Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gas Tagging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of a Molecular Tagging Velocimetry Technique for Non-Intrusive Velocity Measurements in Low-Speed Gas Flows

N2O molecular tagging velocimetry (N2O-MTV) is developed for use in very-high-temperature reactor environments. Tests were carried out to determine the optimum excitation wavelength, tracer concentration, and timing parameters for the laser system. Using NO tracers obtained from photo-dissociation of N2O, velocity profiles are successfully obtained in air, nitrogen, and helium for a large range of parameters: temperature from 295 to 781 K, pressure from 1 to 3 bars, with a velocity precision of 0.01 m/s. Furthermore, by using two read pulses at adjustable time delays, the velocity dynamic range can be increased. An unprecedented dynamic range of 5,000 has been obtained to successfully resolve the flow during a helium blowdown from 1000 m/s down to 0.2 m/s. This technique is also applied to the high-temperature test facility (HTTF) at Oregon State University (OSU) during a depressurized condition cooldown (DCC) event. Details of these measurements are presented in a companion paper. This technique shows a strong potential for fundamental understanding of gas flows in nuclear reactors and to provide benchmark experimental data to validate numerical simulations.

Andre, M. A.↗

Viking on Mars - A preliminary survey

Selection of landing site, observations of Martian topography from orbit, a log of entry into the Martian atmosphere and landing operations, and soil experiments executed at the landing site are recounted. Several photographs overviewing Martian terrain from orbit (1600 to 1900 km up) are shown. Soil sampling and analysis experiments and experiments designed to detect biotic activity (pyrolysis, labeled release of 14-carbon-tagged CO2, gas exchange and vapor chromatography, pyrolytic release) are described and some preliminary results reported. Results on surface geology and chemical composition of the Martian atmosphere are cited.

Young, R. S.↗

Laser diagnostics for microgravity droplet studies

Rapid advances have recently been made in numerical simulation of droplet combustion under microgravity conditions, while experimental capabilities remain relatively primitive. Calculations can now provide detailed information on mass and energy transport, complex gas-phase chemistry, multi-component molecular diffusion, surface evaporation and heterogeneous reaction, which provides a clearer picture of both quasi-steady as well as dynamic behavior of droplet combustion. Experiments concerning these phenomena typically result in pictures of the burning droplets, and the data therefrom describe droplet surface regression along with flame and soot shell position. With much more precise, detailed, experimental diagnostics, significant gains could be made on the dynamics and flame structural changes which occur during droplet combustion. Since microgravity experiments become increasingly more expensive as they progress from drop towers and flights to spaceborne experiments, there is a great need to maximize the information content from these experiments. Sophisticated measurements using laser diagnostics on individual droplets and combustion phenomena are now possible. These include measuring flow patterns and temperature fields within droplets, vaporization rates and vaporization enhancement, radical species profiling in flames and gas-phase flow-tagging velocimetry. Although these measurements are sophisticated, they have undergone maturation to the degree where with some development, they are applicable to studies of microgravity droplet combustion. This program beginning in September of 1992, will include a series of measurements in the NASA Learjet, KC-135 and Drop Tower facilities for investigating the range of applicability of these diagnostics while generating and providing fundamental data to ongoing NASA research programs in this area. This program is being conducted in collaboration with other microgravity investigators and is aimed toward supplementing their experimental efforts.

Winter, Michael↗

Femtosecond Laser Tagging in 1,1,1,2-Tetrauoroethane with Trace Quantities of Air

Femtosecond laser tagging is demonstrated for the first time in R134a gas, and in mixtures of R134a with small quantities of air. A systematic study of this tagging method is explored through the adjustment of gas pressure, mixture ratio and laser properties. It is found that the signal strength and lifetime are greatest at low pressures for excitation at both the 400 nm and 800 nm laser wavelengths. The relative intensities of two spectral peaks in the near-UV emission change as a function of gas pressure and can potentially be used for local pressure measurements. Single shot precision in pure R134a and R134a with 5% air is demonstrated at the exit of a subsonic pipe flow. The parameter space of these results are chosen to mimic conditions used in the NASA Langley Research Center's Transonic Dynamics Tunnel. The precision and signal lifetime demonstrate the feasibility of using this technique for measuring flowfields that induce airfoil utter.

