Economic gas chromatograph system for subambient pressure gas sampling

Gas chromatograph sampling system consists of a manifold with a gas-sample valve, a minimum-volume pressure transducer with a portable monitor, a vacuum-source valve, and a sample inlet valve. Increased accuracy of analysis is obtained by better control of sample size.

Mitchell, S. M.↗

The N.A.C.A. Combustion Chamber Gas-sampling Valve and Some Preliminary Test Results

A gas sampling valve of the inertia-operated type was designed for procuring samples of the gases in the combustion chamber of internal combustion engines at identical points in successive cycles so that the analysis of the gas samples thus procured may aid in the study of the process of combustion. The operation of the valve is described. The valve was used to investigate the CO2 content of gases taken from the quiescent combustion chamber of a high speed compression-ignition engine when operating with two different multiple-orifice fuel injection nozzles. An analysis of the gas samples thus obtained shows that the state of quiescence in the combustion chamber is maintained during the combustion of the fuel.

Spanogle, J A↗

Direct Simulation Monte Carlo Studies of the Gas Sampling for the VATMOS-SR Mission Concept

VATMOS-SR (Venus ATMOSpheric - Sample Return) is a small spacecraft mission concept which would return a gas sample from the upper atmosphere of Venus to Earth for scientific analysis. This could be the first sample return mission for an extra-terrestrial atmosphere, and potentially the first sample return from an Earth-sized planet. The VATMOS-SR mission concept consists of a SmallSat atmospheric sampling probe (45 deg. sphere/cone geometry, <1 m diameter) that is designed to skim through the Venus upper atmosphere and acquire gas samples below the homopause altitude (around ~110 km altitude), where the different atmospheric gases are mixed. The velocity of the spacecraft where sampling would occur is expected to be between ~10.5 km/s and ~13.1 km/s, depending on the trajectory chosen. This presentation will discuss hypervelocity sampling in the upper atmosphere of Venus, with respect to the VATMOS-SR mission concept. VATMOS-SR would enable critical atmospheric measurements to form a full picture of how, why, and when Venus evolved to be so different from Earth and Mars. The abundances and isotopic compositions of volatile elements (such as N, C, S, O and the noble gases) in planetary atmospheres record volatile delivery during accretion, outgassing from planetary interiors, and atmospheric loss to space. Precise and accurate determinations of atmospheric volatile signatures are the key to understanding the origins and geodynamical evolution of Venus compared to the other terrestrial planets. Hypersonic sampling poses unique technical and scientific challenges. To ensure it is possible to relate the composition of the sampled gases to the free stream atmospheric composition, large-scale numerical simulations are employed to model the flow through the VATMOS-SR sampling system. In particular, an emphasis is placed on quantifying noble gas isotopic fractionation that occurs during the sample acquisition and transfer process in order to determine how measured isotopic ratios of noble gases in the sample compare to actual isotopic ratios in the Venusian atmosphere. The Direct Simulation Monte Carlo (DSMC) code SPARTA, an open source software package developed by Sandia National Laboratories, is used in this work. SPARTA, based on Bird’s DSMC method, is a molecular-level gas-kinetic technique. As SPARTA is able to model hypervelocity reacting flows in strong chemical and thermal non-equilibrium, this software package is well suited to determine relevant flow properties for the VATMOS-SR mission concept, and to numerically quantify the expected level of elemental and/or isotopic fractionation in the sample acquired by VATMOS-SR. This presentation will show results from 3D simulations correlating the noble gas isotopic fractionation in the gas acquired at hypervelocity speeds to its ambient atmosphere value. In particular, emphasis will be placed at Xenon isotopes of masses 128 and 130, as precise measurements of that ratio would yield a comparison to Earth’s atmosphere. Additionally, sensitivity studies that quantify the uncertainties due to the freestream parameters as well as the modeling parameters will be performed.

