Energy performance evaluation of the ASHRAE Guideline 36 control and reinforcement learning–based control using field measurements

This study evaluates the energy performance of ASHRAE Guideline 36–compliant control (ASHRAE 36 control) and reinforcement learning (RL)–based control through experimental field tests and a simulation study. Three field tests were conducted at Oak Ridge National Laboratory’s commercial building test facility in Oak Ridge, Tennessee: a baseline with a baseline conventional control, a test with ASHRAE 36 control, and a test with RL-based control. The selected ASHRAE 36 controls were trim and respond control, as well as variable air volume (VAV) box control. We compared the measured supply air temperature of the rooftop unit, VAV box supply air temperature, and VAV box supply airflow rate across the three test cases. The field data indicated that ASHRAE 36 controls operated as specified by ASHRAE Guideline 36. Based on these data, ASHRAE 36 control achieved a 45 % reduction in hourly averaged HVAC energy consumption compared with the baseline, and RL-based control achieved a 66 % reduction. These potential annual energy savings were confirmed using a calibrated whole-building energy model. Compared with the baseline, ASHRAE 36 control reduced HVAC energy consumption by 42 %, and RL-based control achieved a 54 % reduction. Furthermore, RL-based control reduced total HVAC energy consumption by 21 % more than ASHRAE 36 control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of ambient temperature on electric vehicle range considering battery Performance, powertrain Efficiency, and HVAC load

Here, this study investigates the impact of ambient temperature on the range of electric vehicles (EVs) by analyzing its effects on usable battery energy (UBE), heating, ventilation, and air conditioning (HVAC) energy consumption, and powertrain energy losses. Chassis dynamometer tests within a thermal chamber were conducted under various temperature conditions to investigate these impacts. The results indicate that lower temperatures lead to a decrease in UBE for lithium-ion batteries in EVs. At −18 °C, the UBE exhibited reductions of 4---8 % compared to the UBE at 22 °C. Battery thermal management strategies significantly affected the UBE loss, with different strategies resulting in distinct UBE reductions. HVAC energy consumption, especially for interior heating, proved to be the most dominant variable affecting EV driving range. Larger discrepancies between the HVAC target temperature (22 °C) and the ambient temperature increased HVAC energy usage. The type of HVAC system also influenced energy consumption, where EVs equipped with heat pumps demonstrated lower energy consumption for heating compared to those relying solely on resistance heaters. Ambient temperature also influenced motor energy consumption due to increased frictions, powertrain losses and tire rolling resistance at lower temperatures; consequently, regenerative braking energy decreased in cold conditions. Combining these effects influenced the overall energy consumption and driving range of EVs. At −18 °C, the driving range saw a substantial decrease of up to 60 % compared to 22 °C, while a slight decrease was observed at 35 °C.

Ambient Temperature↗

Simulation & Analysis of the Hydronic Shell Retrofit System as a Solution for Deep Energy Retrofits and Electrification of Large Multifamily Housing Communities in Cold Climate

Among 32 million multi-family buildings in the United States, approximately 42% have poor or no insulation. Envelope retrofits of these buildings will provide thermal resiliency and enable a pathway to electrification of space heating systems as a result of improved thermal performance. Hydronic Shell (HS) is a technology which combines an insulated retrofit panel with a heating, ventilation and air-conditioning (HVAC) thus enabling both envelope retrofit and space heating electrification. In this study, we used whole building energy simulation to evaluate energy impact of multi-family building retrofit with hydronic shell system. The simulation was performed for four locations of New York, Syracuse, Chicago and Boston. The results from the simulation showed more than 66% cooling energy reduction and more than 88% heating energy reduction from Hydronic Shell retrofit compared to Baseline building in all four locations. This reduction in energy consumption resulted in up to 219 MT reduction in annual CO2 emission. The cost reduction per floor area achieved from HVAC energy consumption reduction using Hydronic Shell retrofit was 0.66 to 0.99 $\$$/ft 2 . The results also showed higher percentage of heating energy reduction comes from the envelope only retrofit and higher percentage of cooling energy reduction comes from the retrofit HVAC system for the four locations under study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Contextually Supervised Optimization-Based HVAC Load Disaggregation Methodology

