Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEAT FLUX”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Comparison of the high temperature heat flux sensor to traditional heat flux gages under high heat flux conditions.

Four types of heat flux gages (Gardon, Schmidt-Boelter, Directional Flame Temperature, and High Temperature Heat Flux Sensor) were assessed and compared under flux conditions ranging between 100-1000 kW/m2, such as those seen in hydrocarbon fire or propellant fire conditions. Short duration step and pulse boundary conditions were imposed using a six-panel cylindrical array of high-temperature tungsten lamps. Overall, agreement between all gages was acceptable for the pulse tests and also for the step tests. However, repeated tests with the HTHFS with relatively long durations at temperatures approaching 1000ÀC showed a substantial decrease (10-25%) in heat flux subsequent to the initial test, likely due to the mounting technique. New HTHFS gages have been ordered to allow additional tests to determine the cause of the flux reduction.

Blanchat, Thomas K.↗

MHD flow of a Casson fluid with power law heat flux and heat source

This investigation looks at the effects of thermal radiation on the magnetohydrodynamic flow of Casson fluid over a stretched surface subject to power law heat flux and internal heat generation. Conservation of mass, linear momentum and energy are used in the development of relevant flow equations. Series solutions for velocity and temperature are derived. Effects of embedded physical parameters on the velocity and temperature profiles are analyzed. Numerical values of skin-friction coefficient and local Nusselt number are examined.

42 ENGINEERING↗

The interpretation of temperature and salinity variables in numerical ocean model output and the calculation of heat fluxes and heat content

Abstract. The international Thermodynamic Equation of Seawater 2010 (TEOS-10) defined the enthalpy and entropy of seawater, thus enabling the global ocean heat content to be calculated as the volume integral of the product of in situ density, ρ, and potential enthalpy, h0 (with reference sea pressure of 0 dbar). In terms of Conservative Temperature, Θ, ocean heat content is the volume integral of ρcp0Θ, where cp0 is a constant “isobaric heat capacity”. However, many ocean models in the Coupled Model Intercomparison Project Phase 6 (CMIP6) as well as all models that contributed to earlier phases, such as CMIP5, CMIP3, CMIP2, and CMIP1, used EOS-80 (Equation of State – 1980) rather than the updated TEOS-10, so the question arises of how the salinity and temperature variables in these models should be physically interpreted, with a particular focus on comparison to TEOS-10-compliant observations. In this article we address how heat content, surface heat fluxes, and the meridional heat transport are best calculated using output from these models and how these quantities should be compared with those calculated from corresponding observations. We conclude that even though a model uses the EOS-80, which expects potential temperature as its input temperature, the most appropriate interpretation of the model's temperature variable is actually Conservative Temperature. This perhaps unexpected interpretation is needed to ensure that the air–sea heat flux that leaves and arrives in atmosphere and sea ice models is the same as that which arrives in and leaves the ocean model. We also show that the salinity variable carried by present TEOS-10-based models is Preformed Salinity, while the salinity variable of EOS-80-based models is also proportional to Preformed Salinity. These interpretations of the salinity and temperature variables in ocean models are an update on the comprehensive Griffies et al. (2016) paper that discusses the interpretation of many aspects of coupled Earth system models.

54 ENVIRONMENTAL SCIENCES↗

Upper ocean mixing, surface heat fluxes, and heat content variability in the upper 150 m during Hurricane Laura (2020)

Observations (from thermistor sensors and a hurricane glider) and model-based temperature were used to answer questions including the following: 1) What physical and environmental conditions explain the rapid intensification of Hurricane Laura? 2) How did the pre-existing warm mixed layer at Stone mooring (StM) influence the degree of cooling in the mixed layer? 3) How did vertical mixing, surface heat fluxes, and advective processes collectively shape the mixed layer heat evolution at StM? Observations measured by thermistor sensors showed that Hurricane Laura induced a cooling of -1.2oC in the mixed layer when Hurricane Laura’s wind speed increased to 47 m/s on 26 August. This contrasts with the -1.04oC mixed layer temperature change estimated from model-based temperature. At StM, the presence of a 31oC warm mixed layer and elevated heat content (60-80kJ/cm2) effectively preconditioned the upper ocean ahead of Hurricane Laura’s passage. After Hurricane Laura passed, turbulent mixing associated with the storm transported the heat anomalies downward into subsurface layers. In addition, this study shows that a surface heat flux of 5.04 kJ/cm2 supported the intensity of Hurricane Laura as it traversed over the StM. Using a mixed layer heat balance model, this study shows that entrainment flux and surface flux mostly contributed to the observed change in the mixed layer temperature.

