Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gas systems and purification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Regenerable Air Purification System for Gas-Phase Contaminant Control

A regenerable air purification system (RAPS) that uses water vapor to displace adsorbed contaminants from an. adsorbent column into a closed oxidation loop is under development through cooperative R&D between Vanderbilt University and NASA Ames Research Center. A unit based on this design can be used for removing trace gas-phase contaminants from spacecraft cabin air or from polluted process streams including incinerator exhaust. Recent work has focused on fabrication and operation of a RAPS breadboard at NASA Ames, and on measurement of adsorption isotherm data for several important organic compounds at Vanderbilt. These activities support the use and validation of RAPS modeling software also under development at Vanderbilt, which will in turn be used to construct a prototype system later in the project.

Constantinescu, Ileana C.↗

Impregnation of Catalytic Metals in Single-Walled Carbon Nanotubes for Toxic Gas Conversion in Life Support System

Carbon nanotubes (CNTs) possess extraordinary properties such as high surface area, ordered chemical structure that allows functionalization, larger pore volume, and very narrow pore size distribution that have attracted considerable research attention from around the world since their discovery in 1991. The development and characterization of an original and innovative approach for the control and elimination of gaseous toxins using single walled carbon nanotubes (SWNTs) promise superior performance over conventional approaches due to the ability to direct the selective uptake of gaseous species based on their controlled pore size, increased adsorptive capacity due to their increased surface area and the effectiveness of carbon nanotubes as catalyst supports for gaseous conversion. We present our recent investigation of using SWNTs as catalytic supporting materials to impregnate metals, such as rhodium (Rh), palladium (Pd) and other catalysts. A protocol has been developed to oxidize the SWNTs first and then impregnate the Rh in aqueous rhodium chloride solution, according to unique surface properties of SWNTs. The Rh has been successfully impregnated in SWNTs. The Rh-SWNTs have been characterized by various techniques, such as TGA, XPS, TEM, and FTIR. The project is funded by a NASA Research Announcement Grant to find applications of single walled nanocarbons in eliminating toxic gas Contaminant in life support system. This knowledge will be utilized in the development of a prototype SWNT KO, gas purification system that would represent a significant step in the development of high efficiency systems capable of selectively removing specific gaseous for use in regenerative life support system for human exploration missions.

Li, Jing↗

Regenerable Air Purification System for Gas-Phase Contaminant Control

Tests of a pre-prototype regenerable air purification system (RAPS) that uses water vapor to displace adsorbed contaminants from an adsorbent column have been performed at NASA Ames Research Center. A unit based on this design can be used for removing trace gas-phase contaminants from spacecraft cabin air or from polluted process streams including incinerator exhaust. During the normal operation mode, contaminants are removed from the air on the column. Regeneration of the column is performed on-line. During regeneration, contaminants are displaced and destroyed inside the closed oxidation loop. In this presentation we discuss initial experimental results for the performance of RAPS in the removal and treatment of several important spacecraft contaminant species from air.

Constantinescu, Ileana C.↗

Biosphere 2 test module experimentation program

The Biosphere 2 Test Module is a facility which has the capability to do either short or long term closures: five month closures with plants were conducted. Also conducted were investigations of specific problems, such as trace gas purification by bioregenerative systems by in-putting a fixed concentration of a gas and observing its uptake over time. In other Test Module experiments, the concentration of one gas was changed to observe what effects this has on other gases present or on the system. The science of biospherics which encompasses the study of closed biological systems provides an opening into the future in space as well as in the Earth's biosphere.

