Search NASA⌕ Search

SEARCH · Search NASA

Results for “HPLC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Efficient Synthesis and HPLC-Based Characterization for Developing Vanadium-48-Labeled Vanadyl Acetylacetonate as a Novel Cancer Radiotracer for PET Imaging

Bis(acetylacetonato)oxidovanadium(IV) [(VO(acac) 2 ], generally known as vanadyl acetylacetonate, has been shown to be preferentially sequestered in malignant tissue. Vanadium-48 ( 48 V) generated with a compact medical cyclotron has been used to label VO(acac) 2 as a potential radiotracer in positron emission tomography (PET) imaging for the detection of cancer, but requires lengthy synthesis. Current literature protocols for the characterization of VO(acac) 2 require macroscale quantities of reactants and solvents to identify products by color and to enable crystallization that are not readily adaptable to the needs of radiotracer synthesis. We present an improved method to produce vanadium-48-labeled VO(acac) 2 , [ 48 V]VO(acac) 2 , and characterize it using high-performance liquid chromatography (HPLC) with radiation detection in combination with UV detection. The approach is suitable for radiotracer-level quantities of material. These methods are readily applicable for production of [ 48 V]VO(acac) 2 . Preliminary results of preclinical, small-animal PET studies are presented.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

HPLC-Parallel accelerator and molecular mass spectrometry analysis of 14 C-labeled amino acids

Accelerator mass spectrometry (AMS) is the method of choice for quantitation of low amounts of 14 C-labeled biomolecules. Despite exquisite sensitivity, an important limitation of AMS is its inability to provide structural information about the analyte. This limitation is not critical when the labeled compounds are well-characterized prior to AMS analysis. However, analyte identity is important in other experiments where, for example, a compound is metabolized and the structures of its metabolites are not known. We previously described a moving wire interface that enables direct AMS measurement of liquid sample in the form of discrete drops or HPLC eluent without the need for individual fraction collection, termed liquid sample-AMS (LS-AMS). Here, we now report the coupling of LS-AMS with a molecular mass spectrometer, providing parallel accelerator and molecular mass spectrometry (PAMMS) detection of analytes separated by liquid chromatography. The repeatability of the method was examined by performing repeated injections of 14 C-labeled tryptophan, and relative standard deviations of the 14 C peak areas were ≤10.57% after applying a normalization factor based on a standard. Five 14 C-labeled amino acids were separated and detected to provide simultaneous quantitative AMS and structural MS data, and AMS results were compared with solid sample-AMS (SS-AMS) data using Bland-Altman plots. To demonstrate the utility of the workflow, yeast cells were grown in a medium with 14 C-labeled tryptophan. The cell extracts were analyzed by PAMMS, and 14 C was detected in tryptophan and its metabolite kynurenine.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Analysis of TATB by HPLC-DAD (V.1.4)

The following procedure describes the method for determining the purity of 1,3,5-triamino 2,4,6-trinitrobenzene (TATB) samples using a High-Performance Liquid Chromatography (HPLC) system fitted with a Diode Array Detector (DAD). This procedure is also applicable for the detection of some impurities present in TATB.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Production and purification of research scale 161 Tb using cation-exchange semi-preparative HPLC for radiopharmaceutical applications

Terbium-161 ( 161 Tb) is emerging as a promising radionuclide for cancer therapy due to its favorable nuclear properties that are similar to clinically established lutetium-177 ( 177 Lu) along with its therapeutic edge arising from the higher number of Auger and conversion electrons per decay. These low energy electrons result in higher cytotoxicity within a short range of the decaying nuclei to enhance therapeutic efficacy. Despite these promising characteristics, a significant challenge remains in the lack of a domestic 161 Tb supply in the United States, which poses an obstacle to the advancement of 161 Tb-based radiopharmaceutical research and development. Here, this study developed a reliable cation-exchange high-performance liquid chromatography-based method for purification of reactor-produced 161 Tb at quantities suitable to support research and preclinical studies. The purified 161 Tb product showed high radionuclidic purity with excellent radiochemical purity, and the successful labeling studies with the DOTA chelator and DOTA-TATE peptide demonstrated the effective incorporation of the purified 161 Tb into radiopharmaceuticals designed for targeted cancer therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of Seven Organic Impurities in FD&C Yellow No. 6 by Ultra-High-Performance Liquid Chromatography

