Search NASA⌕ Search

SEARCH · Search NASA

Results for “Graphite Analytical Tool”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Status on Development of Graphite Analytical Tool (GAT)

The DOE-ART Graphite R&D program has been generating significant amounts of irradiated and unirradiated graphite data since 2006 when the program was part of the DOE NGNP (Next Generation Nuclear Plant) Project. This data includes critical irradiation creep and irradiated material property changes from the Advanced Graphite Creep (AGR) experiment as well as significant amounts of data on unirradiated material property values on several current nuclear graphite grades (Baseline program). Previously, Idaho National Laboratory has developed an internal analysis tool to assist with analysis of the unirradiated and irradiated data. The Graphite Analytical Tool (GAT) is intended to provide easy access to the graphite data in the form of comparing unirradiated and irradiated material property changes, comparison of material property differences between various nuclear graphite grades, and illustrate trends within the irradiated and unirradiated data generated within the DOE-ART Graphite R&D program. This report summarizes the progress to-date on the development of this analytical tool.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

HiMAT structural development design methodology

In order to improve aerodynamic performance, a twist criterion was used to design the canard and wing lifting surfaces of two graphite-epoxy research aircraft. To meet that twist criterion, the lifting surfaces were tailored using graphite-epoxy tape. The outer surface of the aircraft is essentially constructed of 95 percent graphite epoxy materials. The analytical tools and methodology used to design those lifting surfaces are described. One aircraft was subjected to an 8g ground test in order to verify structural integrity and to determine how well the desired twist was achieved. Test results are presented and the reductions of both flight and ground strain test gages and their associated stresses are discussed.

Price, M. A.↗

Molecular modeling of interactions in electronic nose sensors for environmental monitoring

We report a study aimed at understanding analyte interactions with sensors made from polymer-carbon black composite films. The sensors are used in an Electronic Nose (ENose) which is used for monitoring the breathing air quality in human habitats. The model mimics the experimental conditions of the composite film deposition and formation and was developed using molecular modeling and simulation tools. The Dreiding 2.21 Force Field was used for the polymer and analyte molecules while graphite parameters were assigned to the carbon black atoms. The polymer considered for this work is methyl vinyl ether / maleic acid copolymer. The target analytes include both inorganic (NH3) and organic (methanol) types of compound. Results indicate different composite-analyte interaction behavior.

electronic noise polymer-carbon composite molecula↗

Direct and Sensitive Electrochemical Evaluation of Pramipexole Using Graphitic Carbon Nitride (gCN) Sensor

Pramipexole (PMXL) belongs to the benzothiazole class of aromatic compounds and is used in treating Parkinson’s disease; however, overdosage leads to some abnormal effects that could trigger severe side effects. Therefore, it demands a sensitive analytical tool for trace level detection. In this work, we successfully developed an electrochemical sensor for the trace level detection of PMXL, using the voltammetric method. For the analysis, graphitic carbon nitride (gCN) was opted and synthesized by using a high-temperature thermal condensation method. The synthesized nanoparticles were employed for surface characterization, using transmission electron microscopy (TEM), X-ray diffraction (XRD), and atomic force microscopy (AFM) techniques. The electrochemical characterization of the material was evaluated by using the electrochemical impedance spectroscopy (EIS) technique to evaluate the solution–electrode interface property. The cyclic voltammetry (CV) behavior of PMXL displayed an anodic peak in the forward scan, indicating that PMXL underwent electrooxidation, and an enhanced detection peak with lower detection potential was achieved for gCN-modified carbon paste electrode (gCN·CPE). The influence of different parameters on the electrochemical behavior was analyzed, revealing the diffusion governing the electrode process with an equal number of hydronium ions and electron involvement. For the fabricated gCN·CPE, good linearity range was noticed from 0.05 to 500 µM, and a lower detection limit (L D ) of 0.012 µM was achieved for the selected concentration range (0.5 to 30 µM). Selectivity of the electrode in PMXL detection was investigated by conducting an interference study, while the tablet sample analysis demonstrates the sensitive and real-time application of the electrode. The good recovery values for the analysis illustrate the efficiency of the electrode for PMXL analysis.