Alling, Abigail↗

Technology Assessment for Producing Propellant From Lunar Water

Introduction: The presence of water ice in permanently shadowed regions (PSRs) on the lunar surface may enable a sustained human presence on the Moon with minimal need for consumables. One of the most valuable uses of lunar water is to produce rocket propellant. A sustained human presence on the Moon will re-quire frequent launches from the lunar surface, and each launch will require tons of propellant. However, many other volatiles are likely to be present in the areas where lunar water is stable1. Producing propellant from lunar water in-situ will require the separation and purification of water before it can be electrolyzed into oxygen and hydrogen gas. The Resource Exploration and Science of OUR Cosmic Environment (RESOURCE) project, funded by the Solar System Exploration Research Virtual Institute (SSERVI) program, includes a task to demonstrate the end-to-end process of water extraction, capture, purification and electrolysis to produce pure/dry oxygen gas sourced from an icy regolith mixture. Water Purification: The requirements for water purity are driven by the type of water electrolyzer used. For example, the water electrolyzer currently used on the International Space Station is based on proton ex-change membrane (PEM) technology. PEM-based electrolyzers require water to be ultrapure and deionized (>10 MegaOhm-cm) so that electrical conductivity is limited to the membranes themselves, where electrical current is used to convert H2O into H2 and O2.. A practical first step toward purifying water that is sourced from a lunar PSR is to use freeze distillation to separate water from other volatiles2. A sub-micronic filter can also be used to ensure that a minimal amount of dust is present in any lunar water that is captured. The combination of freeze distillation and sub-micronic filtration will result in relatively pure water but would require a deionization step if being fed into a PEM electrolyzer. Water Electrolysis: An alternative to PEM electrolysis is to use a Solid Oxide Electrolyzer (SOE). This technology operates at a much higher operating temperature (~800oC) and has a limited pressure range but does not require water to be ultrapure and deionized. Another advantage of SOE technology is that it produces pure dry oxygen gas without the need of an additional drying step. PEM electrolyzers produce humid oxygen gas and the humidity must be removed prior to liquefaction. Assessment: In order to compare PEM and SOE technologies side-by-side, they must be compared at a system level that includes water purification and gas drying steps. Engineers at the Johnson Space Center up-dated and utilized a detailed In-Situ Resource Utilization (ISRU) system model to compare and select the best option for the RESOURCE project which will conclude with a laboratory demonstration of the process of producing pure/dry oxygen from an icy regolith mixture in 2025.

A.J. Paz↗

Technology Assessment for Producing Propellant From Lunar Water

Introduction: The presence of water ice in permanently shadowed regions (PSRs) on the lunar surface may enable a sustained human presence on the Moon with minimal need for consumables. One of the most valuable uses of lunar water is to produce rocket propellant. A sustained human presence on the Moon will re-quire frequent launches from the lunar surface, and each launch will require tons of propellant. However, many other volatiles are likely to be present in the areas where lunar water is stable1. Producing propellant from lunar water in-situ will require the separation and purification of water before it can be electrolyzed into oxygen and hydrogen gas. The Resource Exploration and Science of OUR Cosmic Environment (RESOURCE) project, funded by the Solar System Exploration Research Virtual Institute (SSERVI) program, includes a task to demonstrate the end-to-end process of water extraction, capture, purification and electrolysis to produce pure/dry oxygen gas sourced from an icy regolith mixture. Water Purification: The requirements for water purity are driven by the type of water electrolyzer used. For example, the water electrolyzer currently used on the International Space Station is based on proton ex-change membrane (PEM) technology. PEM-based electrolyzers require water to be ultrapure and deionized (>10 MegaOhm-cm) so that electrical conductivity is limited to the membranes themselves, where electrical current is used to convert H2O into H2 and O2.. A practical first step toward purifying water that is sourced from a lunar PSR is to use freeze distillation to separate water from other volatiles2. A sub-micronic filter can also be used to ensure that a minimal amount of dust is present in any lunar water that is captured. The combination of freeze distillation and sub-micronic filtration will result in relatively pure water but would require a deionization step if being fed into a PEM electrolyzer. Water Electrolysis: An alternative to PEM electrolysis is to use a Solid Oxide Electrolyzer (SOE). This technology operates at a much higher operating temperature (~800oC) and has a limited pressure range but does not require water to be ultrapure and deionized. Another advantage of SOE technology is that it produces pure dry oxygen gas without the need of an additional drying step. PEM electrolyzers produce humid oxygen gas and the humidity must be removed prior to liquefaction. Assessment: In order to compare PEM and SOE technologies side-by-side, they must be compared at a system level that includes water purification and gas drying steps. Engineers at the Johnson Space Center up-dated and utilized a detailed In-Situ Resource Utilization (ISRU) system model to compare and select the best option for the RESOURCE project which will conclude with a laboratory demonstration of the process of producing pure/dry oxygen from an icy regolith mixture in 2025.

