Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gas chromatography.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Identification of Explosives from Porous Materials: Applications Using Reverse Phase High Performance Liquid Chromatography and Gas Chromatography

High performance liquid chromatography and gas chromatography techniques are well documented and widely used for the detection of trace explosives from organic solvents. These techniques were modified to specifically identify and quantify explosives extracted from various materials taken from people who had recently handled explosives. Documented techniques were modified to specifically detect and quantify RDX, TNT, and PETN from denim, colored flannel, vinyl, and canvas extracted in methanol using no sample cleanup prior to analysis. The methanol extracts were injected directly into several different column types and analyzed by HPLC-UV and/or GC-ECD. This paper describes general screening methods that were used to determine the presence of explosives in unknown samples and techniques that have been optimized for quantification of each explosive from the substrate extracts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

HDT mixtures treatment strategies by gas chromatography

Gas phase chromatographic processes are of interest for the separation of hydrogen isotopes from an HDT mixture. For a certain quantity, they are very competitive and present several benefits. Nevertheless no active packing material allows to have simultaneously good enrichment performances for tritium production and high decontamination capabilities for HD gases. The influence of the packing material is first described in this article. Then two specific processes (TCAP and Reverse Chromatography), each well adapted to perform one target, are presented. Finally, the problematic to propose an optimized treatment scheme associating these two processes is formulated. (authors)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Monitoring of CoS 2 reactions using high-temperature XRD coupled with gas chromatography (GC)

High-temperature X-ray diffraction with concurrent gas chromatography (GC) was used to study cobalt disulfide cathode pellets disassembled from thermal batteries. When CoS 2 cathode materials were analyzed in an air environment, oxidation of the K(Br, Cl) salt phase in the cathode led to the formation of K 2 SO 4 that subsequently reacted with the pyrite-type CoS 2 phase leading to cathode decomposition between ~260 and 450 °C. Here, independent thermal analysis experiments, i.e. simultaneous thermogravimetric analysis/differential scanning calorimetry/mass spectrometry (MS), augmented the diffraction results and support the overall picture of CoS 2 decomposition. Both gas analysis measurements (i.e. GC and MS) from the independent experiments confirmed the formation of SO 2 off-gas species during breakdown of the CoS 2 . In contrast, characterization of the same cathode material under inert conditions showed the presence of CoS 2 throughout the entire temperature range of analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative Analysis of Tetramethylenedisulfotetramine ("Tetramine") Spiked into Beverages by Liquid Chromatography Tandem Mass Spectrometry with Validation by Gas Chromatography Mass Spectrometry

Tetramethylenedisulfotetramine, commonly known as tetramine, is a highly neurotoxic rodenticide (human oral LD{sub 50} = 0.1 mg/kg) used in hundreds of deliberate food poisoning events in China. Here we describe a method for quantitation of tetramine spiked into beverages, including milk, juice, tea, cola, and water and cleaned up by C8 solid phase extraction and liquid-liquid extraction. Quantitation by high performance liquid chromatography tandem mass spectrometry (LC/MS/MS) was based upon fragmentation of m/z 347 to m/z 268. The method was validated by gas chromatography mass spectrometry (GC/MS) operated in SIM mode for ions m/z 212, 240, and 360. The limit of quantitation was 0.10 {micro}g/mL by LC/MS/MS versus 0.15 {micro}g/mL for GC/MS. Fortifications of the beverages at 2.5 {micro}g/mL and 0.25 {micro}g/mL were recovered ranging from 73-128% by liquid-liquid extraction for GC/MS analysis, 13-96% by SPE and 10-101% by liquid-liquid extraction for LC/MS/MS analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Non-planar microfabricated gas chromatography column

A non-planar microfabricated gas chromatography column comprises a planar substrate having a plurality of through holes, a top lid and a bottom lid bonded to opposite surfaces of the planar substrate, and inlet and outlet ports for injection of a sample gas and elution of separated analytes. A plurality of such planar substrates can be aligned and stacked to provide a longer column length having a small footprint. Furthermore, two or more separate channels can enable multi-channel or multi-dimensional gas chromatography. The through holes preferably have a circular cross section and can be coated with a stationary phase material or packed with a porous packing material. Importantly, uniform stationary phase coatings can be obtained and band broadening can be minimized with the circular channels. A heating or cooling element can be disposed on at least one of the lids to enable temperature programming of the column.

