Search NASA⌕ Search

SEARCH · Search NASA

Results for “Graft”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Assessment of internal mammary artery and saphenous vein graft patency and flow reserve using transthoracic Doppler echocardiography

OBJECTIVE: To investigate transthoracic Doppler echocardiography in the identification of coronary artery bypass graft (CABG) flow for assessing graft patency. DESIGN: The initial study group comprised 45 consecutive patients with previous CABG undergoing elective cardiac catheterisation for recurrent ischaemia. The Doppler variables best correlated with angiographic graft patency were then tested prospectively in a further 84 patients (test group). SETTING: Three tertiary referral centres. INTERVENTIONS: Flow velocities in grafts were recorded at rest and during hyperaemia induced by dipyridamole (0.56 mg/kg/4 min), under the guidance of transthoracic colour Doppler flow mapping. Findings on transthoracic Doppler were compared with angiography. MAIN OUTCOME MEASURES: Feasibility of identifying open grafts by Doppler and diagnostic accuracy for Doppler detection of significant (>/= 70%) graft stenosis. RESULTS: In the test group the identification rate for mammary artery grafts was 100%, for saphenous vein grafts to left anterior descending coronary artery 91%, for vein grafts to right coronary artery 96%, and for vein grafts to circumflex artery 90%. Coronary flow reserve (the ratio between peak diastolic velocity under hyperaemia and at baseline) of < 1.9 (95% confidence interval 1.83 to 2.08) had 100% sensitivity, 98% specificity, 87.5% positive predictive value, and 100% negative predictive value for mammary artery graft stenosis. Coronary flow reserve of < 1.6 (95% CI 1.51 to 1.73) had 91% sensitivity, 87% specificity, 85.4% positive predictive value, and 92.3% negative predictive value for significant vein graft stenosis. CONCLUSIONS: Transthoracic Doppler can provide non-invasive assessment of CABG patency.

Multicenter Study↗

Electrostrictive Graft Elastomers

An electrostrictive graft elastomer has a backbone molecule which is a non-crystallizable, flexible macromolecular chain and a grafted polymer forming polar graft moieties with backbone molecules. The polar graft moieties have been rotated by an applied electric field, e.g., into substantial polar alignment. The rotation is sustained until the electric field is removed. In another embodiment, a process for producing strain in an elastomer includes: (a) providing a graft elastomer having a backbone molecule which is a non-crystallizable, flexible macromolecular chain and a grafted polymer forming polar graft moieties with backbone molecules; and (b) applying an electric field to the graft elastomer to rotate the polar graft moieties, e.g., into substantial polar alignment.

Su, Ji↗

The effect of interstitial air on the in vitro thrombogenicity of ePTFE vascular grafts

Gas trapped in the interstices of the biomaterials used for vascular prostheses causes thrombosis, and the process of eliminating this gas is known as denucleation. An apparatus was developed for testing in the in vitro effects of denucleation on 4 mm I.D. expanded polytetrafluoroethylene (ePTFE) Vitagraft (Johnson and Johnson). The apparatus was designed to ensure that neither the blood nor the grafts came in contact with air. Blood from a single donor was incubated with control and denucleated grafts for 5, 10, 15, 20, and 30 minutes. The thrombus volume in the graft lumen was measured with a computer assisted videometric system. Little thrombus formed by 5 or 10 minutes, but there was less thrombus in the denucleated graft than in the control graft at all times. The differences were statistically significant at 15 and 20 minutes (p < 0.05). Denucleation nearly doubled the thrombus formation time. Thrombus was more adherent to denucleated grafts than to control grafts. These results are consistent with in vivo observations in the rat where denucleation decreased thrombus formation and increased patency duration.

NASA Discipline Number 04-10↗

Grafting of 2 (2-hydroxy-5-vinylphenyl) 2H-benzotriazole onto polymers with aliphatic groups. Synthesis and polymerization of 2 (2-hydroxy-5-isopropenylphenyl) 2H-benzotriazole and a new synthesis of 2 (2-hydroxy-5-vinylphenyl) 2H-benzotriazole

Successful grafting of 2(2-hydroxy-5-vinylphenyl)2H-benzotriazole onto saturated aliphatic C-H groups of polymers has been accomplished. When the grafting reaction was carried out in chlorobenzene at 150 C = 160 C with di-tertiarybutylperoxide as the grafting initiator, grafts as high as 20 percent - 30 percent at a grafting efficiency of 50 percent and 80 percent have readily been obtained. The grafting reaction was carried out in tubes sealed under high vacuum since trace amounts of oxygen cause complete inhibition of the grafting reaction by the phenolic monomer. On a variety of different polymers including atactic polypropylene, ethylene/vinyl acetate copolymer, poly(methyl methacrylate), poly(butyl acrylate), and polycarbonate were used.