ISRU↗

Integrated System Design for Air Revitalization in Next Generation Crewed Spacecraft

The capabilities of NASA's existing environmental control and life support (ECLS) system designs are inadequate for future human space initiatives that involve long-duration space voyages and interplanetary missions. This paper discusses the concept of an integrated system of CO2 removal and trace contaminant control units that utilizes novel gas separation and purification techniques and optimized thermal and mechanical design, for future spacecraft. The integration process will enhance the overall life and economics of the existing systems by eliminating multiple mechanical devices with moving parts.

Mulloth, Lila↗

Module for Oxygenating Water without Generating Bubbles

A module that dissolves oxygen in water at concentrations approaching saturation, without generating bubbles of oxygen gas, has been developed as a prototype of improved oxygenators for water-disinfection and water-purification systems that utilize photocatalyzed redox reactions. Depending on the specific nature of a water-treatment system, it is desirable to prevent the formation of bubbles for one or more reasons: (1) Bubbles can remove some organic contaminants from the liquid phase to the gas phase, thereby introducing a gas-treatment problem that complicates the overall water-treatment problem; and/or (2) in some systems (e.g., those that must function in microgravity or in any orientation in normal Earth gravity), bubbles can interfere with the flow of the liquid phase. The present oxygenation module (see Figure 1) is a modified version of a commercial module that contains >100 hollow polypropylene fibers with a nominal pore size of 0.05 m and a total surface area of 0.5 m2. The module was originally designed for oxygenation in a bioreactor, with no water flowing around or inside the tubes. The modification, made to enable the use of the module to oxygenate flowing water, consisted mainly in the encapsulation of the fibers in a tube of Tygon polyvinyl chloride (PVC) with an inside diameter of 1 in. (approx.=25 mm). In operation, water is pumped along the insides of the hollow fibers and oxygen gas is supplied to the space outside the hollow tubes inside the PVC tube. In tests, the pressure drops of water and oxygen in the module were found to be close to zero at water-flow rates ranging up to 320 mL/min and oxygen-flow rates up to 27 mL/min. Under all test conditions, no bubbles were observed at the water outlet. In some tests, flow rates were chosen to obtain dissolved-oxygen concentrations between 25 and 31 parts per million (ppm) . approaching the saturation level of approx.=35 ppm at a temperature of 20 C and pressure of 1 atm (approx.=0.1 MPa). As one would expect, it was observed that the time needed to bring a flow of water from an initial low dissolved-oxygen concentration (e.g., 5 ppm) to a steady high dissolved-oxygen concentration at or near the saturation level depends on the rates of flow of both oxygen and water, among other things. Figure 2 shows the results of an experiment in which a greater flow of oxygen was used during the first few tens of minutes to bring the concentration up to approx.=25 ppm, then a lesser flow was used to maintain the concentration.

Gonzalez-Martin, Anuncia↗

Proportional counter for X-ray analysis of lunar and planetary surfaces

A position sensitive proportional scintillation detector was developed and evaluated for use in applications involving X-ray imaging as well as spectroscopy. Topics covered include limitations of the proportional scintillation counter for use in space; purification of the xenon gas in the detector, and the operation of the detector system. Results show that the light signal in a proportional scintillation detector remains well localized. With modest electric fields in xenon, the primary electrons from a photoelectric absorption of an X-ray can be brought a distance of a few millimeters to a higher field region without spreading more than a millimeter or so. Therefore, it is possible to make a proportional scintillation detector with good position sensitivity that could be used to calibrate out the difference in light collection over its sensitive volume.