The U.S. Food and Drug Administration (FDA) batch certifies FD&C Yellow No. 6 (Y6) to ensure that the color additive meets requirements published in the Code of Federal Regulations (CFR), including specifications for seven organic manufacturing impurities consisting of two intermediates, a reaction by-product, an impurity originating from an intermediate, and three subsidiary colors. An ultra-high-performance liquid chromatography (UHPLC) method was developed and validated for determining seven organic impurities in Y6. For comparison, the currently used high-performance liquid chromatography (HPLC) method was also validated. The new UHPLC method uses a 1.7 µm particle size biphenyl column with aqueous ammonium formate and methanol as eluants. Analytes are identified by comparing their retention times and UV-visible spectra to those of reference standards. Calibration is performed in the presence of the dye matrix and analyte levels are determined from their peak areas. UHPLC and HPLC validation studies obtained linear calibration curves and excellent values for limits of detection, limits of quantitation, recovery, repeatability, and intermediate precision for all analytes. Survey analyses of 30 samples using the UHPLC and HPLC methods yielded results that were consistent within experimental error; however, the UHPLC method provided more accurate results for two analytes that coelute using the HPLC method. The UHPLC method satisfies the accuracy and precision requisites for routine certification of Y6. The UHPLC method is faster and generates less waste than the HPLC method while delivering better sensitivity, separation, and accuracy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Linking chemical precursors to the synthesis of erythritol tetranitrate

Erythritol tetranitrate (ETN) is a homemade explosive with high explosive performance which can easily be synthesized using widely available chemical precursors. Ascertaining the manner in which ETN is synthesized and being able to trace the ETN back to its precursor materials may aid in the forensic identification. As a proof of concept, seven different types of ETN were synthesized with laboratory grade materials as well as commercially available chemicals from the hardware store and grocery store. The seven different types of solid ETN and the reaction quenches were analyzed using high performance liquid chromatography (HPLC). Partial least squares discriminant analysis (PLS-DA) was used to probe the different classes of ETN and reaction quenches. Several PLS-DA models were produced with the seven different types of ETN and quenches having their own classification, ETN and quenches based on their acid source, and ETN and the quenches based on their nitrate source. Regardless of which classification manner was used, there were no differences found between the different types of ETN or their reaction quenches. Furthermore, it is demonstrated that there is inherent variability in the synthesis of ETN making HPLC an unreliable method to determine the source of the synthesis materials. Elemental impurities were measured in seven solid ETN samples and their reaction quenches by inductively coupled plasma mass spectrometry (ICP-MS). No differences were discovered between the solid ETN samples, but there were trace metals found in the reaction quenches which were found to be identifiers of the source material.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exploring Fluoropyridine Electrolytes in Li–S Batteries: Balancing Performance and Stability across Temperatures

A novel high-donor 3-fluoropyridine (3FPy) electrolyte has been introduced for use in Li-S batteries, demonstrating an inhibition effect on the polysulfide shuttle, even without the addition of LiNO 3 . In this study, fluoropyridine electrolytes, including 2-fluoropyridine (2FPy) and 3FPy electrolytes, are studied using electrochemical analysis, mass spectrometry (MS), and high-performance liquid chromatography (HPLC) methods. Collision-induced dissociation spectra revealed that Li + preferentially solvates with different fluoropyridines, with 2FPy exhibiting a stronger interaction due to ortho-fluorine's influence, compared to 4FPy and 3FPy. However, MS and HPLC analyses showed that 2FPy is reactive with polysulfides, while 3FPy offers high solubility for polysulfides and sulfur without reacting with them at room temperature. Further, despite 3FPy performing well at room temperature, further electrochemistry studies at elevated (60 °C) and reduced (0 °C) temperatures reveal the challenges. At high temperatures, LiNO 3 is essential to suppress the polysulfide shuttle; and at low temperatures, the performance with the 3FPy electrolyte significantly lags behind that of the ether-based electrolyte.