Pradellok, W.↗

Polyether-polyester graft copolymer

Described is a polyether graft polymer having improved solvent resistance and crystalline thermally reversible crosslinks. The copolymer is prepared by a novel process of anionic copolymerization. These polymers exhibit good solvent resistance and are well suited for aircraft parts. Previous aromatic polyethers, also known as polyphenylene oxides, have certain deficiencies which detract from their usefulness. These commercial polymers are often soluble in common solvents including the halocarbon and aromatic hydrocarbon types of paint thinners and removers. This limitation prevents the use of these polyethers in structural articles requiring frequent painting. In addition, the most popular commercially available polyether is a very high melting plastic. This makes it considerably more difficult to fabricate finished parts from this material. These problems are solved by providing an aromatic polyether graft copolymer with improved solvent resistance and crystalline thermally reversible crosslinks. The graft copolymer is formed by converting the carboxyl groups of a carboxylated polyphenylene oxide polymer to ionic carbonyl groups in a suitable solvent, reacting pivalolactone with the dissolved polymer, and adding acid to the solution to produce the graft copolymer.

Bell, Vernon L.↗

Graft copolymers from poly(2,6-dimethylphenylene oxide) and pivalolactone

The copolyether-polyester system resulting from the anionic graft polymerization of pivalolactone onto poly(2,6-dimethylphenylene oxide) has been formulated with differing graft densities and graft segment lengths. Wide angle X-ray scattering studies on these materials indicated an increased crystalline order with increased PVL segments/graft for similarly annealed specimens and a decrease in such order with increasing carboxylation.

Bell, Vernon L.↗

Electrostrictive Graft-Elastomers (G-Elastomers) - Materials, Devices and Applications - A Review

Electroactive polymers, especially electromechanically active polymers, have drawn extensive attention worldwide since the piezoelectricity and ferroelectricity of poly (vinylidene fluoride) (PVDF) was discovered in 1969. In the past three decades, several new classes of electroactive polymers that demonstrate promising electromechanical properties have been developed. Electrostrictive Graft Elastomers (G-elastomer) developed at NASA Langley Research Center have been recognized as one of the more promising electroactive polymers due to their large electric field-induced strain (~4%) and high mechanical modulus (~700 MPa). Electromechanical performance of the G-elastomer is a promising class of electroactive polymer materials because it exhibits a novel molecular mechanism that allows enhancement in the field induced strain and in the mechanical modulus synergistically. The combination of large induced strain and high mechanical modulus allows the electrostrictive graft elastomer to offer very promising electromechanical properties, in terms of output mechanical energy density, making it plausible as a candidate for use in high performance and low mass actuation devices in various aerospace applications. In this presentation, the molecular structures, properties, processing and mechanisms of the electromechanical performance, as well as its applications in actuation devices for advanced aerospace technologies, will be comprehensively reviewed and discussed.

Polymer↗

Polyether/Polyester Graft Copolymers

Higher solvent resistance achieved along with lower melting temperature. New technique provides method of preparing copolymers with polypivalolactone segments grafted onto poly (2,6-dimethyl-phenylene oxide) backbone. Process makes strong materials with improved solvent resistance and crystalline, thermally-reversible crosslinks. Resulting graft copolymers easier to fabricate into useful articles, including thin films, sheets, fibers, foams, laminates, and moldings.

