Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEAT EXTRACTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Heat extraction from salinity-gradient solar ponds using heat pipe heat exchangers

This paper presents the results of experimental and theoretical analysis on the heat extraction process from solar pond by using the heat pipe heat exchanger. In order to conduct research work, a small scale experimental solar pond with an area of 7.0 m{sup 2} and a depth of 1.5 m was built at Khon Kaen in North-Eastern Thailand (16 27'N102 E). Heat was successfully extracted from the lower convective zone (LCZ) of the solar pond by using a heat pipe heat exchanger made from 60 copper tubes with 21 mm inside diameter and 22 mm outside diameter. The length of the evaporator and condenser section was 800 mm and 200 mm respectively. R134a was used as the heat transfer fluid in the experiment. The theoretical model was formulated for the solar pond heat extraction on the basis of the energy conservation equations and by using the solar radiation data for the above location. Numerical methods were used to solve the modeling equations. In the analysis, the performance of heat exchanger is investigated by varying the velocity of inlet air used to extract heat from the condenser end of the heat pipe heat exchanger (HPHE). Air velocity was found to have a significant influence on the effectiveness of heat pipe heat exchanger. In the present investigation, there was an increase in effectiveness by 43% as the air velocity was decreased from 5 m/s to 1 m/s. The results obtained from the theoretical model showed good agreement with the experimental data. (author)

14 SOLAR ENERGY↗

Numerical Simulation of Critical Factors Controlling Heat Extraction from Geothermal Systems Using a Closed-Loop Heat Exchange Method

Closed-loop heat exchange for geothermal energy production involves injecting working fluid down a well that extends through the geothermal resource over a significant length to absorb heat by conduction through the well pipe. The well then needs to return to the surface for energy recovery and fluid re-injection to complete the cycle. We have carried out mixed convective-conductive fluid-flow modeling using a wellbore flow model for TOUGH2 called T2Well to investigate the critical factors that control closed-loop geothermal energy recovery. T2Well solves a mixed explicit-implicit set of momentum equations for flow in the pipe with full coupling to the implicit three-dimensional integral finite difference equations for Darcy flow in the porous medium. T2Well has the option of modeling conductive heat flow from the porous medium to the pipe by means of a semi-analytical solution which makes the computation very efficient because the porous medium does not have to be discretized. When the fully three-dimensional option is chosen, the porous medium is discretized and heat flow to the pipe is by conduction and convection, depending on reservoir permeability and other factors. Simulations of the closed-loop system for a variety of parameter values have been carried out to elucidate the heat recovery process. To the extent that convection may occur to aid in heat delivery to the pipe, the permeability of the geothermal reservoir, whether natural or stimulated, is an important property in heat extraction. The injection temperature and flow rate of the working fluid strongly control the ultimate energy recovery. Pipe diameter also plays a strong role in heat extraction, but is correlated with flow rate. Similarly, the choice of working fluid plays an important role, with water showing better heat extraction than CO2 for certain flow rates, while the CO2 has higher pressure at the production wellhead which can aid in surface energy recovery. In general, we find complex interactions between the critical factors that will require advanced computational approaches to fully optimize.

Oldenburg, Curtis↗

SPC-71260 Rev 0 MARVEL Heat Extraction Subsystem Secondary Coolant Equipment (SCE) Design/Build

