPbBr 3 crystals, while Br vacancies caused doping. The addition of excess MABr reduces the MA and Br defects and so enables the detection of energy‐resolved γ ‐ray spectra using a MAPbBr 3 single‐crystal device. Interestingly, the addition of formamidinium (FA) cations, which converted to methylformamidinium (MFA) cations by reaction with MA + during crystal growth further reduced MA defects. This enabled an energy resolution of 3.9% for the 662 keV 137 Cs line using a low bias of 100 V. The work provides direction toward enabling further improvements in wide‐bandgap perovskite‐based device performance by reducing detrimental defects.

Ni, Zhenyi↗

Application of the Approximate Bayesian Computation Algorithm to Gamma-Ray Spectroscopy

Radioisotope identification (RIID) algorithms for gamma-ray spectroscopy aim to infer what isotopes are present and in what amounts in test items. RIID algorithms either use all energy channels in the analysis region or only energy channels in and near identified peaks. Because many RIID algorithms rely on locating peaks and estimating each peak’s net area, peak location and peak area estimation algorithms continue to be developed for gamma-ray spectroscopy. This paper shows that approximate Bayesian computation (ABC) can be effective for peak location and area estimation. Algorithms to locate peaks can be applied to raw or smoothed data, and among several smoothing options, the iterative bias reduction algorithm (IBR) is recommended; the use of IBR with ABC is shown to potentially reduce uncertainty in peak location estimation. Extracted peak locations and areas can then be used as summary statistics in a new ABC-based RIID. ABC allows for easy experimentation with candidate summary statistics such as goodness-of-fit scores and peak areas that are extracted from relatively high dimensional gamma spectra with photopeaks (1024 or more energy channels) consisting of count rates versus energy for a large number of gamma energies.

Burr, Tom↗

Gamma-ray Spectroscopy in Low-Power Nuclear Research Reactors

Gamma-ray spectroscopy is an effective technique for radioactive material characterization, routine inventory verification, nuclear safeguards, health physics, and source search scenarios. Gamma-ray spectrometers typically cannot be operated in the immediate vicinity of nuclear reactors due to their high flux fields and their resulting inability to resolve individual pulses. Low-power reactor facilities offer the possibility to study reactor gamma-ray fields, a domain of experiments hitherto poorly explored. In this work, we present gamma-ray spectroscopy experiments performed with various detectors in two reactors: The EPFL zero-power research reactor CROCUS, and the neutron beam facility at the Ohio State University Research Reactor (OSURR). We employed inorganic scintillators (CeBr3), organic scintillators (trans-stilbene and organic glass), and high-purity germanium semiconductors (HPGe) to cover a range of typical—and new—instruments used in gamma-ray spectroscopy. The aim of this study is to provide a guideline for reactor users regarding detector performance, observed responses, and therefore available information in the reactor photon fields up to 2 MeV. The results indicate several future prospects, such as the online (at criticality) monitoring of fission products (like Xe, I, and La), dual-particle sensitive experiments, and code validation opportunities.

Pakari, Oskari V. (ORCID:0000000337048190)↗

MSIPP-NSSTC Course on Gamma Ray Spectroscopy – Part I

The presentation titled: "MSIPP-NSSTC Course on Gamma Ray Spectroscopy – Part I" to be presented as part of a course at UNLV for undergraduate/graduate students under the US DOE/NNSA sponsored MSIPP-NSSTC program

61 RADIATION PROTECTION AND DOSIMETRY↗

Gamma-ray spectroscopy using angular distribution of Compton scattering

We present a novel method to perform gamma-ray spectroscopy suitable for extreme pileup situations, wherein traditional pulse-height spectroscopy is infeasible or impractical. One example of such application is spectral characterization of intense laser-based radiation sources that employ laser wakefield acceleration, in which a large number of photons can be produced in a well-collimated beam on a picosecond or shorter timescale. The method relies on the angularly-resolved calorimetric measurement of Compton scattering. The probability for a photon to undergo Compton scattering into a given solid angle is a function of its energy and is described by the Klein–Nishina formula. By first Compton scattering the incident beam and then measuring the total energies deposited in multiple detectors placed at various scattering angles, the incident beam energy spectrum can be reconstructed without resolving the individual events in detectors. Here, we compare the performance of an maximum likelihood expectation maximization algorithm with that of an artificial neural network to measure the energy spectrum of a beam of monoenergetic gamma rays from 137Cs decay. We demonstrate that the method can be used to reconstruct the characteristic inverse Compton scattering spectra.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cumulative fission yields of short-lived fission products from 235 U and 239 Pu measured by HPGe gamma-ray spectroscopy

