Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gas gain”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Measurement of the gas gain and understanding the gas flow in the Mu2e Tracker

The Mu2e experiment will search for the charged-lepton flavor violating (CLFV) neutrinoless conversion of a negative muon into an electron in the field of an Aluminum nucleus µ − N → e − N. The signature of this process is the emission of a monochromatic electron with an energy of 104.97 MeV. The Mu2e Tracker is a low mass straw tube detector, whose aim is to measure the position and the momentum of the electron. In past measurements, high values of currents were found in some panels of the Tracker in absence of any radioactive sources. In this report new measurements of currents, that were taken with the panel MN084 of the Mu2e Tracker are described. Moreover, the addition of a small amount of water vapour in the gas mixture and the influence of the environmental conditions on the currents of the panel are studied.

47 OTHER INSTRUMENTATION↗

Operation and performance of a dual-phase crystalline/vapor xenon time projection chamber

We have built and operated a crystalline/vapor xenon TPC, with the goal of improving searches for dark matter. The motivation for this instrument is the fact that beta decays from the radon decay chain to the ground state presently limit the state-of-the-art liquid/vapor xenon experiments. In contrast, a crystalline xenon target has the potential to exclude, or tag and reject radon-chain backgrounds. As a preamble to demonstrating such capabilities, the present article makes a first demonstration of the operation of a crystalline/vapor xenon TPC with electroluminescence (gas gain) for the electron signal readout. It also shows that the scintillation yield in crystalline xenon appears to be identical to that in liquid xenon, in contrast to previous results.

47 OTHER INSTRUMENTATION↗

High-rate heavy-ion tracking using MWPCs and PPACs with an Anti-Discharge Unit

This work reports on the development of two robust, heavy-ion beam tracking concepts operating at low pressure (< 15 Torr) for high rate applications (> 200 kHz). The first concept consists of a Multi-Wire Proportional Counter (MWPC) with a central anode consisting of 12 μm Au-plated Tungsten wires spaced 1 mm from each other. The anode grid is sandwiched between two segmented cathodes aligned orthogonally in the two dimensions for (x,y) particle localization. The second detector is a Parallel-Plate Avalanche Counter (PPAC) that uses the same readout geometry as the MWPC, but replaces the wire anode with a 150 nm silver layer deposited on both sides of a thin (< 1 mg/cm 2 ) polypropylene foil. Additionally, the bias circuitry for the PPAC anode central foil is equipped with an Anti-Discharge Unit (ADU) to prevent transitions from proportional operation to streamer formation, thereby avoiding damaging discharges. The localization capability of both detectors was tested with a low-rate alpha-particle source (241-Am). A position resolution of < 1 mm (FWHM) was achieved under stable, high-gas-gain (> 1000) operating conditions. Their performance in terms of detection efficiency as a function of the isotope charge (Z) was determined by irradiating the detectors with a cocktail beam (Z ≤ 15) with energy of ∼ 100 MeV/u. Full detection efficiency is maintained for all available fragments under optimal operational conditions (i.e., voltage bias). Full detection efficiency was achieved at rates above 200 kHz by irradiating the detectors with a 1 cm diameter 238 U beam at an energy of 143 MeV/u.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparative Study for Pressure Gain Combustion-Gas Turbine System Performance in NGCC Configurations

The Department of Energy (DOE) has a goal to increase natural gas combined cycle (NGCC) plant efficiency to greater than 70 percent on a lower heating value (LHV) basis. Improvement in gas turbine (GT) efficiency is key achieving this goal. While many of the traditional improvement methods (higher firing temperature, advanced materials, improved cooling methods, etc.) may increase current GT and NGCC efficiencies incrementally, combining these traditional advancements with breakthrough technologies such as pressure gain combustion (PGC) may provide significant system efficiency gains. PGC is a combustion process that results in a net pressure increase across the combustor (up to pressure ratio of 2.2) rather than the traditional (<5%) pressure drop. There are multiple PGC technologies being developed that create the pressure rise phenomena, including resonant pulse combustors (RPCs), pulse detonation engines (PDEs), wave rotor combustor (WRC) engines and rotating detonation engines (RDEs). In this study, scoping analyses of PGC concepts applied to NGCC power plants were performed by combining simplified analytical models for the RPC, PDE, WRC, and RDE types of pressure gain processes with a GT model to evaluate impacts of using each of the PGC technologies on key GT performance parameters. Sensitivity analyses were also performed. Ultimately, the PGC technologies were found to have the potential to increase simple cycle efficiency by 4–6 percent (absolute) and NGCC efficiency by 2–3 percent (absolute) based on the results of the current study.