25 ENERGY STORAGE↗

Thorium chelators for targeted alpha therapy: Rapid chelation of thorium-226

We report one of the main challenges in targeted alpha therapy is assuring delivery of the α-particle dose to the targeted cells. Thus, it is critical to identify ligands for α-emitting radiometals that will form complexes that are very stable, both in vitro and in vivo. In this investigation, thorium-227 (t 1/2 = 18.70 days) chelation of ligands containing hydroxypyridinonate (HOPO) or picolinic acid (pa) moieties and the stability of the resultant complexes were studied. Chelation reactions were followed by reversed-phased HPLC and gamma spectroscopy. Studies revealed that high 227 Th chelation yields could be obtained within 2.5 h or less with ligands containing four Me-3,2-HOPO moieties, 1 (83%) and 2 (65%), and also with ligands containing pa moieties, H 4 octapa 3 (65%) and H 4 py4pa 6 (87%). No reaction occurred with H 4 neunpa-p-Bn-NO 2 4, and the chelation reaction with another pa ligand H 4 pypa 5 gave inconsistent yields with a very broad radio-HPLC peak. The ligands spermine-(Me-3,2-HOPO) 4 1, H 4 octapa 3, and H 4 py4pa 6 had high stability (i.e., 87% of 227 Th still bound to the ligand) in phosphate-buffered saline at room temperature over a 6-day period. Preliminary studies with ligand 6 demonstrated efficient chelation of thorium-226 (t 1/2 = 30.57 min) when heated to 80°C for 5 min.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrating phytoplankton pigment and DNA meta-barcoding observations to determine phytoplankton composition in the coastal ocean

Quantifying phytoplankton composition is critical to predicting marine ecosystem structure and function. DNA meta-barcoding and high-performance liquid chromatography (HPLC) pigment analysis are two widely used methods for assessing phytoplankton composition; however, comparing their performance has been done only rarely. Here, we integrate DNA meta-barcoding and HPLC pigment observations to determine eukaryotic phytoplankton composition in the Santa Barbara Channel, California. We find that both methods identify the same four dominant eukaryotic phytoplankton taxa (diatoms, dinoflagellates, chlorophytes, and prymnesiophytes), but inter- and intra-lineage variability in biomarker pigmentation (associated with both a lack of taxonomic specificity of biomarker pigments and intrinsic differences in accessory pigmentation) drives substantial disagreement between the methods. Covariation network analysis circumvents this disagreement and reveals that diverse assemblages of phytoplankton and other protists covary with distinct suites of biomarker pigments. Our results highlight the strengths and weaknesses of each method in characterizing phytoplankton composition and reveal novel insights into phytoplankton physiology that could only be gained by integrating the two methods. Finally, we suggest a path to monitor eukaryotic plankton communities on unprecedented spatiotemporal scales based on the covariation of unique phytoplankton and protistan assemblages with remotely sensible phytoplankton pigment concentrations.

59 BASIC BIOLOGICAL SCIENCES↗

147 Nd Quantification Using HSCCC-Purified Samples

Quantifying the fission product 147 Nd in nuclear debris samples is an important component of post-detonation nuclear forensics. The most accurate quantifications are obtained when Nd is purified from all other fission products, actinides, activation products, and environmental matrix contained within the debris. In this study, a recently developed method for Nd purification was tested, purifying 147 Nd from solutions of mixed fission products using high-speed counter-current chromatography (HSCCC). Importantly, the new method allowed for faster elution of Nd from the column as compared with established high performance liquid chromatography (HPLC) methods, and resulted in accurate/precise 147 Nd quantification by gamma-ray spectrometry. While the up-front equipment costs associated with HSCCC may be higher, its operational costs are on par with those of HPLC (solvents, extractants, power). Gas-flow proportional beta decay counting revealed contamination from the nearest neighbor lanthanide 143 Pr (a gamma-silent radioisotope) in the HSCCC-purified samples, but the activity contribution from 147 Nd could still be quantified. Remarkably consistent elution profiles were observed for the HSCCC method, spanning rare earth element (REE) loadings of more than 10 orders of magnitude (tracer to mmol quantities). In conclusion, the reliability and speed of the new method suggest utility for the rapid separation and quantification of 147 Nd in unknown samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular Characterization of Water-Soluble Brown Carbon Chromophores in Snowpack from Northern Xinjiang, China