direct simulation Monte Carlo↗

The VATMOS-SR Mission Concept: DSMC Studies of the Gas Sampling

VATMOS-SR (Venus ATMOSpheric - Sample Return) is a small spacecraft mission concept that would return a gas sample from the upper atmosphere of Venus to Earth for scientific analysis. This could be the first sample return mission for an extra-terrestrial atmosphere and potentially the first sample return from an Earth-sized planet. The VATMOS-SR mission concept consists of a SmallSat atmospheric sampling probe (45 deg. sphere/cone geometry, <1 m diameter) that is designed to skim through the Venus upper atmosphere and acquire gas samples below the homopause altitude (around ~110 km altitude), where the different atmospheric gases are mixed. The velocity of the spacecraft where sampling would occur is expected to be between ~10.5 km/s and ~13.1 km/s, depending on the trajectory chosen. This presentation will discuss hypervelocity sampling in the upper atmosphere of Venus with respect to the VATMOS-SR mission concept. VATMOS-SR would enable critical atmospheric measurements to form a complete picture of how, why, and when Venus evolved to be so different from Earth and Mars. The abundances and isotopic compositions of volatile elements (such as N, C, S, O, and the noble gases) in planetary atmospheres record volatile delivery during accretion, outgassing from planetary interiors, and atmospheric loss to space. Precise and accurate determinations of volatile atmospheric signatures are the key to understanding the origins and geodynamical evolution of Venus compared to the other terrestrial planets. Hypersonic sampling poses unique technical and scientific challenges. To ensure it is possible to relate the composition of the sampled gases to the free stream atmospheric composition, large-scale numerical simulations are employed to model the flow through the VATMOS-SR sampling system. In particular, an emphasis is placed on quantifying noble gas isotopic fractionation that occurs during the sample acquisition and transfer process to determine how measured isotopic ratios of noble gases in the sample compared to actual isotopic ratios in the Venusian atmosphere. The Direct Simulation Monte Carlo (DSMC) code SPARTA, an open-source software package developed by Sandia National Laboratories, is used in this work. SPARTA, based on Bird’s DSMC method, is a molecular-level gas-kinetic technique. As SPARTA is able to model hypervelocity reacting flows in strong chemical and thermal non-equilibrium, this software package is well suited to determine relevant flow properties for the VATMOS-SR mission concept and to numerically quantify the expected level of elemental and/or isotopic fractionation in the sample acquired by VATMOS-SR. This presentation will show results from 3D simulations correlating the noble gas isotopic fractionation in the gas acquired at hypervelocity speeds to its ambient atmosphere value. In particular, emphasis will be placed on Xenon isotopes of masses 128 and 130, as precise measurements of that ratio would yield comparison to Earth’s atmosphere. Additionally, sensitivity studies that quantify the uncertainties due to the freestream parameters, as well as the modeling parameters, will be performed.

direct simulation Monte Carlo↗

Gas sampling method for determining pollutant concentrations in the flame zone of two swirl-can combustor modules

A gas sampling probe and traversing mechanism were developed to obtain detailed measurements of gaseous pollutant concentrations in the primary and mixing regions of combustors in order to better understand how pollutants are formed. The gas sampling probe was actuated by a three-degree-of-freedom traversing mechanism and the samples obtained were analyzed by an on-line gas analysis system. The pollutants in the flame zone of two different swirl-can combustor modules were measured at an inlet-air temperature of 590 K, pressure of 6 atmospheres, and reference velocities of 23 and 30 meters per second at a fuel-air ratio of 0.02. Typical results show large spatial gradients in the gaseous pollutant concentration close to the swirl-can module. Average concentrations of unburned hydrocarbons and carbon monoxide decrease rapidly in the downstream wake regions of each module. By careful and detailed probing, the effect of various module design features on pollutant formation can be assessed. The techniques presently developed seem adequate to obtain the desired information.

Duerr, R. A.↗

Moisture content and gas sampling device

An apparatus is described for measuring minute quantities of moisture and other contaminants within sealed enclosures such as electronic assemblies which may be subject to large external atmospheric pressure variations. An array of vacuum quality valves is arranged to permit cleansing of the test apparatus of residual atmospheric components from a vacuum source. This purging operation evacuates a gas sample bottle, which is then connected by valve settings to provide the drive for withdrawing a gas sample from the sealed enclosure under test into the sample bottle through a colometric detector tube (Drager tube) which indicates moisture content. The sample bottle may be disconnected and its contents (drawn from the test enclosure) separately subjected to mass spectrograph analysis.

Krieg, H. C., Jr.↗

Evaluation of a wedge gas-sampling probe

The performances of a wedge-type gas-sampling probe and pitot probes are compared in applications to flowfield profile studies. The flow structure data obtained by these techniques are found to agree well in flow regions with and without significant gradients. The wedge-type probe showed a good service life and allowed a substantial reduction of the sampling time. The wedge probe design is discussed.

Beach, H. L., Jr.↗

Description of the Gas Sampling and Circulation System for the LYNM PE1-A Experiment

A series of multiphysics experiments, referred to as Physics Experiment 1 (PE1) is underway at the U.S. Nevada National Security Site. The PE1 series includes detonations of three underground chemical explosions. As the name implies, there are a number of experiments investigating the signals generated by the explosion. The experiment series objectives are outlined in a report from Lawrence Livermore National Laboratory.1 One of the experiments is a gas migration experiment. Gas tracers were imbedded in the explosives and gas sampling boreholes were installed in the formation in the test bed. Connected to the monitoring points is a circulation system that moves gas to a central measurement location. This report does not describe the gas analysis or collection systems, but rather the circulation system that provides the gas for measurement. Here, we have combined four project documents into a single report that describes the design, build, installation, testing, and operation of the gas sampling network.