Bell, Vernon L., Jr.↗

Electrostrictive Graft Elastomers and Applications

Efficient actuators that are lightweight, high performance and compact are needed to support telerobotic requirements for future NASA missions. In this work, we present a new class of electromechanically active polymers that can potentially be used as actuators to meet many NASA needs. The materials are graft elastomers that offer high strain under an applied electric field. Due to its higher mechanical modulus, this elastomer also has a higher strain energy density as compared to previously reported electrostrictive polyurethane elastomers. The dielectric, mechanical and electromechanical properties of this new electrostrictive elastomer have been studied as a function of temperature and frequency. Combined with structural analysis using x-ray diffraction and differential scanning calorimetry on the new elastomer, structure-property interrelationship and mechanisms of the electric field induced strain in the graft elastomer have also been investigated. This electroactive polymer (EAP) has demonstrated high actuation strain and high mechanical energy density. The combination of these properties with its tailorable molecular composition and excellent processability makes it attractive for a variety of actuation tasks. The experimental results and applications will be presented.

Su, J.↗

Model For Bending Actuators That Use Electrostrictive Graft Elastomers

Recently, it was reported that an electrostrictive graft elastomer exhibits large electric field-induced strain (4%). Combined with its high mechanical modulus, the elastomer can offer very promising electromechanical properties, in terms of output mechanical energy density, for an electroactive polymeric material. Therefore, it has been considered as one of the candidates that can be used in high performance, low mass actuation devices in many aerospace applications. Various bilayer- based bending actuators have been designed and fabricated. An analytic model based on beam theory in the strength of materials has been derived for the transverse deflection, or curvature, and the longitudinal strain of the bi-layer beam. The curvature and strain are functions of the applied voltage and the thickness, width, and Young s modulus of the active and passive layers. The model can be used to optimize the performance of electrostrictive graft elastomer-based actuators to meet the requirements of various applications. In this presentation, optimization and sensitivity studies are applied to the bending performance of such actuators.

Costen, Robert C.↗

Ferroelectric and Piezoelectric Properties of Blends of Poly(Vinylidene-Trifluoroethylene) and Graft Elastomer

A piezoelectric polymeric blend system has been developed. The system contains two components: ferroelectric poly(vinylidene-trifluoroethylene) and graft elastomer. The remanent polarization, Pr, and the piezoelectric strain coefficient, d31, of the blends have been studied as a function of relative composition of the two components, temperature and frequency. Both blended copolymer and graft unit in the elastomer contribute to the total crystallinity of the blend-system, and hence to the remanent polarization and piezoelectricity. The piezoelectric strain coefficient, d31, of the blend systems shows dependence on both the remanent polarization and the mechanical stiffness, which in turn are determined by the fraction of the two components in the blends. This mechanism makes it possible for the piezoelectric strain response of the blend to be tailored by adjusting the relative composition. Although Pr of the copolymer is higher than that of the blends, the blend films containing 75 wt.% copolymer exhibit a higher d31 at room temperature, possibly due to their lower modulus. The blend films containing 50 wt.% copolymer exhibit a constant value of d31, from room temperature to 70 C.

Su, J.↗

Methods of Attaching or Grafting Carbon Nanotubes to Silicon Surfaces and Composite Structures Derived Therefrom

The present invention is directed toward methods of attaching or grafting carbon nanotubes (CNTs) to silicon surfaces. In some embodiments, such attaching or grafting occurs via functional groups on either or both of the CNTs and silicon surface. In some embodiments, the methods of the present invention include: (1) reacting a silicon surface with a functionalizing agent (such as oligo(phenylene ethynylene)) to form a functionalized silicon surface; (2) dispersing a quantity of CNTs in a solvent to form dispersed CNTs; and (3) reacting the functionalized silicon surface with the dispersed CNTs. The present invention is also directed to the novel compositions produced by such methods.

Tour, James M.↗

Fatal Saccharomyces Cerevisiae Aortic Graft Infection

Saccharomyces cerevisiae is a yeast commonly used in baking and a frequent colonizer of human mucosal surfaces. It is considered relatively nonpathogenic in immunocompetent adults. We present a case of S. cerevisiae fungemia and aortic graft infection in an immunocompetent adult. This is the first reported case of S. cerevisiue fungemia where the identity of the pathogen was confirmed by rRNA sequencing.

Meyer, Michael↗

Interposition vein graft for giant coronary aneurysm repair

Coronary aneurysms in adults are rare. Surgical treatment is often concomitant to treating obstructing coronary lesions. However, the ideal treatment strategy is poorly defined. We present a case of successful treatment of a large coronary artery aneurysm with a reverse saphenous interposition vein graft. This modality offers important benefits over other current surgical and percutaneous techniques and should be considered as an option for patients requiring treatment for coronary aneurysms.

Non-NASA Center↗