Tsai, Senam↗

Power Plant Testing of Ultrasonic Measurements of Temperature Distributions and Heat Fluxes to Heat Exchange Surfaces

Extreme environmental conditions are common in energy conversion applications, in which the most hardened insertion sensors often do not perform reliably for long. On the other hand, ultrasonic measurements can be acquired noninvasively, with sensitive components kept away from the damaging environment. We have previously developed the ultrasonic method for measuring the spatial distribution of temperatures in solid materials applicable when large thermal gradients are present. In the developed approach, we use the echogenically segmented ultrasound propagation path, structured to contain engineered or naturally occurring echogenic features, to produce a train of echoes in response to an external pulse of ultrasonic excitation. This paper outlines the testing results of this approach applied to the temperature distribution measurements to a waterwall of a 500 MW power-plant utility boiler. The validation results obtained over the prolonged power plant test show that the estimated temperature profile is correctly captured, and the measurement accuracy can be comparable with traditional insertion sensors, such as thermocouples. Overall, the testing has confirmed that the developed approach has matured to become an attractive alternative to conventional sensing in solving challenging problems of long-term temperature measurements in extreme environments. Heat fluxes and thermal stresses in the structure can then be characterized noninvasively using the measured temperature distribution as the basis.

Walton, Kenneth↗

Dependence of divertor heat flux widths on heating power, flux expansion, and plasma current in the NSTX

We report the dependence of the lower divertor surface heat flux profiles, measured from infrared thermography and mapped magnetically to the mid-plane on loss power into the scrape-off layer (P{sub LOSS}), plasma current (I{sub p}), and magnetic flux expansion (f{sub exp}), as well as initial results with lithium wall conditioning in NSTX. Here we extend previous studies [R. Maingi et al., J. Nucl. Mater. 363-365 (2007) 196-200] to higher triangularity similar to 0.7 and higher I{sub p} {le} 1.2 MA. First we note that the mid-plane heat flux width mapped to the mid-plane, {lambda}{sub q}{sup mid} is largely independent of P{sub LOSS} for P{sub LOSS} {ge} 4 MW. {lambda}{sub q}{sup mid} is also found to be relatively independent of f{sub exp}; peak heat flux is strongly reduced as f{sub exp} is increased, as expected. Finally, {lambda}{sub q}{sup mid} is shown to strongly contract with increasing I{sub p} such that {lambda}{sub q}{sup mid} {alpha} I{sub p}{sup -1.6} with a peak divertor heat flux of q{sub div,peak} similar to 15 MW/m{sup 2} when I{sub p} = 1.2 MA and P{sub LOSS} similar to 6 MW. These relationships are then used to predict the divertor heat flux for the planned NSTX-Upgrade, with heating power between 10 and 15 MW, B{sub t} = 1.01 and I{sub p}= 2.0 MA for 5 s.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dependence of divertor heat flux widths on heating power, flux expansion, and plasma current in the NSTX

Here, we report the dependence of the lower divertor surface heat flux profiles, measured from infrared thermography and mapped magnetically to the mid-plane on loss power into the scrape-off layer (P LOSS ), plasma current (I p ), and magnetic flux expansion (f exp ), as well as initial results with lithium wall conditioning in NSTX. Here we extend previous studies to higher triangularity ~0.7 and higher I p ≤ 1.2 MA. First we note that the mid-plane heat flux width mapped to the mid-plane, $λ^{mid}_q$, is largely independent of P LOSS for P LOSS ≥ 4 MW. $λ^{mid}_q$ is also found to be relatively independent of f exp ; peak heat flux is strongly reduced as f exp is increased, as expected. Finally, $λ^{mid}_q$ is shown to strongly contract with increasing I p such that $λ^{mid}_q$ ∝ I$^{-1.6}_p$ with a peak divertor heat flux of q div, peak ~ 15 MW/m 2 when I p = 1.2 MA and P LOSS ~ 6 MW. These relationships are then used to predict the divertor heat flux for the planned NSTX-Upgrade, with heating power between 10 and 15 MW, B t = 1.0 T and I p = 2.0 MA for 5 s.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heat flux viscosity in collisional magnetized plasmas

Momentum transport in collisional magnetized plasmas due to gradients in the heat flux, a “heat flux viscosity,” is demonstrated. Even though no net particle flux is associated with a heat flux, in a plasma there can still be momentum transport owing to the velocity dependence of the Coulomb collision frequency, analogous to the thermal force. This heat-flux viscosity may play an important role in numerous plasma environments, in particular, in strongly driven high-energy-density plasma, where strong heat flux can dominate over ordinary plasma flows. The heat flux viscosity can influence the dynamics of the magnetic field in plasmas through the generalized Ohm's law and may therefore play an important role as a dissipation mechanism allowing magnetic field line reconnection. The heat flux viscosity is calculated directly using the finite-difference method of Epperlein and Haines [Phys. Fluids 29, 1029 (1986)], which is shown to be more accurate than Braginskii's method [S. I. Braginskii, Rev. Plasma Phys. 1, 205 (1965)], and confirmed with one-dimensional collisional particle-in-cell simulations. The resulting transport coefficients are tabulated for ease of application.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel approach to evaluate soil heat flux calculation: An analytical review of nine methods