Zhang, Yibin↗

Investigation of the feasibility of optical diagnostic measurements at the exit of the SSME

Under Contract NAS8-36861 sponsored by NASA Marshall Space Flight Center, the United Technologies Research Center is conducting an investigation of the feasibility of remote optical diagnostics to measure temperature, species concentration and velocity at the exit of the Space Shuttle Main Engine (SSME). This is a two phase study consisting of a conceptual design phase followed by a laboratory experimental investigation. The first task of the conceptual design studies is to screen and evaluate the techniques which can be used for the measurements. The second task is to select the most promising technique or techniques, if as expected, more than one type of measurement must be used to measure all the flow variables of interest. The third task is to examine in detail analytically the capabilities and limitations of the selected technique(s). The results of this study are described in the section of this report entitled Conceptual Design Investigations. The conceptual design studies identified spontaneous Raman scattering and photodissociative flow-tagging for measurements respectively of gas temperature and major species concentration and for velocity. These techniques and others that were considered are described in the section describing the conceptual design. The objective of the second phase of investigations was to investigate experimentally the techniques identified in the first phase. The first task of the experimental feasibility study is to design and assemble laboratory scale experimental apparatus to evaluate the best approaches for SSME exit optical diagnostics for temperature, species concentrations and velocity, as selected in the Phase I conceptual design study. The second task is to evaluate performance, investigate limitations, and establish actual diagnostic capabilities, accuracies and precision for the selected optical systems. The third task is to evaluate design requirements and system trade-offs of conceptual instruments. Spontaneous Raman scattering excited by a KrF excimer laser pulse was investigated for SSME exit plane temperature and major species concentration measurements. The relative concentrations of molecular hydrogen and water vapor would be determined by measuring the integrated Q-branch scattering signals through narrow bandpass filters in front of photomultipliers. The temperature would be determined by comparing the signal from a single hydrogen rotational Raman line to the total hydrogen Q-branch signal. The rotational Raman line would be isolated by a monochromator and detected with a PMT.

Shirley, John A.↗

A search for noble-gas evidence for presolar oxide grains

Early results from an ongoing search for isotopically distinctive noble gases as evidence for presolar oxide grains are presented. With some qualifications, we do not see such evidence in spinel rich acid residue fractions from the Allende meteorite. We remain hopeful that less abundant mineral separates may yet be fruitful. Presolar grains, micro-diamonds, silicon carbide, and graphite, were found in primitive meteorites. While the abundances of these three refractory C rich grains are low, a few hundred ppm, a few ppm, & less than 1 ppm, respectively in primitive meteorites, they are tagged with high concentrations of isotopically anomalous noble gas components, Xe-HL, KR & Xe-s and Ne-E(H), and Ne-E(L). These tags have served as tracers and allowed the development of techniques for their purification and eventual identification. One might expect similar amounts of refractory presolar oxides to have survived, but so far only three cases exist for their identification. The first two cases are individual corundum oxide grains. Huss et al. found one such grain from an Orgueil residue with an Al-26/Al-27 ratio of 8.9 x 10(exp -5), about 18 times higher than the canonical initial solar system value. The second corundum grain, from Murchison, was found by Nittler et al. to have unusual oxygen in addition to a similar Al-26/Al-27 ratio of 8.7 x 10(exp -4). The oxygen was depleted in O-18 by 22 percent and enriched in O-17 by a factor of 2. The third case is a measurement by Zinner et al. on an aggregate of fine grained spinels from a Murray residue with an O-17 enrichment and a possible O-18 depletion similar to the second grain, but much subdued. This is consistent with a few such presolar grains diluted by a much larger population of isotopically normal corundum grains and an even larger number of normal spinel grains.