36 MATERIALS SCIENCE↗

Analyses at High Spatial Resolution of Organic Molecules in Extraterrestrial Samples: Two-Step Laser Mass Spectrometry: Search for Polycyclic Aromatic Hydrocarbons in Antarctic Meteorite and Micrometeorite Samples

Perhaps the best way to summarize the past three-year grant period is to cite the publications and present a brief synopsis of each: 1. "Indigenous Polycyclic Aromatic Hydrocarbon Molecules in Circumstellar Graphite Grains." Bulk C-12/C-13 isotope ratios observed in some graphite grains extracted from primitive meteorites point strongly to a circumstellar origin. By applying our technique of microprobe two-step laser desorption laser ionization mass spectrometry ((mu)L(sup 2)MS) to individual circumstellar graphite grains we have measured the C-12/C-13 isotope ratio of various polycyclic aromatic hydrocarbons (PAHS) found in these grains. 2. "Deuterium Enrichments in Cluster IDPS," Large enrichments in the D/H isotope ratios in IDPs likely arise from the preservation of presolar molecules. 3. "Evidence for thermalization of surface-disorder molecules at heating rates of 10(exp 8) K/s". A careful study of the ((mu)L(sup 2)MS) of aniline-d(sub 7) from a single-crystal surface (0001) of sapphire (al2O3) shows that all measured properties are consistent with a thermal mechanism for desorption. 4. "Search for past life on Mars; possible relic biogenic activity in Martian meteorite ALH 84001. The authors examined the Martian meteorite ALH 84001 and found several lines of evidence compatible with existence of past primitive (single-cell) life on early Mars. 5. "Microprobe two-step laser mass spectrometry as an analytical tool for meteorite samples". THis paper presents a comprehensive review of (mu)L(sup 2)MS and how this technique can be applied to meteoritic samples. 6. "Indigenous polycyclic aromatic hydrocarbons in circumstellar graphite grains from primitive meteorites". The C-12/C-13 isotope ratios were measured for PAHs in a total of 89 spherical graphite grains. 7. "Observation of indigenous polycyclic aromatic hydrocarbons in "Giant" carbonaceous antarctic micrometeorites." The (mu)L(sup 2)MS method was used to establish the nature and distribution of PAHs in fragments of fifteen (approx. 200 microns) carbonaceous antarctic micrometeorites (AMMs). 8. "Evidence for the extraterrestrial origin of polycyclic aromatic hydrocarbons in the Martian meteorite ALH 84001" We have undertaken additional contamination studies of ALH 84001.

Zare, Richard N.↗

Analytical and experimental studies of graphite-epoxy and boron-epoxy angle ply laminates in shear

The results of a comparison study between a test program on the inelastic response under inplane shear over a wide range of graphite-epoxy and boron-epoxy angle-ply laminates are reported. This investigation was aimed at evaluating the applicability and adequacy of these analyses to predict satisfactorily the responses of angle-ply laminates. It was observed that these analytical tools are inadequate for this purpose as they fail to predict with sufficient confidence the shape of response and in particular the strength values associated with a given laminate configuration. Consequently, they do not provide the sought-after information about failure mechanisms which trigger failure of a particular designed laminate.

Weller, T.↗

Stability analysis of Centaur-in-Shuttle composite corrugated adapters

This paper evaluates analytically the structural integrity of discretely-loaded, graphite-epoxy, corrugated adapters for the Centaur-in-Shuttle, where combined compression and shear are the critical loads involved. With normal build-ups in the thickness at load introduction boundaries, the structural integrity for both compression and shear buckling was little (or not al all) affected by the discrete load introductions. The analytical tool employed was the STAGSC computer code, and both bifurction buckling and nonlinear collapse options were used; the latter option was limited to shear since postbuckling strength in compression for plate-type structures is governed by crippling strengths, which is not attainable by existing computer codes.

