Search NASA⌕ Search

SEARCH · Search NASA

Results for “H3D”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

H3D Data Acquisition Software (H3DDAQ) v1.0

A python library to enable readout of data from commercial H3D gamma-ray detectors. This software perform readout of data and system status, as well as starting and stopping measurements, with either WebREST (HTTP), XML (N42.42), or Binary (FlatBuffers) interfaces.

Joshi, Tenzing↗

H3D Characterization Memo

The H3D was characterized using GADRAS 19.3.5 using data sent by the IAEA. Everything related to the measurement setup was provided by the IAEA. The sources measured were detailed and the distance from the detector was also provided. The data sheets of the sources were used to determine the source activity at the time of calibration, as needed for characterization.

97 MATHEMATICS AND COMPUTING↗

A laboratory study of the 8.65 micron fundamental of (C-12)H3D at temperatures relevant to Titan's atmosphere

Spectral transmittance measurements have been performed in the nu6-fundamental of (C-12)H3D at 153 K. Relevant to the studies of the emission spectra of Titan recorded by the IRIS instruments on board Voyagers 1 and 2, N2 has been used as the broadening gas. Excellent agreement between experimental and theoretical spectral transmittance has been the result of using N2-broadened line widths and their dependence upon temperature measured in the nu2-fundamental and S = 63.6 per(sq cm atm) for the absolute intensity of the nu6-fundamental.

Varanasi, P.↗

Diode laser measurements of the band strengths of nu(3) and nu(6) in (C-12)H3D

A diode laser spectrometer has been used to measure line strengths for 143 transitions in the nu(6) fundamental band of (C-12)H3D near 9 microns. These line-strength measurements have been used to derive a band strength for nu(6) and nu(3). The band strength derived for nu(6) is 61.7 + or - 1.8/sq cm/atm and that for nu(3) is 49.3 + or - 1.4/sq cm/atm at 295 K.

Boyle, R. J.↗

Absolute intensities and self-, N2-, and air-broadened Lorentz halfwidths for selected lines in the nu3 band of (C-12)H3D from measurements with a tunable diode laser spectrometer

Absolute intensities and self-, air- and N2-broadened half-widths have been determined for the first time for individual lines in the nu3(A1) band of (C-12)H3D near 7.6 microns from measurements of individual vibration-rotation lines using a tunable diode laser spectrometer. The intensity measurements are believed to be accurate to within three percent. Within experimental uncertainties, equal broadening efficiencies are found for both air and nitrogen. Self-broadened half-widths determined for three transitions yield an average half-width value of 0.803 + or -0.0010/cm/atm at 296 K.

Malathy Devi, V.↗

Linewidth measurements in the thermal infrared bands of (C-12)H3D at planetary atmospheric temperatures

Collision-broadened halfwidths of three lines in the nu3 fundamental band and of four lines in the nu6 fundamental band of (C-12)H3D have been measured at temperatures between 123 and 295 K using the Doppler-limited spectral resolution of a tunable diode laser spectrometer. Temperature dependence of the linewidths has been determined in self-broadening and in broadening by H2, He and N2.

Varanasi, Prasad↗

INTEGRATION OF THE H3D-M400 DETECTOR AND SPOT ROBOT FOR AUTOMATED AREA SURVEY MISSIONS

Office of Nuclear Smuggling Detection and Deterrence (NSDD) is charged to identify and develop technologies to detect, disrupt, and investigate smuggling of radiological and nuclear materials •Border protection involves primary inspections using Radiation Portal Monitors (RPM), complimented with secondary and area survey inspections, usually performed manually using portable radiation detectors (PRDs) -RPM rely on fast technologies which provide quick scans of passing cargo/vehicles -Secondary inspections rely on trained, field deployed staff responsible for additional interdiction of screened cargo/vehicle putting them in potentially hazardous environment -Area survey inspections rely on trained, field deployed staff responsible for scanning and identifying presence of radiation while patrolling through a facility or public space •This project explores the use of technology which could reduce risks to field inspectors and add efficiency •The work presented here is a proof of principle of detector-robot integration to perform area survey inspections