Lewis, Roy S.↗

Imaging Proportional X-ray Counter for HEAO

The HEAO-B Imaging Proportional Counter (IPC) is an X-ray imaging instrument designed for use in the High Energy Astronomy Observatory - Mission B (HEAO-B) X-ray Telescope. It measures the spatial location of individual X-ray photons by the risetime method and energy of photons by pulse height analysis. The IPC can locate photons in the energy range 0.2 to 4 keV to within 1 mm and provides 5 bits of energy level information. Each measured X-ray event is also time tagged with 7 bits of temporal data. The IPC also includes an in-flight-calibration source and uses a gas control system that maintains the counter gas density constant to an accuracy of 0.25 percent.

Humphrey, A.↗

Next-generation wildlife tracking devices and integrated sensors for measuring species-environment interactions and advancing conservation

Global land use and climate change have magnified the importance of collecting accurate animal movement and environmental data to improve our ability to model species interactions with the environment and promote effective conservation. Advanced animal tracking devices that couple cutting-edge technologies with our expanding need for ecological information is critical. In addition to further optimizing device size to monitor small, sensitive species, new paradigms for collecting, storing, and transmitting data about animals and their environments will propel wildlife tracking devices forward. Advanced telemetry capabilities will increase our ability to pair location and sensor data from tagged wildlife with remote sensing data. The USGS Western Ecological Research Center, NASA Ames Research Center, and collaborators have been developing new wildlife tracking devices and integrated environmental sensors to address these challenges. We describe a new, miniaturized solar GPS-enabled Globalstar satellite transmitter with accelerometer capability that is 20% lighter and 25% less expensive than existing commercially available tags. We also introduce a novel peer-to-peer, solar-powered network tag that uses long-range, low-power, wireless platform technology. Concurrently, we began adapting a carbon nanotube (CNT) sensor to detect dimethyl sulfide (DMS), a trace gas relevant to marine ecology and climate studies. CNT sensors offer a small, lightweight, and low-power technology that can detect changes in resistance across carbon nanotubes coated with adsorbent selected to specifically bind with a variety of reactive trace gasses. We flew a prototype sensor in a small UAS and sampled an apparent increase in DMS concentration consistent with a well-defined marine frontal boundary. Currently we are integrating project components to create a hybridized architecture of networked peer-to-peer and satellite tags with integrated CNT and additional on-board and remote sensors to advance animal tracking and to provide information for next generation wildlife conservation.

Ian G. Brosnan↗

Cellular automaton formulation of passive scalar dynamics

Cellular automata modeling of the advection of a passive scalar in a two-dimensional flow is examined in the context of discrete lattice kinetic theory. It is shown that if the passive scalar is represented by tagging or 'coloring' automation particles a passive advection-diffusion equation emerges without use of perturbation expansions. For the specific case of the hydrodynamic lattice gas model of Frisch et al. (1986), the diffusion coefficient is calculated by perturbation.

Chen, Hudong↗

Molecular Tagging Velocimetry Development for In-situ Measurement in High-Temperature Test Facility

The High Temperature Test Facility, HTTF, at Oregon State University (OSU) is an integral-effect test facility designed to model the behavior of a Very High Temperature Gas Reactor (VHTR) during a Depressurized Conduction Cooldown (DCC) event. It also has the ability to conduct limited investigations into the progression of a Pressurized Conduction Cooldown (PCC) event in addition to phenomena occurring during normal operations. Both of these phenomena will be studied with in-situ velocity field measurements. Experimental measurements of velocity are critical to provide proper boundary conditions to validate CFD codes, as well as developing correlations for system level codes, such as RELAP5 (http://www4vip.inl.gov/relap5/). Such data will be the first acquired in the HTTF and will introduce a diagnostic with numerous other applications to the field of nuclear thermal hydraulics. A laser-based optical diagnostic under development at The George Washington University (GWU) is presented; the technique is demonstrated with velocity data obtained in ambient temperature air, and adaptation to high-pressure, high-temperature flow is discussed.