Abstract There are no direct methods to evaluate calculated soil heat flux (SHF) at the surface ( G 0 ). Instead, validation and cross evaluation of methods for calculating G 0 usually rely on the conventional calorimetric method or the degree of the surface energy balance closure. However, there is uncertainty in the calorimetric method itself, and factors apart from G 0 also contribute to nonclosure of the surface energy balance. Here we used a novel approach to evaluate nine different methods for calculating SHF, including the calorimetric method and methods based on analytical solutions of the heat diffusion equation. The SHF ( G z ) measured by a self‐calibrating SHF plate at a depth of z = 5 cm below the surface (hereafter G m _5 cm ) was deployed as a reference. Each SHF calculation method was assessed by comparing the calculated G z at the same depth (hereafter G c _5 cm ) with G m _5 cm . The calorimetric method and simple measurement method performed best in determining G c _5 cm but still underestimated G m _5 cm by 19% during the daytime. Possible causes for this underestimation include errors and uncertainties in SHF measurements and soil thermal properties, as well as the phase lag between G c _5 cm and G m _5 cm . Our results indicate that the calorimetric method achieves the most accurate SHF estimates if self‐calibrating SHF plates are deployed at two depths (e.g., 5 cm and 10 cm), soil temperature and water content measurements are made in a few depths between the two plates, and soil thermal properties are accurately quantified.

Gao, Zhongming↗

Contribution of the Two Types of Ekman Pumping Induced Eddy Heat Flux to the Total Vertical Eddy Heat Flux

Based on eddy-rich (0.1° horizontal resolution for ocean) Community Earth System Model simulations, we compute the Ekman pumping induced vertical eddy heat flux using two formulations: the classical and the Stern-Ekman pumping. The two mechanisms yield similar patterns in the eddy-induced vertical heat flux, showing strong upward heat flux in ocean frontal regions such as the western boundary current regions. Using the Gulf Stream Extension region as an example, we estimate (1) the Stern-Ekman pumping induced eddy heat flux is 23% and 12% of the total vertical eddy heat flux at 50 m depth during summer and winter, respectively; (2) the classical Ekman pumping accounts for 82% and 88% of the Stern-Ekman pumping induced eddy heat flux at 50 m during summer and winter, respectively. The second finding indicates eddy current feedback on wind stress is the primary cause for the upward eddy heat flux generated by Ekman pumping.

58 GEOSCIENCES↗

Striation pattern of target particle and heat fluxes in three dimensional simulations for DIII-D

The application of resonant magnetic perturbations results in a non-axisymmetric striation pattern of magnetic field lines from the plasma interior which intersect the divertor targets. The impact on related particle and heat fluxes is investigated by three dimensional computer simulations for two different recycling conditions (controlled via neutral gas pumping). It is demonstrated that a mismatch between the particle and heat flux striation pattern (splitting vs. no splitting), as is repeatedly observed in ITER similar shape H-mode plasmas at DIII-D, can be reproduced by the simulations for high recycling conditions at the onset of partial detachment. These results indicate that a detailed knowledge of the particle and energy balance is at least as important for realistic simulations as the consideration of a change in the magnetic field structure by plasma response effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of a multi-machine database on divertor heat fluxes

A coordinated effort to measure divertor heat flux characteristics in fully attached, similarly shaped H-mode plasmas on C-Mod, DIII-D, and NSTX was carried out in 2010 in order to construct a predictive scaling relation applicable to next step devices including ITER, FNSF, and DEMO. Few published scaling laws are available and those that have been published were obtained under widely varying conditions and divertor geometries, leading to conflicting predictions for this critically important quantity. This study was designed to overcome these deficiencies. Analysis of the combined data set reveals that the primary dependence of the parallel heat flux width is robustly inverse with I{sub p}, which all three tokamaks independently demonstrate. An improved Thomson scattering system on DIII-D has yielded very accurate scrape off layer (SOL) profile measurements from which tests of parallel transport models have been made. It is found that a flux-limited model agrees best with the data at all collisionalities, while a Spitzer resistivity model agrees at higher collisionality where it is more valid. The SOL profile measurements and divertor heat flux scaling are consistent with a heuristic drift based model as well as a critical gradient model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Turbulent transport regimes and the scrape-off layer heat flux width