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Gamma Spectrometry Code Rodeo for Uranium Enrichment—FY 2021 Report

In FY22, the participating Department of Energy (DOE) laboratories continued the work on the project “Gamma Spectrometry Code Rodeo for Uranium Enrichment”. Oak Ridge National Laboratory (ORNL) and Lawrence Livermore National Laboratory (LLNL) continued their efforts to acquire spectra using uranium sources. A collimator (with side and back shields) was custom designed and constructed at ORNL. Spectra were acquired at ORNL using the uranium enrichment standards supplied by New Brunswick Laboratory (NBL) and the collimated M400 detector. Spectra were also acquired using steel absorbers of different thickness placed between the source and the collimated M400 detector. The plan was to ship the collimator to LLNL so that spectra could be acquired using the LLNL detector in collimated geometries. This activity was suspended since problems were noticed with the performance of the LLNL M400 detector. Also, it was brought to light to the project team that some of the aspects of the M400 detector had been updated by the vendor H3D in response to requests by the IAEA. In February 2021, the ORNL and LLNL M400 detectors were returned to the H3D factory in order to resolve the problems with the LLNL detector and to update ORNL and LLNL detectors to the same configuration as the M400 supplied to the IAEA. H3D repaired the LLNL M400 and performed the IAEA updates on both the ORNL and LLNL detectors. ORNL and LLNL received the detectors in April 2021. Data acquisition was continued using the upgraded detectors. ORNL re-collected the spectra using point sources and the NBL standards in uncollimated and collimated geometries. The collimator was shipped from ORNL to LLNL. Spectra were acquired at LLNL through Q4 of FY22. When the ORNL spectra were examined closely, it became apparent that there were spurious artifacts present in some of the spectra. This rendered suspect the ORNL spectra collected in June/July 2021 time frame. ORNL contacted H3D and per H3D’s advice, the M400 detector was returned to H3D for repairs in mid-August 2021. H3D diagnosed the problem and established that the root cause was the extra tight packaging that created a strain on the CZT crystals, causing one of them to break down. The repaired M400 was returned to ORNL in early September 2021. ORNL re-started data acquisition for the third time. Data was continued to be acquired at ORNL and LLNL through September 2021. The ORNL and LLNL data will be shared with the principal investigators from the analyzing laboratories. The GADRAS code and FRAM have been developed to have the capability to analyze the M400 spectra. Good quality spectra from FY21 have been analyzed using modified versions of GADRAS and FRAM. The spectra have also been analyzed using the GEM code. The analysis results from GADRAS, FRAM and GEM codes are presented and discussed in this report. Some preliminary results from FRAM and GEM analysis were presented in February 2021 at the U-Pu Isotopics Workshop sponsored by the IAEA. CZTU code is being modified to analyze M400 spectra. Data collection, code development and analysis will be continued in FY22 as per the FY22 Project Work Plan (PWP).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FRAM Isotopic Analysis of High-Resolution CZT Data

H3D Inc. has introduced a new type of CZT detectors that has resolution several times better than that of a typical, single crystal CZT detector. The better resolution has made it easier for software codes to analyze its spectra for isotopic composition of nuclear materials. The Fixed-energy Response-function Analysis with multiple efficiency (FRAM) is one of such software codes. The good peak resolution of the H3D CZT detectors allows the current FRAM v.6.1 and earlier to successfully analyze uranium spectra with minimal modification of the parameter sets and get reasonable results. (A parameter set governs how an analysis is performed.) The exceptionally large high-energy tail of the peaks makes it difficult to achieve good uranium results and impossible to successfully analyze plutonium spectra. The FRAM code needed to be modified to better fit the high-energy tail of the peaks in order to analyze plutonium data and to get better uranium analysis results. Results of this modification, encoded in beta version FRAM v.7.0i, are reported herein.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Production-Ready CsPbBr3 Module Fabrication