This paper presents a novel contextually supervised optimization-based approach for disaggregating heating, ventilation, and air-conditioning (HVAC) loads using smart meter or Supervisory Control and Data Acquisition data. To disaggregate the load into HVAC loads, large and infrequently used loads (LIUL), and base loads, we formulate an optimization problem to minimize a set of five loss terms, consisting of the reconstruction errors of the overall load profile, the ramp rate losses, and three distinct loss functions linked with the HVAC load, base load, and LIUL, respectively. To enhance accuracy, we incorporate two forms of contextual information into the problem formulation. First, we utilize mutual information to estimate HVAC energy consumption. Second, we employ a base load dictionary to constrain HVAC load estimation errors. The obtained HVAC load profiles are fine-tuned by abnormal ramp detection followed by binary hypothesis testing. Here, the proposed method is developed and tested using sub-metered residential and commercial building data. Simulation results show that the proposed method outperforms existing methods across various data resolutions and load aggregation levels, showing excellent transferability and generalizability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The first field application of a low-cost MPC for grid-interactive K-12 schools: Lessons-learned and savings assessment

K-12 schools are the largest energy consumers in the public sector, with their HVAC energy consumption representing the largest portion of their total energy use. While transitioning these schools to grid-interactive HVAC system operation through advanced controls offers significant financial and environmental benefits, and model predictive control (MPC) has been identified as a promising solution to achieve that, very few MPCs are affordable and have been deployed in K-12 schools. This situation raises concerns about the unclear real-world benefits of MPC technology among facility managers and industries. To address this gap, this paper presents a low-cost MPC solution that requires minimal control infrastructure costs and a unique field demonstration at a K-12 school, conducted for both cooling and heating seasons. This work adopted a previously developed MPC and extended it for use in the school application. The MPC aims to coordinate multiple packaged units to eliminate unnecessary peaks and shift cooling or heating loads in response to grid signals based on load conditions, while maintaining thermostat temperatures within school-defined bounds. Throughout the field tests, the MPC achieved a 24% reduction in peak demand during the cooling season and shifted cooling or heating loads by up to 16% in response to the school's utility tariff, considering load conditions, while also allowing end-users to override thermostat setpoints. Further, the paper also discusses the limitations of this study and future research directions for better performance of the MPC at K-12 schools.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermoelectric air conditioning undergarment for personal thermal management and HVAC energy saving

Personal thermal management systems (PTMS) are highly desirable for improving individual thermal comfort and reducing indoor HVAC energy consumption. Although there have been many attempts in developing PTMS, existing PTMS are generally bulky, heavy or immobile. Besides, previous analysis on additional personal cooling and heating power required for maintaining thermal comfort in changing environments did not consider the individual difference in metabolism and the variability of comfort skin temperature with environmental conditions. In this paper, we report on the development of a novel lightweight (<1 kg) thermoelectric air conditioning undergarment system with a preferred design of branching tubing network (branching angle of 60° and diameter ratio of 0.782) for air distribution. Through thermal manikin and human subject tests, we demonstrated that the novel system is capable of providing a maximum of 15.5 W of personal cooling and 18.1 W personal heating with a coefficient of performance (COP) greater than 0.4, which is sufficient to the expansion of the indoor set-points by at least 2.2 °C (4 °F) on both sides without compromising thermal comfort and the potential saving of about 15% HVAC energy. Furthermore, our study improved the understanding of the required additional personal cooling and heating power for changing environmental conditions, which are essential guidelines for the further development of PTMS.