A. The Microreactor Applications Research Validation and Evaluation (MARVEL) reactor will offer experimental capabilities that are not currently available at DOE’s national laboratories. Idaho National Laboratory (INL), operated for the U.S. Department of Energy (DOE) by Battelle Energy Alliance, LLC (BEA) (Contractor hereafter) is procuring services for the design, analysis, fabrication, testing and delivery of a Secondary Coolant Equipment system (SCE). This specification contains the requirements for design, analysis, fabrication, testing and delivery of the SCE as described herein. The MARVEL reactor is a microreactor which uses eutectic sodium-potassium alloy (NaK) as a primary coolant. The primary coolant is circulated through four primary loops by natural convection of the coolant. In each loop is a closed well which will accommodate an intermediate heat exchanger (IHX) for extracting heat from the loop. These wells will be referred to in this specification as the “IHX wells.” It is intended for the IHX containment to also be filled with NaK. The MARVEL design team has determined that a Heat Extraction System (HES) using pumped NaK will be used to extract heat from the IHXs and deliver it to a downstream system for power generation or alternate process heat users. This Heat Extraction System will enable MARVEL operations including the ability to test, demonstrate, and address issues related to installation, startup, and operations. In addition, it will allow down-stream utilization of process heat for various uses. The objective of this specification is to develop the final design for the HES Secondary Coolant Equipment system (SCE) that will be used as the core of the HES. This system provides control of the NaK circulation between the MARVEL reactor and the subsequent process heat utilization systems. It does not include design of the Intermediate Heat Exchangers and piping inside the T-REXc pit in which the reactor is located. B. The MARVEL microreactor will be installed in the Transient Reactor Test Facility (TREAT) building in the Transient Reactor Test (TREAT) Micro-Reactor Experiment Cell (T-REXc) C. An INL Subcontractor has developed a conceptual design for this system per SPC-71145, referred to in that specification as the Process Heat Extraction System. SPC-71260 is based on the pumped NaK loop concept developed under SPC-71145. D. The SCE system design and (as option scope) fabrication shall be provided by the awardee of the subcontract (Subcontractor hereafter) pertaining to this Specification. Prior to shipment, the SCE will be fabricated, assembled, and tested at the Subcontractor’s facility. After successful completion of acceptance testing, the SCE and associated equipment will be shipped to the Materials and Fuels Complex (MFC) at the INL (Contractor’s Facility hereafter) to be installed by others in TREAT/T-REXc.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Applications of fractured continuum model to enhanced geothermal system heat extraction problems

This paper describes the applications of the fractured continuum model to the different enhanced geothermal systems reservoir conditions. The capability of the fractured continuum model to generate fracture characteristics expected in enhanced geothermal systems reservoir environments are demonstrated for single and multiple sets of fractures. Fracture characteristics are defined by fracture strike, dip, spacing, and aperture. The paper demonstrates how the fractured continuum model can be extended to represent continuous fractured features, such as long fractures, and the conditions in which the fracture density varies within the different depth intervals. Simulations of heat transport using different fracture settings were compared with regard to their heat extraction effectiveness. The best heat extraction was obtained in the case when fractures were horizontal. A conventional heat extraction scheme with vertical wells was compared to an alternative scheme with horizontal wells. The heat extraction with the horizontal wells was significantly better than with the vertical

Anisotropic permeability↗

SPC-71145 Rev 0 MARVEL Process Heat Extraction System Conceptual Design

The Microreactor Applications Research Validation and Evaluation (MARVEL) reactor will offer experimental capabilities that are not currently available at DOE’s national laboratories. The MARVEL reactor is a microreactor which uses eutectic sodium-potassium alloy (NaK) as a primary coolant. The primary coolant is circulated through four primary loops by natural convection of the coolant. In each loop is a closed well which will accommodate an intermediate heat exchanger (IHX) for extracting heat from the loop. These wells will be referred to in this specification as the “IHX wells”. It is intended for the IHX containment to also be filled with NaK. The MARVEL design team is currently looking for alternative means of extracting heat from these wells to be utilized in downstream applications. This Heat Utilization System (HUS) will enable MARVEL operations including the ability to test, demonstrate, and address issues related to installation, startup, and operations. In addition, it will allow down-stream utilization of process heat for various uses. Depending on the methodology used, the interface between the secondary coolant and the HUS is the Process Heat Extraction System (PHES) and is the subject of this specification.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Modeling of heat extraction from variably fractured porous media in Enhanced Geothermal Systems

Modeling of heat extraction in Enhanced Geothermal Systems is presented. The study builds on recent studies on the use of directional wells to improve heat transfer between doublet injection and production wells. The current study focuses on the influence of fracture orientation on production temperature in deep low permeability geothermal systems, and the effects of directional drilling and separation distance between boreholes on heat extraction. The modeling results indicate that fracture orientation with respect to the well-pair plane has significant influence on reservoir thermal drawdown. As a result, the vertical well doublet is impacted significantly more than the horizontal well doublet

15 GEOTHERMAL ENERGY↗

Design of a thermosyphon-based thermal valve for controlled high-temperature heat extraction

