Search NASA⌕ Search

SEARCH · Search NASA

Results for “General procedures and instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Orion Crew Module Landing System Simulation and Verification

NASA Langley Research Center (LaRC) has developed a comprehensive test and analysis program to evaluate the ability of LS-DYNA to model the materials and the phenomena involved in soil and water landing impacts of the Orion crew module. Elemental, scale boilerplate, and full-scale prototype testing is being conducted in support of the simulation verification and validation approach. Aspects of the simulations evaluated against test data include soil constitutive properties, water equations of state, and contact algorithms. Subsystems tested include airbags, crushable energy absorbing honeycomb materials, and energy absorbing seat support struts. The procedures, instrumentation, and general observations from each test series are presented. Plans for a series of swing tests of a full-scale boilerplate into a purpose-built water basin are described. Further plans for swing tests of flight-like prototypes into the water basin are noted.

Vassilakos, Gregory J.↗

Measuring Thermodynamic Properties of Metals and Alloys With Knudsen Effusion Mass Spectrometry

This report reviews Knudsen effusion mass spectrometry (KEMS) as it relates to thermodynamic measurements of metals and alloys. First, general aspects are reviewed, with emphasis on the Knudsen-cell vapor source and molecular beam formation, and mass spectrometry issues germane to this type of instrument are discussed briefly. The relationship between the vapor pressure inside the effusion cell and the measured ion intensity is the key to KEMS and is derived in detail. Then common methods used to determine thermodynamic quantities with KEMS are discussed. Enthalpies of vaporization, the fundamental measurement, are determined from the variation of relative partial pressure with temperature using the second-law method or by calculating a free energy of formation and subtracting the entropy contribution using the third-law method. For single-cell KEMS instruments, measurements can be used to determine the partial Gibbs free energy if the sensitivity factor remains constant over multiple experiments. The ion-current ratio method and dimer-monomer method are also viable in some systems. For a multiple-cell KEMS instrument, activities are obtained by direct comparison with a suitable component reference state or a secondary standard. Internal checks for correct instrument operation and general procedural guidelines also are discussed. Finally, general comments are made about future directions in measuring alloy thermodynamics with KEMS.

Copland, Evan H.↗

Bayesian Statistical Models for Community Annoyance Survey Data

This paper demonstrates the use of two Bayesian statistical models to analyze single-event sonic boom exposure and human annoyance data from community response surveys. Each model is fit to data from a NASA pilot study.Unlike many community noise surveys, this study used a panel sample to collect multiple observations per participant instead of a single observation. Thus, a multilevel (also known as hierarchical or mixed-effects) model is used to account for the within-subject correlation in the panel sample data. This paper describes a multilevel logistic regression model and a multilevel ordinal regression model. The paper also proposes a method for calculating a summary dose-response curve from the multilevel models that represents the population. The two models’ summary dose-response curves are visually similar. However, their estimates differ when calculating the noise dose at a fixed percent highly annoyed.

Musical instruments↗

Small-angle neutron polarimetry apparatus (SANPA): Development at the NIST Center for Neutron Research

Spherical neutron polarimetry directly measures the rotation of the neutron polarization after scattering from materials with magnetic structure. It is an under utilized measurement technique that is capable of measuring all nine elements of the polarization tensor of a material. In this article, we describe our new cryogen-free small-angle neutron polarimetry apparatus and infrastructure at the NIST Center for Neutron Research. The resulting apparatus is capable of continuous operation and is designed for measurements at low temperatures (4–8 K) using niobium Meissner shielding and mu-metal shielding to produce a zero-field (≤1 μT) cooling sample environment.

47 OTHER INSTRUMENTATION↗

Online remote control systems for static and dynamic compression and decompression using diamond anvil cells

The ability to remotely control pressure in diamond anvil cells (DACs) in accurate and consistent manner at room temperature, and at cryogenic and elevated temperatures, is crucial for effective and reliable operation of a high-pressure synchrotron facility such as High Pressure Collaborative Access Team (HPCAT). Over the last several years, a considerable effort has been made to develop instrumentation for remote and automated pressure control in DACs during synchrotron experiments. We have designed and implemented an array of modular pneumatic (double-diaphragm), mechanical (gearboxes), and piezoelectric devices and their combinations for controlling pressure and compression/decompression rate at various temperature conditions from 4 K in cryostats to several thousand Kelvin in laser-heated DACs. Because HPCAT is a user facility and diamond cells for user experiments are typically provided by users, our development effort has been focused on creating different loading mechanisms and frames for a variety of existing and commonly used diamond cells rather than designing specialized or dedicated diamond cells with various drives. In this paper, we review the available instrumentation for remote static and dynamic pressure control in DACs and show some examples of their applications to high pressure research.

