Search NASA⌕ Search

SEARCH · Search NASA

Results for “Grid Connection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Connected Loads – Grid Connected Appliances: Commercial Refrigeration System Fault Detection and Diagnostics

As one of the most energy-intensive end-uses in the commercial buildings sector, supermarkets consume around 50 kWh/ft 2 (or 537.6 kWh/m 2 ) of electricity annually, or more than 2 million kWh of electricity per year for a typical store. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40–60% of its total electricity usage and is equivalent to about 2–3% of the total energy consumed by commercial buildings in United States, or around 0.5 quadrillion Btu (or 0.53 quadrillion KJ). Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Current supermarket refrigeration systems rely on high global warming potential hydrofluorocarbon refrigerants. Reducing refrigerant usage or using environment friendly alternatives can result in significant climate benefits. Transcritical CO2 refrigeration systems have attracted more attention in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in commercial buildings such as supermarkets. The refrigeration system can also be adapted to handle flexible building loads and be integrated into grid response transactive control to balance the supply and demand of the electric grid. Even minor improvements in the efficiency and operational reliability of supermarket refrigeration systems can create significant value in terms of saving energy, improving food quality, protecting the environment, reducing carbon footprint, and enhancing electric grid resilience.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Connected Loads – Grid Connected Appliances: Deployment IoT Solution for Fault Detection and Diagnostics

As one of the most energy-intensive end-uses in the commercial buildings sector, supermarkets consume around 50 kWh/ft 2 ( or 537.6 kWh/m 2 ) of electricity annually, or more than 2 million kWh of electricity per year for a typical store. The biggest consumer of energy in a supermarket is its refrigeration system, which accounts for 40–60% of its total electricity usage and is equivalent to about 2–3% of the total energy consumed by commercial buildings in United States, or around 0.5 quadrillion Btu (or 0.53 quadrillion KJ). Also, the supermarket refrigeration system is one of the biggest consumers of refrigerants. Current supermarket refrigeration systems rely on high global warming potential hydrofluorocarbon refrigerants. Reducing refrigerant usage or using environment friendly alternatives can result in significant climate benefits. Transcritical CO2 refrigeration systems have attracted more attention in recent years because of their zero-carbon emission advantages compared with traditional refrigerants. These systems are widely used in commercial buildings such as supermarkets. The refrigeration system can also be adapted to handle flexible building loads and be integrated into grid response transactive control to balance the supply and demand of the electric grid. Even minor improvements in the efficiency and operational reliability of supermarket refrigeration systems can create significant value in terms of saving energy, improving food quality, protecting the environment, reducing carbon footprint, and enhancing electric grid resilience. For decarbonization, the new administration has set a target to reduce greenhouse gas emissions by 50– 52% by 2030 and targeting a carbon-neutral economy by 2050. For electrification, the goal is to achieve 100% clean electricity by 2035. Such decarbonization and electrification in the building sector require that energy consumption in buildings be reduced significantly. Therefore, the building sector must continuously adopt new technologies to achieve its energy and carbon emission goals. One of the most fundamental technologies is the Internet of Things (IoT). IoT has proven to be an effective solution for the building domain, including building information/energy modeling, smart buildings, etc. Although much progress has been made in the development of IoT-based building energy systems, there is still a lack of reliable, scalable, and affordable IoT-based automated fault and degradation diagnostics (AFDDs) solutions. Such solutions would enable deployment of advanced algorithms into real systems to archive the projected energy benefits. This study reviews existing IoT solutions developed for building energy– related application and developed a simple but effective AFDD IoT deployment solution, including developing a suitable IoT architecture and conducting easy and scalable deployment by leveraging a common cloud-based IoT service.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An Inrush Current Limiting Method for Grid-Connected Converters Considering Grid Voltage Disturbances

To support the electric power grid, some grid-connected converters are required to ride through abnormal grid conditions, including voltage disturbances. However, at the moment, when a grid voltage disturbance happens, a large inrush current could be induced due to the large difference between the grid and converter output pulsewidth modulation (PWM) voltages. This inrush current could be more severe in the faster switching SiC-based multilevel converter, which only needs a small filter inductance to meet its normal operation requirements, such as harmonics and peak ripple currents. In this article, a PWM mask method is used to limit the inrush current. With this method, the inrush current can be effectively limited to a preset value and can help the converter ride through grid voltage disturbances. Furthermore, the method is validated through experiments conducted on a single-phase SiC-based five-level converter considering low voltage, high voltage, and phase angle disturbances.