This study reports molecular-level characterization of brown carbon (BrC) attributed to water-soluble organic carbon in six snowpack samples collected from northern Xinjiang, China. Here, the molecular composition and light-absorbing properties of BrC chromophores were unraveled by application of high-performance liquid chromatography (HPLC) coupled to a photodiode array (PDA) detector and high-resolution mass spectrometry. The chromophores were classified into five major types, that is, (1) phenolic/lignin-derived compounds, (2) flavonoids, (3) nitroaromatics, (4) oxygenated aromatics, and (5) other chromophores. Identified chromophores account for ~23–64% of the total light absorption measured by the PDA detector in the wavelength range of 300–370 nm. In the representative samples from urban and remote areas, oxygenated aromatics and nitroaromatics dominate the absorption in the wavelengths below and above 320 nm, respectively. The highly polluted urban sample shows the most complex HPLC-PDA chromatogram, and more other chromophores contribute to the bulk absorption. Phenolic/ lignin-derived compounds are the most light-absorbing species in the soil-influenced sample. Chromophores in two remote samples exhibit ultraviolet–visible features distinct from other samples, which are attributed to flavonoids. Identification of individual chromophores and quantitative analysis of their optical properties are helpful for elucidating the roles of BrC in snow radiative balance and photochemistry.

54 ENVIRONMENTAL SCIENCES↗

A Unified Analytical Method Greenness Score ( uAMGS ) Quantifies How Microscopic Imaging Is Greener Than Conventional Liquid Chromatography

Green chemistry is a set of principles for assessing, developing, and implementing methods that are safer, more efficient, and less detrimental to the environment. The analytical method greenness score (AMGS) is one of many metrics that attempt to evaluate traditional liquid chromatography (LC) based on the energy consumption of the instrument and the safety, health risks, and environmental impact of the solvents employed. Unfortunately, in practice, the AMGS is primarily focused on traditional separation methods in the pharmaceutical industry and is not amenable to cutting-edge separation science, including miniaturization. To broaden this scope, the unified Analytical Method Greenness Score (uAMGS) is presented here, which clarifies and expands on the underlying mathematics and incorporates both dimensional and uncertainty analysis, enabling its application to a broader range of analytical techniques. The uAMGS is used to compare the greenness of two distinct methods: single-molecule microscopy (SMM) and high-performance liquid chromatography (HPLC), which were used to collect equivalent data. uAMGS determines that SMM is significantly greener than HPLC due primarily to decreased solvent consumption. Overall, the uAMGS should allow chemists ranging from undergraduates to industrial PhDs to assess the greenness of a wide range of separations.

chemical separations↗

Radiation-Induced Effects on the Extraction Properties of Hexa-n-octylnitrilo-triacetamide (HONTA) Complexes of Americium and Europium

The candidate An(III)/Ln(III) separation ligand hexa-n-octylnitrilo-triacetamide (HONTA) was irradiated under envisioned SELECT (Solvent Extraction from Liquid waste using Extractants of CHON-type for Transmutation) process conditions (n-dodecane/0.1 M HNO 3 ) using a solvent test loop in conjunction with cobalt-60 gamma irradiation. The extent of HONTA radiolysis and complimentary degradation product formation was quantified by HPLC-ESI-MS/MS. Further, the impact of HONTA radiolysis on process performance was evaluated by measuring the change in 243 Am and 154 Eu distribution ratios as a function of absorbed gamma dose. HONTA was found to decay exponentially with increasing dose, affording a dose coefficient of d = (4.48 ± 0.19) × 10 –3 kGy –1 . Multiple degradation products were detected by HPLC-ESI-MS/MS with dioctylamine being the dominant quantifiable species. Both 243 Am and 154 Eu distribution ratios exhibited an induction period of ~70 kGy for extraction (0.1 M HNO 3 ) and back-extraction (4.0 M HNO 3 ) conditions, after which both values decreased with absorbed dose. The decrease in distribution ratios was attributed to a combination of the destruction of HONTA and ingrowth of dioctylamine, which is capable of interfering in metal ion complexation. Furthermore, the loss of HONTA with absorbed gamma dose was predominantly attributed to its reaction with the n-dodecane radical cation (R˙ + ). These R˙ + reaction kinetics were measured for HONTA and its 241 Am and 154 Eu complexes using picosecond pulsed electron radiolysis techniques. All three second-order rate coefficients (k) were essentially diffusion limited in n-dodecane indicating a significant reaction pathway: k(HONTA + R˙ + ) = (7.6 ± 0.8) × 10 9 M –1 s –1 , k(Am(HONTA) 2 + R˙ + ) = (7.1 ± 0.7) × 10 10 M –1 s –1 , and k(Eu(HONTA) 2 + R˙ + ) = (9.5 ± 0.5) × 10 10 M –1 s –1 . HONTA-metal ion complexation afforded an order-of-magnitude increase in rate coefficient. Additional nanosecond time-resolved measurements showed that both direct and indirect HONTA radiolysis yielded the short-lived (< 100 ns) HONTA radical cation and a second long-lived (µs) species identified as the HONTA triplet excited state. The latter was confirmed by a series of oxygen quenching picosecond pulsed electron measurements, affording a quenching rate coefficient of k( 3 [HONTA]* + O 2 ) = 2.2 × 10 8 M –1 s –1 . Overall, both the HONTA radical cation and triplet excited state are important precursors to the suite of measured HONTA degradation products.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Development of a continuous synthesis process for carbamazepine using validated in-line Raman spectroscopy and kinetic modelling for disturbance simulation

Mitigation of failure modes in the continuous synthesis (CS) of a drug substance (DS) has the potential to widen the adoption of continuous manufacturing (CM) technologies by the pharmaceutical industry. Here, this work demonstrates the development of a robust continuous process for the synthesis of carbamazepine (CBZ), an essential medicine as per the World Health Organization (WHO), facilitated by kinetic modelling and monitored by in-line Raman spectroscopy. Accurate kinetic modelling and the use of validated process analytical technology (PAT) models for quantitative measurement were found to play an important role in developing CS of drug substances. Kinetic data for the formation of CBZ from iminostilbene (ISB) were collected by batch reaction sampling and high-performance liquid chromatography (HPLC) analysis. A non-linear solver and iterative method was applied to determine two sets of Arrhenius parameters simultaneously for the reaction system by minimizing the standard error of the model fit. The start-up and dynamic equilibrium stages for the CS of CBZ using a continuous stirred tank reactor (CSTR) were modelled based on the batch kinetic data and employed to optimize conversion and simulate process disturbances. An in-line Raman spectroscopy method was successfully developed, validated, and integrated to determine the concentrations of CBZ and ISB within the operating range for the CS. The CS kinetic model was evaluated experimentally from startup to dynamic equilibrium over 10 residence times with monitoring by HPLC and in-line Raman spectroscopy. The developed kinetic model in tandem with in-line Raman spectroscopy successfully predicted disturbances due to changes in process variables and can serve as a useful tool in the future design of advanced process control strategies for the continuous synthesis of CBZ.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solution scattering at the Life Science X-ray Scattering (LiX) beamline

This work reports the instrumentation and software implementation at the Life Science X-ray Scattering (LiX) beamline at NSLS-II in support of biomolecular solution scattering. For automated static measurements, samples are stored in PCR tubes and grouped in 18-position sample holders. Unattended operations are enabled using a six-axis robot that exchanges sample holders between a storage box and a sample handler, transporting samples from the PCR tubes to the X-ray beam for scattering measurements. The storage box has a capacity of 20 sample holders. At full capacity, the measurements on all samples last for ∼9 h. For in-line size-exclusion chromatography, the beamline-control software coordinates with a commercial high-performance liquid chromatography (HPLC) system to measure multiple samples in batch mode. The beamline can switch between static and HPLC measurements instantaneously. In all measurements, the scattering data span a wide q -range of typically 0.006–3.2 Å −1 . Functionalities in the Python package py4xs have been developed to support automated data processing, including azimuthal averaging, merging data from multiple detectors, buffer scattering subtraction, data storage in HDF5 format and exporting the final data in a three-column text format that is acceptable by most data analysis tools. These functionalities have been integrated into graphical user interfaces that run in Jupyter notebooks, with hooks for external data analysis software.

60 APPLIED LIFE SCIENCES↗

Determination of 2,4-Dinitrophenol (2,4-DNP) in Simulated Radioactive Waste by High Performance Liquid Chromatography

The River Protection Project (RPP) at Hanford, Washington is evaluating an alternative treatment method for low activity tank waste (LAW) disposition. Specifically, grout solidification/immobilization for LAW needs to demonstrate adequate treatment for Land Disposal Restricted (LDR) Organic chemicals. LDR organic chemical pretreatment, such as evaporations testing and oxidation decomposition, are under assessment to reduce the LDR organic chemicals concentration in the LDR waste. 2,4-dinitrophenol was spiked into LAW simulated waste and monitored in these studies using High Performance Liquid Chromatography (HPLC). The development and implementation of this HPLC method is discussed in this presentation.

Dekarske, John R. [Savannah River National Laborat↗