Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gaseous detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging

The PICOSEC-Micromegas (PICOSEC-MM) detector is a novel gaseous detector designed for precise timing resolution in experimental measurements. It eliminates time jitter from charged particles in ionization gaps by using extreme UV Cherenkov light emitted in a crystal, detected by a Micromegas photodetector with an appropriate photocathode. The first single-channel prototype tested in 150 GeV/c muon beams achieved a timing resolution below 25 ps, a significant improvement compared to standard Micropattern Gaseous Detectors (MPGDs). This work explores the specifications for applying these detectors in monitored neutrino beams for the ENUBET Project. Key aspects include exploring resistive technologies, resilient photocathodes, and scalable electronics. New 7-pad resistive detectors are designed to handle the particle flux. In this paper, two potential scenarios are briefly considered: tagging electromagnetic showers with a timing resolution below 30ps in an electromagnetic calorimeter as well as individual particles (mainly muons) with about 20ps respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of thin-gap GEM- μ RWELL hybrid detectors

Micro Pattern Gaseous Detectors (MPGDs) are used for tracking in High Energy Physics and Nuclear Physics because of their large area, excellent spatial resolution capabilities and low cost. However, for high energy charged particles impacting at a large angle with respect to the axis perpendicular to detector plane, the spatial resolution degrades significantly because of the long trail of ionization charges produced in clusters all along the track in the drift region of the detector. The long ionization charge trail results in registering hits from large number of strips in the readout plane which makes it challenging to precisely reconstruct the particle’s position using simple center of gravity algorithm. As a result, the larger the drift gap, the more severe the deterioration of spatial resolution for inclined tracks. For the same reason, the position resolution is also severely degraded in a large magnetic field, where the Lorentz E x B effect causes the ionization charges to follow a curved and longer path in the detector gas volume. In this paper, we report on the development of thin-gap MPGDs as a way to maintain excellent spatial resolution capabilities of MPGD detectors over a wide angular range of incoming particles. In a thin-gap MPGD, the thickness of the gas volume in the drift region is reduced from typically 3 mm to 1 mm or less. We present preliminary test beam results demonstrating the improvement in spatial resolution from 400 m with a standard 3 mm gap μ RWELL prototype to ~140 μ m with a double amplification GEM- μ RWELL thin-gap hybrid detector. Here, we also discuss the impact of a thin-gap drift volume on other aspects of the performance of MPGD technologies such as the efficiency and detector stability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a precise-timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and a Micromegas amplifying structure, targeting a time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a time resolution below σ = 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B 4 C), is pursued. Results from prototypes equipped with DLC and B 4 C photocathodes exhibited a time resolution of σ ≈ 32 ps and σ ≈ 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time projection chamber for GADGET II

The established Gaseous Detector with Germanium Tagging (GADGET) detection system is used to measure weak, low-energy 𝛽-delayed proton decays. It consists of the Gaseous Proton Detector equipped with a MICROMEGAS (MM) readout to detect protons and other charged particles calorimetrically, surrounded by the Segmented Germanium Array (SeGA) for high-resolution detection of prompt 𝛾 rays. To upgrade GADGET's Proton Detector to operate as a compact time projection chamber (TPC) for the detection, three-dimensional imaging and identification of low-energy 𝛽-delayed single- and multiparticle emissions mainly of interest to astrophysical studies. A new high granularity MM board with 1024 pads has been designed, fabricated, installed, and tested. A high-density data acquisition system based on generic electronics for TPCs (GET) has been installed and optimized to record and process the gas avalanche signals collected on the readout pads. The TPC's performance has been tested using a 220 Rn 𝛼-particle source and cosmic-ray muons. In addition, decay events in the TPC have been simulated by adapting the attpcroot data analysis framework. Furthermore, a novel application of two-dimensional convolutional neural networks for GADGET II event classification is introduced. The optimization of data throughput is also addressed. The GADGET II TPC is capable of detecting and identifying 𝛼 particles as well as measuring their track direction, range, and energy. The extracted energy resolution of the GADGET II TPC using P10 gas is about 5.4% at 6.288 MeV ( 220 Rn 𝛼 events), computed using charge integration. Based on a systematic simulation study, we estimated the detection efficiency of the GADGET II TPC for protons and 𝛼 particles, respectively. It has also been demonstrated that the GADGET II TPC is capable of tracking minimum-ionizing particles (i.e., cosmic-ray muons). From these measurements, the electron drift velocity was measured under typical operating conditions. In addition to being one of the first generation of micropattern gaseous detectors (MPGDs) to utilize a resistive anode applied to low-energy nuclear physics, the GADGET II TPC will also be the first TPC surrounded by a high-efficiency array of high-purity germanium 𝛾-ray detectors. As a result, the TPC of GADGET II has been designed, fabricated, and tested and is ready for operation at the Facility for Rare Isotope Beams for radioactive-beam-line experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Commissioning of an MPGD-based Drift Chamber for Heavy-ion Tracking in FRIB's Sweeper magnet system

