Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEXAPOLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of a simple 2.45 GHz microwave plasma with a repulsive double hexapole configuration

A simple and inexpensive 2.45 GHz microwave plasma source with a repulsive double hexapole configuration is described and characterized. In this work, the operation of the source is shown to be flexible in terms of electron density, electron temperature, and plasma uniformity even at low-pressures (approximately millitorr). It allows for easy control of the electron temperature (2-3.8 eV) and density ({approx}10{sup 9}-10{sup 10} cm{sup -3}) by removing either of the two hexapoles or by varying the separation distance between the two hexapoles. Characterization was done via information gathered from the usual Langmuir probe measurements for electron temperature and density. The source makes a resonant surface with its repulsive double hexapole magnetic configuration providing an additional longitudinal confinement near the walls midway between the two hexapoles. Magnetic field maps are presented for varying double hexapole distances. Power delivery for various settings is also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication of an optimized hexapole magnet for a 14.5 GHz electron cyclotron resonance ion source

A hexapole magnet for a 14.5 GHz electron cyclotron resonance (ECR) ion source, where the maximum radial field on the wall of the plasma chamber is higher than 1.1 T, has been designed and fabricated. The size of the outer diameter and the number of the sector of the hexapole are optimized for a 14.5 GHz ECR ion source with the help of a three-dimensional field calculation code. Moreover, to make a strong and long-life magnet against the demagnetic field on the hexapole multilayered structure in radial and axial directions is considered in the design. The distributions of the demagnetic fields are estimated by the calculation of the radial field in a hexapole magnet and the axial field from the solenoid coils. Proper grades of magnetic materials depending on the strength of the demagnetic field are applied for the different layers. The magnetic fields of the measured and calculated ones have been compared.

43 PARTICLE ACCELERATORS↗

Demagnetization analysis of an 18 GHz electron cyclotron resonance ion source permanent magnet hexapole

An upgrade of ECR2 at the Argonne Tandem Linac Accelerator System is under way, focusing on increasing the intensity capabilities of the facility. ECR2 is a room temperature electron cyclotron resonance ion source, and the upgrade has strict requirements to retain radial access to the plasma chamber and keep the ion source operating without the use of superconducting magnets. The upgrade design with respect to the magnet arrangement and magnetization vectors has recently been presented [R. C. Vondrasek, J. McLain, and R. H. Scott, J. Phys.: Conf. Ser. 2743 , 012044 (2024)] using the same magnetic material as the current ECR2 hexapole. A thorough exploration of the demagnetization potential of this hexapole was carried out, and the risk of demagnetization was deemed too high, despite the magnetic performance meeting the requirements for the upgrade. Additional permanent magnet materials are considered with their respective performance evaluated. Magnet strength and demagnetization resistance are investigated and optimized with the final room temperature design demonstrating a high temperature transient demagnetization resistance and a radial magnetic field of 1.18 T at the plasma chamber wall. Finally, the simulations of this hexapole suggest that it will be sufficient to optimize intensity with a 14.5 GHz driving frequency and will allow 18 GHz operation, while keeping a high safety margin for maintaining magnet performance.

Argonne Tandem Linac Accelerator System↗

The performance of primary Cs beam clocks using quadrupole and hexapole deflection systems. Consequences for time keeping

Since 1978 the time-and-frequency standard CS1 of the Physikalisch-Technische Bundesanstalt (PTB) has operated continuously as a 'primary clock'. Its uncertainty (7.1 to the negative 15th power) is considerably smaller than that of the other existing primary standards. The CS1 is equipped with a combination of quadrupole and hexapole magnets and uses a longitudinal C-field. Consequences of utilizing primary clocks of this quality for the generation of the International Atomic Time Scale TAI are discussed.

Becker, G.↗

Hexapole-compensated magneto-optical trap on a mesoscopic atom chip

Magneto-optical traps on atom chips are usually restricted to small atomic samples due to a limited capture volume caused primarily by distorted field configurations. Here we present a magneto-optical trap based on a millimeter-sized wire structure which generates a magnetic field with minimized distortions. Together with the loading from a high-flux two-dimensional magneto-optical trap, we achieve a loading rate of 8.4x10{sup 10} atoms/s and maximum number of 8.7x10{sup 9} captured atoms. The wire structure is placed outside of the vacuum to enable a further adaptation to new scientific objectives. Since all magnetic fields are applied locally without the need for external bias fields, the presented setup will facilitate parallel generation of Bose-Einstein condensates on a conveyor belt with a cycle rate above 1 Hz.

74 ATOMIC AND MOLECULAR PHYSICS↗

Hexapole magnet field analysis

Method rotates magnet about a wire loop of rectangular shape placed inside the pole tips and measures induced loop voltage with a wave analyzer. Quantitative field characteristics are determined from voltage induced at various harmonics of the rotation frequency.