Understanding the responsible mechanisms and resulting scaling of the scrape-off layer (SOL) heat flux width is important for predicting viable operating regimes in future tokamaks, and for seeking possible mitigation schemes. Here in this paper, we present a qualitative and conceptual framework for understanding various regimes of edge/SOL turbulence and the role of turbulent transport as the mechanism for establishing the SOL heat flux width. Relevant considerations include the type and spectral characteristics of underlying instabilities, the location of the gradient drive relative to the SOL, the nonlinear saturation mechanism, and the parallel heat transport regime. We find a heat flux width scaling with major radius R that is generally positive, consistent with previous findings [J. W. Connor et al., Nucl. Fusion 39, 169 (1999)]. The possible relationship of turbulence mechanisms to the neoclassical orbit width or heuristic drift mechanism in low (L) -mode and high (H) -mode plasmas is considered, together with implications for future experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Elucidating the Impact of Flow on Material-Sensitive Critical Heat Flux and Boiling Heat Transfer Coefficients: An Experimental Study with Various Materials

In this work, steady-state internal flow boiling critical heat flux (CHF) experiments were carried out at 10°C inlet subcooling and atmospheric pressure (84 kPa at an altitude of about 5300 feet) with mass flux ranging from 200 to 2,000 kg/m 2 -s on seven tube materials, including the accident-tolerant fuel cladding candidate FeCrAl (C26M) alloy. At a relatively low flow rate, the sensitivity of CHF to different materials was appreciable (the average difference among the tested materials was 19% at 200 kg/m 2 -s). As the absolute CHF differences stayed constant for higher flow rates, the increased flow rate led to reduced relative CHF differences among the tested materials (average relative difference of 15% at 1,000 kg/m 2 -s). FeCrAl alloy claddings that were oxidized under simulated Light Water Reactor (LWR) conditions yielded CHF comparable to as-received FeCrAl alloy cladding, with less than 1.8% difference. Experimental CHF results imply marginal material sensitivity impacts on the departure from nucleate boiling ratio in steady-state nuclear reactor cores. Yet, for accident progression analysis, material sensitivity may hold importance, as boiling behavior variation at low mass flux is appreciable. Macroscopic material parameters (surface wettability, surface roughness, and thermal properties) do not provide a suitable explanation for observed material-sensitive CHFs. Yet, surface roughness and thermal effusivity revealed power and linear relations, respectively, to the nucleate boiling heat transfer coefficients at low mass flux. At high mass flux, material sensitivity on nucleate boiling heat transfer significantly decreased due to the increased shear stress on boiling surface overwhelming material-related boiling implications.

36 MATERIALS SCIENCE↗

The role of parallel heat transport in the relation between upstream scrape-off layer widths and target heat flux width in H-mode plasmas of the National Spherical Torus Experiment

The physics of parallel heat transport was tested in the scrape-off layer (SOL) plasma of the National Spherical Torus Experiment [M. Ono et al., Nucl. Fusion 40, 557 (2000); S. M. Kaye et al., ibid. 45, S168 (2005)] tokamak by comparing the upstream electron temperature (T{sub e}) and density (n{sub e}) profiles measured by the midplane reciprocating probe to the heat flux (q{sub perpendicular}) profile at the divertor plate measured by an infrared camera. It is found that electron conduction explains the near SOL width data reasonably well while the far SOL, which is in the sheath limited regime, requires an ion heat flux profile broader than the electron one to be consistent with the experimental data. The measured plasma parameters indicate that the SOL energy transport should be in the conduction-limited regime for R-R{sub sep} (radial distance from the separatrix location) <2-3 cm. The SOL energy transport should transition to the sheath-limited regime for R-R{sub sep}>2-3 cm. The T{sub e}, n{sub e}, and q{sub perpendicular} profiles are better described by an offset exponential function instead of a simple exponential. The conventional relation between midplane electron temperature decay length ({lambda}{sub Te}) and target heat flux decay length ({lambda}{sub q}) is {lambda}{sub Te}=7/2{lambda}{sub q}, whereas the newly derived relation, assuming offset exponential functional forms, implies {lambda}{sub Te}=(2-2.5){lambda}{sub q}. The measured values of {lambda}{sub Te}/{lambda}{sub q} differ from the new prediction by 25%-30%. The measured {lambda}{sub q} values in the far SOL (R-R{sub sep}>2-3 cm) are 9-10 cm, while the expected values are 2.7<{lambda}{sub q}<4.9 cm (for the sheath-limited regime). We propose that the ion heat flux profile is substantially broader than the electron heat flux profile as an explanation for this discrepancy in the far SOL.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