Conventional concentrated solar power (CSP) is a reliable alternative energy source that uses the sun’s heat to drive a heat engine to produce electrical power. An advantage of CSP is its ability to store thermal energy for use during off-sun hours which is typically done by storing sensible heat in molten salts. Alternatively, thermal energy may be stored as latent heat in a phase-change material (PCM), which stores large quantities of thermal energy in an isothermal process. On-sun, the PCM melts, storing energy. Off-sun, the latent heat is extracted to produce dispatchable electrical power. Here, this paper presents the design of a thermosyphon-based device with sodium working fluid that is able to extract heat from a source as demand requires. A prototype has been designed to transfer 37 kW of thermal energy from a 600°C molten PCM tank to an array of 9% efficient thermoelectric generators (TEGs) to produce 3 kW of usable electrical energy for 5 h. This “thermal valve” design incorporates a funnel to collect condensate and a central shut-off valve to control condensate gravity return to the evaporator. Three circumferential tubes allow vapour transport up to the condenser. Pressure and a thermal resistance models were developed to predict the performance of the thermal valve. The pressure model predicts that the thermal valve will function as designed. The thermal resistance model predicts a 5500× difference in total thermal resistance between “on” and “off” states. The evaporator and condenser walls comprise 96% of the “on” thermal resistance, while the small parasitic heat transfer in the “off” state is primarily (77%) due to radiation losses. Lastly, this simple and effective technology can have a strong impact on the feasibility, scalability, and dispatchability of CSP latent storage. In addition, other industrial and commercial applications can benefit from this thermal valve concept.

14 SOLAR ENERGY↗

Equipment Procurement and Final Design for the MARVEL High-Grade Heat Extraction System (HGHES)

This summer I worked on the design of a high-grade heat extraction system (HGHES) of the MARVEL Project. The MARVEL project at INL is a first-of-a-kind terrestrial microreactor to help provide a test platform to demonstrate the use of a microreactor to end customers and enable technology developers to test enabling microreactor technologies with a functional nuclear reactor. One of the project's main requirements is the reactors’ ability to deliver high-grade thermal power to end users, both for industrial and commercial use. The project required communication with multiple vendors for custom-made equipment, working with a high-temperature and high-pressure helium coolant system, and research of a Thermal Storage Unit (TSU).

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Methodology for Calculating EGS Electricity Generation Potential Based on the Gringarten Model for Heat Extraction From Fractured Rock

Existing methodologies for estimating the electricity generation potential of Enhanced Geothermal Systems (EGS) assume thermal recovery factors of 5% or less, resulting in relatively low volumetric electricity generation potentials for EGS reservoirs. This study proposes and develops a methodology for calculating EGS electricity generation potential based on the Gringarten conceptual model and analytical solution for heat extraction from fractured rock. The electricity generation potential of a cubic kilometer of rock as a function of temperature is calculated assuming limits on the allowed produced water temperature decline and reservoir lifetime based on surface power plant constraints. The resulting estimates of EGS electricity generation potential can be one to nearly two-orders of magnitude larger than those from existing methodologies. The flow per unit fracture surface area from the Gringarten solution is found to be a key term in describing the conceptual reservoir behavior. The methodology can be applied to aid in the design of EGS reservoirs by giving minimum reservoir volume, fracture spacing, number of fractures, and flow requirements for a target reservoir power output. Limitations of the idealized model compared to actual reservoir performance and the implications on reservoir design are discussed.

15 GEOTHERMAL ENERGY↗

Evaluating Heat Extraction Performance of Closed-Loop Geothermal Systems with Thermally Conductive Enhancements in Conduction-Only Reservoirs: Preprint

We investigated the impact of disc-shaped and linear thermal enhancements on performance of closed-loop geothermal systems using steady-state and transient COMSOL numerical simulations. Thermal enhancements refer to thermally conductive material introduced in the rocks surrounding a wellbore to compensate for the relatively low rock thermal conductivity and increase heat extraction. Materials proposed include composite cements with thermally conductive additives such as metals or graphite to obtain overall cement thermal conductivities of 10 to 100x the rock thermal conductivity. Our simulation approach was modeling a subsegment (e.g., 100 m long) of a wellbore with idealized (e.g., perfect disc-shaped) thermal enhancements, and we report results as relative increase in heat extraction with respect to systems without thermal enhancements. We did not evaluate technical feasibility or cost of installing thermal enhancements. Simulations indicate that for 5-mm thick disc-shaped thermal enhancements with 5-m radius, repeated every 1 m along the wellbore and with thermal conductivity of 100x the rock thermal conductivity, the thermal output increases roughly 20% with respect to a closed-loop system without thermal enhancements. For fishbone structure thermal enhancements, we estimate a roughly 7% increase in thermal output for 5-m long radially outward pipes with half the radius of the main wellbore, repeated every 2.5 m, with thermal conductivity of 100x the rock thermal conductivity.