A newly developed drift chamber equipped with an innovative hybrid Micro-Pattern Gaseous Detector based readout was commissioned at FRIB. The detector consists of a Multi-layer Thick Gas Electron Multiplier (M-THGEM) mounted over a high-granularity, position-sensitive readout board. Denoted as the Micro-Pattern Drift Chamber (MPDC), the new device is used to provide tracking capability as part of the detectors of the Sweeper magnet system for neutron-invariant-mass spectrometry at the Facility for Rare Isotope Beams (FRIB). The localization of impinging ions in a 30 × 30 cm 2 drift area is derived by processing the charge-avalanche distribution induced on the segmented readout board. The signals induced on the readout pads are processed by a compact, multi-channel Data Acquisition System (DAQ) based on the Scalable Readout System (SRS). To facilitate synchronization with other detector systems of the Sweeper magnet system, the SRS has been configured to accept an external trigger.

Gaseous detectors↗

A 24-channel ultra-low-noise preamplifier for dN/dx measurements with drift tube detectors

Cluster counting $(dN/dx)$ is a promising method to enhance particle identification for gaseous detectors, especially in next-generation collider experiments like the FCC-ee, where good $π/K$ separation over a broad momentum range is essential. However, its implementation in large-scale systems has been limited by the challenging requirements for high-resolution signal amplification and readout. This paper presents a 24-channel ultra-low-noise preamplifier board designed for drift tube detectors to enable $dN/dx$ measurements. The three-stage amplification topology employs SiGe transistors and integrates dedicated noise-minimization techniques, achieving a charge gain of 21.11 mV/fC from 0.3 fC to 50 fC, a bandwidth of 542 MHz, and a voltage gain of 47.8 dB. The measured voltage noise density is 0.35 nV/$\sqrt{\textrm{Hz}}$ , surpassing most of the state-of-the-art preamplifiers for gaseous and silicon detectors. Validation tests conducted on the sMDT chambers at the CERN Proton Synchrotron test beam facility demonstrate that the proposed design meets the stringent preamplifier requirements for implementing the $dN/dx$ method in drift-tube detector systems, achieving an equivalent noise charge of 0.14 fC and a signal-to-noise ratio of 73 when operated with a He:iC 4 H 10 (90:10) gas mixture. The design also shows promise for broader application in other gaseous or semiconductor detectors.

Drift tube detector↗

Development of Thin Gap GEM-µRWELL Hybrid Detectors at Jefferson Lab

Over the past few decades, Micro Pattern Gaseous Detector (MPGD) technologies have been increasingly adopted as tracking detector options in High Energy and Nuclear Physics experiments thanks to their good spatial resolution, high-rate capability, stability and more importantly their ability for large area coverage at a relatively low cost compared to the alternative. The thin gap GEM-µRWELL hybrid detector is the latest addition to the MPGD family, that was introduced to vastly improve the spatial resolution capability of gaseous trackers when deployed in the barrel region to cover large angular acceptance of the central tracker in a collider experiment. In this talk, I will re-introduce the concept and motivation for the development of thin gap GEM-µRWELL hybrid technology with an emphasis on the initial studies that establish the proof-of-concept of the technology. I will then discuss the more recent results from latest beam test campaign at Jefferson Lab in May 2025 to study detector efficiency performance with various gas mixtures. I will also briefly present the ongoing activities to develop large area thin gap GEM-µRWELL tracking detectors for the ePIC experiment of the future Electron Ion Collider as well as the exploration of the technology to provide large area tracking options to the muon system of experiments at a future Higgs Factory Collider such as the FCC-ee for example. Finally, I will conclude with some perspectives on new ideas under exploration to develop the next generation of thin gap MPGD technologies with enhanced timing and spatial resolution capabilities

