Search NASA⌕ Search

SEARCH · Search NASA

Results for “HOLMIUM 140”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

Nuclear Data Sheets for A=140☆

The 2006 evaluation of A=140 was updated using experimental results published before November 2018 from the various reaction and decay studies leading to the nuclei {sup 140}Sb, {sup 140}Te, {sup 140}I, {sup 140}Xe, {sup 140}Cs, {sup 140}Ba, {sup 140}La, {sup 140}Ce, {sup 140}Pr, {sup 140}Nd, {sup 140}Pm, {sup 140}Sm, {sup 140}Eu, {sup 140}Gd, {sup 140}Tb, {sup 140}Dy, {sup 140}Ho. These data are summarized and presented, together with adopted level schemes and properties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Potential of high-Z contrast agents in clinical contrast-enhanced computed tomography

Purpose: Currently, only iodine- and barium-based contrast media (CM) are used in clinical contrast-enhanced computed tomography (CE-CT). High-Z metals would produce a higher contrast at equal mass density for the x-ray spectra used in clinical CT. Using such materials might allow for significant dose reductions in CE-CT. The purpose of this study was to quantify the potential for dose reduction when using CM based on heavy metals. Methods: The contrast-to-noise ratio weighted by dose (CNRD) was determined as a function of scan protocol by means of measurements and simulations on a clinical CT scanner. For simulations, water cylinders with diameters 160, 320, 480, and 640 mm were used to cover a broad range of patient sizes. Measurements were conducted with 160 and 320 mm water-equivalent plastic cylinders. A central bore of 13 mm diameter was present in all phantoms. The tube voltage was varied from 80 to 140 kV for measurements and from 60 to 180 kV for simulations. Additional tin filtration of thicknesses 0.4, 0.8, and 1.2 mm was applied in the simulation to evaluate a range of spectral hardness. The bore was filled with a mixture of water and 10 mg/ml of pure iodine, holmium, gadolinium, ytterbium, osmium, tungsten, gold, and bismuth for the simulations and with aqueous solutions of ytterbium, tungsten, gold, and bismuth salts as well as Iopromid containing 10 mg/ml of the pure materials for the measurements. CNRDs were compared to iodine at phantom size-dependent reference voltages for all high-Z materials and the resulting dose reduction was calculated for equal contrast-to-noise ratio. Results: Dose reduction potentials strongly depended on phantom size, spectral hardness, and tube voltage. Depending on the added filtration, a dose reduction of 19%-60% could be reached at 80 kV with gadolinium for the 160 mm phantom, 52%-69% at 100 kV with holmium for the 320 mm phantom, 62%-78% with 120 kV for hafnium and the 480 mm phantom and 74%-86% with 140 kV for gold and the 640 mm phantom. While gadolinium might be considered at 160 mm diameter, hafnium showed the best overall performance for phantom sizes of 320 mm and above. The measurements conducted on the clinical CT scanner showed very good agreement with simulations with deviations in the order of 5 to 10%. Conclusions: The results of this study encourage the development and use of CM based on high-Z materials, especially for adipose patients, where high tube voltages are necessary to reach sufficiently short scan times. Hafnium proved to be the best compromise for average-size and for adipose patients. Even higher-Z materials such as gold and bismuth showed a good overall performance in conjunction with high tube voltage, large patients or strong added filtration and may be recommended for scans under these conditions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Frequency Swept Diode-pumped Single Frequency TM,Ho:YLiF Laser for spaceborne Doppler Lidar

Optical heterodyne experiments involving the photomixing of two single frequency, deode-pumped thulium holmium yttrium lithium flouride lasers are described. Operated in external frquency stabilization loops, the lasers exhibit 1MHz short term stability, and are photomixed and offset-locked at 140 MHz. Summation of sine wave modulation onto the PZT control voltage on one laser results in frequency swept operation over a continuous tuning range of 160 MHz.

Doppler Lidar Optical heterodyne experiments↗

Comparative Study of the Magnetoelectric Effect in HoAl{sub 3}(BO{sub 3}){sub 4} and HoGa{sub 3}(BO{sub 3}){sub 4} Single Crystals

The comparative study of the magnetoelectric properties and magnetostriction of HoGa{sub 3}(BO{sub 3}){sub 4} and HoAl{sub 3}(BO{sub 3}){sub 4} single crystals has been carried out. The investigated compounds exhibit qualitatively similar magnetodielectric and inverse magnetoelectric ME{sub E} effects with the close absolute values, which is indicative of the weak effect of a nonmagnetic metal ion. On the contrary, the magnetostriction of the galloborate has been found to be threefold higher than that of the alumoborate. In addition, the difference between the qualitative behaviors of magnetostriction has been established: the magnetic-field dependence of magnetostriction for the alumoborate has the maximum near 70 kOe at T = 4.2 K, while the galloborate magnetostriction has no maximum and does not saturate in a field of 140 kOe.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enhancement in magnetocaloric properties of holmium chromite by gadolinium substitution