42 ENGINEERING↗

Analysis of flow dynamics through small diameter gas sampling systems

The removal of gas material through a capillary opening in a surface is analyzed. The gas, from which the sample is removed, is moving past the surface at supersonic velocities. A variety of possible conditions of temperature, pressure and composition are discussed in an effort to emulate conditions that might be found at the surface of a vehicle traversing the altitude range 100-50 km, or might exist at the surface of a model in the stream of a high enthalpy wind tunnel. Aspects discussed include: (1) the throughput of the capillary for conditions of different lengths and different L/a (length/radius) ratios; (2) the total throughput when the surface in question contains many hundreds of these capillaries; (3) the effect of the capillaries upon the composition of the analyzed gas; (4) the effect of the capillary or capillaries upon the gas stream itself; and (5) the implications of the calculations upon the possible implementation of this type of device as an inlet for a mass spectrometer to be developed for analyzing the upper atmosphere.

Brown, K. G.↗

Workflow for Process Automation of Soil Gas Results from an Automated Soil Gas-Sampling System for Application in Carbon Storage Projects

Conference presentation at Geoconvention, Calgary, Alberta, Canada, May 12–14, 2025. The Energy & Environmental Research Center (EERC) developed an automated workflow for processing soil gas measurements collected from the automated soil gas-sampling systems deployed across the project site. Raw soil gas measurements are collected from each station every 4 hours and automatically uploaded to a cloud database. The workflow begins by writing code to download the data to a workstation automatically, then the data are published to an online dashboard that visualizes the measurements in time-series plots and a process-based decision-making framework. This automated workflow accelerates the time from data acquisition to decision-making. It supports carbon storage project operators by preparing and delivering a live, standardized dataset for quick analysis and source attribution to provide assurance of containment and overall permit compliance.

02 PETROLEUM↗

Workflow for Process Automation of Soil Gas Results from an Automated Soil Gas-Sampling System for Application in Carbon Storage Projects

Extended abstract for Geoconvention, Calgary, Alberta, Canada, May 12–14, 2025. The Energy & Environmental Research Center (EERC) developed an automated workflow for processing soil gas measurements collected from the automated soil gas-sampling systems deployed across the project site. Raw soil gas measurements are collected from each station every 4 hours and automatically uploaded to a cloud database. The workflow begins by writing code to download the data to a workstation automatically, then the data are published to an online dashboard that visualizes the measurements in time-series plots and a process-based decision-making framework. This automated workflow accelerates the time from data acquisition to decision-making. It supports carbon storage project operators by preparing and delivering a live, standardized dataset for quick analysis and source attribution to provide assurance of containment and overall permit compliance.

02 PETROLEUM↗

Test evaluation of potential heatshield contamination of an outer planet probe's gas sampling system

The feasibility of retaining the heat shield for outer planet probes was investigated as a potential source of atmospheric sample contamination by outgassing. The onboard instruments which are affected by the concept are the pressure sensor, temperature sensor, IR detector, nephelometer, and gas sampling instruments. It was found that: (1) The retention of the charred heatshield and the baseline atmospheric sampling concepts are compatible with obtaining noncontaminated atmospheric samples. (2) Increasing the sampling tube length so that it extends beyond the viscous boundary layer eliminates contamination of the atmospheric sample. (3) The potential for contamination increases with angle of attack.

Kessler, W. C.↗

SUBSLAB SOIL GAS SAMPLING PLAN FOR COMMUNICATION, MAINTENANCE, AND STORAGE, SOLID WASTE MANAGEMENT UNIT (SWMU) 082

HydroGeoLogic, Inc. (HGL) prepared this Subslab Soil Gas (SSSG) Sampling Plan for Communications, Maintenance, and Storage (CM&S), Solid Waste Management Unit (SWMU) 082 for the National Aeronautics and Space Administration (NASA), Kennedy Space Center (KSC), Florida, under Contract Number 80KSC019D0012, Task Order 80KSC021F0097 technical directive #1, awarded on September 26, 2022. As described herein, all SSSG sampling and evaluations will be completed in accordance with U.S. Environmental Protection Agency’s (EPA), OSWER Technical Guide for Assessing and Mitigating the Vapor Intrusion Pathway from Subsurface Vapor Sources to Indoor Air (EPA, 2015).

Jason J Bublitz↗