03 NATURAL GAS↗

Innovative Natural Gas Technologies For Efficiency Gain In Reliable And Affordable Thermochemical Electricity Generation (INTEGRATE)

Hyper is a cutting-edge system that pairs computational models that simulate the response of different systems with physical components such as sensors and actuators to transfer said calculated response to the HyPer facility. Computational models must operate in real-time in order to resolve the system response when coupled to physical hardware. Real-time is defined by the minimal HyPer system response time of Δt = 0.080 s. The integration of these models serves as a foundation for performance characterization based on real-world SOFC hardware and paves the way for comprehensive fuel flexibility studies. This report underscores the innovative approach to cyber-physical system deployment at NETL’s HyPer Facility, highlighting the critical role of computational models in enhancing the performance and adaptability of energy technologies.

03 NATURAL GAS↗

Summary of GAIN BWR Off-Gas Study: Effect of Charcoal on Kr and Xe Delay

This is a summary of a more extensive report, written in collaboration with the GE-Hitachi BWR Owner's Group, detailing a study of BWR off-gas treatment. The study determined that aged charcoal continues to be effective for the delay of Kr and Xe through BWR off-gas treatment systems. It demonstrates the over-sized nature of existing charcoal beds, and highlights potential areas of improvement.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Topmetal CMOS direct charge sensing plane for neutrinoless double-beta decay search in high-pressure gaseous TPC

We propose a novel charge sensing concept for high-pressure Time Projection Chamber (TPC) to search for Neutrinoless Double-Beta Decay (NLDBD) with ton-scale isotope mass and beyond. A meter-sized plane, tiled with an array of CMOS integrated sensors called Topmetal that directly collect charge without gas avalanche gain, is to be deployed into a high-pressure gaseous TPC with working gases containing suitable NLDBD candidate isotopes such as Xe-136 and Se-82. The Topmetal sensor has an electronic noise <30 e- per pixel, which allows the detector to reach <1% FWHM energy resolution at the NLDBD Q-value for both Xe-136 and 82SeF6 gases by measuring ionization charges alone. The elimination of charge avalanche gain allows the direct sensing of slow-drifting ions, which enables the use of highly electronegative gas SeF6 in which free electrons do not exist. It supports the swapping of working gases without hardware modification, which is a unique way to validate signals against radioactive backgrounds. Since the sensor manufacturing and plane assembling could leverage unaltered industrial mass-production processes, stability, uniformity, scalability, and cost-effectiveness that are required for ton-scale experiments could all be reached. The strengths of TPC such as 3D ionization tracking and decay daughter tagging are retained. This development could lead to a competitive NLDBD experiment at and above ton-scale. The conceptual considerations, simulations, and initial prototyping are discussed.

Mei, Yuan↗

Measuring the evolution of intergalactic gas from z = 0 to 5 using the kinematic Sunyaev–Zel’dovich effect

ABSTRACT A complete census of baryons in the late Universe is a long-standing challenge due to the intermediate temperate and rarefied character of the majority of cosmic gas. To gain insight into this problem, we extract measurements of the kinematic Sunyaev–Zel’dovich (kSZ) effect from the cross-correlation of angular redshift fluctuations maps, which contain precise information about the cosmic density and velocity fields, and cosmic microwave background maps high-pass filtered using aperture photometry; we refer to this technique as angular redshift fluctuations (ARF)–kSZ tomography. Remarkably, we detect significant cross-correlation for a wide range of redshifts and filter apertures using 6dF galaxies, BOSS galaxies, and SDSS quasars as tracers, yielding a 11σ detection of the kSZ effect. We then leverage these measurements to set constraints on the location, density, and abundance of gas inducing the kSZ effect, finding that this gas resides outside dark matter haloes, presents densities ranging from 10 to 250 times the cosmic average, and comprises half of cosmic baryons. Taken together, these findings indicate that ARF–kSZ tomography provides a nearly complete census of intergalactic gas from z = 0 to 5.

