Search NASA⌕ Search

SEARCH · Search NASA

Results for “HIP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Hip Abductor Strength Asymmetry: Relationship to Upper Extremity Injury in Professional Baseball Players

Background: Hip strength is an important factor for control of the lumbo-pelvic-hip complex. Deficits in hip strength may affect throwing performance and contribute to upper extremity injuries. Hypothesis: Deficits in hip abduction isometric strength would be greater in those who sustained an upper extremity injury and hip strength would predict injury incidence. Study Design: Prospective cohort study. Level of Evidence: Level 3. Methods: Minor League baseball players (n = 188, age = 21.5 ± 2.2 years; n = 98 pitchers; n = 90 position players) volunteered. Hip abduction isometric strength was assessed bilaterally with a handheld dynamometer in side-lying position, expressed as torque using leg length (N·m). Hip abduction strength asymmetry was represented by [(trail leg/lead leg) × 100]. Overuse or nontraumatic throwing arm injuries were prospectively tracked. Poisson regression models were used to estimate relative risk ratios associated with hip asymmetry; confounders, including history of prior overuse injury in the past year, were included. Results: Hip abduction asymmetry ranged from 0.05% to 57.5%. During the first 2 months of the season, 18 players (n = 12 pitchers) sustained an upper extremity injury. In pitchers, for every 5% increase in hip abduction asymmetry, there was a 1.24 increased risk of sustaining a shoulder or elbow injury. No relationship between hip abduction strength and injury was observed for position players. Conclusion: Hip abduction asymmetry in pitchers was related to subsequent upper extremity injuries. The observed risk ratio indicates that hip abduction asymmetry may contribute a significant but small increased risk of injury. Clinical Relevance: Hip abduction muscle deficits may affect pitching mechanics and increase arm stress. Addressing hip asymmetry deficits that exceed 5% may be beneficial in reducing upper extremity injury rates in pitchers.

Sport Sciences↗

Ankle and hip postural strategies defined by joint torques

Previous studies have identified two discrete strategies for the control of posture in the sagittal plane based on EMG activations, body kinematics, and ground reaction forces. The ankle strategy was characterized by body sway resembling a single-segment-inverted pendulum and was elicited on flat support surfaces. In contrast, the hip strategy was characterized by body sway resembling a double-segment inverted pendulum divided at the hip and was elicited on short or compliant support surfaces. However, biomechanical optimization models have suggested that hip strategy should be observed in response to fast translations on a flat surface also, provided the feet are constrained to remain in contact with the floor and the knee is constrained to remain straight. The purpose of this study was to examine the experimental evidence for hip strategy in postural responses to backward translations of a flat support surface and to determine whether analyses of joint torques would provide evidence for two separate postural strategies. Normal subjects standing on a flat support surface were translated backward with a range of velocities from fast (55 cm/s) to slow (5 cm/s). EMG activations and joint kinematics showed pattern changes consistent with previous experimental descriptions of mixed hip and ankle strategy with increasing platform velocity. Joint torque analyses revealed the addition of a hip flexor torque to the ankle plantarflexor torque during fast translations. This finding indicates the addition of hip strategy to ankle strategy to produce a continuum of postural responses. Hip torque without accompanying ankle torque (pure hip strategy) was not observed. Although postural control strategies have previously been defined by how the body moves, we conclude that joint torques, which indicate how body movements are produced, are useful in defining postural control strategies. These results also illustrate how the biomechanics of the body can transform discrete control patterns into a continuum of postural corrections.