In this study, we present a preliminary investigation focused on determining cumulative fission yields for short-lived fission products. Our analysis involves examining gamma spectra from the irradiated samples of 235 U and 239 Pu using the High Flux Isotope Reactor. The motivation stems from the observed discrepancy in the antineutrino energy spectrum within the range of 5 to 7 MeV. While several hypotheses have been proposed, a thorough analysis of fission yields provides an additional way of gaining insight into this unexplained phenomenon. Our study suggests that the measured gamma rays from 100 Nb, 140 Cs and 95 Sr are consistent with the expected values. However, 93 Rb, 96 Y, 97 Y and 142 Cs cannot be quantified due to insufficient statistics, interference from other gamma rays and the Compton scattering background. Additionally, the calculated cumulative fission yields based on the measured 140 Cs and 95 Sr are found to be consistent with the JEFF3.3 fission yield library. In conclusion, the present work shows that the potential of improving gamma-ray spectroscopy in the fission yields as a means to improve our understanding of the antineutrino spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Results for Gamma-Ray Spectroscopy Characterization of Residual Radioactivity on Personal Protective Clothing

In early 2019, Health Physics Services (HPS) personnel put together a test plan to use the shielded gamma-ray spectroscopy instruments in the Health Physics Services Technical Laboratory (HPSTL) to perform a series of measurements on laundered personal protective clothing used in radiological areas at the Savannah River Site (SRS). That test plan describes the methodology used to determine the quantities of laundry to be obtained from operational facilities, the methods for quality control checking the instruments throughout the measurement period, and the physical arrangement of samples in the counting shields. The test plan is documented in SRNS-J6700-2019-00037 (Reference 1).

61 RADIATION PROTECTION AND DOSIMETRY↗

Holistic digital gamma-ray spectroscopy methods and instrumentation for high-throughput high-resolution applications

Method of real-time adaptive digital pulse signal processing for high count rate gamma-ray spectroscopy applications includes receiving a preamplifier signal at a pulse deconvolver, the preamplifier signal including resolution deterioration resulting from pulse pile-up. The method further includes generating a deconvoluted signal, by the pulse deconvolver, from the preamplifier signal, the deconvoluted signal having less resolution deterioration as compared to the received preamplifier signal. The method furthermore includes shaping of the deconvoluted signal by a trapezoid filter, the shaping comprising adjusting a shaping parameter of the trapezoid filter for an incoming signal based on a time separation from a subsequent incoming signal.

Hawari, Ayman I.↗

Triple-mode detector for fast neutrons, slow neutrons, and gamma ray spectroscopy

This disclosure provides systems, methods, and apparatus related to neutron detection and gamma ray detection. In one aspect, a detector comprises a scintillator structure that comprises an organic scintillator and an inorganic scintillator. The organic scintillator is in the form of one or more elements of a specified length. The inorganic scintillator is in the form of one or more elements of the specified length. First ends of the one or more organic scintillator elements and first ends of the one or more inorganic scintillator elements define a first surface. Second ends of the one or more organic scintillator elements and second ends of the one or more inorganic scintillator elements define a second surface.