Spier, E. E.↗

Application of Raman Spectroscopy for Nondestructive Evaluation of Composite Materials

This paper will present an overview of efforts to investigate the application of Raman spectroscopy for the characterization of Kevlar materials. Raman spectroscopy is a laser technique that is sensitive to molecular interactions in materials such as Kevlar, graphite and carbon used in composite materials. The overall goal of this research reported here is to evaluate Raman spectroscopy as a potential nondestructive evaluation (NDE) tool for the detection of stress rupture in Kevlar composite over-wrapped pressure vessels (COPVs). Characterization of the Raman spectra of Kevlar yarn and strands will be presented and compared with analytical models provided in the literature. Results of testing to investigate the effects of creep and high-temperature aging on the Raman spectra will be presented.

Washer, Glenn A.↗

Hollow-core optical fibre sensors for operando Raman spectroscopy investigation of Li-ion battery liquid electrolytes

Improved analytical tools are urgently required to identify degradation and failure mechanisms in Li-ion batteries. However, understanding and ultimately avoiding these detrimental mechanisms requires continuous tracking of complex electrochemical processes in different battery components. Here, we report an operando spectroscopy method that enables monitoring the chemistry of a carbonate-based liquid electrolyte during electrochemical cycling in Li-ion batteries with a graphite anode and a LiNi 0.8 Mn 0.1 Co 0.1 O 2 cathode. By embedding a hollow-core optical fibre probe inside a lab-scale pouch cell, we demonstrate the effective evolution of the liquid electrolyte species by background-free Raman spectroscopy. The analysis of the spectroscopy measurements reveals changes in the ratio of carbonate solvents and electrolyte additives as a function of the cell voltage and show the potential to track the lithium-ion solvation dynamics. The proposed operando methodology contributes to understanding better the current Li-ion battery limitations and paves the way for studies of the degradation mechanisms in different electrochemical energy storage systems.

47 OTHER INSTRUMENTATION↗

Ethylene Carbonate–Free Electrolytes for Stable, Safer High–Nickel Lithium–Ion Batteries

Ethylene carbonate (EC) is an important component in state-of-the-art electrolytes for lithium-ion batteries (LIBs). However, EC is highly susceptible to oxidation on the surface of high-nickel layered oxide cathodes, making it undesirable for next-generation high-energy-density LIBs. In this study, a simple, yet effective, EC-free electrolyte (20F1.5M-1TDI) is presented by adding 20 wt% fluoroethylene carbonate (FEC) and 1 wt% lithium 4,5-dicyano-2-(trifluoromethyl)imidazole (LiTDI) into 1.5 M LiPF 6 in an ethyl methyl carbonate (EMC) electrolyte. The 20F1.5M-1TDI electrolyte is found to efficiently passivate the graphite anode and stabilize high-nickel cathodes by a synergistic decomposition of FEC and LiTDI. The LiNi 0.9 Mn 0.05 Al 0.05 O 2 (NMA90)/graphite full cell with the 20F1.5M-1TDI electrolyte, therefore, exhibits an enhanced cycling stability and a suppressed voltage hysteresis growth compared to that with an EC-containing baseline electrolyte (1 M LiPF 6 in EC:EMC, 3:7 in weight, with 2 wt% vinyl carbonate). Advanced analytical tools, such as time-of-flight secondary ion mass spectrometry and X-ray photoelectron spectroscopy, are employed to understand the underlying working mechanism of the EC-free electrolyte. Furthermore, the present study clearly showcases the great potential of EC-free electrolytes as a straightforward, practical approach for LIBs with high-nickel cathodes.

electrode/electrolyte interface↗

Nonlinear response of a blade-stiffened graphite-epoxy panel with a discontinuous stiffener: Work in progress

The problem of calculating detailed stress distributions around discontinuities in buckled, composite structural components for use with the various analytical failure prediction techniques has not been thoroughly explored. The purpose here is the application of computational methods to the detailed stress analysis problem which is the focus of this session of the workshop. One approach to uncovering the difficulties of this type of analysis and to providing specific directions for future research in this area is a direct attack on the problem using currently available analysis tools. A candidate problem has been selected and experiences from calculating its structural response are described.