Gnanvo, Kondo [Thomas Jefferson National Accelerat↗

Nucleon structure studies: DVCS on polarised protons with the CLAS12 experiment, and development of Micromegas detectors for EIC

The quark and gluon structure of nucleons is crucial for understanding the origin of their mass and spin. This information is encoded in structure function such as Generalised Parton Distributions (GPDs), which provide a three-dimensional picture of the nucleon in terms of its constituents. Deeply Virtual Compton Scattering (DVCS) offers the most direct access to GPDs, but their extraction requires high-precision measurements of multiple observables over a wide kinematic range. In 2022 and 2023 the CLAS12 experiment at Jefferson Lab (JLab) collected data from polarised electron scattering on a longitudinally polarised proton target, enabling the first measurement of polarised DVCS asymmetries at JLab 12GeV kinematics. This thesis will present preliminary measurement of the beam, target and double spin DVCS asymmetries from the CLAS12 polarised proton target data. Nucleon structure studies will also constitute a major part of the physics program at the future Electron Ion Collider (EIC). The development of the first detector at the EIC is ongoing and it requires light Micro-Pattern Gaseous Detectors (MPGDs) for its tracking system. This thesis further reports initial tests of Micromegas MPGDs with a two-dimensional readout developed for EIC.

Polcher, Samy [Univ. Paris-Saclay, Gif-sur-Yvette ↗

Fast timing with µRWELL-PICOSEC detector technology

The µWELL-PICOSEC detector, which is based on Resistive Micro-Well (µRWELL) technology, is a novel concept for fast timing gaseous detectors that can provide timing resolution in the tens of picosecond range, making it ideal candidate for time-of-flight (TOF) technology for particle identification (PID) in particle physics experiments as well as for future medical instrumentation. The µRWELL-PICOSEC concept is based on a Cerenkov radiator that produces Cerenkov photons from high energetic charged particles, a photocathode layer that converts the Cerenkov photons into primary electrons, a µRWELL amplification layer that multiply the electrons through amplification in a CF4-based gas mixture and a pad-segmentation anode readout coupled with fast timing electronics to provide fast signal. Beam tests were carried out at the CERN SPS H4 beamline in summer 2023 and 2024. Preliminary results show timing performance of the order of 23 ps achievable with µRWELL-PICOSEC prototype. and position scan of the 100-pads of a multi-channel prototype was also performed to study time response uniformity of large area detector. In this talk, after a brief overview of the PICOSEC technology, we will present recent results with different single channel µRWELL-PICOSEC prototype designs and also the position scan results of the 100-pads large prototype to study timing response uniformity for large area µRWELL-PICOSEC detector. Finally, we will discuss the ongoing R&D effort to further improve the timing resolution and allow good position capabilities through charge sharing for large area.

Gnanvo, Kondo↗

MPGD Trackers in the ePIC Detector at the EIC

The future Electron-Ion Collider (EIC) at Brookhaven National Laboratory will collide polarized electrons with polarized proton/ions. The electron ? Proton / Ion Collider (ePIC) Experiment is the EIC general-purpose detector aiming at delivering the full physics program of the EIC. This unique environment imposes stringent requirements on the tracking system needed for the measurement of the scattered electron and charged particles produced in the collisions at the EIC. The central tracker of the ePIC detector has silicon layers for tracking and vertexing based on MAPS technology, which are complemented by large Micro-Pattern Gaseous Detector (MPGD) trackers in the barrel and in both the electron and hadron end cap regions. The MPGD layers provide fast timing (10-20 ns) and additional hit points (150 µm) for pattern recognition during track finding. Two MPGD technologies are used in ePIC central trackers: cylindrical Micromegas for the barrel inner tracker and planar thin-gap GEM-µRWELL hybrid detector for the barrel outer tracker and the end cap disks. In this talk, we will introduce these two technologies in the context of ePIC and we will discuss the ongoing R&D efforts to address the requirements. Finally, we will discuss the plans and timeline for the production and testing and commissioning of the MPGD trackers for the installation in the ePIC detector.