42 ENGINEERING↗

Development of Application Function Blocks for Power-Hardware-in-the-Loop Testing of Grid-Connected Inverters: Preprint

Stability and accuracy of the PHIL platform has been a common problem and challenging issue for a long time, thus continuous efforts and research have been devoted to developing interface algorithms to improve upon this. Some of existing works exhibit promising solutions to compensate the errors in the PHIL platform. However, there is a need to harmonize various solutions into a standard framework that provides a general solution for various PHIL test beds and that can be reused with minimum modifications to avoid extra effort. A good way to do this is by using application function blocks (AFBs), which are model-based and can be developed as a standard library component, thus achieving satisfactory reusability and reconfigurability for various platforms. Since PHIL simulation has the flexibility of the software simulation, proper functions can be easily implemented in the digital real-time simulator (DRTS) to preprocess the reference signal before sending it to the power amplifier. Therefore, this paper aims to develop standard AFBs in DRTS for the PHIL interface to test grid-connected inverters. The PHIL interface algorithm is separated into five AFBs that will be presented in detail in this paper.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Life Prediction Model for Grid-Connected Li-ion Battery Energy Storage System

Lithium-ion (Li-ion) batteries are being deployed on the electrical grid for a variety of purposes, such as to smooth fluctuations in solar renewable power generation. The lifetime of these batteries will vary depending on their thermal environment and how they are charged and discharged. To optimal utilization of a battery over its lifetime requires characterization of its performance degradation under different storage and cycling conditions. Aging tests were conducted on commercial graphite/nickel-manganese-cobalt (NMC) Li-ion cells. A general lifetime prognostic model framework is applied to model changes in capacity and resistance as the battery degrades. Across 9 aging test conditions from 0oC to 55oC, the model predicts capacity fade with 1.4% RMS error and resistance growth with 15% RMS error. The model, recast in state variable form with 8 states representing separate fade mechanisms, is used to extrapolate lifetime for example applications of the energy storage system integrated with renewable photovoltaic (PV) power generation.

25 ENERGY STORAGE↗

Hierarchical Control of Grid-Connected Hydrogen Electrolyzer Providing Grid Services

This paper presents the operational modes and control architecture of the grid-connected hydrogen electrolyzer systems for the provision of frequency and voltage supports. The analysis is focused on the primary and secondary loops in the hierarchical control scheme. At the power converter inner control loop, the voltage- and current-control modes are analyzed. At the primary level, the droop and opposite droop control strategies to provide voltage and frequency support are described. Coordination between primary control and secondary, tertiary reserves is briefly discussed. The case studies and real-time hardware-in-the-loop simulation results are provided using Typhoon HIL to back the theoretical investigation.

ancillary services↗

Control of Grid-Connected Multiport MV Power Electronics Energy Hub: Preprint

In this paper a new concept of multiport modular medium-voltage power electronics hub (M3PE-HUB) is introduced for future power grid. The goal for this project is to design, develop, and demonstrate foundational technologies and capabilities for multiport power electronics energy hubs that can serve as intelligent devices to coordinate and control several different sources and loads. In this paper, the architecture of the controller, the central controls, and its verification is presented.

controls↗

Temporal Convolutional Network Using Empirical Mode Decomposition to Detect Faults in Grid Connected Systems

Grid-connected power electronic systems require timely and reliable fault detection to prevent equipment damage and reduce downtime. This paper presents a forecasting-based anomaly detection pipeline that decomposes voltage and current measurements into intrinsic mode functions (IMFs) using empirical mode decomposition (EMD), then trains a causal temporal convolutional network (TCN) on normal-operation IMF data to predict short-horizon future dynamics. Deviations between forecasts and observations are summarized as reliability-weighted residual scores and thresholded per sensor using robust statistics with temporal persistence constraints to suppress false positives. To reduce runtime, EMD is performed on downsampled signals for detection, while raw-rate EMD is applied only within a short region of interest for high-frequency interpretability near detected events. Results on a simulated grid-connected converter system demonstrate that IMF-domain forecasting improves anomaly separability relative to raw-signal forecasting and provides interpretable evidence of faults across decomposition channels.

Sutton, Elizabeth [ORNL] (ORCID:0009000078885935)↗

Development and Validation of a SiC Based 50 kW Grid-Connected PV Inverter: Preprint

In this digest a 50kW string PV inverter formed using all SiC semiconductor devices is presented. The inverter design includes additively manufactured power block, symmetrical Y-core inductors for ac side filter, and advanced inverter functionality for grid support. This inverter utilizes the conventional three-phase Voltage Source Inverter topology and optimizes the design for SiC based devices. This paper presents the full functional validation of the designed inverter along with quantification of the efficiency and power density. The performance of the inverter for high dc-bus voltage without multi-level topology to exploit SiC advantages is also presented in this digest. The full paper will include details of inverter design, optimization and further experimental validation.