Knight, Norman F., Jr.↗

Verification and application of the Iosipescu shear test method

Finite element models were used to study the effects of notch angle variations on the stress state within an Iosipescu shear test speciment. These analytical results were also studied to determine the feasibility of using strain gage rosettes and a modified extensometer to measure shear strains in this test specimen. Analytical results indicate that notch angle variations produced only small differences in simulated shear properties. Both strain gage rosettes and the modified extensometer were shown to be feasible shear strain transducers for the test method. The Iosipoescu shear test fixture was redesigned to incorporate several improvements. These improvements include accommodation of a 50 percent larger specimen for easier measurement of shear train, a clamping mechanism to relax strict tolerances on specimen width, and a self contained alignment tool for use during specimen installation. A set of in-plane and interlaminar shear properties were measured for three graphite fabric/epoxy composites of T300/934 composite material. The three weave patterns were Oxford, 5-harness satin, and 8-harness satin.

Walrath, D. E.↗

Application of surface analysis to solve problems of wear

Results are presented for the use of surface analytical tools including field ion microscopy, Auger emission spectroscopy analysis (AES), cylindrical mirror Auger analysis and X-ray photoelectron spectroscopy (XPS). Data from the field ion microscope reveal adhesive transfer (wear) at the atomic level with the formation of surface compounds not found in the bulk, and AES reveals that this transfer will occur even in the presence of surface oxides. Both AES and XPS reveal that in abrasive wear with silicon carbide and diamond contacting the transition metals, the surface and the abrasive undergo a chemical or structural change which effects wear. With silicon carbide, silicon volatilizes leaving behind a pseudo-graphitic surface and the surface of diamond is observed to graphitize.

Buckley, D. H.↗

Fluctuation cepstral scanning transmission electron microscopy of mixed-phase amorphous materials

Four-dimensional scanning transmission electron microscopy (4D-STEM) is a versatile analytical tool for characterizing materials structural properties. However, extending such analysis to disordered materials is challenging, especially in technologically important samples with mixed ordered and disordered phases. Here, in this work, we present a new 4D-STEM method, called fluctuation cepstral STEM (FC-STEM), based on the fluctuation analysis of cepstral transform of diffraction patterns. The peaks in the associated transformation relate to inter-atomic distances in a thin sample. By varying the real-space range over which fluctuations are calculated, distinct ordered and disordered phases can be mapped in a diffractive image reconstruction. We demonstrate the principles of FC-STEM by characterizing a silicon anode, harvested from a cycled lithium-ion battery. A mixture of amorphous and nanocrystalline silicon, graphitic carbon, and electrolyte by-products is identified and mapped. Comparisons with conventional electron imaging and energy-dispersive X-ray spectroscopy show that FC-STEM is highly effective for the structure determination of mixed-phase amorphous materials.

36 MATERIALS SCIENCE↗

Advancing neutron diffraction for accurate structural measurement of light elements at megabar pressures

Over the last 60 years, the diamond anvil cell (DAC) has emerged as the tool of choice in high pressure science because materials can be studied at megabar pressures using X-ray and spectroscopic probes. In contrast, the pressure range for neutron diffraction has been limited due to low neutron flux even at the strongest sources and the resulting large sample sizes. Here, we introduce a neutron DAC that enables break-out of the previously limited pressure range. Key elements are ball-bearing guides for improved mechanical stability, gem-quality synthetic diamonds with novel anvil support and improved in-seat collimation. We demonstrate a pressure record of 1.15 Mbar and crystallographic analysis at 1 Mbar on the example of nickel. Additionally, insights into the phase behavior of graphite to 0.5 Mbar are described. These technical and analytical developments will further allow structural studies on low-Z materials that are difficult to characterize by X-rays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Methods—Design Guidelines for Tubular Flow-through Electrodes for Use in Electroanalytical Studies of Redox Reaction Kinetics

