Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gram determinant”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Amplitude/operator basis in chiral perturbation theory

We establish a systematic construction of the on-shell amplitude/operator basis for Chiral Perturbation Theory (ChPT) in D = 4 spacetime dimensions and with an arbitrary number of flavors N f . For kinematic factors, we employ spinor-helicity variables to construct the soft blocks, which are local amplitudes satisfying the Adler’s zero condition, as well as to take into account the reduction in the kinematic basis due to the Gram determinant, which arises at O(p 10 ) when the number of multiplicity N in an amplitude becomes large: N > D. For flavor factors, we include group-theoretic relations at small N f , N f ≤ N, which decreases the flavor basis. The result is obtained by adapting the Young tensor method of constructing the operator basis for generic effective field theories to the case of non-linearly realized symmetries. Working in the massless quark limit, we present purely mesonic operators for both even- and odd-parity at O(p 6 ) and O(p 8 ) for N = 6 and arbitrary N f , and establish a direct correspondence between the amplitude basis and the operator basis. Furthermore, the redundancy due to the Gram determinant is studied at O(p 10 ) for N = 6, 8 and 10.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Independent Constituents in Observatory Time Series in Characterizing the Secular Variation

By an ansatz of a finite set of N superimposed oscillations, observatory time series are fitted. This start model is optimized for the independence of the used 2N-dimensional functional system as a criterion. Here, the contributions of each of the dimensions to the volume of the corresponding 2N-dimensional parallelpiped of the functional space is to be evaluated. Independence and an equal standard for the constituents are achieved by the optimizing procedure varying the start values of frequencies in the fitting ansatz when quotients of successively constructed Gram-determinants are beyond a definite threshold and of nearly the same numerical value. Results for globally distributed observatories characterize the secular variation.

Webers, W.↗

Determination of the gram-positive bacterial content of soils and sediments by analysis of teichoic acid components

Many gram-positive bacteria form substituted polymers of glycerol and ribitol phosphate esters known as teichoic acids. Utilizing the relative specificity of cold concentrated hydrofluoric acid in the hydrolysis of polyphosphate esters it proved possible to quantitatively assay the teichoic acid-derived glycerol and ribitol from gram-positive bacteria added to various soils and sediments. The lipids are first removed from the soils or sediments with a one phase chloroform-methanol extraction and the lipid extracted residue is hydrolyzed with cold concentrated hydrofluoric acid. To achieve maximum recovery of the teichoic acid ribitol, a second acid hydrolysis of the aqueous extract is required. The glycerol and ribitol are then acetylated after neutralization and analyzed by capillary gas-liquid chromatography. This technique together with measures of the total phospholipid, the phospholipid fatty acid, the muramic acid and the hydroxy fatty acids of the lipopolysaccharide lipid A of the gram-negative bacteria makes it possible to describe the community structure environmental samples. The proportion of gram-positive bacteria measured as the teichoic acid glycerol and ribitol is higher in soils than in sediments and increases with depth in both.

Ribitol/analogs & derivatives↗

Comparison and Analysis of the Venus Global Reference Atmospheric Model

The goal of this research was to analyze the Venus Global Reference Atmospheric Model (Venus-GRAM) and determine how accurately the model is following its primary source data from the Venus International Reference Atmosphere (VIRA). A comparative analysis between Venus-GRAM and the Venus Climate Database (VCD) was also conducted. The VCD is an atmospheric model developed by the Laboratoire de Météorologie Dynamique (LMD) for both scientific and engineering purposes. The purpose of this work is to ensure the most up-to-date data is being used to prepare for future probe and aerocapture missions.

Libby Cutler↗

Finding diverse ways to improve algebraic connectivity through multi-start optimization

The algebraic connectivity, also known as the Fiedler value, is a spectral measure of network connectivity that can be increased through edge addition. We present an algorithm for producing many diverse ways to add a fixed number of edges to a network to achieve a near optimal Fiedler value. Previous Fielder value optimization algorithms (i.e. the greedy algorithm) output only one solution. Obtaining a single solution is rarely good enough for real-world network redesign problems, as practical constraints (political, physical or financial) may prevent implementation. Our algorithm takes a multi-start optimization approach, adding a random initial edge and then applies a greedy heuristic to improve the Fiedler value. The random choice moves us to a new region of the search space, enabling discovery of diverse solutions. Additionally, we present a Determinantal Point Process framework for quantifying diversity. We then apply a Markov chain Monte Carlo technique to sift through the large number of output solutions and locate a smaller, more manageable collection of highly diverse solutions that can be presented to network redesign engineers. We demonstrate the effectiveness of our algorithm on real-world graphs with varied structures.