47 OTHER INSTRUMENTATION↗

Resolving small signal measurements in experimental plasma environments using calibrated subtraction of noise signals

The performance of many diagnostic and control systems within fusion and other fields of research are often detrimentally affected by spurious noise signals. This is particularly true for those (such as radiation or particle detectors) working with very small signals. Common sources of radiated and conducted noise in experimental fusion environments include the plasma itself and instrumentation. The noise complicates data analysis, as illustrated by noise on signals measured with the heavy ion beam probe (HIBP) installed on the Madison Symmetric Torus. The noise is time-varying and often exceeds the secondary ion beam current (in contrast with previous applications). Analysis of the noise identifies the dominant source as photoelectric emission from the detectors induced by ultraviolet light from the plasma. This has led to the development of a calibrated subtraction technique, which largely removes the undesired temporal noise signals from data. The advantages of the technique for small signal measurement applications are demonstrated through improvements realized on HIBP fluctuation measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Full-scale crash test of a CH-47C helicopter

A full-scale crash test of a large troop/cargo carrying CH-47C helicopter was conducted at the Langley impact dynamics research facility. The crash test of this large helicopter was performed as part of a joint U.S. Army-NASA helicopter test program to provide dynamic structural and seat response data. The test, the procedures employed, the instrumentation, a general assessment of the resulting damage, and typical levels of accelerations experienced during the crash are reported. Various energy-absorbing seating systems for crew and troops were installed and instrumented to provide data for use in the development of design criteria for future aircraft. The crash conditions were selected to simulate known crash conditions and are representative of the 95th percentile accident environment for an autorotating helicopter. Visual examination of the crashed test specimen indicated irreparable damage to many of the structural components. The highest accelerations were recorded by the accelerometers located on the cabin floor in the aft section of the helicopter, directly above the primary impact location and on the floor of the cockpit above the secondary impact location(s).

Castle, C. B.↗

Analytical procedure for evaluating speckle-effect instrumentation

A general analysis suitable for developing speckle effect instruments and a simplified analysis suitable for evaluating laser speckle instrumentation are presented. The simplified analysis is summarized as a list of equations. Several sample applications are discussed.

Decker, A. J.↗

The M68HC11 gripper controller electronics

This document describes the instrumentation, operational theory, circuit implementation, calibration procedures, and general notes for the CIRSSE general purpose pneumatic hand. The mechanical design and the control software are discussed. The circuit design, PCB layout, hand instrumentation, and controller construction described in detail in this document are the result of a senior project.

Kelley, Robert B.↗

Fast, High-Resolution X-ray Microfluorescence Imaging

X-ray micro fluorescence imaging refers to the use of an x-ray beam as a probe to excite XRF in a specimen and produce a spatially resolved image of the element distribution. The advantages of high sensitivity and low background, together with the nondestructive nature of the measurement, have lead to applications of x-ray microfluorescence analysis in biology, geology, materials science, as well as in the area of nondestructive evaluation. Previous reports have described the development of an x-ray microprobe which uses a conventional source of x-rays to produce a 10-μm beam. This paper describes improvements to the microprobe which have increased the beam power and the solid angle of detection. The data collection and display software have also been enhanced.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Flight Experiment Investigation of General Aviation Self-Separation and Sequencing Tasks

A new flight operations concept called Small Aircraft Transportation System (SATS) Higher Volume Operations (HVO) was developed to increase capacity during Instrument Meteorological Conditions (IMC) at non-towered, non-radar airports by enabling concurrent operations of multiple aircraft. One aspect of this concept involves having pilots safely self-separate from other aircraft during approaches into these airports using appropriate SATS HVO procedures. A flight experiment was conducted to determine if instrument-rated general aviation (GA) pilots could self-separate and sequence their ownship aircraft, while following a simulated aircraft, into a non-towered, non-radar airport during simulated IMC. Six GA pilots' workload levels and abilities to perform self-separation and sequencing procedures while flying a global positioning system (GPS) instrument approach procedure were examined. The results showed that the evaluation pilots maintained at least the minimum specified separation between their ownship aircraft and simulated traffic and maintained their assigned landing sequence 100-percent of the time. Neither flight path deviations nor subjective workload assessments were negatively impacted by the additional tasks of self-separating and sequencing during these instrument approaches.