advanced geothermal systems↗

Analysis on the Preliminary Gap Conductance Test with Single Primary Heat Extraction and Removal Emulator

Microreactor is a type of nuclear reactor that is intended to produce thermal energy from the micro and integrated design. Among various microreactor roadmaps, microreactor with heat pipes is one of the promising designs that under active development. At Idaho National Laboratory (INL) and supported by the Department of Energy (DOE) Microreactor Program (MRP), a Single Primary Heat Extraction and Removal Emulator (SPHERE) was developed. The main purpose of SPHRE is to understand thermal performance of heat pipe in the conjunction of heat source without using nuclear material. The heat pipe used in the SPHERE has sodium as a working fluid, with Argon gas in the vapor region, thus this heat pipe is variable conductance heat pipe (VCHP). The volume of non-condensable gas changes with power and elapsed time, so the area covered by non-condensable gas changes. This gives an effect that passively controls the cooling capability of condenser section. This preliminary experiment was intended to perform a gap conductance experiment that reveals heat transfer characteristics of gas at the gap around the heat pipe. However, there are not many experimental data that deals with heat transfer of the gas at the gap around heat pipe. In this research, the preliminary experimental result regarding to the heat pipe performance with different composition of gas at the gap, level of power is presented. The experimental data will be used for the validation study of SOCKEYE as a future plan.

42 ENGINEERING↗

Strain gauge for testing microreactor hexagonal core blocks in the Single Primary Heat Extraction and Removal Emulator

To support the development and deployment of microreactor technologies, experiments that help verify and validate reactor systems and components are performed at non-nuclear test facilities. The Single Primary Heat Extraction Removal Emulator at Idaho National Laboratory is one of these test facilities and was used to monitor a test article that has a prototypic geometry of a heat-pipe cooled microreactor core block. To collect crucial temperature and strain data during testing, temperature and strain sensing fiber optics were embedded to the surface of the test article using an ultrasonic additive manufacturing technique. To support and provide benchmark strain data for the embedded sensors, a commercial resistive strain gauge was attached. This report will discuss the results from the deployment of the commercial strain gauge which includes the setup/attachment strategies, data acquisition, and analysis of the strain data.

36 MATERIALS SCIENCE↗

Performance of Microreactor Test Article with Embedded Sensors During Testing in The Single Primary Heat Extraction and Removal Emulator

The nuclear industry is pursuing microreactors that can be factory assembled and deployed to remote regions for reliable power generation. One class of microreactors uses a monolithic metal core block coupled to heat pipes that use passive heat flow, increasing the surface area for heat transfer without requiring active coolant flow through the reactor core. Additional experimental testing is required to understand the heat rejection limitations of heat pipes and thermal stresses in the monolithic core block due to significant temperature gradients. This report describes the initial characterization and testing of a stainless-steel test article that was fabricated with embedded sensors to measure heat pipe performance limits, as well as spatially distributed temperatures and strains during electrically heated thermal testing to simulate nuclear heating. The electrically heated testing was performed in the Single Primary Heat Extraction and Removal Emulator facility located at Idaho National Laboratory. The ultimate goals of this work are to (1) accurately monitor temperature and strain distributions that result from differential thermal expansion in the test articles and (2) quantify the heat rejection limits of heat pipes as a function of operating temperature and working fluid during steady-state and transient operations. Initial tests focused on the feasibility of using advanced fiber-optic sensors and other sensor technologies to improve the understanding of temperature and strain distributions within the electrically heated experiments. However, these sensing capabilities could benefit the broader microreactor community if the sensors could be used to monitor component and system health during nuclear operations to inform a limited number of microreactor operators, ultimately reducing operation and maintenance costs and moving toward semiautonomous operation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A DISCUSSION ON UTILIZATION OF HEAT PIPE AND VAPOUR CHAMBER TECHNOLOGY AS A PRIMARY DEVICE FOR HEAT EXTRACTION FROM PHOTON ABSORBER SURFACES

Heat pipes and vapour chambers work on heat exchange phenomena of two-phase flow and are widely used for in-dustrial and commercial applications. These devices offer very high effective thermal conductivities (5,000-200,000 W/m/K) and are adaptable to various sizes, shapes, and ori-entations. Although they have been found to be an excel-lent thermal management solution for laptops, satellites, and many things in-between, heat pipes and vapour cham-bers have yet to be adopted for use at particle accelerator facilities where they offer the possibility of more compact and more efficient means to remove heat from unwanted synchrotron radiation. As with all technologies, there are inherent limitations. Foremost, they are limited by practi-cality to serve as local heat transfer devices; heat transfer over long distances is likely best provided by other means. Heat pipes also introduce unique failure modes which must be considered.