Gnanvo, Kondo↗

Electron/hadron separation with the TRD based on GaAs pixel detectors

Transition Radiation Detectors (TRDs) are widely used for particle identification in both high-energy physics and astroparticle physics. They are typically equipped with gaseous detectors. The main limitation of these types of detectors is that TR photons and ionization losses cannot be decoupled, which significantly reduces the particle separation power. Recent advancements in the development of pixel detectors based on GaAs sensors offer a unique opportunity to effectively detect TR photons and separate them from ionization losses. Such detectors represent novel devices that combine precise tracking capabilities with particle identification (PID) properties. The present work is dedicated to an experimental study of particle identification properties of the TRD prototype based on 500 μ m-thick GaAs sensor bonded to a Timepix3 chip. Studies were performed at the CERN SPS and it was shown that at a particle momentum of 20 GeV/c, the probability of misidentifying a hadron as an electron is below 10 −2 for an electron detection efficiency of 98%–99%, and it is 1 . 6⋅10 −4 for electron detection efficiency of 90%. This performance surpasses the electron/hadron rejection power of all known TRDs by an order of magnitude for the same detector length.

GaAs detectors↗

Performance of a triple-GEM detector with capacitive-sharing 3-coordinate (X–Y–U)-strip anode readout

The concept of capacitive-sharing readout, described in detail in a previous study, offers the possibility for the development of high-performance three-coordinates (X--Y--U)-strip readout for Micro Pattern Gaseous Detectors (MPGDs) using simple standard PCB fabrication techniques. Capacitive-sharing (X--Y--U)-strip readout allows simultaneous measurement of the Cartesian coordinates x and y of the position of the particles together with a third coordinate u along the diagonal axis in a single readout PCB. This provides a powerful tool to address multiple-hit ambiguity and enable pattern recognition capabilities in moderate particle flux environment of collider or fixed target experiments in high energy physics HEP) and nuclear physics (NP). We present in this paper the performance of a 10 cm × 10 cm triple-GEM detector with capacitive-sharing (X--Y--U)-strip anode readout. Spatial resolutions of the order of $\sigma_{x}^{res}$ = 71.6 $\pm$ 0.8 $\mu$m for X-strips, $\sigma_{y}^{res}$ = 56.2 $\pm$ 0.9 $\mu$m for Y-strips and $\sigma_{u}^{res}$ = 75.2 $\pm$ 0.9 $\mu$m for U-strips have been obtained at a beam test at Thomas Jefferson National Accelerator Facility (Jefferson Lab). Modifications of the readout design of future prototypes to improve the spatial resolution and challenges in scaling to large-area MPGDs are discussed.

(X-Y-U) strip↗

Earth-catalyzed detection of magnetic inelastic dark matter with photons in large underground detectors

Inelastic dark matter with moderate splittings, $\mathcal{O}$ (few to 150) keV, can upscatter to an excited state in the Earth, with the excited state subsequently decaying, leaving a distinctive monoenergetic photon signal in large underground detectors. The photon signal can exhibit sidereal-daily modulation, providing excellent separation from backgrounds. Using a detailed numerical simulation, we examine this process as a search strategy for magnetic inelastic dark matter with the dark matter mass near the weak scale, where the upscatter to the excited state and decay proceed through the same magnetic dipole transition operator. At lower inelastic splittings, the scattering is dominated by moderate mass elements in the Earth with high spin, especially 27 Al, while at larger splittings, 56 Fe becomes the dominant target. We show that the proposed large volume gaseous detector CYGNUS will have excellent sensitivity to this signal. Xenon detectors also provide excellent sensitivity through the inelastic nuclear recoil signal, and if a future signal is seen, we show that the synergy among both types of detection can provide strong evidence for magnetic inelastic dark matter. In the course we have calculated nuclear response functions for elements relevant for scattering in the Earth, which are publicly available on GitHub.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mu2e straw tube tracker gas flow quality control

Here, we present a tracker gas flow quality control method developed for the Mu2e straw tube tracker. Using time-dependent current measurements, we quantify the onset time of ionization gain induced by an 55 F source during gas exchange, which is correlated to the gas conductance in the straw. This allows for the identification of channels with inadequate flow. This approach is broadly applicable to other gaseous detectors that require high-channel-count screening.