Derenzo, Stephen↗

Multi-pulse time resolved gamma ray spectroscopy of the advanced radiographic capability using gas Cherenkov diagnostics

The advanced radiographic capability located at the National Ignition Facility (NIF) uses high intensity, short pulse lasers to create bright photon sources for diagnosing high energy density experiments. There are radiographic needs for a multi-frame time-resolved MeV gamma diagnostic for experiments on the NIF with sub-nanosecond resolution. A series of experiments demonstrated measurements of MeV x-ray spectra resolved with a time separation of a few nanoseconds through the use of gas Cherenkov detectors. In this work, a two-pulse radiographic experiment found a 30% reduction in > 2.8 MeV photon flux compared to the first frame exposure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Discrimination of phosgene from cyanogen chloride in recovered chemical munitions using tagged neutron interrogation with high-resolution gamma-ray spectroscopy

The Associated Particle technique has recently been utilized with a germanium-based high-resolution $\gamma$-ray spectrometer and assessed for its capability to improve field identification of recovered chemical warfare (CW) materiel through prompt gamma-ray neutron activation analysis (PGNAA) measurements. An accurate chemical identification is necessary for the safe handling, destruction, and disposal of such hazardous items. A particularly challenging pair of CW agents commonly found in recovered munitions are phosgene (CG) and cyanogen chloride (CK), which have two of three elements in common, i.e. chlorine and carbon, but differ in the third being either oxygen or nitrogen. The detection of both latter elements is complicated by high oxygen concentration in the field environment which interferes with the small signal produced from the chemical agents. The matter is further complicated by the precautionary field practice of overpacking recovered munitions with vermiculite in larger steel multiple round containers (MRCs), which places additional oxygen-rich material around the munition while further attenuating an already weak signal emitted from the munition center. Here, this work reports quantitative results from realistic field measurements of CG and CK simulants in mock 4.2-inch mortar rounds overpacked with vermiculite in a large MRC. Results obtained with the AP technique are compared to those obtained with the traditional PGNAA approach for both overpacked- and bare-munition measurements. The AP technique is shown to provide a much more confident discrimination between the two chemicals, particularly for the more challenging field-relevant overpacked measurements, where a significant gain in sensitivity to all the key elements chlorine, carbon, nitrogen and oxygen is achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A fi eld-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt gamma-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium gamma-ray detector. Fine spatial resolution neutron and alpha detectors enable precise mapping of characteristic gamma-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus signifi cantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Improved field assessments of chemicals and explosives using high-resolution gamma-ray spectroscopy with a tagged neutron interrogation system

A fi eld-portable tagged neutron interrogation system is being developed for detection of explosives and chemical warfare agents by prompt gamma-ray neutron activation analysis. The system combines an associated particle imaging deuterium-tritium neutron generator with a high-purity germanium gamma-ray detector. Fine spatial resolution neutron and alpha detectors enable precise mapping of characteristic gamma-ray emission distributions onto high-clarity neutron radiographic images. A narrow coincidence gate associated with each tagged neutron ensures a large signal-to-background ratio, thus signifi cantly improving sensitivity to the chemical compositions of the items being assessed. Recent experimental results recorded from test objects involving mock explosives and other chemicals are presented.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

In-beam $$\gamma $$-ray spectroscopy of $$^{94}$$Ag

Abstract A recoil-beta-tagging experiment has been performed to study the excited $$T=0$$ T = 0 and $$T=1$$ T = 1 states in the odd–odd $$N=Z$$ N = Z nucleus $$^{94}$$ 94 Ag, populated via the $$^{40}$$ 40 Ca( $$^{58}$$ 58 Ni,1p3n) $$^{94}$$ 94 Ag reaction. The experiment was conducted using the MARA recoil separator and JUROGAM3 array at the Accelerator Laboratory of the University of Jyväskylä. Through correlating fast, high-energy beta decays at the MARA focal plane with prompt $$\gamma $$ γ rays emitted at the reaction target, a number of transitions between excited states in $$^{94}$$ 94 Ag have been identified. The timing characteristics of these transitions confirm that they fall within decay sequences that feed the short-lived $$T=1$$ T = 1 ground state of $$^{94}$$ 94 Ag. The transitions are proposed to proceed within and between the sets of states with $$T=0$$ T = 0 and $$T=1$$ T = 1 . Possible correspondence between some of these transitions from analog states in $$^{94}$$ 94 Pd has been discussed, and shell-model calculations including multipole and monopole electromagnetic effects have been presented, in order to enable predictions of the decay patterns between the $$T=0$$ T = 0 and $$T=1$$ T = 1 states and to allow a theoretical set of Coulomb energy differences to be calculated for the $$A = 94$$ A = 94 $$T=1$$ T = 1 analog states.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