97 MATHEMATICS AND COMPUTING↗

Fluid shifts during thermal stress with and without fluid replacement

Six unacclimatized men rested for 4 hr in a hot, dry environment without fluid replacement (DH). Another group of six men were exposed to the same thermal stress, replacing evaporative fluid loss with warm 0.1% NaCl solution (FRP). Total grams of circulating hemoglobin, determined by CO immediately prior to and again during the last minutes of heat exposure, increased an insignificant 1.6 and 1.3% during DH and FRP, respectively. With DH, body weight loss of 2.6% was accompanied by a 7.8% reduction in calculated plasma volume (PV). Even when body weight was maintained (FRP), PV decreased 2.9% during the heat exposure. Total circulating serum protein did not change as a result of the heat stress with either DH or FRP. In a test-retest series of experiments on four men, DH was not detrimental to sweat rate. It is shown that hemodilution is not a general response to acute heat exposure. The disproportionately large reduction in PV during thermal dehydration is confirmed.

Myhre, L. G.↗

Gravitational parameters of the Jupiter system from the Doppler tracking of Pioneer 10

Preliminary analyses of Doppler data from Pioneer 10 during its encounter with Jupiter indicate that the mass of Io is about 20% greater than previously thought and that Io's mean density is about 3.5 grams per cubic centimeter. A determination of the dynamical flattening of Jupiter (a - b)/a (where a is the semimajor axis and b is the semiminor axis) is found to lie in the neighborhood of 0.065, which agrees with the value determined from satellite perturbations.

Anderson, J. D.↗

The relative density of lunar soil

The specific gravity and minimum and maximum bulk densities were determined for three one-gram lunar soil samples containing particles less than 1 mm in diameter: 14163,148; 14259,3; and 15601,82. The specific gravity varied from 2.90 to 2.93 for the Apollo 14 samples to 3.24 for the Apollo 15 sample. The difference is attributed to the higher proportion of agglutinates and breccias and fewer mineral fragments and basalts in the Apollo 14 soils. The minimum bulk densities varied from 0.87 to 1.10 g/cu cm, while the maximum densities varied from 1.51 to 1.89 g/cu cm. The ranges in values were due to differences in the specific gravity, re-entrant intragranular voids, particle shape, surface texture, and grain arrangements. The in situ lunar soil in the plains areas of the moon can have a low to medium relative density at the surface, increasing rapidly to a very high relative density at depths greater than 10 to 20 cm.

Carrier, W. D., III↗

Survey and Experimental Testing of Nongravimetric Mass Measurement Devices

Documentation presented describes the design, testing, and evaluation of an accelerated gravimetric balance, a low mass air bearing oscillator of the spring-mass type, and a centrifugal device for liquid mass measurement. A direct mass readout method was developed to replace the oscillation period readout method which required manual calculations to determine mass. A protoype 25 gram capacity micro mass measurement device was developed and tested.

Oakey, W. E.↗

Mercury - Results on mass, radius, ionosphere, and atmosphere from Mariner 10 dual-frequency radio signals

Analysis of the radio-tracking data from Mariner 10 yields 6,023,600 plus or minus 600 for the ratio of the mass of the sun to that of Mercury, in very good agreement with values determined earlier from radar data alone. Occultation measurements yielded values for the radius of Mercury of 2440 plus or minus 2 and 2438 plus or minus 2 kilometers at latitudes of 2 N and 68 N, respectively, again in close agreement with the average equatorial radius of 2439 plus or minus 1 kilometers determined from radar data. The mean density of 5.44 grams per cubic centimeter deduced for Mercury from Mariner 10 data thus virtually coincides with the prior determination. No evidence of either an ionosphere or an atmosphere was found.

Esposito, P. B.↗

Design and validation of a gamma-ray scanning system for measuring irradiated nuclear fuel

We report a prototype gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. This paper documents the design process, modeling and the laboratory characterization performed to validate the system. The modeling of the system was done using the Monte Carlo N-Particle code with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector. The characterization included measurements of calibrated radiation sources in different geometries, and calculations for absolute efficiency and dead time. Benchmark measurements were performed scanning an irradiated fuel rodlet containing ten pellets of 4.9% enriched UO2 in zirconium alloy. These results were compared to simulated spectra to further help characterize the detector model. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel; comparison of the results from this prototype system's assay of the irradiated fuel rodlet are in agreement with previously estimated results.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Helium bubble formation in aged plutonium metal at ambient conditions

A model of helium bubble formation is developed that assumes the initial nascent bubbles are generated when two diffusing helium atoms come within a distance of about the interatomic spacing of the plutonium atoms. These nascent bubbles are assumed to be locked in place and grow as additional helium atoms diffuse across their surfaces. Calculations of the helium-bubble number density and sizes as a function of age are compared to experiment. This leads to an inferred helium diffusion coefficient of-the-order of 10 -20 m 2 /s, supports the idea that most of the helium from alpha-decay end up in bubbles, and that previous transmission electron microscopy size estimates are biased low. The energy that helium can transfer to 40-year-old plutonium, upon expansion, is determined to be <0.1 Joules per gram of metal. The model predicts differences between the bubble properties in naturally and accelerated aged plutonium.