Chaves-Montero, Jonás↗

Energy resolution and gain measurements in Argon-based gas mixtures: Exploring Ar:CF 4 for low energy measurements with TPCs

Time Projection Chambers (TPCs) are among the most advanced charged-particle detectors. Gas-filled TPCs have tracking capabilities that provide 3D-imaging of charged particles with a good energy resolution for spectroscopy. Different gas mixtures have different properties that determine the energy resolution as well as the spatial resolution. Therefore, optimization of operating conditions is required to simultaneously obtain adequate gain, energy resolution, spatial/track resolution, as well as higher drift velocities for high counting rates applications. Ar:CF 4 gas mixture has higher electron drift velocities and lower electron diffusion, which makes it an attractive candidate for TPC filling gas for low energy nuclear physics applications as compared to commonly used Ar:CH 4 and Ar:CO 2 gas mixtures, namely when tracking information is needed. However, other properties, including energy resolution and gain, remain largely unexplored in Ar:CF 4 especially at pressures and other operating conditions relevant for low-energy nuclear physics applications. Here, in this paper we report on gain and energy resolution measurements, using Gas Electron Multipliers (GEMs), in the less explored Ar:CF 4 mixture (Alfonsi et al., 2006), as well as in the more commonly used gas mixtures Ar:CH 4 and Ar:CO 2 . In addition to obtaining energy resolution and gain, we provide results from Garfield++ simulations for gain fluctuations, and their impact on energy resolution is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity and history match analysis of a carbon dioxide “huff-and-puff” injection test in a horizontal shale gas well in Tennessee

Due to improvements in well development, shale gas production has gained importance recently, especially in the United States. To improve gas production and develop a better understanding of shale reservoirs, researchers are conducting field tests to monitor CO 2 storage and enhanced gas recovery. Reservoir simulations can then utilize these field results for sensitivity studies, uncertainty analysis, history matching, gas production forecasts, and CO 2 storage capacity estimations. One such field test was performed for the Chattanooga Shale formation in Morgan County, Tennessee. Approximately 463 tonnes (510 tons) of CO 2 was successfully injected into a hydraulically fractured horizontal well over a thirteen-day period in March 2014. The injection test was achieved in four steps: pre-injection, injection, soaking, and flowback. In this paper, those steps were modeled with a reservoir simulator to match the historic production and injection rates with gas component compositions and forecast the production for five years. The reservoir fluid was modeled as a multi-component gas, including CH 4 , C 2 H 6 , C 3 H 8 , N 2 , and CO 2 . Langmuir constants, reservoir pressure, and fracture network volume were adjusted to match simulation results with observed production rates and gas composition. Results showed that, under the same reservoir conditions, each gas component behaves differently by way of compositional changes in production. CH4 behaves like N2, while CO 2 behaves like heavier hydrocarbons such as C 2 H 6 and C 3 H 8 . CO 2 plume results showed that, after injection, the produced CO 2 is mostly derived from fractured limestone (i.e., Fort Payne Formation) because the injected CO 2 is not adsorbed in limestone but rather by shale formations.

03 NATURAL GAS↗

Partially cracked ammonia mixture combustion in gas turbine combustors

Ammonia is gaining popularity for single fuel use in existing gas turbines, as it is carbonless, has higher hydrogen content per unit volume than liquid hydrogen, and facilitates easy storage and handling. However, the low flame speed of ammonia makes it prone to flame blow off and remains the chief concern for its use in power generation. Following previous studies that have shown improved combustion performance by partially cracking the fuel, in this computational study, efficacy of partially cracked ammonia as a replacement fuel for natural gas is evaluated. A high-pressure optically accessible combustor operated at ~10 bar pressure with non-vitiated heated air was used as the test platform. This combustor was equipped with a novel multifuel multi-tube micromixing injector (M3 injector). High resolution simulations of the flow fields both in the injector as well as the combustor were performed to understand the fuel mixing in the injector and in the inlet region of the combustor. These modeling results showed that the injector was highly effective for achieving mixture homogeneity at the entrance of the combustor for ammonia and natural gas injection, whereas, for hydrogen an earlier injection facilitating longer residence time would be beneficial. Also, these simulations show that while harnessing waste heat the ideal fuel dissociation fraction is between 0.4 and 0.55 for optimal operation.

Ammonia↗

Clump survival and migration in VDI galaxies: an analytical model versus simulations and observations

ABSTRACT We address the nature of the giant clumps in high-z galaxies that undergo violent disc instability, distinguishing between long-lived and short-lived clumps. We study the evolution of long-lived clumps during migration through the disc via an analytical model tested by simulations and confront theory with CANDELS-HST observations. The clump ‘bathtub’ model, which considers gas and stellar gain and loss, involves four parameters: the accretion efficiency α, the star formation rate (SFR) efficiency ϵd, and the outflow mass-loading factors for gas and stars, η and ηs. The corresponding time-scales are comparable to the migration time, two-three orbital times. The accretion-rate dependence on clump mass, gas, and stars, allows an analytical solution involving exponential growing and decaying modes. For the fiducial parameter values there is a main evolution phase where the SFR and gas mass are constant and the stellar mass is rising linearly with time. This makes the inverse specific SFR an observable proxy for clump age. When η or ϵd are high, or α is low, the decaying mode induces a decline of SFR and gas mass till the migration ends. Later, the masses and SFR approach an hypothetical exponential growth with a constant specific SFR. The model matches simulations with different, moderate feedbacks, both in isolated and cosmological settings. The observed clumps agree with our predictions, indicating that the massive clumps are long-lived and migrating. A challenge is to model feedback that is non-disruptive in massive clumps but suppresses SFR to match the galactic stellar-to-halo mass ratio.

