Steady Surface Pressure Measurement via the Lifetime Method With High-Speed Cameras in NASA's Unitary Plan Wind Tunnel

High spatial resolution measurement of steady surface pressure via pressure-sensitive paint at NASA Ames has traditionally relied on specialized cameras equipped to accumulate charge over multiple exposures, whereas measurement of the fluctuating component of pressure uses an altogether separate set of high-speed cameras. To reduce complexity of installation, data acquisition, and processing, we have implemented methods to use a single set of commercial off-the-shelf cameras to produce both steady and unsteady pressure measurements. Both imaging systems were installed in the 11-by 11-foot NASA Ames Unitary Plan Wind Tunnel and acquired images of a scaled model of the Space Launch System Block 1B Crew and Cargo configurations over a variety of flow conditions. This work focuses on methods for data acquisition, processing, and calibration to produce steady-state pressure estimates on the surface of the wind tunnel model based on the lifetime method. It will then compare the steady solutions produced by the legacy and high-speed imaging systems.

Pressure Sensitive Paint

High-speed camera synchronization

Photoelectric sensor enables synchronization of the rotating mirror in a high-speed framing camera with the passage of a very-high-velocity droplet to obtain direct photographic data on droplet breakup. It detects droplet movement across a high intensity light beam and generates a signal triggering the camera.

Rojec, E. A.

Application of Optical Measurement Techniques During Stages of Pregnancy: Use of Phantom High Speed Cameras for Digital Image Correlation (D.I.C.) During Baby Kicking and Abdomen Movements

Paired images were collected using a projected pattern instead of standard painting of the speckle pattern on her abdomen. High Speed cameras were post triggered after movements felt. Data was collected at 120 fps -limited due to 60hz frequency of projector. To ensure that kicks and movement data was real a background test was conducted with no baby movement (to correct for breathing and body motion).

Gradl, Paul

Electro-optical time marker for high-speed cameras

Electro-optical device converts high-frequency electrical pulses into permanent optical records on film. Accurate, well defined images are formed of electronic pulses having repetition rates greater than 10,000 pulses/sec and pulse widths of 20 microseconds or less. Small electronic switch drives a silicon carbide electroluminescent diode.

Copeland, J. T., Jr.

Applications and Development Work for Digital Image Correlation Using High Speed Cameras

NASA, Army, and industry partners are working to advance optical measurement techniques used in highly dynamic rocket engine and missile test environments. This allows for direct component data collection during test and flight environments, significantly reduced analysis time, and associated cost savings. Digital Image Correlation (DIC) uses calibrated stereo cameras to collect three-dimensional (3-D) displacements, strains, and acceleration data by referencing a stochastic speckle pattern applied to the test object. These optical measurement techniques provide significantly improved data resulting in better performance predictions, model validation, and information about components during hot-fire tests and test flights.

Rachel Paden

High Speed Digital Camera Technology Review

A High Speed Digital Camera Technology Review (HSD Review) is being conducted to evaluate the state-of-the-shelf in this rapidly progressing industry. Five HSD cameras supplied by four camera manufacturers participated in a Field Test during the Space Shuttle Discovery STS-128 launch. Each camera was also subjected to Bench Tests in the ASRC Imaging Development Laboratory. Evaluation of the data from the Field and Bench Tests is underway. Representatives from the imaging communities at NASA / KSC and the Optical Systems Group are participating as reviewers. A High Speed Digital Video Camera Draft Specification was updated to address Shuttle engineering imagery requirements based on findings from this HSD Review. This draft specification will serve as the template for a High Speed Digital Video Camera Specification to be developed for the wider OSG imaging community under OSG Task OS-33.

Clements, Sandra D.

High-speed pulse camera

Miniaturized, 16 mm high speed pulse camera takes spectral photometric photographs upon instantaneous command. The design includes a low-friction, low-inertia film transport, a very thin beryllium shutter driven by a low-inertia stepper motor for minimum actuation time after a pulse command, and a binary encoder.

Lawson, J. R.

Quantitative Radiation Thermometry Using Commercially Available High-Speed Video Cameras

In order to understand the risk posed to astronauts by electric arc-generated particles, high-speed, high-resolution, quantitative thermal imaging was needed. The measurement requirements appeared to be beyond the capabilities of commercial thermal imaging systems, but the particles were known to have a significant amount of emission in the visible spectrum. This led to the use of commercially available, high-speed video cameras as imaging radiometers. Measured particle temperatures were consistent with predictions and other measurement data. The optical temperature measurement method, results, and conclusions are presented, along with recommendations for further work.