Non-NASA Center↗

Planetary Suit Hip Bearing Model for Predicting Design vs. Performance

Designing a planetary suit is very complex and often requires difficult trade-offs between performance, cost, mass, and system complexity. In order to verifying that new suit designs meet requirements, full prototypes must eventually be built and tested with human subjects. Using computer models early in the design phase of new hardware development can be advantageous, allowing virtual prototyping to take place. Having easily modifiable models of the suit hard sections may reduce the time it takes to make changes to the hardware designs and then to understand their impact on suit and human performance. A virtual design environment gives designers the ability to think outside the box and exhaust design possibilities before building and testing physical prototypes with human subjects. Reductions in prototyping and testing may eventually reduce development costs. This study is an attempt to develop computer models of the hard components of the suit with known physical characteristics, supplemented with human subject performance data. Objectives: The primary objective was to develop an articulating solid model of the Mark III hip bearings to be used for evaluating suit design performance of the hip joint. Methods: Solid models of a planetary prototype (Mark III) suit s hip bearings and brief section were reverse-engineered from the prototype. The performance of the models was then compared by evaluating the mobility performance differences between the nominal hardware configuration and hardware modifications. This was accomplished by gathering data from specific suited tasks. Subjects performed maximum flexion and abduction tasks while in a nominal suit bearing configuration and in three off-nominal configurations. Performance data for the hip were recorded using state-of-the-art motion capture technology. Results: The results demonstrate that solid models of planetary suit hard segments for use as a performance design tool is feasible. From a general trend perspective, the suited performance trends were comparable between the model and the suited subjects. With the three off-nominal bearing configurations compared to the nominal bearing configurations, human subjects showed decreases in hip flexion of 64%, 6%, and 13% and in hip abduction of 59%, 2%, and 20%. Likewise the solid model showed decreases in hip flexion of 58%, 1%, and 25% and in hip abduction of 56%, 0%, and 30%, under the same condition changes from the nominal configuration. Differences seen between the model predictions and the human subject performance data could be attributed to the model lacking dynamic elements and performing kinematic analysis only, the level of fit of the subjects with the suit, the levels of the subject s suit experience.

Cowley, Matthew S.↗

Sintering and properties of Si3N4 with and without additives by HIP treatment

Hot Isostatic Pressing (HIP) of Si3N4 powders with and without additives was performed using a glass container, and various kinds of pressureless-sintered Si3N4 were HIP'ed without a container. The effects of HIP treatment on density, microstructure, flexural strength, microhardness, and fracture toughness on Si3N4 ceramics were studied. Using a glass container it was difficult to reach theoretical density. The microhardness of HIP'ed Si3N4 without additives was low, and the fracture toughness of HIP'ed Si3N4 with and without additives was 22 to 25 W/m-K, and it decreased with increasing the amount of additives. The density and flexural strength, and hardness of pressureless-sintered Si3N4 which contained Al2O and Y2O3 as oxide additives were remarkably improved by HIP treatment using nitrogen as a pressure transmitting gas. It is very important to select the sintering conditions for fabricating the presintered body of Si3N4 in order to improve the mechanical properties of Si3N4 by HIP treatment.

Kuratani, S.↗

Creep-Fatigue Properties of Additional 316H PM-HIP Materials Fabricated from Different Powder Compositions and Processing Routes

The process of powder metallurgy (PM) hot isostatic pressing (HIP) works by consolidating powdered materials at relatively high temperature and pressure to form near-net-shaped components. Ideally, PM-HIP production methods can reduce component lead time and improve designs for high-temperature reactors and/or microreactors. To introduce PM-HIP into Section III, Division 5 of the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, it is necessary to show adequate material properties regarding creep, high-temperature low-cycle fatigue, and creep fatigue. However, prior work has shown that the creep-fatigue cycles to failure for PM-HIP 316H stainless steel are greatly reduced compared to the conventional, wrought product. This work continued creep-fatigue analysis on a 316H stainless steel with lower oxygen and nitrogen contents and at different HIP parameters than previously analyzed. The objective was to better understand what is causing the reduced PM-HIP 316H performance so improvements can be made PM-HIP 316H creep-fatigue lifetimes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data Mining Activity for Bone Discipline: Calculating a Factor of Risk for Hip Fracture in Long-Duration Astronauts