Dekel, Avishai↗

Comparative Analysis of Heat Exchangers for High Temperature High Pressure Helium Component Testing

Helium gas loops have been designed and built to gain a better understanding of the gas thermohydraulic phenomena that take place in a helium system. Some of these loops are used for validation and testing of components for high temperature gas-cooled reactors (HTGRs). However, most of them operate at lower pressure and temperature than an HTGR. While these loops can provide valuable information about gas-cooled reactor components, the operating envelope of the experiment is constrained by the maximum operating conditions of the helium loop. In response to the lack of an experimental facility that can provide the infrastructure needed to validate and test components at nominal pressures and temperatures of HTGRS, the HElium Component Testing Out-of-pile Research (HECTOR) facility was designed at Idaho National Laboratory with the assistance of University of Idaho and Walsh Engineering. With the capability to test at temperatures up to 800°C and pressures of 8MPa, HECTOR serves as a critical tool for the advancement of HTGR technology. The facility's primary role is to provide a controlled, high-fidelity environment for the assessment of component resilience and efficiency under nominal HTGR conditions. In the quest to enhance the efficiency and performance of HECTOR, a comparative analysis of three distinct types of heat exchangers—shell and tube, offset strip fin, and printed-circuit—was conducted, focusing primarily on two critical metrics: the required surface area and pressure drop characteristics. The shell and tube heat exchanger, renowned for its robust design and widespread industrial application, was evaluated against the offset strip fin and the cuttingedge printed-circuit heat exchangers, both of which are lauded for their compactness and thermal effectiveness. This comparative study aims to provide detailed insights into the thermal management capabilities of each heat exchanger type under the conditions inherent to HECTOR, thereby facilitating an informed selection for systems demanding high operational integrity and efficiency.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Low Temperature Activation of Methane on Metal-Oxides and Complex Interfaces: Insights from Surface Science

The abundance of inexpensive, natural gas has transformed the energy landscape, whereby revealing new possibilities for sustainable chemical technologies or impacting those that have relied on traditional fossil fuels. The primary component, methane, is underutilized and wastefully exhausted, leading to anthropogenic global warming. Historically, the manipulation of methane remained “ clavis aurea ,” an insurmountable yet rewarding challenge and thus the focus of intense research. This is primarily due to an inability to dissociate C–H bonds in methane selectively, which requires a high energy penalty and is an essential prerequisite for the direct conversion of methane into a large set of value-added products. The discovery of such processes would promise an energy gainful use of natural gas benefiting several essential chemical processes associated with C1 chemistry. This first C–H bond dissociation step of the methane molecule appears in numerous catalytic mechanisms as the rate-determining step or most essential barrier sequence for all subsequent steps that follow in the production of C–C, C–O, or C x –H y –O z bonds found in value added products. A main goal is to catalytically reduce the energy barrier for the first C–H bond dissociation to be able to achieve the activation of methane at low or moderate temperatures. As such there is great value in understanding the fundamental nature of the active sites responsible for bond breaking or formation and thus be able to facilitate better control of this chemistry, leading to the development of new technologies for fuel production and chemical conversion. Surface science studies offer enhanced perspectives for a careful manipulation of bonds over the last layer atoms of catalyst surfaces, an essential factor for the design of atomically precise catalysts and unravelling of the reaction mechanism. With the advent of new surface imaging, spectroscopy, and in situ tools, it has been possible to decipher the surface chemistry of complex materials systems and further our understanding of atomic active sites on the surfaces of metals, oxides, and carbides or metal–oxide and metal–carbide interfaces. The once considered near impossible step of C–H bond activation is now observed at low temperatures with high propensity over a collection of oxide, metal–oxide, and metal–carbide systems in a conventional or inverse configuration (oxide or carbide on metal). The enabling of C–H activation at low temperature has opened interesting possibilities for the specific production of chemicals such as methanol directly from methane, a step toward facile synthesis of liquid fuels. We highlight the most recent of these results and present the key aspects of active site configurations engineered from surface science studies which enable such a simple reactive event through careful manipulation of the last surface layer of atoms found in the catalyst structure. New concepts which help in the activation and conversion of methane are discussed.

36 MATERIALS SCIENCE↗