Andre, Matthieu A.↗

The Comet Astrobiology Exploration Sample Return (CAESAR) Mission

The Comet Astrobiology Exploration Sample Return (CAESAR) mission will acquire and return to Earth for laboratory analysis a minimum of 80 grams of surface material from the nucleus of comet 67P/Chur-yumov-Gerasimenko (67P). CAESAR will characterize the surface region sampled, preserve the collected sample in a pristine state, and return evolved volatiles by capturing them in a separate gas reservoir. NASA Goddard Space Flight Center provides project management, systems engineering, safety and mission assurance, contamination control, mission operations, and many other important functions. Northrop Grumman Space Systems will build the spacecraft, based on Dawn mission heritage, which like CAESAR, uses solar electric propulsion. CAESAR was selected by for Phase A study in the New Frontiers 4 Competition and will be proposed to New Frontiers 5.Collection of a sample from the surface of comet 67P is facilitated by a set of cameras that together provide images to support sample site selection, perform optical navigation, and document the sample before, during, and after col-lection. The sample is collected at the end of an arm during a 5-second touch-and-go (TAG) maneuver with the Sample Acquisition System (SAS)designed by Honeybee Robotics for the surface properties of comet 67P observed by the Rosetta mission. After sample collection, and while the sample is still cold (< -80°C), the TAG Arm inserts the sample container into the Sample Containment System (SCS) mounted inside the Sample Return Capsule (SRC). The SCS is sealed, preventing the sample from escaping into space. The sample is slowly warmed inside the SCS to enable sublimation of volatiles, which are collected in the Gas Containment System (GCS), a passively cooled gas reservoir. Separating the volatiles from the solid sample protects the solid sample from alteration. Once all sublimated H2O is transferred to the GCS, the GCS is sealed to capture the volatile sit contains, and the SCS is vented to space to maintain the solid sample under vacuum. The SCS vent is closed before Earth entry to prevent atmospheric contamination. Detailed laboratory analyses of the sample from 67P will trace the history of volatile reservoirs, delineate the chemical pathways that led from simple interstellar species to complex molecules, constrain the evolution of the comet, and evaluate the role of comets in delivering water and prebiotic organics to the early Earth. CAESAR will achieve these goals by carrying out coordinated sample analyses that will link macroscopic properties of the comet with microscale mineralogy, chemistry, and isotopic studies of volatiles and solids. Most of the sample (≥75%) will be set aside for analyses by generations of scientists using continually advancing tools and methods, yielding an enduring scientific treasure that only sample return can provide. This presentation will review development conducted during NF4 Phase A and discuss the NF5 mission concept.

A G Hayes↗

Gas Supersaturation May Reduce the Survival of Yearling Chinook Salmon in the Lower Columbia River and Ocean Plume

Unusually high flows in the Columbia River in 2011 raised total dissolved gas (TDG) levels in the river above the 120 percent legal limit imposed to prevent harmful impacts to aquatic organisms. This provided a unique opportunity to evaluate the effect on smolt survival. In-river (IR) migrating juvenile yearling Chinook released at Bonneville Dam with acoustic tags during periods when TDG exceeded 120 percent received estimated maximum exposures of 134 TDG. Subsequent daily survival rates in the lower river and plume were reduced by 0.06 per day (SE equals 0.01) and 0.15 per day (SE equals 0.05) relative to IR migrant fish released when TDG was less than 120 percent. Transported smolts (T) released 10-13 kilometers below Bonneville Dam had lower maximum exposure levels (126 percent) and experienced no difference in daily survival rates relative to unexposed smolts. River temperature levels and trends in turbidity and disease prevalence between releases of high and low exposure smolts were not consistent with the observed effects on survival rates. We conclude that smolts may suffer from chronic effects of elevated TDG exposure while migrating through the Columbia River and plume. Consideration should be given to measuring these survival losses in an explicit experimental framework that isolates possible confounding factors.