42 ENGINEERING↗

A three-year dataset supporting research on building energy management and occupancy analytics

Abstract This paper presents the curation of a monitored dataset from an office building constructed in 2015 in Berkeley, California. The dataset includes whole-building and end-use energy consumption, HVAC system operating conditions, indoor and outdoor environmental parameters, as well as occupant counts. The data were collected during a period of three years from more than 300 sensors and meters on two office floors (each 2,325 m 2 ) of the building. A three-step data curation strategy is applied to transform the raw data into research-grade data: (1) cleaning the raw data to detect and adjust the outlier values and fill the data gaps; (2) creating the metadata model of the building systems and data points using the Brick schema; and (3) representing the metadata of the dataset using a semantic JSON schema. This dataset can be used in various applications—building energy benchmarking, load shape analysis, energy prediction, occupancy prediction and analytics, and HVAC controls—to improve the understanding and efficiency of building operations for reducing energy use, energy costs, and carbon emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coloured low-emissivity films for building envelopes for year-round energy savings

We report that buildings are responsible for over 40% of total US energy use, of which about 40% is directly related to the operation of heating, ventilation and air-conditioning (HVAC) systems. Saving energy to heat and cool buildings would contribute substantially to sustainability. Here we propose a category of coloured low-emissivity films for building walls that constitute the main component of the building thermal envelope. We demonstrate high reflectance (~90%) in infrared wavelength range and selective reflectance in the visible light wavelength range for desired colours. These films can help minimize radiative heat exchange between the indoor and outdoor environments, thus saving energy for all-year cooling and heating while satisfying the required aesthetical effect. Simulations show that these films can help reduce heat gain and loss by up to 257.6 MJ per installation wall area annually. In the case of a typical midrise apartment building, the HVAC system can save up to 124.46 GJ (equal to 9.87% of the building’s HVAC energy consumption). By rough estimation, a global CO 2 emission reduction of 1.14 billion metric tons annually could be achieved. Our work provides insights for innovative energy-saving building envelope materials that can help achieve global carbon neutrality and sustainability.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Validation of a Smart Energy Recovery Ventilation System Using Low-Cost Indoor Air Quality Sensors

This project is a field validation, using low-cost indoor air quality (IAQ) sensors, of a smart ventilation system that can help low-load homes in humid environments maintain acceptable indoor humidity conditions while providing adequate ventilation according to ASHRAE 62.2. The objectives of this research were to (1) address builders’ concerns with mechanical ventilation in humid environments and (2) answer the question of whether smart control logic helps with occupant comfort and the creation of a more acceptable indoor environment. To address the objectives of the study, the Southface team collected field data for one year in four Charleston, South Carolina, new construction homes in order to determine the differences in occupant comfort; comfort metrics; IAQ; and heating, ventilating, and air-conditioning (HVAC) energy consumption when toggling biweekly between an energy recovery ventilator (ERV) operating continuously and an ERV operating with smart, time-varying humidity control logic. The smart ventilation algorithm under consideration in this field test did create a less humid indoor environment on an annual basis as quantitatively measured through temperature and relative humidity (T/RH) readings, expressed most discernably as “percentage of time above 60% RH” and “percentage of time above 55°F dewpoint.” However, the difference it made was inconsistent during the spring, summer, and fall months, and it was only directionally consistent during the winter months. We suspect that this is primarily due to the long runtimes and concomitant dehumidification activity of the air-conditioning (A/C) units in response to the high sensible loads in Charleston. The effect of the smart ventilation algorithm was not discernable to the occupants in this study, as recorded through seasonal surveys.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Performance of Awnings in Residential Buildings

Residential buildings consume approximately 20% of the total primary energy in the United States. More than 50% of this energy is spent in heating, cooling, and lighting these buildings. Solar heat gain is one of the largest and most variable sources of cooling load in these buildings, while it can also provide passive heating during the heating season. Shading devices can be used to control the amount of solar heat gain in buildings. Various studies have considered how different shading devices and their applications affect energy and occupant comfort in buildings. However, most of these studies were limited to planar shading devices such as roller shades, cellular shades, and blinds. Although some theoretical studies have been performed for awnings, the energy performance of awnings has rarely been studied via either energy simulation or field measurement. In this study, the authors evaluated the energy performance of typical operable awnings by using field data, aided by simulation. Awnings were installed on a real house, and measurements were performed to evaluate the thermal performance of the awning. The measured data were then used to develop a calibrated energy model and evaluate the awning’s energy performance. The annual simulation of the building model used showed that awnings left in the closed position from April to September can reduce annual HVAC energy consumption by 15% compared with a building without any shades. The validated model was used in US Department of Energy prototype buildings to evaluate awning energy performance in climate zones 1A through 4B via energy simulation. For these prototype buildings, energy savings of up to 1,034 kWh were achieved for a building with a conditioned floor area of 2,377 ft 2 .

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Potential Cooling Energy Savings of Economizer Control and Artificial-Neural-Network-Based Air-Handling Unit Discharge Air Temperature Control for Commercial Building

Heating, ventilation, and air-conditioning (HVAC) systems play a significant role in building energy consumption, accounting for around 50% of total energy usage. As a result, it is essential to explore ways to conserve energy and improve HVAC system efficiency. One such solution is the use of economizer controls, which can reduce cooling energy consumption by using the free-cooling effect. However, there are various types of economizer controls available, and their effectiveness may vary depending on the specific climate conditions. To investigate the cooling energy-saving potential of economizer controls, this study employs a dry-bulb temperature-based economizer control approach. The dry-bulb temperature-based control strategy uses the outdoor air temperature as an indicator of whether free cooling can be used instead of mechanical cooling. This study also introduces an artificial neural network (ANN) prediction model to optimize the control of the HVAC system, which can lead to additional cooling energy savings. To develop the ANN prediction model, the EnergyPlus program is used for simulation modeling, and the Python programming language is employed for model development. The results show that implementing a temperature-based economizer control strategy can lead to a reduction of 7.6% in annual cooling energy consumption. Moreover, by employing an ANN-based optimal control of discharge air temperature in air-handling units, an additional 22.1% of cooling energy savings can be achieved. In conclusion, the findings of this study demonstrate that the implementation of economizer controls, especially the dry-bulb temperature-based approach, can be an effective strategy for reducing cooling energy consumption in HVAC systems. Additionally, using ANN prediction models to optimize HVAC system controls can further increase energy savings, resulting in improved energy efficiency and reduced operating costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nationwide HVAC Energy-Saving Potential Quantification for Office Buildings with Occupant-Centric Controls in Various Climates

The occupant-centric control (OCC) is receiving an increasing attention due to its ability to reduce building heating ventilation and air-conditioning (HVAC) system energy consumptions while not affecting the occupant thermal comfort. This paper aims to investigate and quantify the nationwide energy-saving potential of implementing the occupant-centric HVAC controls in typical office buildings using a whole building simulation software EnergyPlus. First, the medium office and large office from the Department of Energy (DOE) Commercial Prototype Building Models (CBPM) were enhanced to have detailed layouts and dynamic occupancy schedules. Then, a comprehensive simulation plan was created by incorporating the multiple zone-level and system-level occupant-centric building HVAC controls recommended by the updated ASHRAE Standard 90.1 – 2019 and ASHRAE Guideline 36 – 2018. Three control scenarios with different occupancy sensing methods were identified in this simulation plan. A nation-wide parametric analysis which includes two building types, three occupancy sensing scenarios, two building code versions, and 16 U.S. climate zones was carried out. The simulation results of the key control variables and HVAC energy consumption suggest that generally, both the occupancy presence sensor and occupant counting sensor could achieve energy savings for the office buildings in majority of the scenarios. However, compared with the occupancy presence sensor, which could support both the temperature setpoint reset and operational breathing zone airflow rate reset for the unoccupied zones, the occupant counting sensor only brings a marginal benefit. Besides, a higher HVAC energy-saving ratio could be achieved in the heating-dominated zone, since the energy reduction brought with the minimum outdoor airflow rate reset is stronger in the heating mode.

Pang, Zhihong↗

Retrofitting Buildings with Solar-Reflective Roofs and Walls and its Impact on Peak Power Demand

Buildings are a major consumer of electricity in the United States and a significant portion of the consumption comes from heating, ventilation, and air-conditioning (HVAC) applications. Passive cooling strategies in the building envelope help to reduce the energy consumption for HVAC as well as peak electricity demand. Although being one of the most cost-effective passive cooling strategies, modern reflective roofing and reflective exterior wall technology is not well documented for its impact on peak demand. This study utilized whole building energy simulations on residential and commercial building prototype models to quantify the impact of cool roofs and cool exterior walls. The analysis was performed in three climate zones with varying insulation levels and solar reflectances for roofs and exterior walls. For both the residential and commercial buildings, the baseline building had a roof solar reflectance value of 0.10 and an exterior wall solar reflectance value of 0.25. The results from the simulations show that roofs and exterior walls with higher reflectance values increase cooling energy savings but can also increase heating energy consumption. The impact of changes in solar reflectances was greater in buildings with low roof/wall insulation levels compared to roofs/walls with higher insulation levels. A baseline for the simulations was set with the roof and exterior wall solar reflectances set at 0.1 and 0.25, respectively and simulations having varying roof and exterior wall thermal resistances were compared to the baselines.

14 SOLAR ENERGY↗

Learning-based framework for sensor fault-tolerant building HVAC control with model-assisted learning

As people spend up to 87% of their time indoors, intelligent Heating, Ventilation, and Air Conditioning (HVAC) systems in buildings are essential for maintaining occupant comfort and reducing energy consumption. These HVAC systems in smart buildings rely 'on real-time sensor readings, which in practice often suffer from various faults and could also be vulnerable to malicious attacks. Such faulty sensor inputs may lead to the violation of indoor environment requirements (e.g., temperature, humidity, etc.) and the increase of energy consumption. While many model-based approaches have been proposed in the literature for building HVAC control, it is costly to develop accurate physical models for ensuring their performance and even more challenging to address the impact of sensor faults. In this work, we present a novel learning-based framework for sensor fault-tolerant HVAC control, which includes three deep learning based components for 1) generating temperature proposals with the consideration of possible sensor faults, 2) selecting one of the proposals based on the assessment of their accuracy, and 3) applying reinforcement learning with the selected temperature proposal. Moreover, to address the challenge of training data insufficiency in building-related tasks, we propose a model-assisted learning method leveraging an abstract model of building physical dynamics. Through extensive experiments, we demonstrate that the proposed fault-tolerant HVAC control framework can significantly reduce building temperature violations under a variety of sensor fault patterns while maintaining energy efficiency.

Xu, Shichao↗

Comparative Analysis of ANN and LSTM Prediction Accuracy and Cooling Energy Savings through AHU-DAT Control in an Office Building

This paper proposes the optimal algorithm for controlling the HVAC system in the target building. Previous studies have analyzed pre-selected algorithms without considering the unique data characteristics of the target building, such as location, climate conditions, and HVAC system type. To address this, we compare the accuracy of cooling load prediction using ANN and LSTM algorithms, widely used in building energy research, to determine the optimal algorithm for HVAC control in the target building. We develop a simulation model calibrated with actual data to ensure data reliability and compare the energy consumption of the existing HVAC control method and the two algorithms-based methods. Results show that the ANN algorithm, with a CV(RMSE) of 12.7%, has a higher prediction accuracy than the LSTM algorithm, CV(RMSE) of 17.3%, making it a more suitable algorithm for HVAC control. Furthermore, implementing the ANN-based approach results in a 3.2% cooling energy reduction from the optimal control of Air Handling Unit (AHU) Discharge Air Temperature (DAT) compared to the fixed DAT at 12.8 °C in a representative day. This study demonstrates that ML-based HVAC system control can effectively reduce cooling energy consumption in HVAC systems, providing an effective strategy for energy conservation and improved HVAC system efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multi-task deep reinforcement learning for intelligent multi-zone residential HVAC control

In this short communication, a data-driven deep reinforcement learning (deep RL) method is applied to minimize HVAC users’ energy consumption costs while maintaining users’ comfort. The applied deep RL method's efficiency is enhanced by conducting multi-task learning that can achieve an economic control strategy for a multi-zone residential HVAC system in both cooling and heating scenarios. The applied multi-task deep RL method is compared with a rule-based benchmark case and a single-task deep deterministic policy gradient algorithm to verify its effective and generalized application in optimizing HVAC operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air quality and comfort constrained energy efficient operation of multi-zone buildings

Maintaining indoor air quality (IAQ) through effective ventilation is essential for the well-being and productivity of building occupants. Control strategies aimed at improving the efficiency of heating, ventilation and air conditioning (HVAC) systems must jointly determine ventilation and heating and cooling processes. Here, in this paper, we study the problem of minimizing the energy consumption of the HVAC system in a multi-zone building, while meeting thermal comfort and IAQ requirements. We first perform a steady state analysis of the zonal carbon dioxide (CO 2 ) concentration and the temperature dynamics. The resulting expressions are convex in the zonal mass flow rates and zonal temperatures. Guided by the steady state solutions for meeting the thermal comfort constraints, we develop two control policies for improving the energy efficiency of building HVAC systems while jointly satisfying indoor temperature and IAQ constraints. We compare the performance of our proposed approaches with those of multiple baseline approaches which implement separate regimes for controlling zonal temperature and IAQ for a typical work-day in a multi-zone campus building. We have evaluated the performance of our proposed approaches under varying levels of flexibility in zonal temperatures. We have shown that zonal temperature flexibility can result in energy savings up to 32% (for the same control strategies) as compared to the case where no such flexibility is permitted. Our proposed approaches were seen to offer potential savings of nearly 29% compared to the baseline.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Learning-based CO 2 concentration prediction: Application to indoor air quality control using demand-controlled ventilation

There have been increasing concerns over the air quality inside buildings as high levels of bio-effluents can cause nausea, dizziness, headaches, and fatigue to the people working in those spaces. First published in 2004 as Standard 62.1, ASHRAE Standard 62.2-2019 requires highly occupied spaces to implement heating, ventilation, and air conditioning (HVAC) that can dilute contaminants produced by occupants. In this regard, occupant-centric ventilation control has been regarded as an effective practice to maintain a satisfactory indoor air quality (IAQ) when dealing with highly variable occupancy environments. However, few established models in current literature and practice consider dynamic occupancy behavior and adaptive IAQ control. To address this gap, a dynamic indoor CO2 model is constructed using machine learning algorithms to forecast CO2concentrations across a range of forecasting horizons. Herein, we tuned and compared six state-of-the-algorithms—including Support Vector Machine, Ada Boost, Random Forest, Gradient Boosting, Logistic Regression, and Multilayer Perceptron. The algorithms’ performances are validated using CO 2 and historical meteorological data collected from a campus classroom with a variable occupancy rate. Simulation results showed that Multilayer Perceptron can strongly predict the volatile CO 2 behavior and also outperforms other algorithms in terms of accuracy. Furthermore, a control strategy capable of modeling and detecting dynamic patterns of CO 2 level is utilized to modulate the ventilation rate in real-time and also reduce the energy consumption. The proposed controller reduced the HVAC fan’s energy consumption by 51.4% and provide ventilation as needed per the ASHRAE standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