HoCrO{sub 3}, Ho{sub 0.67}Gd{sub 0.33}CrO{sub 3}, and GdCrO{sub 3} bulk powder samples were prepared by citrate route. The phase purity and the structural properties of the samples were examined by x-ray diffraction and Raman spectroscopic measurements. The dc magnetization data revealed that the Cr{sup 3+} ordering temperatures (Néel temperature) for the HoCrO{sub 3}, Ho{sub 0.67}Gd{sub 0.33}CrO{sub 3}, and GdCrO{sub 3} samples are 140 K, 148 K, and 167 K, respectively, while the ac magnetization data revealed that the rare-earth (Ho) ordering occurs at ∼8 K for HoCrO{sub 3} and Ho{sub 0.67}Gd{sub 0.33}CrO{sub 3} samples. Temperature-induced magnetization reversal and spin reorientation were observed in GdCrO{sub 3} bulk sample, which depends on applied magnetic field and disappears at ∼1500 Oe and 500 Oe, respectively. By fitting the dc magnetic data with Curie-Weiss law, the effective magnetic moments were calculated to be 11.66 μ{sub B}, 10.23 μ{sub B}, and 9.90 μ{sub B} for the HoCrO{sub 3}, Ho{sub 0.67}Gd{sub 0.33}CrO{sub 3}, and GdCrO{sub 3} samples, respectively. The isothermal magnetization data showed that the magnetic behavior changed from canted antiferromagnetic in low temperature region (below Néel temperature) to paramagnetic at high temperature. It was found that Gd substitution considerably improves the magnetocaloric effect of HoCrO{sub 3}. Pure GdCrO{sub 3} bulk sample showed giant magnetocaloric entropy change (31.6 J/kg K at temperature ∼5 K and at ∼70 kOe), which is higher than that for polycrystalline RMnO{sub 3}, RCrO{sub 3}, and RFeO{sub 3} bulk powder samples. This renders GdCrO{sub 3} useful for potential applications in low-temperature magnetic refrigeration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic and magnetocaloric properties of iron subs tituted holmium chromite and dysprosium chromite

In this work, structural, magnetic, and magnetocaloric properties of HoCrO 3 and Fe substituted HoCrO 3 and DyCrO 3 (i.e. HoCr 0.7 Fe 0.3 O 3 and DyCr 0.7 Fe 0.3 O 3 ) powder samples were synthesized via a solution route. The structural properties of the samples were examined by Raman spectroscopy and x-ray diffraction techniques, which were further confirmed using first-principle calculations. The dc magnetic measurements indicate that the Cr 3+ ordering temperatures for the HoCrO 3 , HoCr 0.7 Fe 0.3 O 3 , and DyCr 0.7 Fe 0.3 O 3 samples are 140 K, 174 K, and 160 K, respectively. The ac magnetic measurements not only confirmed the Cr 3+ ordering transitions in these samples (obtained using dc magnetic measurements), but also clearly showed the Ho 3+ ordering at ~10 K in the present HoCrO 3 and HoCr 0.7 Fe 0.3 O 3 samples, which to our knowledge, is the first ac magnetic evidence of Ho 3+ ordering in this system. The effective magnetic moments were determined to be 11.67μB, 11.30μB, and 11.27μB for the HoCrO 3 , HoCr 0.7 Fe 0.3 O 3 , and DyCr 0.7 Fe 0.3 O 3 samples, respectively. For the first time, the magnetocaloric properties of HoCrO 3 and HoCr 0.7 Fe 0.3 O 3 were studied here, showing their potential for applications in magnetic refrigeration. In an applied dc magnetic field of 7 T, the maximum magnetocaloric value were determined to be 7.2 (at 20 K), 6.83 (at 20 K), 13.08 J/kg K (at 5 K) and the relative cooling power were 408, 387, and 500 J/kg for the HoCrO 3 , HoCr 0.7 Fe 0.3 O 3 , and DyCr 0.7 Fe 0.3 O 3 samples, respectively.

36 MATERIALS SCIENCE↗

Fission studies with 140 MeV {alpha} particles

Binary fission induced by 140 MeV {alpha} particles has been measured for {sup nat}Ag, {sup 139}La, {sup 165}Ho, and {sup 197}Au targets. The measured quantities are the total kinetic energies, fragment masses, and fission cross sections. The results are compared with other data and systematics. A minimum of the fission probability in the vicinity Z{sup 2}/A=24 is observed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