36 MATERIALS SCIENCE↗

Comparing the Earth Impact Flux from Comets and Near-Earth Asteroids

Long-period comets (LPC), defined here as those active comets with orbital periods greater than 200 years, are the most difficult objects to mitigate should one be found on an Earth threatening trajectory. The arrival of these objects from the distant Oort cloud cannot be predicted and the impact warning time would be measured in a few months - not years. At the distance of Jupiter, an inactive cometary nucleus with a diameter of one kilometer and a geometric albedo equal to 0.04 would have an apparent magnitude fainter than 25 near opposition and, hence would be well outside the detection capability of current NEO search telescopes. In general LPCs do not become active, and hence discoverable, until inside the orbit of Jupiter and it takes but nine months for a LPC to travel the distance from Jupiter's orbit to that of the Earth.Estimating the impact energy for long-period comets is particularly difficult because the sizes and masses of these objects are not well known. Their solid nuclei are hidden from ground-based telescopes by their gas and dust atmospheres and even when nearby spacecraft observations can determine a size and shape for a cometary nucleus, there are no direct determinations of any cometary mass or bulk density to date. However, a variety of indirect bulk density determinations consistently provide values below one gram per cubic centimeter, the value for water. From measurements made by the Deep Impact spacecraft during its encounter with comet Tempel 1 in July 2005, the bulk density was estimated to be 0.6 grams per cubic centimeter. The mean impact velocity of a LPC is about 51 km/s, three times the 17 km/s value for a typical near-Earth asteroid (NEA) so the impact energy for an LPC would be 9 times that of a NEA of similar mass. However, the bulk density of a comet (approx. 0.6 g/cu cm) is several times less than the density of a stony NEA (approx. 2.6 g/ cu cm) so for a LPC and a stony NEA of the same size, the LPC's impact energy would be about twice that of the NEA.To properly allocate the limited resources available for NEO surveys and physical characterization, it is important to understand the relative threat from long-period comets versus the threat posed by near-Earth asteroids.

near Earth objects↗

Design and Validation of a Gammaray Scanning System for Measuring Irradiated Nuclear Fuel

A prototype gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. This paper documents the design process, modeling and the laboratory characterization performed to validate the system. The modeling of the system was done using the Monte Carlo N-Particle code with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector. The characterization included measurements of calibrated radiation sources in different geometries, and calculations for absolute efficiency and dead time. Benchmark measurements were performed by scanning an irradiated fuel rodlet containing ten pellets of 4.9% enriched UO2 in zirconium alloy. These results were compared to simulated spectra to further help characterize the detector model. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel; comparison of the results from this prototype system's assay of the irradiated fuel rodlet are in agreement with previously estimated results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Irradiated Low-Enriched Uranium Fuel Measurements with a Gamma-Ray Scanning System

A gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. A Monte Carlo N-Particle code simulation of the system and the fuel were created with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector as well as all available fuel specifications. Benchmark measurements were performed by scanning an irradiated fuel rodlet containing eight pellets of 0.74% enriched UO2 in zirconium alloy. This fuel rodlet was part of the Static Environment Rodlet Transient Test Apparatus (SERTTA) testing campaign in the Transient Reactor Test Facility (TREAT). These results were compared to simulated spectra to help characterize the detector model and establish fidelity. A goal of the system is to determine the number of fissions per gram of UO2 in the fuel. This paper documents the modeling of the system and the calculation of the number of fissions per gram along the axial length of the SERTTA-C rodlet.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DESIGN AND VALIDATION OF A GAMMA-RAY SCANNING SYSTEM FOR MEASURING IRRADIATED NUCLEAR FUEL (ABSTRACT)

A prototype gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. This paper documents the design process, modeling and the laboratory characterization performed to validate the system. The modeling of the system was done using the Monte Carlo N-Particle code with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector. The characterization included measurements of calibrated radiation sources in different geometries, and calculations for absolute efficiency and dead time. Benchmark measurements were performed by scanning an irradiated fuel rodlet containing ten pellets of 4.9% enriched UO2 in zirconium alloy. These results were compared to simulated spectra to further help characterize the detector model. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel; comparison of the results from this prototype system's assay of the irradiated fuel rodlet are in agreement with previously estimated results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of Irradiated Low Enriched Fuel with a Gamma-Ray Scanning System (ANIMMA 2023 Conference Presentation)

A gamma-ray scanning system was designed to perform post-irradiation measurements of nuclear fuel at Idaho National Laboratory (INL). The system is composed of a coaxial high-purity germanium (HPGe) detector, a collimator, and mechanical positioning stages that translate the fuel sample across the front of the collimator. A Monte Carlo N-Particle code simulation of the system and the fuel were created with vendor-supplied design specifications, dimensional measurements, and x-ray radiographs of the HPGe detector as well as all available fuel specifications. Benchmark measurements were performed by scanning an irradiated fuel rodlet containing eight pellets of 0.74% enriched UO2 in zirconium alloy. This fuel rodlet was part of the Environment Rodlet Transient Test Apparatus (SERTTA) testing campaign in the Transient Reactor Test Facility (TREAT). These results were compared to simulated spectra to help characterize the detector model and establish fidelity. One goal of the system is to determine the number of fissions per gram of UO2 in the fuel. This article documents the modeling, benchmarking measurements, and the calculated number of fissions per gram in the SERTTA-A rodlet which was previously irradiated at TREAT.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