Search NASASearch

SEARCH · Search NASA

Results for “Godiva IV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Godiva IV central cavity neutron environment characterization with threshold neutron detectors

Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high-purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.

Whitman, Nicholas H.

Godiva IV Simulated Radiation Field Characterization and Variance Reduction

Godiva IV is a system comprised of highly enriched uranium alloyed with molybdenum in the form of fuel plate rings. The reactor, along with its predecessors, was designed with the unique ability to satisfy interests in the super-prompt-critical reactor operation space. Originally, the reactor was part of the Los Alamos Critical Experiments Facility (LACEF) at Technical Area-18 (TA-18). The radiation field around Godiva at this facility was well characterized and understood. As a fast neutron system, the neutron spectrum in and around Godiva was close to a Watt Fission spectrum. The Kiva where Godiva IV was located at LACEF was made of thin, sheet metal walls which did not contribute significantly to the neutron spectrum. Following the transition of LACEF to the National Critical Experiments and Research Center (NCERC) in Nevada, Godiva-IV was moved from TA-18 to the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS). Part of this move brought renewed interest in radiation field characterization. The new facility introduced significant changes to the environment surrounding Godiva, and preliminary foil irradiation results suggested that the room contribution to the neutron spectrum was significant. Unlike at TA-18, a large thermal neutron signature was added to the fast spectrum from Godiva due to significant room return. A primary goal due to the additional complexity that the room return adds to the Godiva IV radiation emission spectrum was the development of an efficient Monte Carlo N-Particle (MCNP) calculation capable of characterizing the neutron spectrum anywhere in the room around Godiva. A campaign of activation foil irradiations and analysis were completed to support the validation of the MCNP model. The modeling of these foils in MCNP can be easily done with a standard volumetric neutron flux tally. However, given the multitude of locations and reaction rates to be modeled, further steps must be taken to increase the efficiency of these calculations in MCNP. During this study, a benchmark model currently under development for Godiva IV was used. A qualitative assessment of the thermal neutron contributors was performed using spatial neutron distribution plots. Additional detail was added to the model based on the qualitative results showing the thermal spectrum’s large sensitivity to hydrogenous material. Neutron energy spectra was evaluated at discrete locations in the room around Godiva to quantify the relative contribution of various components. It was discovered that the concrete walls are the largest contributor to the thermal signature, with minor contributions from plastic components surrounding Godiva. Following these results, two different variance reduction techniques were implemented to improve the problem efficiency in these calculations. In the first approach, an F5 point detector tally was implemented in the standard Godiva IV criticality problem. The second approach involved a weight-window generator implementation with an F5 point detector tally in a fixed source problem. The weight window implementation reduced the runtime from 42739.55 minutes to 1803.34 minutes (computer time), compared to the F5 KCODE implementation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Godiva IV Thermal Neutron Dosimetry Modeling and Variance Reduction

The transfer of the Godiva IV experiment from the Los Alamos Critical Experiments Facility (LACEF) to the National Critical Experiments Research Center (NCERC) introduced a vastly different experiment room return to the neutron flux. The contribution of the background to the burst neutron energy spectrum is significant in the thermal and epithermal neutron energies. Target materials may be placed in various locations in the Godiva room, or outside of the room, for thermal neutron activation. Modeling of this dosimetry problem in Monte Carlo N-Particle (MCNP) presented a novel challenge compared to previous Godiva IV glory hole irradiation simulations. An advanced dosimetry modeling framework for high efficiency calculations in locations far from the Godiva IV fission source was desired. The mesh-based weight windows and point detector advanced variance reduction techniques in MCNP were implemented and tested using adaptations of the critical experiment benchmark model of the Godiva IV problem. The models were validated against measured activations of Nickel, Indium, Scandium, and Cobalt foils at locations 2 meters from the Godiva IV core. Dosimetry measurements were performed in collaboration with Sandia National Laboratory. The weight windows and point detector variance reduction coupled method resulted in the highest problem efficiency.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

A neutron fluence map of the Los Alamos National Laboratory Godiva IV critical assembly

A neutron fluence map and a total ionizing dose map of the Los Alamos National Laboratory Godiva IV fast burst critical assembly was generated using passive reactor dosimetry, comprised of sulfur pellets and thermoluminescent dosimeters. Godiva IV is an unmoderated, fast burst, critical assembly constructed of approximately 65 kg of highly enriched uranium fuel alloyed with 1.5 % molybdenum for strength. The mapping was performed during a single 75.6 ºC temperature rise burst operation, with the top and sides of the cylindrical Godiva-IV Top Hat covered in passive dosimetry. Dosimetry was placed in a symmetric pattern around the Top Hat, with higher concentrations near the control rods and burst rod. A specific portion of the lower quadrant of the burst rod was mapped to confirm a testing region where the neutron fluence varied by no more than ± 5%. The results will be used to assess the neutron, gamma, and total ionizing dose environment in three-dimensional space around the assembly for higher fidelity experiment placement, active dosimetry positioning, and radiation field characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