Murdoch, Jennifer L.↗

Introduction to IdentiFINDERs

These are slides from a presentation. The identiFINDER provides information on radiation levels. It can automatically identify isotopes in its library. It can save spectra for transfer to a computer, and has a 4-8 hour battery life. The following is covered: an overview, operating modes, getting started, finder mode, search, identification mode, dose & rate, warning & alarm, options (ultra LGH), options (identifinder2), and general procedure.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heteronuclear Correlation SSNMR Spectroscopy with Indirect Detection under Fast Magic-Angle Spinning [Book Chapter]

The main focus of this chapter is to address experimental strategies on the subject by providing a hands-on guide to fast MAS experiments, with a particular focus on indirect detection. Although our experience is limited to our respective laboratories in Ames and Yokohama, we hope that our descriptions of experimental setups and optimization procedures are sufficiently general to be applicable to all modern instruments. The chapter is organized as follows. Section 2 below introduces briefly the fast MAS technology and its main advantages. In Section 3, we describe the hardware associated with this remarkable technology and provide practical advices on its use, including procedures for loading and unloading the samples, maintaining the probe, reducing t 1 noise, etc. In Section 4, we describe the principles and hands-on aspects of experiments involving the indirect detection of spin-1/2 and 14 N nuclei

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Alignment of Optical Backscatter Measurements from the EXPORTS Northeast Pacific Field Deployment

Backscattering of light is commonly measured by ocean observing systems, including ships and autonomous platforms, and is used as a proxy for the concentration of water column constituents such as phytoplankton and particulate carbon. Multiple on-going projects involve large numbers of independent measurements of backscatter, as well as other biologically relevant parameters, to understand how biology is changing in time and space throughout the global ocean. Rarely are there sufficient measurements to test how well these instruments are inter-calibrated in real-world deployment conditions. This paper develops a procedure to align multiple independently calibrated backscatter instruments to each other using nearby profiling casts and applies this method to nine instruments deployed during a recent field campaign in the North Pacific during August–September of 2018. This process revealed several incorrect calibrations; post-alignment, all nine instruments aligned extremely well with each other. We also tested an alignment to a deep-water reference and found that this method is generally sufficient but has significant limitations; this procedure lacks the ability to correct instruments measuring only shallow profiles and can only account for additive offsets, not multiplicative changes. These findings highlight the utility of process studies involving several independent measurements of similar parameters in the same area.

North Pacific↗

Efficient Levenberg-Marquardt minimization of the maximum likelihood estimator for Poisson deviates