Thermal imaging

Precision of FLEET Velocimetry Using High-speed CMOS Camera Systems

Femtosecond laser electronic excitation tagging (FLEET) is an optical measurement technique that permits quantitative velocimetry of unseeded air or nitrogen using a single laser and a single camera. In this paper, we seek to determine the fundamental precision of the FLEET technique using high-speed complementary metal-oxide semiconductor (CMOS) cameras. Also, we compare the performance of several different high-speed CMOS camera systems for acquiring FLEET velocimetry data in air and nitrogen free-jet flows. The precision was defined as the standard deviation of a set of several hundred single-shot velocity measurements. Methods of enhancing the precision of the measurement were explored such as digital binning (similar in concept to on-sensor binning, but done in post-processing), row-wise digital binning of the signal in adjacent pixels and increasing the time delay between successive exposures. These techniques generally improved precision; however, binning provided the greatest improvement to the un-intensified camera systems which had low signal-to-noise ratio. When binning row-wise by 8 pixels (about the thickness of the tagged region) and using an inter-frame delay of 65 micro sec, precisions of 0.5 m/s in air and 0.2 m/s in nitrogen were achieved. The camera comparison included a pco.dimax HD, a LaVision Imager scientific CMOS (sCMOS) and a Photron FASTCAM SA-X2, along with a two-stage LaVision High Speed IRO intensifier. Excluding the LaVision Imager sCMOS, the cameras were tested with and without intensification and with both short and long inter-frame delays. Use of intensification and longer inter-frame delay generally improved precision. Overall, the Photron FASTCAM SA-X2 exhibited the best performance in terms of greatest precision and highest signal-to-noise ratio primarily because it had the largest pixels.

Peters, Christopher J.

Precision of FLEET Velocimetry Using High-Speed CMOS Camera Systems

Femtosecond laser electronic excitation tagging (FLEET) is an optical measurement technique that permits quantitative velocimetry of unseeded air or nitrogen using a single laser and a single camera. In this paper, we seek to determine the fundamental precision of the FLEET technique using high-speed complementary metal-oxide semiconductor (CMOS) cameras. Also, we compare the performance of several different high-speed CMOS camera systems for acquiring FLEET velocimetry data in air and nitrogen free-jet flows. The precision was defined as the standard deviation of a set of several hundred single-shot velocity measurements. Methods of enhancing the precision of the measurement were explored such as digital binning (similar in concept to on-sensor binning, but done in post-processing), row-wise digital binning of the signal in adjacent pixels and increasing the time delay between successive exposures. These techniques generally improved precision; however, binning provided the greatest improvement to the un-intensified camera systems which had low signal-to-noise ratio. When binning row-wise by 8 pixels (about the thickness of the tagged region) and using an inter-frame delay of 65 microseconds, precisions of 0.5 meters per second in air and 0.2 meters per second in nitrogen were achieved. The camera comparison included a pco.dimax HD, a LaVision Imager scientific CMOS (sCMOS) and a Photron FASTCAM SA-X2, along with a two-stage LaVision HighSpeed IRO intensifier. Excluding the LaVision Imager sCMOS, the cameras were tested with and without intensification and with both short and long inter-frame delays. Use of intensification and longer inter-frame delay generally improved precision. Overall, the Photron FASTCAM SA-X2 exhibited the best performance in terms of greatest precision and highest signal-to-noise ratio primarily because it had the largest pixels.

Peters, Christopher J.

Launch Vehicle Loads Analysis Using Pressure-Sensitive Paint

Pressure transducers have been the instrumentation of choice for measuring unsteady flow phenomena. With recent advances in high-speed cameras, high-powered LEDs, and fast-response, pressure-sensitive paint, the unsteady pressure-sensitive paint (uPSP) technique has become a valuable alternative for production wind tunnel facilities, enabling time-resolved measurements of unsteady pressure fluctuations over a dense spatial grid on a wind tunnel model. Launch vehicle ground tests have proven to be a particularly well-matched application for uPSP due to the high signal level relative to tunnel background acoustics, relatively simple camera optical access, and rigidity of the model in wind-on test conditions. This presentation will highlight recent advances in data reduction of uPSP measurement data from recent launch vehicle wind tunnel tests at the NASA Ames Unitary Plan Wind Tunnel Complex (UPWT). The system can provide both localized surface pressure spectra as well as regional or zonal estimates of turbulence correlation model parameters. In addition, integrated vehicle-scale loads can be provided for buffet analysis. Data is reduced at the on-premise NASA Advanced Supercomputer (NAS) Division for just-in-time delivery of results during an ongoing wind tunnel test.

Pressure-Sensitive Paint

Launch Vehicle Loads Analysis Using Pressure-Sensitive Paint

Pressure transducers have been the instrumentation of choice for measuring unsteady flow phenomena. With recent advances in high-speed cameras, high-powered LEDs, and fast-response, pressure-sensitive paint, the unsteady pressure-sensitive paint (uPSP) technique has become a valuable alternative for production wind tunnel facilities, enabling time-resolved measurements of unsteady pressure fluctuations over a dense spatial grid on a wind tunnel model. Launch vehicle ground tests have proven to be a particularly well-matched application for uPSP due to the high signal level relative to tunnel background acoustics, relatively simple camera optical access, and rigidity of the model in wind-on test conditions. This presentation will highlight recent advances in data reduction of uPSP measurement data from recent launch vehicle wind tunnel tests at the NASA Ames Unitary Plan Wind Tunnel Complex (UPWT). The system can provide both localized surface pressure spectra as well as regional or zonal estimates of turbulence correlation model parameters. In addition, integrated vehicle-scale loads can be provided for buffet analysis. Data is reduced at the on-premise NASA Advanced Supercomputer (NAS) Division for just-in-time delivery of results during an ongoing wind tunnel test.