Lacey, R. F.↗

Prospects of ion beam extraction and transport simulations (invited)

Beam profile measurements using viewing targets and emittance measurements with pepper pot devices have established new insights about the ion beam extracted from an electron cyclotron resonance ion source (ECRIS). In our measurements we have compared two different ECRISs of CAPRICE type, one source was equipped with a standard 1.0 T hexapole magnet, whereas for the other ion source a stronger hexapole magnet with a flux density of 1.2 T has been installed. The resulting ion beam profile for each individual charge state produced by different focal strengths of an optical element can be used to estimate the emittance, but it also shows the negative influence of the hexapole on the extracted ion beam. A hexapole correction would be desirable to improve further beam transport. A possible correction scheme will be discussed. All experimental observations can be reproduced by computer simulation if a magnetic plasma is assumed. When the Larmor radius for ions becomes small, collisions are negligible for the path of ions within the plasma. Low energy electrons are highly movable along the magnetic field lines and can compensate the ion space charge within the plasma chamber.

43 PARTICLE ACCELERATORS↗

Superconducting magnet performance for 28 GHz electron cyclotron resonance ion source developed at the Korea Basic Science Institute

A superconducting magnet for use in an electron cyclotron resonance ion source was developed at the Korea Basic Science Institute. The superconducting magnet is comprised of three solenoids and a hexapole magnet. According to the design value, the solenoid magnets can generate a mirror field, resulting in axial magnetic fields of 3.6 T at the injection area and 2.2 T at the extraction region. A radial field strength of 2.1 T can also be achieved by hexapole magnet on the plasma chamber wall. NbTi superconducting wire was used in the winding process following appropriate techniques for magnet structure. The final assembly of the each magnet involved it being vertically inserted into the cryostat to cool down the temperature using liquid helium. The performance of each solenoid and hexapole magnet was separately verified experimentally. The construction of the superconducting coil, the entire magnet assembly for performance testing and experimental results are reported herein.

43 PARTICLE ACCELERATORS↗

State-selective detection of velocity-filtered ND{sub 3} molecules

Translationally cold and slow ND{sub 3} is prepared by filtering the slow molecules from a thermal gas-phase sample using a curved electrostatic hexapole guide. This filter, like the curved quadrupole guide introduced by Rangwala et al. [Phys. Rev. A 67, 043406 (2003)] selects molecules by their forward velocity and effective electric dipole moment. Here we describe two main modifications with respect to previous work: (1) A segmented hexapole guide is used that produces a harmonic potential for the linearly Stark-shifted levels of ND{sub 3}. A curved guide is combined with a straight hexapole guide, and independent high-voltage supplies are employed to allow for bandpass velocity filtering. (2) State-selective laser ionization is used to obtain time- and state-selective detection of the guided molecules. This enables the experimental determination of the rotational state population of the guided molecules.

74 ATOMIC AND MOLECULAR PHYSICS↗

Preliminary results of the ion extraction simulations applied to the MONO1000 and SUPERSHyPIE electron cyclotron resonance ion sources

The goal of this article is to present simulations on the extraction from an electron cyclotron resonance ion source (ECRIS). The aim of this work is to find out an extraction system, which allows one to reduce the emittances and to increase the current of the extracted ion beam at the focal point of the analyzing dipole. But first, we should locate the correct software which is able to reproduce the specific physics of an ion beam. To perform the simulations, the following softwares have been tested: SIMION 3D, AXCEL, CPO 3D, and especially, for the magnetic field calculation, MATHEMATICA coupled with the RADIA module. Emittance calculations have been done with two types of ECRIS: one with a hexapole and one without a hexapole, and the difference will be discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First plasma of the A-PHOENIX electron cyclotron resonance ion source

A-PHOENIX is a new compact hybrid electron cyclotron resonance ion source using a large permanent magnet hexapole (1.92 T at the magnet surface) and high temperature superconducting Solenoids (3 T) to make min-vertical bar B vertical bar structure suitable for 28 GHz cw operation. The final assembly of the source was achieved at the end of June 2007. The first plasma of A-PHOENIX at 18 GHz was done on the 16th of August, 2007. The technological specificities of A-PHOENIX are presented. The large hexapole built is presented and experimental magnetic measurements show that it is nominal with respect to simulation. A fake plasma chamber prototype including thin iron inserts showed that the predicted radial magnetic confinement can be fulfilled up to 2.15 T at the plasma chamber wall. Scheduled planning of experiments until the end of 2008 is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation of Unidirectional Ion Ejection in an Asymmetric Half-Round Rod Electrode Linear Ion Trap Mass Analyzer

An asymmetric trapping field was generated from an asymmetric half-round rod electrode linear ion trap (A-HreLIT), and its performance of unidirectional ion ejection was studied. Two different asymmetric structures of A-HreLITs were constructed, one rotating y electrode pairs toward an x electrode with an angle θ, and the other stretching one x electrode with a distance α. The center of trapping field was displaced away from the geometrical center of the ion trap, defined to be the midpoint along the axis of y between x electrodes, which leads to unidirectional ion ejection through one x electrode. Computer simulations were used to investigate the relationship between asymmetric geometric parameter of θ (or α) and analytical performance. Both structures could result in similar asymmetric trapping fields, which mainly composed of dipole, quadrupole, and hexapole fields. The dipole and hexapole fields were approximately proportional to the asymmetric geometric parameter of rotation angle θ (or stretch distance α). In simulation, ion trajectories and ion kinetic energy were calculated. For ions with m/z 609 Th, the simulation results showed that mass resolution of over 2400 (FWHM) and ion unidirectional ejection efficiency of nearly 90% were achieved in an optimized A-HreLIT. Ion detection efficiency of A-HreLIT could be improved significantly with only one ion detector, while maintaining a considerable mass resolution. Furthermore, the A-HreLIT could be driven by a traditional balanced RF power supply. These advantages make A-HreLIT suitable for developing miniaturized mass spectrometer with high performance. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A two-dimensional MHD global coronal model - Steady-state streamers