Flow↗

Experimental study of multiple-orientation muon tomography with image optimization in sparse data environments

Due to the high penetrating power of cosmic-ray muons, they can be used to probe very thick and dense objects. As muons are charged particles, they can be tracked by ionization detectors, determining the position and direction of the muons. With detectors on either side of an object to measure particle direction change, scattering information within the object can be found. This can be used to produce a scattering-intensity image within the object related to density and atomic number. Such imaging is typically performed with a single detector-object orientation, taking advantage of the more intense downward flux of muons, producing planar imaging with some depth-of-field information in the third dimension. Several simulation studies were published with multiorientation tomography, which can form a three-dimensional representation faster than a single-orientation view. In this study, experimental muon-scatter-based tomography was performed using a concrete filled steel drum with several different metal wedges inside, with the drum between detector planes. Data were collected from different detector-object orientations by rotating the steel drum. The data collected from each orientation were combined using two different tomographic methods. A traditional inverse Radon transform approach used for computed tomography and a combination of multiple depth-of-field reconstructions were applied to the data. As cosmic-ray muon flux imaging is rate limited, the imaging techniques were compared for sparse data. Using the combined depth-of-field reconstruction technique, fewer detector-object orientations were needed to reconstruct images that could be used to differentiate the metal wedges.

47 OTHER INSTRUMENTATION↗

SPY: a conceptual design study of a magnet system for a high-pressure gaseous TPC neutrino detector

Here, we present a novel conceptual design for a magnet system that provides the magnetic field necessary for the analysis of tracks in a high-pressure gaseous argon TPC while simultaneously serving as a pressure vessel to contain the TPC gas volume. The magnet was developed within a Near Detector proposal for the Deep Underground Neutrino Experiment (DUNE). The high-pressure gaseous argon TPC is a component proposed to be one of the elements of an ensemble of near detectors that are needed for DUNE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advancing Detector R&D for High-Pressure Gaseous Argon TPCs in Precision Neutrino Physics

High-pressure gaseous argon time projection chambers (HPgTPCs) represent an emerging detector paradigm for neutrino physics, combining increased target density with the intrinsic tracking and low thresholds of gaseous detectors. This approach enables detailed reconstruction of exclusive final states, improved particle identification, and sensitivity to low-energy and rare processes — capabilities that are increasingly central to precision oscillation measurements and searches for beyond-the-Standard-Model signatures. This abstract presents an overview of ongoing detector R&D toward high-pressure gaseous argon TPC operation, with emphasis on micro-pattern gas detector (MPGD) charge amplification in argon-based mixtures. We report experimental characterization of triple-GEM structures at pressures relevant for neutrino applications, including studies of multiplication factor scaling, stability, and operational voltage envelopes across gas admixtures. Measurements performed at the TOAD and GORG test stands at Fermilab help define viable amplification and electronics noise regimes in conditions where higher density imposes stricter constraints on signal formation. These results provide essential input to the optimization of high-pressure gaseous argon detectors for future neutrino experiments, including near-detector concepts such as ND-GAr in DUNE Phase II near detector upgrade. More broadly, this program shows how dedicated detector R&D can expand the precision frontier in neutrino physics by enabling complementary reconstruction capabilities beyond conventional detectors.

McConnell, Brenna [Indiana U.] (ORCID:000900041138↗

Readout electronics for low occupancy High-Pressure Gas TPCs

High-Pressure Gas Time Projection Chambers (HPgTPCs) have benefits such as low energy thresholds, magnetisability, and 4π acceptance, making them ideal for neutrino experiments such as DUNE. We present the design of an FPGA-based solution optimised for Gaseous Argon Near Detector (ND-GAr), which is part of the Phase-II more capable near detector for DUNE. These electronics reduce the cost significantly compared to using collider readout electronics, which are typically designed for much higher occupancy and therefore, for example, need much larger numbers of FPGAs and power per channel. We demonstrate the performance of our electronics with the Teststand for an Overpressurised Argon Detector (TOAD) at Fermilab in the US at a range of pressures and gas mixtures up to 4.5 barA, reading out ∼10 000 channels from a Multi-Wire Proportional Chamber (MWPC). The operation took place between April and July of 2024. We measure the noise characteristics of the system to be sufficiently low, and we identify sources of noise that can be further mitigated in the next iteration. We also note that the cooling scheme used in the test requires improvement before full-scale deployment. Despite these necessary improvements, we show that the system can fulfil the needs of a HPgTPC for a fraction of the price of collider readout electronics.

Data acquisition concepts↗