The factor-of-risk (Phi), defined as the ratio of applied load to bone strength, is a biomechanical approach to hip fracture risk assessment that may be used to identify subjects who are at increased risk for fracture. The purpose of this project was to calculate the factor of risk in long duration astronauts after return from a mission on the International Space Station (ISS), which is typically 6 months in duration. The load applied to the hip was calculated for a sideways fall from standing height based on the individual height and weight of the astronauts. The soft tissue thickness overlying the greater trochanter was measured from the DXA whole body scans and used to estimate attenuation of the impact force provided by soft tissues overlying the hip. Femoral strength was estimated from femoral areal bone mineral density (aBMD) measurements by dual-energy x-ray absorptiometry (DXA), which were performed between 5-32 days of landing. All long-duration NASA astronauts from Expedition 1 to 18 were included in this study, where repeat flyers were treated as separate subjects. Male astronauts (n=20) had a significantly higher factor of risk for hip fracture Phi than females (n=5), with preflight values of 0.83+/-0.11 and 0.36+/-0.07, respectively, but there was no significant difference between preflight and postflight Phi (Figure 1). Femoral aBMD measurements were not found to be significantly different between men and women. Three men and no women exceeded the theoretical fracture threshold of Phi=1 immediately postflight, indicating that they would likely suffer a hip fracture if they were to experience a sideways fall with impact to the greater trochanter. These data suggest that male astronauts may be at greater risk for hip fracture than women following spaceflight, primarily due to relatively less soft tissue thickness and subsequently greater impact force.

Ellman, R.↗

Magnetic Resonance Imaging (MRI) to Assess Changes to Trabecular Microarchitecture (Trb µArch) of the Hip

BACKGROUND . Calculated loss rates in trabecular (Trb) volumetric bone mineral density (vBMD), in astronauts after return from 6-month long-duration (LD) spaceflight, are rapid relative to menopause-induced loss rates and could contribute to the observed lack of recovery. Perforations in the Trb bony struts, skeletal fragility and fractures [5] have been associated with the rapid rate of bone loss in women due to menopause. The more rapid loss rate observed in astronauts could be inducing similar, irreversible losses of trabecular connectivity as seen in cadaver studies of female skeletons. These changes are not detectable by DXA technology and would not be discovered in astronauts during scheduled, triennial DXA testing for primary osteoporosis. High-resolution-peripheral quantitative computed tomography (HR-pQCT) of the lower leg have detected losses in Trb vBMD (vBMD) and changes in Trb microarchitecture (µArch) in astronauts immediately following routine 6-month spaceflights and continuing in some individuals for 1 or more years postflight with no signs of recovery. Resolution of these microarchitectural changes by whole body QCT, especially in the deeply embedded hip bone, is prohibitive due to excessive and unsafe radiation exposures. While HR-pQCT has sufficient resolution to study Trb µArch at safe and lower radiation exposure testing is restricted only to the lower leg and wrist. Hence, a technology to detect detrimental changes to Trb µArch in astronauts, especially of the hip, is needed to inform type and timing of countermeasures to irreversible deficits (preflight, inflight and postflight). METHODS . This HRP-funded study (2023-2027) will verify the sensitivity of a protocol for MRI scanning (on a 3T Siemens Vida) to detect changes to hip Trb µArch in persons following spinal cord injury (SCI); skeletal immobilization below the spinal lesion will serve as an analog for non-weight-bearing during spaceflight. The study period has been extended by 1 yr due to delayed Richmond IRB approval in Y1. A 3T MRI protocol will characterize serial changes in hip Trb µArch in SCI patients from time of admission at the Richmond VA Medical Center to their scheduled annual exam 12-months later. SCI patients with age, sex, and physical characteristics like ISS astronauts will be consented. The ability of 3T MRI hip scan to discriminate loss of trabecular connectivity subjects with SCI will be compared to age- and sex-matched ambulatory controls. A comparison between HR-pQCT and MRI measurements at the ankle (distal tibia) of study subjects will also be performed. A modified DXA scan analysis (3D-Shaper) will also be verified as a potential method for monitoring concurrent changes in hip Trb bone over 12-month. SIGNIFICANCE . Deliverables: a surveillance method for assessing for irreversible losses of connectivity and how skeletal changes after LD spaceflight(s) would modify the terrestrial risk of primary osteoporosis.

Spinal Cord Injury↗

Magnetic Resonance Imaging (MRI) to Assess Changes to Trabecular Microarchitecture (Trb µArch) of the Hip

BACKGROUND . Calculated loss rates in trabecular (Trb) volumetric bone mineral density (vBMD), in astronauts after return from 6-month long-duration (LD) spaceflight, are rapid relative to menopause-induced loss rates and could contribute to the observed lack of recovery. Perforations in the Trb bony struts, skeletal fragility and fractures [5] have been associated with the rapid rate of bone loss in women due to menopause. The more rapid loss rate observed in astronauts could be inducing similar, irreversible losses of trabecular connectivity as seen in cadaver studies of female skeletons. These changes are not detectable by DXA technology and would not be discovered in astronauts during scheduled, triennial DXA testing for primary osteoporosis. High-resolution-peripheral quantitative computed tomography (HR-pQCT) of the lower leg have detected losses in Trb vBMD (vBMD) and changes in Trb microarchitecture (µArch) in astronauts immediately following routine 6-month spaceflights and continuing in some individuals for 1 or more years postflight with no signs of recovery. Resolution of these microarchitectural changes by whole body QCT, especially in the deeply embedded hip bone, is prohibitive due to excessive and unsafe radiation exposures. While HR-pQCT has sufficient resolution to study Trb µArch at safe and lower radiation exposure testing is restricted only to the lower leg and wrist. Hence, a technology to detect detrimental changes to Trb µArch in astronauts, especially of the hip, is needed to inform type and timing of countermeasures to irreversible deficits (preflight, inflight and postflight). METHODS . This HRP-funded study (2023-2027) will verify the sensitivity of a protocol for MRI scanning (on a 3T Siemens Vida) to detect changes to hip Trb µArch in persons following spinal cord injury (SCI); skeletal immobilization below the spinal lesion will serve as an analog for non-weight-bearing during spaceflight. The study period has been extended by 1 yr due to delayed Richmond IRB approval in Y1. A 3T MRI protocol will characterize serial changes in hip Trb µArch in SCI patients from time of admission at the Richmond VA Medical Center to their scheduled annual exam 12-months later. SCI patients with age, sex, and physical characteristics like ISS astronauts will be consented. The ability of 3T MRI hip scan to discriminate loss of trabecular connectivity subjects with SCI will be compared to age- and sex-matched ambulatory controls. A comparison between HR-pQCT and MRI measurements at the ankle (distal tibia) of study subjects will also be performed. A modified DXA scan analysis (3D-Shaper) will also be verified as a potential method for monitoring concurrent changes in hip Trb bone over 12-month. SIGNIFICANCE . Deliverables: a surveillance method for assessing for irreversible losses of connectivity and how skeletal changes after LD spaceflight(s) would modify the terrestrial risk of primary osteoporosis.

Risk Surveillance↗

Imaging of the hip joint. Computed tomography versus magnetic resonance imaging

The authors reviewed the applications and limitations of computed tomography (CT) and magnetic resonance (MR) imaging in the assessment of the most common hip disorders. Magnetic resonance imaging is the most sensitive technique in detecting osteonecrosis of the femoral head. Magnetic resonance reflects the histologic changes associated with osteonecrosis very well, which may ultimately help to improve staging. Computed tomography can more accurately identify subchondral fractures than MR imaging and thus remains important for staging. In congenital dysplasia of the hip, the position of the nonossified femoral head in children less than six months of age can only be inferred by indirect signs on CT. Magnetic resonance imaging demonstrates the cartilaginous femoral head directly without ionizing radiation. Computed tomography remains the imaging modality of choice for evaluating fractures of the hip joint. In some patients, MR imaging demonstrates the fracture even when it is not apparent on radiography. In neoplasm, CT provides better assessment of calcification, ossification, and periosteal reaction than MR imaging. Magnetic resonance imaging, however, represents the most accurate imaging modality for evaluating intramedullary and soft-tissue extent of the tumor and identifying involvement of neurovascular bundles. Magnetic resonance imaging can also be used to monitor response to chemotherapy. In osteoarthrosis and rheumatoid arthritis of the hip, both CT and MR provide more detailed assessment of the severity of disease than conventional radiography because of their tomographic nature. Magnetic resonance imaging is unique in evaluating cartilage degeneration and loss, and in demonstrating soft-tissue alterations such as inflammatory synovial proliferation.

Review↗

Powder Metallurgy HIP Process Study and Mechanical Property Evaluations for IN740H

The effects of hot isostatic pressing (HIP) parameters and powder size distribution (PSD) on the resulting microstructure and properties of powder metallurgy (P/M) IN740H have been investigated. Properties can be substantially tailored through the appropriate management of these parameters. Applying a thermal presoak to the input powder prior to the sintering stage of HIP can significantly increase average grain size and coarse grain fraction, enabling a trade for improved creep resistance at the expense of tensile strength. Here, powder thermal presoak was found to have a larger impact on microstructure and properties than the use of a coarser PSD alone. Additionally, substantial grain growth and grain boundary migration is observed in P/M IN740H at HIP temperatures above 1260°C. Given its inherently finer grain size, P/M HIP IN740H typically outperforms its cast and wrought counterparts in tensile response. Creep life at 700–800°C was inferior to wrought due to PPBs coincident with grain boundaries which served as cavity nucleation sites, leading to lower creep ductility. The ability to adjust the microstructure toward a more balanced creep and tensile behavior allows P/M HIP IN740H to be considered for high-temperature applications in advanced ultra-supercritical steam and supercritical carbon dioxide power cycles.

36 MATERIALS SCIENCE↗

Comparing structure-property evolution for PM-HIP and forged alloy 625 irradiated with neutrons to 1 dpa

The nuclear power industry has growing interest in qualifying powder metallurgy with hot isostatic pressing (PM-HIP) to replace traditional alloy fabrication methods for reactor structural components. But there is little known about the response of PM-HIP alloys to reactor conditions. This study directly compares the response of PM-HIP to forged Ni-base Alloy 625 under neutron irradiation doses ~0.5–1 displacements per atom (dpa) at temperatures ranging ~321–385 °C. Post-irradiation examination involves microstructure characterization, ASTM E8 uniaxial tensile testing, and fractography. Up through 1 dpa, PM-HIP Alloy 625 appears more resistant to irradiation-induced cavity nucleation than its forged counterpart, and consequently experiences significantly less hardening. This observed difference in performance can be explained by the higher initial dislocation density of the forged material, which represents an interstitial-biased sink that leaves a vacancy supersaturation to nucleate cavities. These findings show promise for qualification of PM-HIP Alloy 625 for nuclear applications, although higher dose studies are needed to assess the steady-state irradiated microstructure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Net-Shape HIP Powder Metallurgy Components for Rocket Engines

True net shape consolidation of powder metal (PM) by hot isostatic pressing (HIP) provides opportunities for many cost, performance and life benefits over conventional fabrication processes for large rocket engine structures. Various forms of selectively net-shape PM have been around for thirty years or so. However, it is only recently that major applications have been pursued for rocket engine hardware fabricated in the United States. The method employs sacrificial metallic tooling (HIP capsule and shaped inserts), which is removed from the part after HIP consolidation of the powder, by selective acid dissolution. Full exploitation of net-shape PM requires innovative approaches in both component design and materials and processing details. The benefits include: uniform and homogeneous microstructure with no porosity, irrespective of component shape and size; elimination of welds and the associated quality and life limitations; removal of traditional producibility constraints on design freedom, such as forgeability and machinability, and scale-up to very large, monolithic parts, limited only by the size of existing HIP furnaces. Net-shape PM HIP also enables fabrication of complex configurations providing additional, unique functionalities. The progress made in these areas will be described. Then critical aspects of the technology that still require significant further development and maturation will be discussed from the perspective of an engine systems builder and end-user of the technology.

Bampton, Cliff↗

Isochronal Age-mass Discrepancy of Young Stars: SCExAO/CHARIS Integral Field Spectroscopy of the HIP 79124 Triple System

We present SCExAO/CHARIS 1.1-2.4 μm integral field direct spectroscopy of the young HIP 79124 triple system. HIP 79124 is a member of the Scorpius-Centaurus association, consisting of an A0V primary with two low-mass companions at a projected separation of < 1″. Thanks to the high quality wavefront corrections provided by SCExAO, both companions are decisively detected without the employment of any PSF-subtraction algorithm to eliminate quasi-static noise. The spectrum of the outer C object is very well matched by Upper Scorpius M4 ± 0.5 standard spectra, with a T(eff) = 2945 ± 100 K and a mass of ∼350 M(Jup). HIP 79124 B is detected at a separation of only 180 mas in a highly-correlated noise regime, and it falls in the spectral range M6 ± 0.5 with T(eff) = 2840 ± 190 K and ∼100 M(Jup). Previous studies of stellar populations in Sco-Cen have highlighted a discrepancy in isochronal ages between the lower-mass and higher-mass populations. This could be explained either by an age spread in the region, or by conventional isochronal models failing to reproduce the evolution of low-mass stars. The HIP 79124 system should be coeval, and therefore it provides an ideal laboratory to test these scenarios. We place the three components in a color-magnitude diagram and find that the models predict a younger age for the two low-mass companions (∼3 Myr) than for the primary star (∼6 Myr). These results imply that the omission of magnetic effects in conventional isochronal models inhibit them from reproducing early low-mass stellar evolution, which is further supported by the fact that new models that include such effects provide more consistent ages in the HIP 79124 system.

Ruben Asensio-Torres↗

MRP: Qualification of Powder Metallurgy Hot Isostatic Pressed (PM HIP) Materials for Elevated-Temperature Nuclear Construction

PM HIP is a mature technology that offers many advantages that are attractive to the microreactor industry. The elevated-temperature creep-fatigue properties of the PM HIP 316H SS bar that has been characterized are reduced compared to the wrought material. Work will be carried out in fiscal year 2022 to identify the mechanisms responsible for the reduced creep-fatigue properties. Confirmatory testing of optimized material will be conducted to demonstrate long-term PM HIP properties comparable to the wrought-product form. The lessons learned for PM HIP 316H SS will be applied to the procurement and confirmatory testing of PM HIP Alloy 800H.

316H stainless steel↗

A comparison of plastic and visco-plastic constitutive models for accurate predictions in PM-HIP

Powder metallurgy hot isostatic pressing (PM-HIP) is an advanced manufacturing process that can efficiently produce near net shape parts with high material utilization and uniform microstructures. While the PM-HIP process is used frequently to produce small-scale components, its application to large-scale components is still limited due to inadequate understanding of its complex processes that cause unpredictable post-HIP shape distortions. A computational model can be a cost-effective alternative to exhaustive experimentation required to understand the PM-HIP process fully. Therefore, we present a comparison of plastic and visco-plastic models that are frequently used to model the PM-HIP process. We show that the predictions of powder densification behavior and shape distortions obtained from both the models are similar under most conditions and agree well with experimental observations.

Sarkar, Subrato [ORNL]↗

Experiment design for the neutron irradiation of $\mathrm{PM-HIP}$ alloys for nuclear reactors

Here, this article describes the design of an Advanced Test Reactor (ATR) drop-in neutron irradiation experiment aiming to directly compare the performance of nuclear structural alloys fabricated by powder metallurgy with hot isostatic pressing (PM-HIP) against conventional casting or forging. There is growing interest in PM-HIP alloys for nuclear applications because of their microstructural uniformity, superior mechanical properties, and reduced dependence on welding and machining, compared to cast/forged alloys. Nuclear code-qualification of PM-HIP alloys requires neutron irradiation testing to demonstrate performance under relevant conditions. In this experiment, six nuclear structural alloys were irradiated: Ni-based alloys 625 and 690, Grade 91 ferritic steel, SA508 pressure vessel steel, and 304L and 316L austenitic stainless steels. The experiment is assembled into seven capsules in four test trains and irradiated in three ATR inboard A positions. Both the PM-HIP and cast/forged versions of each alloy were irradiated under nearly identical conditions for comparative purposes, to target doses of 1 ± 0.2 and 3 ± 0.2 dpa at temperatures of 300 ± 50 °C and 400 ± 50 °C. A thorough description of the experiment design and thermal, structural and neutronic analyses performed to ensure the targeted irradiation conditions are met is provided. Specimens were configured as small disks, compact tension specimens and tensile bars to facilitate post-irradiation examination (PIE) that will include mechanical testing, microstructure characterization, and fracture toughness testing. Given the considerations for ASTM standardized mechanical testing, comparative fluence and temperature across specimen pairs, and comprehensive PIE planning herein, this work serves as a template for future nuclear materials qualification experiment designs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