New constraint on the Np 237 ( n , γ ) Np 238 integral cross section using the Godiva-IV critical assembly

Accurate knowledge of the 237 Np(n, γ) 238 Np cross section at fast neutron energies is important for applied nuclear science. The presently available experimental data has large disagreements in the fast neutron region. Perform a model-independent measurement of the 237 Np(n, γ) 238 Np integral cross section using a well characterized fast neutron source and compare the result with previous measurements and current nuclear data evaluations. Provide an integral measurement that can be used as a benchmark for current evaluations. Multiple samples of 237 Np were irradiated in the Godiva-IV critical assembly. Following the irradiation, the samples placed in a γ-ray counting setup and the γ-rays emitted from the decay of 238 Np were measured over a time period of approximately 7 days. Multiple γ-ray decay branches of 238 Np were observed. The observed activity of 238 Np was used to calculate the amount of 238 Np produced during the irradiation via the 237 Np(n, γ) 238 Np reaction and an integral cross section of 342(11) mb was measured for the Godiva-IV neutron spectrum. Further, the 238 Np half-life has been measured with a result of 50.31(5) hours. The 237 Np(n, γ) 238 Np integral cross section measured in this work is in agreement with overlapping 1σ error bands to ENDF/B-VIII.0. However, the measured value is 3σ away from the calculated integral cross section using JENDL-5. This measurement offers a reliable benchmark for future 237 Np(n, γ) 238 Np cross section evaluations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS

Radiation Characterization Summary: Godiva IV Critical Assembly Environments at the In-Core, Top Hat, 1m, and 2m Irradiation Locations

This document presents the facility-recommended characterization of the neutron, prompt gamma ray, and delayed gamma ray radiation fields at the Godiva IV critical assembly at the National Criticality Experiments Research Center (NCERC). The environments assessed include the In-Core location, a location on the Top Hat, 1m away from the assembly, and 2m away from the assembly. The neutron, prompt gamma ray, and delayed gamma ray energy spectra, uncertainties, and covariance matrices are presented as well as radial and axial neutron and gamma ray fluence profiles on the Top Hat surrounding the critical assembly. Recommended constants are given to facilitate the conversion of various dosimetry readings into radiation metrics desired by experimenters. Representative pulse operations are presented with conversion examples.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Au-198 and TLD-600 results from IER-593 Godiva irradiations

This report summarizes the results from dosimetry packets deployed during a nominally 250 ◦C temperature rise Godiva IV burst. Dosimetry packets including Bare Au foils, Cd covered Au foils, and Thermoluminescent Dosimeters (TLDs) were deployed at five positions around Godiva at a height corresponding to the center height of the HEU fuel.

61 RADIATION PROTECTION AND DOSIMETRY

NCERC 2024 Highlights

The National Nuclear Security Administration (NNSA) is entrusted with ensuring the safety, security, and reliability of the nation’s nuclear weapons stockpile while advancing programs aimed at reducing global nuclear proliferation. These critical mission objectives are achieved through the expertise of a highly skilled team of professionals. The operations at the National Criticality Experiments Research Center (NCERC) play a vital role in developing and enhancing knowledge and expertise in advanced nuclear technologies. NCERC supports a wide range of mission areas, including nuclear criticality safety, nuclear emergency response, and nuclear nonproliferation, safeguards, and arms control. It also provides support to the Department of Homeland Security, advances stockpile stewardship science, and delivers scientific expertise to other government agencies, such as NASA and the Defense Threat Reduction Agency. NCERC conducts experiments utilizing diverse nuclear materials, from small neutron-emitting sources for testing radiation detection equipment to larger quantities of uranium and plutonium for criticality experiments. A cornerstone of NCERC's mission portfolio includes the operation of four critical mass assembly machines—Planet, Comet, Flattop, and Godiva-IV—which are instrumental in advancing nuclear science and ensuring the nation’s nuclear security objectives.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

193 mIr/ 192 Ir ratio from irradiation with various NCERC critical assemblies

Eight irradiations of K 2 IrCl 6 pellets were carried out with three critical assemblies: Flattop-Oy, Flattop-Pu and Godiva IV. One of the irradiations was performed with three pellets at different locations of the critical assembly, while the other irradiations with pellets at the center, but operating the critical assembly at different power and, respectively, different neutron flux. Counting samples were prepared from the irradiated pellets and X-ray spectra measured with silicone drift detectors. The 193 mIr/ 192 Ir ratio is reported for each irradiation.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA