Search NASA⌕ Search

SEARCH · Search NASA

Results for “HPd”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Understanding the haling power depletion (HPD) method

The Pennsylvania State Univ. (PSU) is using the university version of the Studsvik Scandpower Code System (CMS) for research and education purposes. Preparations have been made to incorporate the CMS into the PSU Nuclear Engineering graduate class 'Nuclear Fuel Management' course. The information presented in this paper was developed during the preparation of the material for the course. The Haling Power Depletion (HPD) was presented in the course for the first time. The HPD method has been criticized as not valid by many in the field even though it has been successfully applied at PSU for the past 20 years. It was noticed that the radial power distribution (RPD) for low leakage cores during depletion remained similar to that of the HPD during most of the cycle. Thus, the Haling Power Depletion (HPD) may be used conveniently mainly for low leakage cores. Studies were then made to better understand the HPD and the results are presented in this paper. Many different core configurations can be computed quickly with the HPD without using Burnable Poisons (BP) to produce several excellent low leakage core configurations that are viable for power production. Once the HPD core configuration is chosen for further analysis, techniques are available for establishing the BP design to prevent violating any of the safety constraints in such HPD calculated cores. In summary, in this paper it has been shown that the HPD method can be used for guiding the design for the low leakage core. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A New Electrostatically-focused UV HPD for Liquid Xenon

Appropriate photodetectors are a major challenge for liquid xenon technology as proposed by the next generation of double beta decay, solar neutrino, and dark matter searches. The primary photon signal is tiny and in the hard ultraviolet, the installation is cryogenic, and the sensors themselves must not introduce background. Hybrid photodiodes (HPDs) provide an easy substitute for a conventional PMT with the added advantages of low radioactivity, better area coverage, and single photoelectron counting. A computer-controlled test setup capable of characterizing optical properties of ultraviolet photodetectors was installed. It was used to compare photomultiplier tubes, silicon photomultipliers, avalanche photodiodes, and a novel-design custom HPD developed by the DEP company under this proposal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Technical Report for Award DE-FG02-05ER41389 A New Electrostatically-Focused, UV HPD for Liquid Xenon: A Direct Comparison with APD, PMT, SiPM in an Integrated Database

Within the scope of the project, a LXe detector and associated gas handling and purification system were set up to study the response of various photodetectors to the VUV Xe light. In particular we tested an Advanced Photonix Large Area Avalanche Photodiode (APD), Silicon Photomultipliers (SiPMs) from two different sources and an Hamamtsu Photonics APD. As part of the XENON Dark Matter project, sponsored by the National Science Foundation, we have accumulated independent knowledge of the response of compact metal channel photomultipliers. At this stage, we conclude that the last are far superior in terms of reliability and performance in a LXe detector environment. More studies are needed with APDs and SiPMs in LXe, taking advantage of the improved performance of these sensors with time. We could not test a hybrid PMT (HPD) since the only available unit on loan from one manufacturer lacked the mechanical stability and was packaged in a form not compatible with LXe purity requirements. Meanwhile, within the XENON collaboration, we are developing with Hamamatsu a hybrid PMT which is named QUPID (Quartz Photon Intensifying Detector) which promises to solve the problems of radioactivity and purity encountered with previous HPDs. We attach to this report two papers which summarize in detail the experimental st-ups, procedures and results obtained with different APDs and SiPMs operated in LXe. We continue our investigations of APDs in view of their potential appication in large arrays for LXe detectors. We intend to publish the results once we complete tests of newly acquired Hamamatsu APDs.

02 PETROLEUM↗

Materials Data on HPd by Materials Project

PdH is Halite, Rock Salt structured and crystallizes in the cubic Fm-3m space group. The structure is three-dimensional. Pd is bonded to six equivalent H atoms to form a mixture of corner and edge-sharing PdH6 octahedra. The corner-sharing octahedral tilt angles are 0°. All Pd–H bond lengths are 2.07 Å. H is bonded to six equivalent Pd atoms to form a mixture of corner and edge-sharing HPd6 octahedra. The corner-sharing octahedral tilt angles are 0°.

36 MATERIALS SCIENCE↗

Materials Data on HPd by Materials Project

PdH is Wurtzite structured and crystallizes in the hexagonal P6_3mc space group. The structure is three-dimensional. Pd is bonded to four equivalent H atoms to form corner-sharing PdH4 tetrahedra. There is one shorter (1.82 Å) and three longer (1.85 Å) Pd–H bond length. H is bonded to four equivalent Pd atoms to form corner-sharing HPd4 tetrahedra.

36 MATERIALS SCIENCE↗

Operating displays - new concept: high performance displays - 118

New control rooms in Nuclear Power Plants using digital Distributed Control System (DCS) operated with software displays, are providing thousands of signals to the operating crew. When an event happens, the Flood of information provided to operators could obscure the initiator event increasing the operator response time, work load and complicating the selection of the actions to be performed. There are some initiatives that are trying to minimize the 'avalanche effect' as the alarm engineering filtering and prioritization or diagnostic displays. Likewise, new control rooms are lost the availability to know the plant status just with a quick glance to the panel indicators. Regarding Small Modular Reactors, where in some cases four operators should monitor and control twelve reactors, these problems are even more significant. The challenge is to find a solution, based on current digital systems, that supply information to operators in order to prevent events and take early actions to minimize or avoid any unexpected incident. In order to minimize human errors, Tecnatom has developed a specific set of displays, called 'High Performance Displays' (HPD) based on objectives, work environment limitation, and non-anticipated events. These displays are being design following the HFE standards: applying the NUREG-0711 elements to identify the information that they have to content and the NUREG-0700 to design the interface. The function of these displays is monitoring the plant situation in a way that the operators are able to recognize any potential event at a simple glance but controlling thousands of signals through pattern recognition, symmetries, regular polygons and colors. The objective of the HPD is to provide an integrated function minimizing the tunnel effect and reduce the workload during the diagnosis phase. Moreover, HPD enhance operators to take the right actions to anticipate the response to any event, even avoiding it, if possible This paper analyzes how HPD's have been design as well as presents the results of a preliminary validation of their capabilities. The preliminary validation is a reduce validation in a full scope simulator running two representative scenarios of abnormal and emergency operation. The analysis is focused on the first stage of the event, i.e. the detection phase, HPD's have been installed in a generic full scope simulator of a nuclear power plant, digital controlled. Both scenarios have been performed by two different operator crews. The first operator shift has worked with the conventional human machine interface, that is, displays similar to the ones currently installed in existing nuclear power plant with digital control. The second crew, reproduce the same scenarios but with HPD available. The studio collects preliminary data in order to compare results, draw lesson learned from the experience to improve HPD design, and find solutions in terms of reducing human errors, human workload, and increase the availability of the plant. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Current-free double layers: A review

During the last decade, there has been an upsurge in the research on current-free DLs (CFDLs). Research includes theory, laboratory measurements, and various applications of CFDLs ranging from plasma thrusters to acceleration of charged particles in space and astrophysical plasmas. The purpose of this review is to present a unified understanding of the basic plasma processes, which lead to the formation of CFDLs. The review starts with the discussion on early research on electric fields and double layers (DLs) and ion acceleration in planar plasma expansion. The review continues with the formation of DLs and rarefaction shocks (RFS) in expanding plasma with two electron populations with different temperatures. The basic theory mitigating the formation of a CFDL by two-electron temperature population is reviewed; we refer to such CFDLs as double layers structures formation by two-temperature electron populations (TET-CFDLs). Application of TET-CFDLS to ion acceleration in laboratory and space plasmas was discussed including the formation of stationary steady-state DLs. A quite different type of CFDLs forms in a helicon plasma device (HPD), in which plasma abruptly expands from a narrow plasma source tube into a wide diffusion tube with abruptly diverging magnetic fields. The formation mechanism of the CFDL in HPD, referred here as current free double layer structure in helicon plasma device (HPD-CFDL), and its applications are reviewed. The formation of a TET-CFDL is due to the self-consistent separation of the two electron populations parallel to the ambient magnetic field. In contrast, a HPD-CFDL forms due to self-consistent separation of electrons and ion perpendicular to the abruptly diverging magnetic field in conjunction with the conducting wall of the expansion chamber in the HPD. One-dimensional theoretical models of CFDLs based on steady-state solution of Vlasov-Poisson system of equations are briefly discussed. Applications of CFDLs ranging from helicon double-layer thrusters (HDLTs) to the accelerations of ions in space and astrophysical plasmas are summarized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Examining the Angular Resolution of the Astro-H's Soft X-Ray Telescopes

The international x-ray observatory ASTRO-H was renamed Hitomi after launch. It covers a wide energy range from a few hundred eV to 600 keV. It is equipped with two soft x-ray telescopes (SXTs: SXT-I and SXT-S) for imaging the soft x-ray sky up to 12 keV, which focus an image onto the respective focal-plane detectors: CCD camera (SXI) and a calorimeter (SXS). The SXTs are fabricated in a quadrant unit. The angular resolution in half-power diameter (HPD) of each quadrant of the SXTs ranges between 1.1 and 1.4 arc min at 4.51 keV. It was also found that one quadrant has an energy dependence on the HPD. We examine the angular resolution with spot scan measurements. In order to understand the cause of imaging capability deterioration and to reflect it to the future telescope development, we carried out spot scan measurements, in which we illuminate all over the aperture of each quadrant with a square beam 8 mm on a side. Based on the scan results, we made maps of image blurring and a focus position. The former and the latter reflect figure error and positioning error, respectively, of the foils that are within the incident 8 mm x 8 mm beam. As a result, we estimated those errors in a quadrant to be approx. 0.9 to 1.0 and approx. 0.6 to 0.9 arc min, respectively. We found that the larger the positioning error in a quadrant is, the larger its HPD is. The HPD map, which manifests the local image blurring, is very similar from quadrant to quadrant, but the map of the focus position is different from location to location in each telescope. It is also found that the difference in local performance causes energy dependence of the HPD.

Astro-H/Hitomi; soft x-ray telescope; SXT; Wolter ↗

Optimal Transfer Operators in Algebraic Two-Level Methods for Nonsymmetric and Indefinite Problems

Consider an algebraic two-level method applied to the 𝑛-dimensional linear system 𝐴⁢𝒙 = 𝒃 using fine-space preconditioner (i.e., “relaxation” or “smoother”) 𝑀, with 𝑀 ≈ 𝐴, restriction and interpolation 𝑅 and 𝑃, and algebraic coarse-space operator 𝐴 𝑐 : = 𝑅 ∗ ⁢𝐴⁢𝑃. Then, what are the best possible transfer operators 𝑅 and 𝑃 of a given dimension 𝑛 𝑐 < 𝑛? Brannick et al. [12] showed that when 𝐴 and 𝑀 are Hermitian positive definite (HPD), the optimal interpolation is such that its range contains the 𝑛 𝑐 smallest generalized eigenvectors of the matrix pencil (𝐴, 𝑀). Recently, in Ali et al. [5] we generalized this framework to the non-HPD setting, by considering both right (interpolation) and left (restriction) generalized eigenvectors of (𝐴, 𝑀) and defining corresponding nonsymmetric transfer operators {𝑅#, 𝑃#}. Tight convergence bounds for {𝑅#, 𝑃#} are derived in spectral radius, as well as a proof of pseudo-optimality. Note, {𝑅#, 𝑃#} are typically complex valued, which is not practical for real-valued problems. Here, in this work, we build on [5], first characterizing all inner products in which the coarse-space correction defined by {𝑅#, 𝑃#} is orthogonal. We then develop tight two-level convergence bounds in these norms, and prove that the underlying transfer operators {𝑅#, 𝑃#} are genuinely optimal. As a special case, our theory both recovers and extends the HPD results from [12]. Finally, we show how to construct optimal, real-valued transfer operators in the case of that 𝐴 and 𝑀 are real valued, but are not HPD. Numerical examples arising from a discretized advection-reaction equation, wave-equation, and Stokes equations are used to verify and illustrate the theory.

97 MATHEMATICS AND COMPUTING↗

Cholangiographic Tumor Classification for Simple Patient Selection Prior to Hepatopancreatoduodenectomy for Cholangiocarcinoma

Background: Hepatopancreatoduodenectomy (HPD) is employed for patients with laterally advanced cholangiocarcinoma. However, the survival benefit of this extended approach remains controversial. The aim of this study is to identify a tumor feature benefiting from HPD from the standpoint of long-term survival. Patients and Methods: Patients with cholangiocarcinoma who underwent HPD with curative intent between 2001 and 2017 were retrospectively analyzed. Tumors were radiologically classified by preoperative cholangiogram. Diffuse type was defined as significant tumor/stricture located from the hilar to intrapancreatic duct; localized type was defined as tumor otherwise. Univariable and multivariable analyses were performed to identify prognostic indicators. Results: Of 100 study patients, 28 (28%) patients had diffuse tumor type, while the remaining 72 (72%) patients had localized tumors. The former group showed significantly longer lateral length (43 versus 22 mm, P < 0.001) and more frequent pancreatic invasion (50% versus 32%, P = 0.110), advanced T classification (64% versus 49%, P = 0.185), and nodal metastasis (57% versus 47%, P = 0.504), compared with the latter group. The survival for patients with diffuse tumor type was significantly worse than that for patients with localized tumor type, with 5-year survival rates of 59.0% versus 26.3%, respectively (P = 0.003). Multivariable analysis identified four independent factors deteriorating long-term survival: cholangiographic diffuse tumor (P = 0.021), higher age (P = 0.020), percutaneous biliary drainage (P = 0.007), and portal vein resection (P = 0.007). Conclusions: Presurgical cholangiographic classification, diffuse or localized type, is a tumor-related factor closely associated with survival probability; therefore, it may be a useful feature for patient selection prior to HPD for cholangiocarcinoma.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

X-ray mirror assessment with optical light

The imaging capability of a thin foil X-ray mirror has been examined with optical light, using a laser beam and a wide optical parallel beam. These measurements reveal that: (1) image broadening due to millimeter scale waviness (orange peel) of the aluminum substrate, partly intrinsic to the foil and partly caused during the foil treatment, is 1.2-min of arc half-power diameter (HPD) in two reflections; (2) slope errors due to foil shaping and misalignment cause broadening of 1.6-2.0-min of arc HPD; and (3) total broadening is about 3-min of arc HPD, which is consistent with the broadening of 2.6-min of arc HPD measured with X rays.

Kunieda, Hideyo↗

6-Cyclohexylmethyl-3-hydroxypyrimidine-2,4-dione as an inhibitor scaffold of HIV reverase transcriptase: Impacts of the 3-OH on inhibiting RNase H and polymerase

3-Hydroxypyrimidine-2,4-dione (HPD) represents a versatile chemical core in the design of inhibitors of human immunodeficiency virus (HIV) reverse transcriptase (RT)-associated RNase H and integrase strand transfer (INST). We report herein the design, synthesis and biological evaluation of an HPD subtype (4) featuring a cyclohexylmethyl group at the C-6 position. Antiviral testing showed that most analogues of 4 inhibited HIV-1 in the low nanomolar to submicromolar range, without cytotoxicity at concentrations up to 100 μM. Biochemically, these analogues dually inhibited both the polymerase (pol) and the RNase H functions of RT, but not INST. Co-crystal structure of 4a with RT revealed a nonnucleoside RT inhibitor (NNRTI) binding mode. Interestingly, chemotype 11, the synthetic precursor of 4 lacking the 3-OH group, did not inhibit RNase H while potently inhibiting pol. Here, by virtue of the potent antiviral activity and biochemical RNase H inhibition, HPD subtype 4 could provide a viable platform for eventually achieving potent and selective RNase H inhibition through further medicinal chemistry.

3-Hydroxypyrimidine-2,4-dione (HPD)↗

Direct ion flux measurements at high-pressure-depletion conditions for microcrystalline silicon deposition

The contribution of ions to the growth of microcrystalline silicon thin films has been investigated in the well-known high-pressure-depletion (HPD) regime by coupling thin-film analysis with plasma studies. The ion flux, measured by means of a capacitive probe, has been studied in two regimes, i.e., the amorphous-to-microcrystalline transition regime and a low-to-high power regime; the latter regime had been investigated to evaluate the impact of the plasma power on the ion flux in collisional plasmas. The ion flux was found not to change considerably under the conditions where the deposited material undergoes a transition from the amorphous to the microcrystalline silicon phase; for solar-grade material, an ion-to-Si deposition flux of ∼0.30 has been determined. As an upper-estimation of the ion energy, a mean ion energy of ∼19 eV has been measured under low-pressure conditions (<1 mbar) by means of a retarding field energy analyzer. Combining this upper-estimate with an ion per deposited Si atom ratio of ∼0.30, it is concluded that less than 6 eV is available per deposited Si atom. The addition of a small amount of SiH{sub 4} to an H{sub 2} plasma resulted in an increase of the ion flux by about 30% for higher power values, whereas the electron density, deduced from optical emission spectroscopy analysis, decreased. The electron temperature, also deduced from optical emission spectroscopy analysis, reveals a slight decrease with power. Although the dominant ion in the HPD regime is SiH{sub 3}{sup +}, i.e., a change from H{sub 3}{sup +} in pure hydrogen HPD conditions, the measured larger ion loss can be explained by assuming steeper electron density profiles. These results, therefore, confirm the results reported so far: the ion-to-Si deposition flux is relatively large but has neither influence on the microcrystalline silicon film properties nor on the phase transition. Possible explanations are the reported high atomic hydrogen to deposition flux ratio, mitigating the detrimental effects of an excessive ion flux.

36 MATERIALS SCIENCE↗

An 18 Element Strip of 1 mm$^{2}$ G-APDs for CMS HCAL upgrade results of CERN Test Beam 2009

The Compact Muon Solenoid hadronic barrel (CMS HB) calorimeter consists of 17 layers of scintillator in a brass absorber. Each scintillator consists of 16 tiles comprising one layer of the corresponding towers in pseudo-rapidity. The light from each tile is routed into a single 0.96 mm wavelength shifting fiber. In the current design, the 17 fibers from the full tower depth are directed into one pixel of a multi-channel hybrid photo-diode (HPD). Thus, no longitudinal shower information is readout. In the last year we have developed 18 element MAPD arrays (Micro-pixel Avalanche Photo Diodes) on 8 inch wafers with Zecotek in Singapore. A special prototype 20 pin ceramic package was made by Kyocera in Germany. By using 18 element G-APD strips (Geiger mode Avalanche photo diodes) we could readout each layer separately, so that 17 of these strips replace one HPD. Because of the large linear range requirement in the hadronic calorimeter and radiation hardness needed, we used the new generation high cell density Zecotek MAPDs with 15,000 cells per strip element. Due to the higher PDE (photon detection efficiency) versus the HPD (30% vs. 12%) we got 5 p.e. per layer for a MIP. Due to limited availability of electronic channels for these tests, analog signals from multiple strips were added together providing digital readout from four depth segments. Non uniformity between strips was calibrated using muons and measurements of breakdown voltage of each element of the array. After calibration of the 4 longitudinal depth segments, the linearity and detector resolution was studied using pions with energies from 30 to 300 GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Tautomeric Half-reaction of BphD, a C-C Bond Hydrolase Kinetic and Structural Evidence Supporting a Key Role for Histidine 265 of the Catalytic triad

BphD of Burkholderia xenovorans LB400 catalyzes an unusual C-C bond hydrolysis of 2-hydroxy-6-oxo-6-phenylhexa-2,4-dienoic acid (HOPDA) to afford benzoic acid and 2-hydroxy-2,4-pentadienoic acid (HPD). An enol-keto tautomerization has been proposed to precede hydrolysis via a gem-diol intermediate. The role of the canonical catalytic triad (Ser-112, His-265, Asp-237) in mediating these two half-reactions remains unclear. We previously reported that the BphD-catalyzed hydrolysis of HOPDA ({lambda}{sub max} is 434 nm for the free enolate) proceeds via an unidentified intermediate with a red-shifted absorption spectrum ({lambda}{sub max} is 492 nm) (Horsman, G. P., Ke, J., Dai, S., Seah, S. Y. K., Bolin, J. T., and Eltis, L. D. (2006) Biochemistry 45, 11071-11086). Here we demonstrate that the S112A variant generates and traps a similar intermediate ({lambda}{sub max} is 506 nm) with a similar rate, 1/{tau} {approx} 500 s{sup -1}. The crystal structure of the S112A:HOPDA complex at 1.8-{angstrom} resolution identified this intermediate as the keto tautomer, (E)-2,6-dioxo-6-phenyl-hex-3-enoate. This keto tautomer did not accumulate in either the H265A or the S112A/H265A double variants, indicating that His-265 catalyzes tautomerization. Consistent with this role, the wild type and S112A enzymes catalyzed tautomerization of the product HPD, whereas H265A variants did not. This study thus identifies a keto intermediate, and demonstrates that the catalytic triad histidine catalyzes the tautomerization half-reaction, expanding the role of this residue from its purely hydrolytic function in other serine hydrolases. Finally, the S112A:HOPDA crystal structure is more consistent with hydrolysis occurring via an acyl-enzyme intermediate than a gem-diol intermediate as solvent molecules have poor access to C6, and the closest ordered water is 7{angstrom} away.

36 MATERIALS SCIENCE↗

Statistics and sensitivity of axion wind detection with the homogeneous precession domain of superfluid helium-3

The homogeneous precession domain (HPD) of superfluid He 3 has recently been identified as a detection medium which might provide sensitivity to the axion-nucleon coupling g a N N competitive with, or surpassing, existing experimental proposals. In this work, we make a detailed study of the statistical and dynamical properties of the HPD system in order to make realistic projections for a full-fledged experimental program. We include the effects of clock error and measurement error in a concrete readout scheme using superconducting qubits and quantum metrology. This work also provides a more general framework to describe the statistics associated with the axion gradient coupling through the treatment of a transient resonance with a nonstationary background in a time-series analysis. Incorporating an optimal data-taking and analysis strategy, we project a sensitivity approaching g a N N ∼ 10 − 12 GeV − 1 across a decade in axion mass. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Test and characterization of finely segmented pixel CZT detectors for future hard x-ray missions

The NuSTAR (Nuclear Spectroscopic Telescope Array) mission was launched in 2012, and it has successfully deployed the first orbiting telescopes to focus high energy X-ray (3 - 79 keV) light, providing a wealth of new information on high-energy X-rays sources. Follow-up missions, such as the proposed HEX-P, BEST, and FORCE, could perform a deeper black hole census providing a more refined measurement of black hole spins, allowing for greater knowledge about supermassive black holes. Here, these missions are motivated by the recent breakthroughs in the hard X-ray mirror technologies, where mirrors, either made of monolithic silicon segments, or made directly or via replication of shells, demonstrate the feasibility of making hard X-ray mirrors with angular resolutions of 5-10 arc-seconds Half Power Diameter (HPD) compared to the NuSTAR’s 1 arc-minute HPD. Such a high angular resolution requires matched detectors with higher degree of segmentation to fully benefit from the achievable improved spatial resolution. In the above framework, the HEXID ASIC, a novel pixelated front-end suitable for reading out a finely segmented CZT sensor with 150 μm pixel pitch in a hexagonal arrangement has been developed. This readout pixelated chip is capable of processing photon-generated charge packets over a large dynamic range (from 2 keV up to 180 keV), while keeping a low input noise (ENC <20 e - ). In this work, the initial characterization of the ASIC prototype will be presented.

47 OTHER INSTRUMENTATION↗