The purpose of this SBIR was to work on evaluation, development, and testing of CsPbBr3 semiconductors for use in commercial gamma-ray detection. The overarching goal was to demonstrate the capability to fabricate functional detectors through resources available to H3D, Inc in pursuit of an alternative to CdZnTe for room-temperature semiconductor detectors. Throughout the project, CdZnTe crystals from Redlen were used as a control group to demonstrate whether the fabrication processes could produce reasonable results. The CdZnTe crystals were diced into roughly 6 mm x 6 mm x 4.5 mm pieces and electrodes were evaporated onto planar faces. In one case, pixels were patterned through a laser ablation method; in the other, a rudimentary pixel shadow-mask was fabricated, and the pixels were generated in the evaporation process. A 16 mm x 16 mm x 14 mm CsPbBr3 crystal was diced into four smaller crystals. These CsPbBr3 had electrodes applied in a similar way to the CdZnTe samples with a rudimentary mask used for pixels on the cathode. Tested CdZnTe pieces were found to generally function with reasonable, low-energy performance. CsPbBr3 crystals were found to be non-functional under forward bias with a large dark-current. A separate attempt, using reverse bias in a non-H3D, Inc test system, observed a dark current similar to previous observations, and some active pixels but no waveforms were observed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NDA Tech: Multimodal Data Fusion with 3D Gamma-Ray Imaging for Safeguards

The ultimate project goal is to improve quantitative results obtained by the IAEA with the H420 gamma ray imager. Distribution to the IAEA will be through incorporation of project results into the software provided with the device by our commercial partner, H3D, Inc. Toward achieving that goal, we have started discussions with H3D to identify the requisite software components and how they will mesh with their own internally developed contextual data systems and other extant software components. We have identified the coded-aperture response data cube as a key structure. Discussions on contextual imaging were informative but somewhat inconclusive as the project lead on contextual data (LBNL) has not been available.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Summary of the Workshop on M400 High-Resolution CZT Detector Safeguards Applications

In September 2023, the US Department of Energy (DOE) National Nuclear Security Administration’s (NNSA’s) Office of Nonproliferation and Arms Control sponsored a workshop on M400 high-resolution cadmium zinc telluride (CZT) detector safeguards applications under its Safeguards Technology Development Program. The workshop brought together internationally recognized subject matter experts (SMEs) in the field of gamma spectrometry and uranium/plutonium isotopic analysis and experts from H3D Inc. (H3D), the vendor for M400.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Performance of 8 × 8 × 32 and 10 × 10 × 32 mm 3 CdZnTe position-sensitive virtual Frisch-grid detectors for high-energy gamma ray cameras

CdZnTe (CZT) crystals with thicknesses up to 20 mm and diameters up to 75 mm have become available from Redlen Technologies, Inc. for making large-volume gamma-ray detectors. The modified growth and optimized annealing conditions allowed Redlen to minimize the dark current and improve the uniformity of CZT crystals. Two detector designs, pixelated (H3D) and position-sensitive virtual Frisch-grid (VFG), have greatly benefitted from the availability of such big crystals. Encouraging results from testing of 40×40×15 mm 3 pixelated detectors were recently reported by the University of Michigan. In this work, we evaluated the spectroscopic properties of 8×8×32 and 10×10×32 mm 3 crystals configured as position-sensitive VFG detectors. Both digitized waveforms and an analog ASIC were used to read and process the signals from the detectors and test their spectral- and spatial-resolution. The VFG design provides the flexibility to scale-up the dimensions of the detectors for the desired efficiency, while the position information allows for correcting the detectors' response non-uniformity caused by crystal defects and devices geometry, thereby reducing the instrument cost and making them more feasible for emerging applications in gamma-ray astronomy, nonproliferation, portal screening and nuclear safeguards, where large detector arrays are often required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Uranium measurements in the field using high-resolution cadmium zinc telluride detectors