47 OTHER INSTRUMENTATION↗

Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry

Two-dimensional gas chromatography coupled with time of flight mass spectrometry is a powerful tool for identifying and quantifying components in complex mixtures. It has been used to analyze gasoline, jet fuel, diesel, bio-diesel and organic fraction of bio-crude/bio-oil. In these experiments, the first dimension of separation was non-polar, followed by a polar separation. Aqueous fractions of bio-crude and other aqueous samples have been examined with similar column combinations. However, sample preparation techniques such as derivatization, solvent extraction, and solid-phase extraction were necessary prior to analysis. In this study, aqueous fraction obtained from hydrothermal liquefaction of algae was characterized by two-dimensional gas chromatography coupled with time of flight mass spectrometry without prior sample preparation techniques using a polar separation in the first dimension followed by a non-polar separation. Two-dimensional plots from this analysis were compared with those obtained from the more traditional column combination. Results from qualitative characterization aqueous fractions of algal bio-crude are discussed in detail. The advantages of using a polar separation followed by a non-polar separation for characterization of organics in aqueous samples by two-dimensional gas chromatography coupled with time of flight mass spectrometry are highlighted.

aquatic biomass↗

Characterization of the aqueous fraction from hydrothermal liquefaction of algae using 2D gas chromatography with time-of-flight mass spectrometry

Two-dimensional gas chromatography coupled with time of flight mass spectrometry is a powerful tool for identifying and quantifying components in complex mixtures. It has been used to analyze gasoline, jet fuel, diesel, bio-diesel and organic fraction of bio-crude/bio-oil. In these experiments, the first dimension of separation was non-polar, followed by a polar separation. Aqueous fractions of bio-crude and other aqueous samples have been examined with similar column combinations. However, sample preparation techniques such as derivatization, solvent extraction, and solid-phase extraction were necessary prior to analysis. In this study, aqueous fraction obtained from hydrothermal liquefaction of algae was characterized by two-dimensional gas chromatography coupled with time of flight mass spectrometry without prior sample preparation techniques using a polar separation in the first dimension followed by a non-polar separation. Two-dimensional plots from this analysis were compared with those obtained from the more traditional column combination. Results from qualitative as well as quantitative characterization of aqueous fractions of algal bio-crude are discussed in detail. The advantages of using a polar separation followed by a non-polar separation for characterization of organics in aqueous samples by two-dimensional gas chromatography coupled with time of flight mass spectrometry are highlighted.

Panisko, Ellen A.↗

Determination of Free Fatty Acids and Triglycerides by Gas Chromatography Using Selective Esterification Reactions

A method for selectively determining both free fatty acids (FFA) and triacylglycerides (TAGs) in biological oils was investigated and optimized using gas chromatography after esterification of the target species to their corresponding fatty acid methyl esters (FAMEs). The method used acid catalyzed esterification in methanolic solutions under conditions of varying severity to achieve complete conversion of more reactive FFAs while preserving the concentration of TAGs. Complete conversion of both free acids and glycerides to corresponding FAMEs was found to require more rigorous reaction conditions involving heating to 120°C for up to 2 h. Method validation was provided using gas chromatography–flame ionization detection, gas chromatography–mass spectrometry, and liquid chromatography–mass spectrometry. The method improves on existing methods because it allows the total esterified lipid to be broken down by FAMEs contributed by FFA compared to FAMEs from both FFA and TAGs. Single and mixed-component solutions of pure fatty acids and triglycerides, as well as a sesame oil sample to simulate a complex biological oil, were used to optimize the methodologies. Key parameters that were investigated included: HCl-to-oil ratio, temperature and reaction time. Pure free fatty acids were found to esterify under reasonably mild conditions (10 min at 50°C with a 2.1:1 HCl to fatty acid ratio) with 97.6 ± 2.3% recovery as FAMEs, while triglycerides were largely unaffected under these reaction conditions. The optimized protocol demonstrated that it is possible to use esterification reactions to selectively determine the free acid content, total lipid content, and hence, glyceride content in biological oils. This protocol also allows gas chromatography analysis of FAMEs as a more ideal analyte than glyceride species in their native state.

59 BASIC BIOLOGICAL SCIENCES↗

On the two-domain equations for gas chromatography.