Histograms of counted events are Poisson distributed, but are typically fitted without justification using nonlinear least squares fitting. The more appropriate maximum likelihood estimator (MLE) for Poisson distributed data is seldom used. We extend the use of the Levenberg-Marquardt algorithm commonly used for nonlinear least squares minimization for use with the MLE for Poisson distributed data. In so doing, we remove any excuse for not using this more appropriate MLE. We demonstrate the use of the algorithm and the superior performance of the MLE using simulations and experiments in the context of fluorescence lifetime imaging. Scientists commonly form histograms of counted events from their data, and extract parameters by fitting to a specified model. Assuming that the probability of occurrence for each bin is small, event counts in the histogram bins will be distributed according to the Poisson distribution. We develop here an efficient algorithm for fitting event counting histograms using the maximum likelihood estimator (MLE) for Poisson distributed data, rather than the non-linear least squares measure. This algorithm is a simple extension of the common Levenberg-Marquardt (L-M) algorithm, is simple to implement, quick and robust. Fitting using a least squares measure is most common, but it is the maximum likelihood estimator only for Gaussian-distributed data. Non-linear least squares methods may be applied to event counting histograms in cases where the number of events is very large, so that the Poisson distribution is well approximated by a Gaussian. However, it is not easy to satisfy this criterion in practice - which requires a large number of events. It has been well-known for years that least squares procedures lead to biased results when applied to Poisson-distributed data; a recent paper providing extensive characterization of these biases in exponential fitting is given. The more appropriate measure based on the maximum likelihood estimator (MLE) for the Poisson distribution is also well known, but has not become generally used. This is primarily because, in contrast to non-linear least squares fitting, there has been no quick, robust, and general fitting method. In the field of fluorescence lifetime spectroscopy and imaging, there have been some efforts to use this estimator through minimization routines such as Nelder-Mead optimization, exhaustive line searches, and Gauss-Newton minimization. Minimization based on specific one- or multi-exponential models has been used to obtain quick results, but this procedure does not allow the incorporation of the instrument response, and is not generally applicable to models found in other fields. Methods for using the MLE for Poisson-distributed data have been published by the wider spectroscopic community, including iterative minimization schemes based on Gauss-Newton minimization. The slow acceptance of these procedures for fitting event counting histograms may also be explained by the use of the ubiquitous, fast Levenberg-Marquardt (L-M) fitting procedure for fitting non-linear models using least squares fitting (simple searches obtain {approx}10000 references - this doesn't include those who use it, but don't know they are using it). The benefits of L-M include a seamless transition between Gauss-Newton minimization and downward gradient minimization through the use of a regularization parameter. This transition is desirable because Gauss-Newton methods converge quickly, but only within a limited domain of convergence; on the other hand the downward gradient methods have a much wider domain of convergence, but converge extremely slowly nearer the minimum. L-M has the advantages of both procedures: relative insensitivity to initial parameters and rapid convergence. Scientists, when wanting an answer quickly, will fit data using L-M, get an answer, and move on. Only those that are aware of the bias issues will bother to fit using the more appropriate MLE for Poisson deviates. However, since there is a simple, analytical formula for the appropriate MLE measure for Poisson deviates, it is inexcusable that least squares estimators are used almost exclusively when fitting event counting histograms. There have been ways found to use successive non-linear least squares fitting to obtain similarly unbiased results, but this procedure is justified by simulation, must be re-tested when conditions change significantly, and requires two successive fits. There is a great need for a fitting routine for the MLE estimator for Poisson deviates that has convergence domains and rates comparable to the non-linear least squares L-M fitting. We show in this report that a simple way to achieve that goal is to use the L-M fitting procedure not to minimize the least squares measure, but the MLE for Poisson deviates.

59 BASIC BIOLOGICAL SCIENCES↗

Instrumentation for one-way satellite PTTI applications

A review of general principles and operational procedures illustrates how the typical passive user and omni receiving antenna can recover Precise Time and Time Interval (PTTI) information from a low altitude navigation satellite system for clock calibration and synchronization. Detailed discussions of concepts and theory of the receiver design are presented. The importance of RF correlation of the received and local PN encoded sequences is emphasized as a means of reducing delay uncertainties of the instrumentation to values compatible with nanosecond to submicrosecond PTTI objectives. Two receiver configurations were fabricated for use in satellite-to-laboratory experiments. In one receiver the delay-locked loop for PN signals synchronization used a dithered amplitude detection process while the second receiver used a complex sums phase detection method for measurement of delay error. The necessity for compensation of Doppler shift is discussed. Differences in theoretical signal acquisition and tracking performance of the design concepts are noted.

Osborne, A. E.↗

Development and evaluation of a prototype in-flight instrument flight rules (IFR) procedures trainer

An in-flight instrument flight rules (IFR) procedures trainer capable of providing simulated indications of instrument flight in a typical general aviation aircraft independent of ground based navigation aids was developed. The IFR navaid related instruments and circuits from an ATC 610J table top simulator were installed in a Cessna 172 aircraft and connected to its electrical power and pitot static systems. The benefits expected from this hybridization concept include increased safety by reducing the number of general aviation aircraft conducting IFR training flights in congested terminal areas, and reduced fuel use and instruction costs by lessening the need to fly to and from navaid equipped airports and by increased efficiency of the required in-flight training. Technical feasibility was demonstrated and the operational feasibility of the concept was evaluated. Results indicated that the in-flight simulator is an effective training device for teaching IFR procedural skills.

Aaron, J. B., Jr.↗