A 2D, time-dependent, numerical, MHD model for the simulation of coronal streamers from the solar surface to 15 solar is presented. Three examples are given; for dipole, quadrupole and hexapole (Legendre polynomials P1, P2, and P3) initial field topologies. The computed properties are density, temperature, velocity, and magnetic field. The calculation is set up as an initial-boundary value problem wherein a relaxation in time produces the steady state solution. In addition to the properties of the solutions, their accuracy is discussed. Besides solutions for dipole, quadrupole, and hexapole geometries, the model use of realistic values for the density and Alfven speed while still meeting the requirement that the flow speed be super-Alfvenic at the outer boundary by extending the outer boundary to 15 solar radii.

Wang, A.-H.↗

Design, construction, and first commissioning results of superconducting source for ions at NSCL/MSU

A new electron cyclotron resonance ion source (ECRIS) was constructed at the NSCL/MSU to replace the existing SC-ECRIS. This ECRIS operates at 18+14.5 GHz microwave frequencies with a planned upgrade to 24-28 GHz in the second phase of commissioning. A superconducting hexapole coil system produce the radial magnetic field; the axial trapping is produced with six superconducting solenoid coils enclosed in an iron yoke to allow the optimization of the distance between the plasma electrode and the resonant zone in the plasma. We report the details of the design, construction, and initial commissioning results of this new ECRIS.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electron cyclotron resonance ion sources with arc-shaped coils

The minimum-B magnetic field structure of electron cyclotron resonance ion sources (ECRIS) has conventionally been formed with a combination of solenoids and a hexapole magnet. However, minimum-B structure can also be formed with arc-shaped coils. Recently it was shown that multiply charged heavy-ions can be produced with an ECRIS based on such a structure. In the future, the ARC-ECRIS magnetic field structure can be an interesting option for radioactive ion-beam sources and charge-breeders as well as for high performance ECRIS allowing for 100 GHz plasma heating. This paper presents some design aspects of the ARC-ECRIS.

43 PARTICLE ACCELERATORS↗

High-resolution slice imaging of quantum state-to-state photodissociation of methyl bromide

The photodissociation of rotationally state-selected methyl bromide is studied in the wavelength region between 213 and 235 nm using slice imaging. A hexapole state selector is used to focus a single (JK=11) rotational quantum state of the parent molecule, and a high speed slice imaging detector measures directly the three-dimensional recoil distribution of the methyl fragment. Experiments were performed on both normal (CH{sub 3}Br) and deuterated (CD{sub 3}Br) parent molecules. The velocity distribution of the methyl fragment shows a rich structure, especially for the CD{sub 3} photofragment, assigned to the formation of vibrationally excited methyl fragments in the {nu}{sub 1} and {nu}{sub 4} vibrational modes. The CH{sub 3} fragment formed with ground state Br({sup 2}P{sub 3/2}) is observed to be rotationally more excited, by some 230-340 cm{sup -1}, compared to the methyl fragment formed with spin-orbit excited Br({sup 2}P{sub 1/2}). Branching ratios and angular distributions are obtained for various methyl product states and they are observed to vary with photodissociation energy. The nonadiabatic transition probability for the {sup 3}Q{sub 0+}{yields}{sup 1}Q{sub 1} transition is calculated from the images and differences between the isotopes are observed. Comparison with previous non-state-selected experiments indicates an enhanced nonadiabatic transition probability for state-selected K=1 methyl bromide parent molecules. From the state-to-state photodissociation experiments the dissociationenergy for both isotopes was determined, D{sub 0}(CH{sub 3}Br)=23 400{+-}133 cm{sup -1} and D{sub 0}(CD{sub 3}Br)=23 827{+-}94 cm{sup -1}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An electron cyclotron resonance plasma configuration for increasing the efficiency in the yield of nitrogen endohedral fullerenes

Efficiently yielding a nitrogen-atom endohedral fullerene (N-C{sub 60}) is demonstrated for the first time using an electron cyclotron resonance (ECR) plasma source with a minimum-B mirror configuration realized by hexapole permanent magnets. Since electrons are effectively confined around a bottom of the minimum-B mirror in the ECR region, the high-temperature electrons can be generated there, and as a result, the dissociation degree of the nitrogen molecules increases drastically. This highly dissociated nitrogen plasma has a number of nitrogen-atom radicals and ions, thus permitting an enhancement of N-C{sub 60} yield.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