pressure-sensitive paint

Implementation of the Lifetime Method in uPSP Measurements

At NASA Ames Research Center, unsteady pressure-sensitive paint (uPSP) measurements are obtained using the ‘intensity method’ which measures paint luminescence in response to a continuous, constant excitation. These measurements are obtained using high-speed cameras and are processed into fluctuating components of pressure. However, the nature of the intensity method also requires a separate steady state (time mean) pressure measurement to be obtained. This steady state measurement has typically been obtained using a separate set of PSP equipment that uses the ‘lifetime method’, which uses pulsed excitation to measure paint decay lifetime. If the lifetime method were implemented in the high-speed uPSP system, both the fluctuating and mean components of pressure could be obtained with a single system. This would greatly streamline setup, operations, and processing. In this paper, we describe work performed at the Fluid Mechanics Laboratory at NASA Ames to implement the lifetime method in our uPSP system. The uPSP acquisition system uses Phantom v2512 high-speed cameras, and it was initially uncertain if results of adequate quality could be obtained - their high framerate comes at the cost of several undesirable characteristics, which are explored in this paper. It was also uncertain if illumination using LED lamps, rather than a stronger source such as lasers, would be adequate. The data acquisition and data processing are discussed and the results analyzed. It was found that satisfactory lifetime method results can indeed be obtained using these high-speed cameras and LED lamps. This will allow the uPSP system to be greatly simplified and will have a large operational impact on how uPSP data is acquired in future wind tunnel tests.

Pressure Sensitive Paint

Implementation of the Lifetime Method in Unsteady Pressure Sensitive Paint Measurements

At NASA Ames Research Center, unsteady pressure-sensitive paint (uPSP) measurements are obtained using the ‘intensity method’ which measures paint luminescence in response to a continuous, constant excitation. These measurements are obtained using high-speed cameras and are processed into fluctuating components of pressure. However, the nature of the intensity method also requires a separate steady state (time mean) pressure measurement to be obtained. This steady state measurement has typically been obtained using a separate set of PSP equipment that uses the ‘lifetime method’, which uses pulsed excitation to measure paint decay lifetime. If the lifetime method were implemented in the high-speed uPSP system, both the fluctuating and mean components of pressure could be obtained with a single system. This would greatly streamline setup, operations, and processing. In this paper, we describe work performed at the Fluid Mechanics Laboratory at NASA Ames to implement the lifetime method in our uPSP system. The uPSP acquisition system uses Phantom v2512 high-speed cameras, and it was initially uncertain if results of adequate quality could be obtained - their high framerate comes at the cost of several undesirable characteristics, which are explored in this paper. It was also uncertain if illumination using LED lamps, rather than a stronger source such as lasers, would be adequate. The data acquisition and data processing are discussed and the results analyzed. It was found that satisfactory lifetime method results can indeed be obtained using these high-speed cameras and LED lamps. This will allow the uPSP system to be greatly simplified and will have a large operational impact on how uPSP data is acquired in future wind tunnel tests.

Pressure Sensitive Paint

Flame Structure Comparison using Jet-A and an isoparaffinic fuel in a lean direct injection flame tube combustor

This paper offers a first look at some recently acquired optical data. The effect of reference velocity on flame thickness, fuel atomization, and relative speciation of OH, CH, C2, and soot for two National Jet Fuel Combustion Program (NJFCP) fuels are explored in this paper. The NJFCP fuels are an average Jet-A, designated A-2 with a derived cetane number (DCN) of 49, and an isoparaffinic kerosene, C-4. C-4 fuel is made up primarily of C9 - C13, and C16 isoparaffins and is a combination of 60% Sasol IPK and 40% GEVO alcohol-to-jet (ATJ). C-4 has a DCN of 28. Both fuels begin distillation at about the same temperature, but C-4 completes about 30 degrees Celsius lower than A-2. Chemiluminescence images were acquired in a 5-atm gas turbine flame tube combustor using the NASA 7-point lean direct injector (LDI). The flame characteristics were determined through imaging with three scientific cameras. OH*, CH*, and C2* chemiluminescence were collected through narrow bandpass filters centered at 313nm, 430nm and 515nm onto an intensified high-speed camera framed at 8-kHz. A second high-speed camera collected color flame images at rates between 40 and 50 kHz. An ICCD camera framed at 20 Hz was used to record planar laser scatter from liquid fuel. Differences in speciation for the chemiluminescent species was observed between the two fuels. Some reasons for the differences are explored in this paper.

gas turbine combustion