We present an analysis of gas chromatographic columns where the stationary phase is not assumed to be a thin uniform coating along the walls of the cross section. We also give an asymptotic analysis assuming that the parameter {beta} = KD{sup II}{rho}{sup II}/D{sup I}{rho}{sup I} is small. Here K is the partition coefficient, and D{sup i} and {rho}{sup i}, i = I, II are the diffusivity and density in the mobile (i = I) and stationary (i = II) regions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rapid separation of beryllium and lanthanide derivatives by capillary gas chromatography

Previous studies describe derivatization of metal ions followed by analysis using gas chromatography, usually on packed columns. In many of these studies, stable and volatile derivatives were formed using fluorinated β-diketonate reagents. This paper extends previous work by investigating separations of the derivatives on small-diameter capillary gas chromatography columns and exploring on-fiber, solid-phase microextraction derivatization techniques for beryllium. The β-diketonate used for these studies was 1,1,1,2,2,6,6,7,7,7-decafluoro-3,5-heptanedione. Derivatization of lanthanides also required addition of a neutral donor, dibutyl sulfoxide, in addition to 1,1,1,2,2,6,6,7,7,7-decafluoro-3,5-heptanedione. Unoptimized separations on a 100-μm i.d. capillary column proved capable of rapid separations (within 15 min) of lanthanide derivatives that are adjacent to one another in the periodic table. Full-scan mass spectra were obtained from derivatives containing 5 ng of each lanthanide. Studies also developed a simple on-fiber solid-phase microextraction derivatization of beryllium. Beryllium could be analyzed in the presence of other alkali earth elements (Ba(II) and Sr(II)) without interference. Finally, extension of the general approach was demonstrated for several additional elements (i.e. Cu(II), Cr(III), and Ga(III)).

beryllium analysis↗

Extraction of O-isobutyl S-(2-diethylaminoethyl)methyl phosphothioate (Russian VX) and related chemical signatures from liquid eggs and analysis by Liquid Chromatography with Detection by Mass Spectrometry (LC-MS) and Gas Chromatography with Detection by Mass Spectrometry (GC-MS)

The following procedure describes the extraction of O-isobutyl S-(2- diethylaminoethyl)methyl phosphothioate (Russian VX) and related chemical signatures from liquid eggs and analysis by Liquid Chromatography with Detection by Mass Spectrometry (LC-MS) and Gas Chromatography with Detection by Mass Spectrometry (GC-MS) to determine the Russian VX chemical attribution signatures present in a contaminated liquid egg sample. These chemical attribution signatures may indicate the synthetic origin of the Russian VX sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extraction of O-isobutyl S-(2-diethylaminoethyl)methyl phosphothioate (Russian VX) and related chemical signatures from hot dogs and analysis by Liquid Chromatography with Detection by Mass Spectrometry (LC-MS) and Gas Chromatography with Detection by Mas

The following procedure describes the extraction of O-isobutyl S-(2- diethylaminoethyl)methyl phosphothioate (Russian VX) and related chemical signatures from hot dogs and analysis by Liquid Chromatography with Detection by Mass Spectrometry (LC-MS) and Gas Chromatography with Detection by Mass Spectrometry (GC-MS) to determine the Russian VX chemical attribution signatures present in a contaminated hot dog sample. These chemical attribution signatures may indicate the synthetic origin of the Russian VX sample.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comprehensive two-dimensional gas chromatography under low-pressure conditions

The analysis of thermally labile and high-boiling point compounds by gas chromatography (GC) can be a challenge. One technique to overcome these challenges is low-pressure GC, which uses the vacuum produced from the mass spectrometer and wide-bore columns to elute compounds at significantly lower temperatures. While GC-MS is a powerful technique, comprehensive two-dimensional gas chromatography (GC × GC), allows for resolution of compounds that would typically coelute using GC. Here, in this study, a pesticide standard mixture (8270 MegaMix Standard) was analyzed using a conventional GC × GC-TOFMS configuration (0.25 mm inner diameter (i.d.) to a 0.18 mm i.d. column) and low-pressure GC × GC-TOFMS configuration (0.53 mm i.d. to a 0.53 mm i.d. column). Elution temperatures, sensitivity, and peak capacity were investigated for both configurations. Compounds eluted an average of 30 °C less on the low-pressure GC × GC-TOFMS configuration compared to the conventional GC × GC-TOFMS configuration. Moreover, the compounds were separated in ~13 min on the low-pressure GC × GC-TOFMS as opposed to 33 min for conventional GC × GC-TOFMS. However, due to the wide-bore columns and faster runtimes the low-pressure GC × GC-TOFMS had a lower, β corrected 2D peak capacity, n c,β,2D , of 1260 while the conventional GC × GC-TOFMS was 3588. Interestingly, both configurations yielded a similar peak capacity production of 93 peaks/min and 107 peaks/min for low-pressure and conventional GC × GC-TOFMS, respectively. A “real world” sample of diesel fuel was tested on the low-pressure and conventional GC × GC-TOFMS configurations and similar results were obtained compared to the pesticide standard mix except the peak capacity production of the low-pressure GC × GC-TOFMS configuration was higher than that of the conventional GC × GC-TOFMS method.

47 OTHER INSTRUMENTATION↗