FEA↗

Influence of Reservoir Convection on Heat Extraction with Closed-Loop Geothermal Systems

Over the past few years, advancements in closed-loop geothermal systems (CLGS), also called advanced geothermal systems (AGS), have sparked a renewed interest in these types of designs. CLGS have certain advantages over traditional and enhanced geothermal systems (EGS), including not requiring in-situ reservoir permeability, conservation of the circulating fluid, and allowing for different fluids, including working fluids directly driving a turbine at the surface. CLGS may be attractive in environments where water resources are limited, rock contaminants must be avoided, and stimulation treatments are not available (e.g., due to regulatory or technical reasons). Despite these advantages, CLGS have some challenges, including limited surface area for heat transfer and requiring long wellbores and laterals to obtain multi-MW output in conduction-only reservoirs. CLGS have been investigated in conduction-only systems. In this paper, we explore the impact of both forced and natural convection on the levels of heat extraction with a CLGS deployed in a hot wet rock reservoir. We bound potential benefits of convection by investigating liquid reservoirs over a range of natural and forced convective coefficients. Additionally, we investigate the effects of permeability, porosity, and geothermal temperature gradient in the reservoir on CLGS outputs. Reservoir simulations indicate that reservoir permeabilities of at least ~100 mD are required for natural convection to increase the heat output with respect to a conduction-only scenario. The impact increases with increasing reservoir temperature. When subject to a forced convection flow field, Darcy velocities of at least 10-7 m/s are required to obtain an increase in heat output.

advanced geothermal systems↗

New geothermal heat extraction process to deliver clean power generation

A new method for capturing significantly more heat from low-temperature geothermal resources holds promise for generating virtually pollution-free electrical energy. Scientists at the Department of Energys Pacific Northwest National Laboratory will determine if their innovative approach can safely and economically extract and convert heat from vast untapped geothermal resources. The goal is to enable power generation from low-temperature geothermal resources at an economical cost. In addition to being a clean energy source without any greenhouse gas emissions, geothermal is also a steady and dependable source of power.

15 GEOTHERMAL ENERGY↗

Experimental demonstration of high-temperature (>1000 °C) heat extraction from a moving-bed oxidation reactor for thermochemical energy storage

Previously developed reduction-oxidation (redox) thermochemical energy storage technologies must store their products at high temperatures, complicating handling and transportation. This work describes a countercurrent, tubular, moving bed oxidation reactor at laboratory scale that produces high grade heat and allows solids to enter and exit the system at ambient temperatures. The particles implemented in the system consist of a novel magnesium manganese-oxide material well-suited for thermochemical energy storage. Output heat is obtained via a separate extraction gas flow, which exits from the middle portion of the main reactor tube. With this design, reactor temperatures in excess of 1000°C and extraction temperatures above 950°C were achieved. Deviation between the two measurements is a result of extraction thermocouple placement and losses in the reactor extraction arm; improvements to these parameters would bring the extraction temperature closer to the bed temperature. The reactor produces enough energy via oxidation to sustain both heat extraction and continued chemical reaction. During one representative steady state experiment at a particle flow rate of 1.5 g/s, an average of 447 W was extracted from the reactor out of an estimated 1083 W of released chemical energy for a duration of 70 minutes. Among the four experiments, the maximum bench-scale oxidation reactor energy efficiency of 36.2% and corresponding round-trip efficiency of 13.7% considering both redox reactors were demonstrated. Characteristics of an ideal system are considered and future improvements are proposed.

25 ENERGY STORAGE↗

Nuclear Reactor Heat Extraction for Synthetic Fuel Plants

This report looks at the viability and best approach when producing synthetic fuels using heat and power supplied by advanced nuclear energy systems. The report looks at a low temperature integration pathway with four types of advanced reactors: a pressurized water reactor (PWR), an advanced light water reactor (A-LWR), a sodium fast reactor (SFR), and a high-temperature gas-cooled reactor (HTGR). A failure modes and effects analysis (FMEA) of the coupling system between the nuclear plant and the synthetic fuel systems is performed with the goal of identifying the reliability of such a thermal delivery system. Furthermore, a high temperature pathway is investigated for synfuel coupling to determine if this is more efficient and more cost effective as a coupling approach.

10 - SYNTHETIC FUELS↗