Source record↗

Reactor Simulator Testing Overview

Test Objectives Summary: a) Verify operation of the core simulator, the instrumentation & control system, and the ground support gas and vacuum test equipment. b) Examine cooling & heat regeneration performance of the cold trap purification. c) Test the ALIP pump at voltages beyond 120V to see if the targeted mass flow rate of 1.75 kg/s can be obtained in the RxSim. Testing Highlights: a) Gas and vacuum ground support test equipment performed effectively for operations (NaK fill, loop pressurization, and NaK drain). b) Instrumentation & Control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings and ramped within prescribed constraints. It effectively interacted with reactor simulator control model and defaulted back to temperature control mode if the transient fluctuations didn't dampen. c) Cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained which was lower than the predicted 750 K but 156 K higher than the minimum temperature indicating the design provided some heat regeneration. d) ALIP produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz.

Schoenfeld, Michael P.↗

Reactor Simulator Testing Overview

OBJECTIVE: Integrated testing of the TDU components TESTING SUMMARY: a) Verify the operation of the core simulator, the instrumentation and control system, and the ground support gas and vacuum test equipment. b) Thermal test heat regeneration design aspect of a cold trap purification filter. c) Pump performance test at pump voltages up to 150 V (targeted mass flow rate of 1.75 kg/s was not obtained in the RxSim at the originally constrained voltage of 120 V). TESTING HIGHLIGHTS: a) Gas and vacuum ground support test equipment performed effectively for NaK fill, loop pressurization, and NaK drain operations. b) Instrumentation and control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings. c) Cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained which was lower than the predicted 750 K but 156 K higher than the cold temperature indicating the design provided some heat regeneration. d) ALIP produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz.

Schoenfeld, Michael P.↗

Carbon-isotopic analysis of dissolved acetate

Heating of dried, acetate-containing solids together with oxalic acid dihydrate conveniently releases acetic acid for purification by gas chromatography. For determination of the carbon-isotopic composition of total acetate, the acetate-containing zone of the chromatographic effluent can be routed directly to a combustion furnace coupled to a vacuum system allowing recovery, purification, and packaging of CO2 for mass-spectrometric analysis. For analysis of methyl carbon, acetic acid can be cryogenically trapped from the chromatographic effluent, then transferred to a tube containing excess NaOH. The tube is evacuated, sealed, and heated to 500 degrees C to produce methane by pyrolysis of sodium acetate. Subsequent combustion of the methane allows determination of the 13C content at the methyl position in the parent acetate. With typical blanks, the standard deviation of single analyses is less than 0.4% for acetate samples larger than 5 micromoles. A full treatment of uncertainties is outlined.

Non-NASA Center↗

Simultaneous stack gas scrubbing wastewater purification

Variations of a process for removing sulfur dioxide from stack gases and using it to treat municipal waste water are described. The once-through system lowers the pH of the scrubbing water from minor depressions to a pH of about 2.5 under certain conditions. A recycle system uses iron for catalytic oxidation of sulfurous acid to sulfuric acid allowing very large amounts of sulfur dioxide to be absorbed in a small portion of water. The partial recycle system uses municipal wastewater and iron as a scrubbing medium, followed by neutralization of the wastewater with lime to produce an iron hydroxide precipitation which, when removed, produces tertiary quality treated wastewater. The SO2 scrubber is described, test results are analyzed, and a preliminary capital cost estimate for the three processes is included.

Source record↗

Reactor Simulator Testing

As part of the Nuclear Systems Office Fission Surface Power Technology Demonstration Unit (TDU) project, a reactor simulator test loop (RxSim) was design & built to perform integrated testing of the TDU components. In particular, the objectives of RxSim testing was to verify the operation of the core simulator, the instrumentation and control system, and the ground support gas and vacuum test equipment. In addition, it was decided to include a thermal test of a cold trap purification design and a pump performance test at pump voltages up to 150 V since the targeted mass flow rate of 1.75 kg/s was not obtained in the RxSim at the originally constrained voltage of 120 V. This paper summarizes RxSim testing. The gas and vacuum ground support test equipment performed effectively in NaK fill, loop pressurization, and NaK drain operations. The instrumentation and control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings. The cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained which was lower than the predicted 750 K but 156 K higher than the cold temperature indicating the design provided some heat regeneration. The annular linear induction pump (ALIP) tested was able to produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz. Keywords: fission, space power, nuclear, liquid metal, NaK.

Schoenfeld, Michael P.↗