14 SOLAR ENERGY↗

Modeling and Feedback Compensator Design for Power-Hardware-in-the-Loop System for Medium-Voltage Grid-Connected Power Converters

Hardware-in-the-loop (HIL) evaluation is a method in which the test subject is split into a physical part and a simulated part, and these parts are connected with interfaces to form a combined physical-numerical system. Power-hardware-in-the-loop (PHIL) systems, where actual hardware is connected to a real-time model, can exhibit issues of instability, inaccuracy and errors when operating in a closed-loop. The challenges of generating a PHIL setup are that, first, because of the limited dynamic response of the different parts of the system, the test results might be inaccurate, and, second, because of the high frequency noise introduced by the sensors to the closed-loop system, it can be difficult to design a compensator for the real-time emulator response, while stabilizing the closed-loop system at the same time. In this paper, different parts of a PHIL system are characterized, and the feedback compensator system design is proposed for the stable operation of the closed-loop PHIL system. The issues as observed in a PHIL system without any compensator are demonstrated using experimental results, and the effectiveness of a first order phase lead compensator is validated.

compensator design↗

The Impact of Transformer Winding Connections of A Grid-Connected PV on Voltage Quality Improvement

In this paper, the high-power PV plant is connected to the weak grid by means of a three-phase power transformer. The selection of transformer winding connection is critical especially when the PV inverter has a reactive power controller. In general, transformer winding connection can be arranged in star-star (with neutral earthed) or star-delta. The reactive power controller supports voltage regulation of the power system particularly under transient faults. Its control strategy is based on utilizing the grid currents to make a three-phase reactive unbalanced current with a small gain. The gain is determined by the system impedance. Simulation results exhibit that the control strategy works very well particularly under disturbance conditions when the transformer winding connection is star-star with both neutrals grounded. The power quality in terms of the voltage quality is improved.

14 SOLAR ENERGY↗

Cyber Protection of Grid-Connected Devices Through Embedded Online Security

Cybersecurity research regarding the electric power grid has primarily been focused on protecting the communication layer of grid-connected devices against cyber-attack threats. Although many developed methods have greatly reduced the effects of a cyber-attack on the vulnerabilities of grid-connected devices, discovering new vulnerabilities is inevitable and a constant threat. As a result, the overall reliability and security of network communications with regard to grid-connected devices is a concern. Here, this paper proposes a method that further secures a system by focusing on the control and hardware layer of grid-connected devices. The device’s controller firmware will be validated and authenticated using integrated device emulation resources prior to being activated to control the grid-connected device. This verification process is performed while the controller is online and actively controlling power flows related to the device. Therefore, an attack to the system through a malicious firmware patch would be detected by the online security and rejected while safely maintaining continuous and stable control of the device. This method integrates the concepts of firmware hot-patching, digital twins, and active monitoring into an overall cybersecurity protection system.

cybersecurity↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode: Preprint

This paper explores the dispatch-ability of grid-forming (GFM) inverters in grid-connected and islanded mode. Grid-forming (GFM) inverters usually use droop control to automatically share power with other GFM sources (inverters and synchronous generator (SG)) and follow the change of the load demand. However, they can be dispatched like their grid-following (GFL) counterparts to output the target active and reactive power. This will help the grid operator better manage their inverter-based resources (IBRs) for improved operation efficiency and reliability. Therefore, this paper proposes an innovative concept of dispatching GFM sources (inverters and SG) to output the target power for both grid-connected and islanded mode by adjusting their droop intercepts. The fundamental principle of doing so is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, thus, dispatching active and reactve power of a GFM inverter can be achieved through dispatching its frequency and voltage. Moreover, the concept distinguishes the dispatch rules for grid-connected and islanded mode. Finally, the concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one grid-following inverter and loads in both grid-connected and islanded mode. This pioneering work results in a practical guidance for power system energy management system (EMS) development to control a future grid with GFM and GFL inverters.

droop control↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode

This paper explores the dispatchability of grid-forming (GFM) inverters in grid-connected and islanded mode. GFM inverters usually use droop control to automatically share power with other GFM sources (inverters and synchronous generators) and follow the change in the load demand; however, they can be dispatched like their grid-following (GFL) counterparts to output the target active and reactive power. This will help grid operators better manage their inverter-based resources (IBRs) to improve operation efficiency and reliability; therefore, this paper proposes an innovative concept of dispatching GFM sources (inverters and synchronous generators) to output the target power in both grid-connected and islanded mode by adjusting their droop intercepts. The fundamental principle is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, and thus dispatching the active and reactve power of a GFM inverter can be achieved through dispatching its frequency and voltage. Moreover, the concept distinguishes the dispatch rules for grid-connected and islanded mode. Finally, the concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one GFL inverter, and the load in both grid-connected and islanded mode. This pioneering work results in practical guidance for the development of energy management systems for future electric grids with GFM and GFL inverters.

dispatching↗

Dispatching Grid-Forming Inverters in Grid-Connected and Islanded Mode

This paper explores the dispatchability of grid-forming (GFM) inverters in grid-connected and islanded mode. An innovative concept of dispatching GFM sources (inverters and synchronous generators) is proposed to output the target power by adjusting their droop intercepts. The fundamental principle is that the GFM inverter's active and reactive power is dictated by its frequency and voltage, and thus dispatching the active and reactive power of a GFM inverter can be achieved through dispatching its frequency and voltage. The concept is validated with an example microgrid system with two GFM inverters, one diesel generator, one GFL inverter, and the load in both grid-connected and islanded mode. This pioneering work results in practical guidance for the development of energy management systems for future electric grids with GFM and GFL inverters. The key findings are summarized as follows: 1) The GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power; 2) The dispatch rule for grid-connected and islanded mode is slightly different.

dispatch GFM inverter↗