The tubular flow-through electrode (FTE) is a facile electroanalytical tool for investigating electrochemical reaction kinetics; however, its suitability for this purpose requires careful design and operation under conditions that guarantee uniform current distribution. In this perspective article, we provide a scaling analysis of the transport and reaction processes within a tubular FTE leading to quantitative guidelines for the FTE design and operation. Two dimensionless parameters (classical Wagner number Wa I and modified Wagner number incorporating the effect of mass transport Wa II ) are utilized to compare the magnitudes of the ohmic, activation and transport resistances of the tubular FTE, and to quantify its current distribution uniformity. With the aid of analytical modeling of the current distribution, optimal ranges for these two dimensionless parameters are defined so as to ascertain uniform current distribution. Application of these guidelines to a graphite tubular FTE is shown to enable the precise determination of the charge-transfer kinetics of the ferri/ferrocyanide redox reaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microbial potentiometric sensor technology for real-time detecting and monitoring of toxic metals in aquatic matrices

Considering that toxic metals can affect metabolic processes in microorganisms adversely, it can be hypothesized that these metals in water matrices would induce a decrease in metabolic activity of the biofilm microorganisms populating the surface of a sensing electrode, which could be registered as a change in the open-circuit potential (OCP) generated by the biofilm microorganisms. The goal of this study was to test this hypothesis and demonstrate the underlying principle that microbial potentiometric sensor (MPS) technology could be used for long-term and real-time monitoring and detection of rapid changes in metal concentrations in realistic aquatic environments. To address the goal, four objective were addressed: (1) a batch reactor with three graphite-based MPS electrodes was fabricated; (2) a set of single-ion solutions and one multiple ion solution were prepared reflecting realistic concentrations of metals found in electroplating wastewaters; (3) the responses of the MPS to the simultaneous presence of multiple toxic metal ions in a single solution were measured; and (4) the changes of the MPS signals to the presence of individual metal ion solutions were examined. While the hypothesis was validated, the study also revealed that the MPS was sufficiently sensitive to not only detect, but also quantify, toxic metal ion concentrations in aqueous solutions. The coefficients of determination, which were R 2 > 0.995, and responsiveness of <1 μmol/L for some toxic metal cations, strongly support the performance of MPS technology in the echelons of expensive analytical tools capable detecting and measuring trace elements.The magnitude of the MPS response was toxic metal specific. When the molar concertation normalizes the inhibition portion of the signal area, the assessed sensitivity order was: Se>Cd>Pb>Ag>Ni> Zn. The study provides valuable information for enforcement agents, environmental professionals, and wastewater treatment operators, so toxic metal pollution and its detrimental impacts can be prevented and mitigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A “Master Curve” Describing Reaction Inhomogeneity and Plating Onset during Fast-Charging of Graphite Electrodes

Lithium plating in porous graphite electrodes is a major limitation for fast charging. Theoretical evidence suggests plating during fast charging is largely due to inhomogeneous intercalation through the electrode thickness (caused by ionic/mass transfer limitations and inherent thermodynamic properties of the graphite material). Numerical and analytical predictions of plating onset during fast charging have been proposed but not compared directly with experiments. This work validates these model predictions against plating onset measurements via the “dOCV” method in graphite half-cells, for various electrode thicknesses and C-rates. Remarkably, it is shown that experimental and theoretical trends in plating onset (vs C-rate and electrode thickness) collapse to a single “master curve” using a nondimensional “reaction inhomogeneity” parameter. This observation supports the hypothesized reaction inhomogeneity mechanism for accelerating plating onset and provides practical guidance for electrode design. Furthermore, this work develops theory to quantify reaction inhomogeneity in situ directly from voltage V vs capacity Q data, using dQ / dV analysis. Here again, experiments and numerical predictions show good agreement, where peaks that correspond to LiC 6 correlate with plating onset. This work provides experimental validation of theoretical tools that can predict plating onset, aid electrode design, and give insight for plating onset mechanisms during fast charging.

25 ENERGY STORAGE↗