survival↗

Particle Image Velocimetry Applications Using Fluorescent Dye-Doped Particles

Polystyrene latex sphere particles are widely used to seed flows for velocimetry techniques such as Particle Image Velocimetry (PIV) and Laser Doppler Velocimetry (LDV). These particles may be doped with fluorescent dyes such that signals spectrally shifted from the incident laser wavelength may be detected via Laser Induced Fluorescence (LIF). An attractive application of the LIF signal is achieving velocimetry in the presence of strong interference from laser scatter, opening up new research possibilities very near solid surfaces or at liquid/gas interfaces. Additionally, LIF signals can be used to tag different fluid streams to study mixing. While fluorescence-based PIV has been performed by many researchers for particles dispersed in water flows, the current work is among the first in applying the technique to micron-scale particles dispersed in a gas. A key requirement for such an application is addressing potential health hazards from fluorescent dyes; successful doping of Kiton Red 620 (KR620) has enabled the use of this relatively safe dye for fluorescence PIV for the first time. In this paper, basic applications proving the concept of PIV using the LIF signal from KR620-doped particles are exhibited for a free jet and a twophase flow apparatus. Results indicate that while the fluorescence PIV techniques are roughly 2 orders of magnitude weaker than Mie scattering, they provide a viable method for obtaining data in flow regions previously inaccessible via standard PIV. These techniques have the potential to also complement Mie scattering signals, for example in multi-stream and/or multi-phase experiments.

Petrosky, Brian J.↗

Part Marking and Identification Materials' for MISSE

The Materials on International Space Station Experiment (MISSE) is being conducted with funding from NASA and the U.S. Department of Defense, in order to evaluate candidate materials and processes for flight hardware. MISSE modules include test specimens used to validate NASA technical standards for part markings exposed to harsh environments in low-Earth orbit and space, including: atomic oxygen, ultraviolet radiation, thermal vacuum cycling, and meteoroid and orbital debris impact. Marked test specimens are evaluated and then mounted in a passive experiment container (PEC) that is affixed to an exterior surface on the International Space Station (ISS). They are exposed to atomic oxygen and/or ultraviolet radiation for a year or more before being retrieved and reevaluated. Criteria include percent contrast, axial uniformity, print growth, error correction, and overall grade. MISSE 1 and 2 (2001-2005), MISSE 3 and 4 (2006-2007), and MISSE 5 (2005-2006) have been completed to date. Acceptable results were found for test specimens marked with Data Matrix(TradeMark) symbols by Intermec Inc. and Robotic Vision Systems Inc using: laser bonding, vacuum arc vapor deposition, gas assisted laser etch, chemical etch, mechanical dot peening, laser shot peening, laser etching, and laser induced surface improvement. MISSE 6 (2008-2009) is exposing specimens marked by DataLase(Registed TradeMark), Chemico technologies Inc., Intermec Inc., and tesa with laser-markable paint, nanocode tags, DataLase and tesa laser markings, and anodized metal labels.

Roxby, Donald↗

The thermoelectric generator test program at JPL.

Discussion of the test results and analysis performed on data obtained from eight thermoelectric generators exhibiting a total combined operating time of about 21 years. Three (3) SNAP-19 type generators are discussed. Generator SN-20, the engineering model of the units presently operating on the Nimbus S/C, has been in operation for over 4 years and has shown drastic degradation after losing the internal cover gas. Generator SN-21, with more than four years of operating time, is operated in an air environment. The performance of this generator appears predictable and stable. For the last 2 years of operation generator degradation has been negligible. Generator SN-31, which utilizes the TAGS material for the P thermoelectric leg, is similar in design to the units to be used on the Pioneer S/C and has operated for over two years in an all-argon atmosphere.