A new generation of cadmium zinc telluride (CZT) detectors has become available and is being evaluated by the International Atomic Energy Agency (IAEA) for safeguards verifications in the field. The new CZT detector, model M400, is a room temperature spectrometer manufactured by H3D, Inc. The M400 demonstrates superior energy resolution, effective isotope identification capabilities, and convenient usability features when tested in a controlled laboratory environment. These characteristics define the M400 as a potential platform for IAEA field detection applications, which could become suitable for nuclear material characterization (e.g., enrichment verification) and nuclear safeguards missions. The capabilities of gamma spectrometry codes including Fixed energy, Response function Analysis with Multiple efficiencies (FRAM) from Los Alamos National Laboratory, CZT for Uranium (CZTU) from Lawrence Livermore National Laboratory, and Gamma Detector Response and Analysis Software (GADRAS) from Sandia National Laboratories were adapted for M400 spectra, and the performance of the codes has been validated. This was reported in a prior work. To further validate the performance of the high-energy resolution CZT detector and the isotopic analysis codes, a field measurement campaign consisting of uranium hexafluoride (UF 6 ) cylinder measurements was conducted at a fuel fabrication facility. A total of 34 Type 30B cylinders containing UF6 were measured using three different M400 CZT detectors. Each detector was outfitted with a custom rectangular collimator and shield made out T-Flex®, a tungsten-impregnated polymer. Measurements were performed at three different locations of the cylinder, ensuring that the measurement geometry satisfied the infinite thickness criterion. The spectra from the M400 CZT were analyzed using the code General Enrichment Meter (GEM). For analyzing the gamma-ray spectra from UF 6 cylinder, the GEM code is the appropriate tool since it relies only on the gamma-ray emissions from 235 U and not from other isotopes. Results from the spectral analysis were compared with the known abundance of 235 U in the cylinders, as well as with the International Target Values 2020 (ITV2020). The suitability of the different underlying techniques used by the various codes for UF 6 analysis is discussed. The challenges of measuring UF 6 contained in cylinders and mitigation strategies are highlighted.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unsupervised Learning for Improved Gamma-Ray Spectrometry in Pixelated Cadmium Zinc Telluride (CZT) Detectors

Machine learning has been found to be ubiquitously useful across many industries, presenting an opportunity to improve radiation detection performance using data-driven algorithms. Improved detector resolution can aid in the detection, identification, and quantification of radionuclides. Here, in this work, a novel, data-driven, unsupervised learning approach is developed to improve detector spectral characteristics by learning, and subsequently rejecting, poorly performing regions of the pixelated detector. Feature engineering is used to fit individual characteristic photo peaks to a Doniach lineshape with a linear background model. Then, principal component analysis is used to learn a lower-dimension latent space representation of each photo peak where the pixels are clustered, and subsequently ranked, based on the cluster mean distance to an optimal point. Pixels within the worst cluster(s) are rejected to improve the full-width at half-maximum (FWHM) by 10% to 15% (relative to the bulk detector) at 50% net efficiency when applied to training data obtained from measurements of a 100 μCi 154 Eu source using a H3D M400i pixelated cadmium zinc telluride detector. These results compare well with, but do not outperform, a greedy algorithm that accumulates pixels in order of FWHM from lowest to highest used as a benchmark. In the future, this approach can be extended to include the detector energy and angular response. Finally, the model is applied to newly seen natural and enriched uranium spectra relevant for nuclear safeguards applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data-Driven Optimization of Pixelated CdZnTe Spectrometers for Uranium Enrichment Assay

Here, in recent work [Vavrek et al. (2025)], we developed the performance optimization framework spectre-ml for gamma spectrometers with variable performance across many readout channels. The framework uses non-negative matrix factorization (NMF) and clustering to learn groups of similarly-performing channels and sweep through various learned channel combinations to optimize the performance tradeoff of including worse-performing channels for better total efficiency. In this work, we integrate the pyGEM uranium enrichment assay code with our spectre-ml framework, and show that the U-235 enrichment relative uncertainty can be directly used as an optimization target. We find that this optimization reduces relative uncertainties after a 30 -minute measurement by an average of 20%, as tested on six different H3D M400 CdZnTe spectrometers, which can significantly improve uranium non-destructive assay measurement times in nuclear safeguards contexts. Additionally, this work demonstrates that the spect re-ml optimization framework can accommodate arbitrary end-user spectroscopic analysis code and performance metrics, enabling future optimizations for complex Pu spectra.

Gamma-ray detection↗