Stapfer, G.↗

Multiparameter Flowfield Measurements in High-Pressure, Cryogenic Environments Using Femtosecond Lasers

Femtosecond laser electronic excitation tagging (FLEET) and Rayleigh scattering (RS) from a femtosecond laser are demonstrated in the NASA Langley 0.3-m Transonic Cryogenic Tunnel (TCT). The measured signals from these techniques are examined for their thermodynamic dependencies in pure nitrogen. The FLEET signal intensity and signal lifetimes are found to scale primarily with the gas density, as does the RS signal. Several models are developed, which capture these physical behaviors. Notably, the FLEET and Rayleigh scattering intensities scale linearly with the flow density, while the FLEET signal decay rates are a more complex function of the thermodynamic state of the gas. The measurement of various flow properties are demonstrated using these techniques. While density was directly measured from the signal intensities and FLEET signal lifetime, temperature and pressure were measured using the simultaneous FLEET velocity measurements while assuming the flow had a constant total enthalpy. Measurements of density, temperature, and pressure from the FLEET signal are made with accuracies as high as 5.3 percent, 0.62 percent, and 6.2 percent, respectively, while precisions were approximately 10 percent, 0.26 percent, and 11 percent for these same quantities. Similar measurements of density from Rayleigh scattering showed an overall accuracy of 3.5 percent and a precision of 10.2 percent over a limited temperature range (T greater than 195 K). These measurements suggest a high degree of utility at using the femtosecond-laser based diagnostics for making multiparameter measurements in high-pressure, cryogenic environments such as large-scale TCT facilities.

Burns, Ross A.↗

FLEET and PLIF Velocimetry Within A Mach 10 Hypersonic Air Flow

Femtosecond laser electronic excitation tagging (FLEET) and planar laser-induced fluorescence (PLIF) velocity measurements utilizing molecular tagging velocity (MTV) methods from three recent test campaigns conducted at the 31-in Mach 10 Air Tunnel at the NASA Langley Research Center are highlighted within. The FLEET measurements reported here include the first direct measurement of freestream velocity at this hypersonic wind tunnel facility. Measurement challenges were exasperated by the low gas density of the Mach 10 air freestream (~0.4% of standard temperature and pressure conditions) and even lower gas densities within the hypersonic wake of a 70-degree sphere-cone model. In addition, the hypersonic freestream and very low speed velocities in the wake also tested the measurement dynamic range. To complement the FLEET measurements in the wake of the sphere-cone model, PLIF velocimetry using seeded nitric oxide was also performed. While NO-PLIF velocimetry has been performed at this facility several times by previous researchers, the use of a 1D diffractive optical element for NO-PLIF velocimetry is reported here for the first time. The 1D DOE enabled the generation of up to 75 laser lines simultaneously and improved the spatial extent of the measurement three times compared to previous work. This enabled a wide velocity measurement plane of approximately 130 mm x 130 mm. The velocimetry methods demonstrated here are expected to improve wind tunnel characterization, provide critical data to validate CFD codes, and improve the design of flight vehicles for planetary entry.

FLEET↗

FLEET and PLIF Velocimetry Within A Mach 10 Hypersonic Air Flow

Femtosecond laser electronic excitation tagging (FLEET) and planar laser-induced fluorescence (PLIF) velocity measurements utilizing molecular tagging velocity (MTV) methods from three recent test campaigns conducted at the 31-in Mach 10 Air Tunnel at the NASA Langley Research Center are highlighted within. The FLEET measurements reported here include the first direct measurement of freestream velocity at this hypersonic wind tunnel facility. Measurement challenges were exasperated by the low gas density of the Mach 10 air freestream (~0.4% of standard temperature and pressure conditions) and even lower gas densities within the hypersonic wake of a 70-degree sphere-cone model. In addition, the hypersonic freestream and very low speed velocities in the wake also tested the measurement dynamic range. To complement the FLEET measurements in the wake of the sphere-cone model, PLIF velocimetry using seeded nitric oxide was also performed. While NO-PLIF velocimetry has been performed at this facility several times by previous researchers, the use of a 1D diffractive optical element for NO-PLIF velocimetry is reported here for the first time. The 1D DOE enabled the generation of up to 75 laser lines simultaneously and improved the spatial extent of the measurement three times compared to previous work. This enabled a wide velocity measurement plane of approximately 130 mm x 130 mm. The velocimetry methods demonstrated here are expected to improve wind tunnel characterization, provide critical data to validate CFD codes, and improve the design of flight vehicles for planetary entry.

FLEET↗